Philips PHL456014 Wall Switch Module User Manual

PHILIPS PHL456014 Wall Switch Module

Including

Excluding

Connect to APP

Work on Electrical installations is in some countries only allowed by a qualified electrician. For support contact a local electrician or authority to install the product in accordance with national and electrical codes.

Warning: electric shock

The electrical circuit and attached light source will always be powered after installation, turn off the circuit breaker when replacing a light fixture /battery.

Wire Connectors Instructions

  1.  Turn off power before installing or removing connectors.
  2. Strip wires 5/16″(7.9mm). For #16 and smaller wires, strip 3/8″(9.5mm).
  3.  Pre-twisting unnecessary, hold stripped wires together with ends even. Lead stranded wires slightly.
  4.  Push wires into connector and screw on until two twists are visible in wires.

For use with copper to copper conductor
Temperature Rating: 105°C (221 °F) Max.
Voltage Rating: 600V Max. building wiring; 1000V Max. in fixtures and signs
Listed as a PRESSURE-TYPE wire connector on the following Solid wire combinations: For UL Listed, CSA Certified
Max. wire size (AWG): 22 – 10
Splice capacity: 3+ ground

CAUTION:

INSTALLATION STEPS

* Terminal screw positions may vary per manufacturer.

HUE APP

www.philips-hue.com

www.philips-hue.com/wallswitchmodulesupport

CAUTION

AFTER INSTALLATION