Cisco MV-HW Network Camera Installation Guide

CISCO MV-HW Network Camera

MV2-HW Installation Guide

MV2 Overview
The Cisco Meraki MV2 is an indoor wireless networked camera that is exceptionally simple to deploy and configure due to its integration into the Meraki dashboard and the use of cloud augmented edge storage. The MV family eliminates the complex and costly servers and video recorders required by traditional solutions which removes the limitations typically placed on video surveillance deployments.

Package Contents and Wall Mount Hardware

In addition to the MV camera, the following are provided:

MV2 Power Up and Installation Setup

Power Options
The MV2 can be powered using either the MA-PWR-ETH dongle or the MA-PWR-USB-XX power adapter (where XX can be -US, -UK, -EU, or -AU). These are optional accessories and ordered separately.

The MV2 can be set up either as a table-top orientation or via wall mount
. Figure 1 Table Top and Figure (2) Wall Mount. Once the camera is setup in the desired orientation, the camera head can be adjusted for a customized viewing angle based upon the user’s preference.

Figure (1) -Table Top Once the MV2 is setup in the desired orientation. The camera lens can be adjusted to the end-user’s viewing preference.

Power Options

The MV2 can be powered using either the MA-PWR-ETH dongle or the MA-PWR-USB-XX power adapter (where XX can be -the US, -the UK, -EU, or -AU). These are optional accessories and are ordered separately.

Pre-Install Preparation

You should complete the following steps before installing the MV2 in its final location.

Configure your MV2 in the Networking using Dashboard

You should complete the following steps before installing the MV2 in its final location.
The following is a brief overview only of the steps required to add a MV2 to your network. For detailed instructions about creating, configuring, and managing Meraki Camera networks, refer to the online documentation (https://documentation.meraki.com/MV).

  1. Login to http://dashboard.meraki.com. If this is your first time, create a new account.
  2. Find the network to which you plan to add your camera(s) or create a new network.
  3. Add your camera(s) to your new network. You will need your Meraki order number (found on your invoice) or the serial number of each camera, which looks like Qxxx-xxxx-xxxx, and is found on the bottom of the unit.
  4. Verify that the camera is now listed under Cameras > Monitor > Cameras.
Check and Configure Firewall Settings

If a firewall is in place, it must allow outgoing connections to particular ports using given IP addresses. The most current list of outbound ports and IP addresses for your particular organization can be found here.

DNS Configuration

Each MV2 will generate a unique domain name to allow for secured direct streaming functionality. These domain names resolve an A record for the private IP address of the camera. Any public recursive DNS server will resolve this domain.
If utilizing an onsite DNS server, please whitelist *.devices.meraki.direct or configure a conditional forwarder so that the local domains are not appended to *.devices.meraki.direct and that these domain requests are forwarded to Google public DNS.

Assigning IP Addresses

At this time, the MV2 does not support static IP assignment. MV2 units must be added to a subnet that uses DHCP and has available DHCP addresses to operate correctly.

Installation Instructions

Note: Each MV2 comes with an instruction insert within the box. This insert contains detailed step-by- step guides and images to assist in the physical installation of the camera. A pdf can be found here.
(Note—this is a draft hyperlink not active yet.)

Note: During first time setup, the MV2 will automatically update to the latest stable firmware. Some features may be unavailable until this automatic update is completed. This process may take up to 10 minutes due to enabling of whole disk encryption.

Wall Mounting Instructions

For most mounting scenarios, the MV2 wall mount provides a quick, simple, and flexible means of mounting your device. The installation should be done in a few simple steps—

Regulatory Statements

EU Radiation Exposure Statement
Installing or mounting of this device shall be done as such that a minimum separation distance (distance between a person and the device, or the device’s antennas) of 20 cm is always ensured.

FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution
Any changes or modifications not expressly approved by Cisco Systems, Inc. could void the user’s authority to operate this equipment. This Transmitter must not be co-located or operation in conjunction with any other antenna or transmitter.

FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
IEEE 802.11b or 802.11g operation of this product in the USA is firmware-limited to channels 1 through 11.

Industry Canada Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Industry Canada Caution
(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
Avertissement:
(i) les dispositifs fonctionnant dans la bande 5 150-5 250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;

Industry Canada Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

Statement CS-0438 – Taiwan RoHS
Taiwan RoHS “Restricted Substances Content Disclosure Table” web address
www.cisco.com/go/taiwanrohs