PN-HY501 Dismantle Instruction

LCD MONITOR
MODEL
PN-HY501
Dismantle Instruction

Scope

This document describes dismantling instruction according to Annex VII of Directive 2012/19/EU.

Tools for dismantling

Below tools are required to dismantle this product.

  • Screw Driver
  • Nipper

Dismantle Procedure

This product can be dismantled by below steps.

  1. Remove Back covers (section 4)
  2. Remove Printed circuit boards (section 5)
  3. Remove Battery (section 6)
  4. Dismantle LCD (section 7)
  5. Remove Electrolyte Capacitors (section 8)

Back covers

Back cover can be removed by a screwdriver.

Printed circuit boards

Battery

This model uses only AAA battery for remote control.
Battery can easily be removed.

LCD Module

– LCD Dismantle procedure

  1. Remove Rear cover
  2. Remove PWBs
  3. Remove the Cables

Capacitors

Electrolyte Capacitors which diameter/height is larger than 25mm are installed on Power PWB.
These capacitors can be removed by using a nipper to cut the leads.

Parts List

Parts described in Annex VII of directive 2012/19/EU are as below.

Parts  Note 
LCD 50inch LCD module
Printed Circuit Boards Main I/F PWB
Power PWB
T-CON PWB
Battery AAA battery
Electrolyte capacitors (height >25mm, diameter >25mm) On Power PWB
External electric cables 2 kinds of Power Cord
– for EU
– for UK