LG AKB74855311 Heating Configurator Installation Guide
LG Heating Configurator
* Applied model: R32 Series, R410A Split Hydro Box
R32 IWT, R32 Hydrosplit will be supported within 2020.
Easy Installation Setting and Commissioning
- Based on installation site information, installers can prepare to preset with the LG heating configurator and save data into a memory card from the office.
- Once on-site, installers can simply insert a memory card into the back of the remote control to activate configuration data.
Clip Type Connection for Easy Maintenance
- Easy access to water pump and strainer (front panel)
- Clip type connection for components
Flexible Refrigerant Piping Design
Long piping length and 3 Way piping enable flexible design and easy installation.
PRODUCTS
R32 MONOBLOC
Excellent Performance & Efficiency
User Convenience
Easy Installation & Maintenance
* Detailed description for each function is presented on pages 26 ~ 43.
Energy Labeling
Monobloc Concept
The LG THERMA V R32 Monobloc is a fully packaged unit, where the indoor and outdoor units are combined as one module. This unit does not require refrigerant piping work since the Monobloc’s outdoor unit is connected exclusively to water piping. Further, hydronic components such as plate heat exchanger, expansion tank and water pump are included in the package.
Capacity Range (Heating & Cooling)
R32 Monobloc
Heating Capacity | ||||||
Cooling Capacity |
Operation Range (Heating & Cooling)
Ambient Temperature
Leaving Water Temperature
PRODUCT FEATURES
All in One Concept
THERMA V’s all in one concept and reduced weight allow for quicker and easier installations.
- LG provides fully packaged THERMA V Monobloc: additional hydronic components are included in the package
- Easier and quicker installation without refrigerant piping work
High Heating Performance even at Low Temperature
The R32 Monobloc provides excellent heating performance – especially at low ambient temperature. The heating capacity of THERMA V R32 Monobloc at low ambient temperature is 20% higher than the R410A Monobloc.
High Energy Efficiency
The energy label directive is a key factor in selecting a heating device in the European heating market. The R32 Monobloc type has an energy label rating (ErP) of A+++.
SCOP
ErP Energy Labeling
*Test Condition
Test procedure follows EN14825 (low temp.. average), based on the single-phase model line-up.
Reduced Noise Level
THERMA V R32 Monobloc boasts reduced noise levels compared to previous generations as well as everyday environments.
PRODUCT SPECIFICATION
R32 Monobloc
HM051M U43
HM071M U43
HM091M U43
Features
- High energy efficiency (SCOP4.45 / A+++)
- Excellent performance at low ambient temperature (100% @ -7°C)
- Wide operation range (ambient : -25 ~ 35°C / waterside : 15 ~ 65°C)
- R32 refrigerant with low GWP
- R1 scroll compressor
- Black Fin heat exchanger
- LG ThinQ
- KEYMARK / EHPA certification / MCS / Eurovent certification
Model Line-up
Category | Unit | 5.5 | Model Name Capacity (kW) 7.0 |
9.0 |
1 Phase Model 220 ~ 240V, 1Ø, 50Hz |
monobloc Unit | HM051M U43 | HM071M U43 | HM091M U43 |
Seasonal Energy
Space Heating (according to EN14825) | Average Climate Water Outlet 35°C | SCOP | W/W | 4.45 | 4.45 | 4.45 |
Seasonal Space Heating Efficiency (ηs) | % | 175 | 175 | 175 | ||
Seasonal Space Heating Eff. Class (A+++ to D scale) | – | A+++ | A+++ | A+++ | ||
AverageClimate Water Outlet 55°C | SCOP | – | 3.12 | 3.12 | 3.12 | |
Seasonal Space Heating Efficiency (ηs) | % | 122 | 122 | 122 | ||
Seasonal Space Heating Eff. Class (A+++ to D scale) | – | A+ | A+ | A+ |
Nominal Capacity and Nominal Power Input
Nominal Capacity | Heating | 7°C | 35°C | kW | 5.50 | 7.00 | 9.00 |
7°C | 55°C | 5.50 | 5.50 | 5.50 | |||
2°C | 35°C | 3.30 | 4.20 | 5.40 | |||
Cooling | 35°C | 18°C | 5.50 | 7.00 | 9.00 | ||
35°C | 7°C | 5.50 | 7.00 | 9.00 | |||
Nominal Power Input | Heating | 7°C | 35°C | kW | 1.22 | 1.56 | 2.15 |
7°C | 55°C | 2.04 | 2.04 | 2.04 | |||
2°C | 35°C | 0.94 | 1.20 | 1.54 | |||
Cooling | 35°C | 18°C | 1.20 | 1.56 | 2.14 | ||
35°C | 7°C | 1.96 | 2.59 | 3.46 | |||
COP |
Heating |
7°C | 35°C | W/W | 4.50 | 4.50 | 4.18 |
7°C | 55°C | 2.70 | 2.70 | 2.70 | |||
2°C | 35°C | 3.52 | 3.51 | 3.50 | |||
EER | Cooling | 35°C | 18°C | W/W | 4.60 | 4.50 | 4.20 |
35°C | 7°C | 2.80 | 2.70 | 2.60 |
Product Specification
Water Side | Operation Range (leaving water temperature) | Heating | Min. ~ Max. |
°CDB |
15 ~ 65 | ||
Cooling | 5 ~ 27 (16 ~ 27)2) | ||||||
DHW1) | 15 ~ 80 | ||||||
Piping Connections | Water Circuit | Inlet | mm (inch) | Male PT 25.4 (1) | |||
Outlet | mm (inch) | Male PT 25.4 (1) | |||||
Rated Water Flow Rate at LWT 35°C | LPM | 15.81 | 20.12 | 25.87 | |||
Refrigerant Side | Operation Range (outdoor temp.) | Heating | Min. ~ Max. | °CDB |
-25 ~ 35 | ||
Cooling | 5 ~ 48 | ||||||
Compressor | Quantity | EA | 1 | ||||
Type | – | Hermetic Sealed Scroll | |||||
Refrigerant | Type | – | R32 | ||||
GWP (global warming potential) | – | 675 | |||||
Precharged Amount | g | 1,400 | |||||
t-CO2 eq | – | 0.945 | |||||
Sound Power Level | Heating | Rated | dB(A) | 60 | |||
Sound Pressure Level (at 1m) | Heating | Rated | dB(A) | 50 | |||
Dimensions | Unit | W x H x D | mm | 1,239 x 834 x 330 | |||
Weight | Unit | kg | 91.0 | ||||
Power Supply | Voltage, Phase, Frequency | V, Ø, Hz | 220 ~ 240, 1, 50 | ||||
Rated Running Current | Heating | A | 5.4 | 6.9 | 9.6 | ||
Cooling | A | 5.3 | 6.9 | 9.5 | |||
Recommended Circuit Breaker | A | 16 | 20 | 25 | |||
Wiring Connections | Power Supply Cable (included earth, H07RN-F) |
mm2 x cores |
4.0 x 3C |
1) DHW 58 ~ 80°C operating is available only when the booster heater is operating.
2) When fan coil unit not used.
Note
- Due to our policy of innovation, some specifications may be changed without notification.
- Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
- The sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. NSound power level is measured on the rated condition in the reverberation rooms by ISO 9614 standard. Therefore, these values can be increased owing to ambient conditions during operation.
- Performances are in accordance with EN14511 and reflect ErP testing conditions. Above gives the declared values at rated conditions acc. ErP regulation. For max. capacities, refer to performance data.
• Rated running current: outdoor temp. 7°CDB / 6°CWB, LW T 35°C - This product contains fluorinated greenhouse gases.
Performance Table for Heating Operation
Maximum Heating Capacity (Including Defrost Effect)
HM051M U43
Outdoor Temperature | LWT 30°C | LWT 35°C | LWT 40°C | LWT 45°C | LWT 50°C | LWT 55°C | LWT 60°C | LWT 65°C |
TC | TC | TC | TC | TC | TC | TC | TC | |
-25°C DB | 3.79 | 3.67 | 3.54 | 3.42 | – | – | – | – |
-20°C DB | 4.22 | 4.09 | 3.96 | 3.83 | 3.70 | – | – | – |
-15°C DB | 4.66 | 4.52 | 4.38 | 4.25 | 4.11 | 3.97 | – | – |
-7°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | – |
-4°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
-2°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
2°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
7°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
10°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
15°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
18°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
20°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
35°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
HM071M U43
Outdoor Temperature | LWT 30°C TC |
LWT 35°C TC |
LWT 40°C TC |
LWT 45°C TC |
LWT 50°C TC |
LWT 55°C TC |
LWT 60°C TC |
LWT 65°C TC |
-25°C DB | 4.82 | 4.67 | 4.51 | 4.36 | – | – | – | – |
-20°C DB | 5.38 | 5.21 | 5.05 | 4.88 | 4.72 | – | – | – |
-15°C DB | 5.93 | 5.76 | 5.58 | 5.41 | 5.23 | 5.06 | – | – |
-7°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | – |
-4°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
-2°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
2°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
7°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
10°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
15°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
18°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
20°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
35°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
HM091M U43
Outdoor Temperature | LWT 30°C | LWT 35°C | LWT 40°C | LWT 45°C | LWT 50°C | LWT 55°C | LWT 60°C | LWT 65°C |
TC | TC | TC | TC | TC | TC | TC | TC | |
-25°C DB | 6.20 | 6.00 | 5.80 | 5.60 | – | – | – | – |
-20°C DB | 6.91 | 6.70 | 6.49 | 6.28 | 6.06 | – | – | – |
-15°C DB | 7.63 | 7.40 | 7.18 | 6.95 | 6.73 | 6.50 | – | – |
-7°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | – |
-4°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
-2°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
2°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
7°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
10°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
15°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
18°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
20°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
35°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
Note
- DB : Dry Bulb Temperature (°C), LW T : Leaving Water Temperature (°C), LPM: Liters Per Minute (ℓ/min), TC: Total Capacity (kW)
- Direct interpolation is permissible. Do not extrapolate.
- The measuring procedure follows EN-14511.
• Rated values are based on standard conditions and it can be found on specifications.
• Above table values may not be matched according to installation conditions. Except for rated value, the performance is not guaranteed.
• In accordance with the test standard (or nations), the rating will vary slightly. - The shaded areas are not guaranteed continuous operation.
Performance Table for Cooling Operation
Maximum Cooling Capacity
HM051M U43
Outdoor Temperature | LWT 7°C | LWT 10°C | LWT 13°C | LWT 15°C | LWT 18°C | LWT 20°C | LWT 22°C |
TC | TC | TC | TC | TC | TC | TC | |
10°C DB | 5.16 | 5.65 | 6.14 | 6.47 | 6.96 | 7.29 | 7.62 |
20°C DB | 5.29 | 5.59 | 5.89 | 6.08 | 6.38 | 6.58 | 6.77 |
30°C DB | 5.43 | 5.53 | 5.63 | 5.69 | 5.79 | 5.86 | 5.92 |
35°C DB | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 | 5.50 |
40°C DB | 5.57 | 5.50 | 5.43 | 5.38 | 5.31 | 5.27 | 5.22 |
45°C DB | 5.64 | 5.50 | 5.36 | 5.27 | 5.13 | 5.04 | 4.94 |
HM071M U43
Outdoor Temperature | LWT 7°C | LWT 10°C | LWT 13°C | LWT 15°C | LWT 18°C | LWT 20°C | LWT 22°C |
TC | TC | TC | TC | TC | TC | TC | |
10°C DB | 6.56 | 7.19 | 7.82 | 8.24 | 8.86 | 9.28 | 9.70 |
20°C DB | 6.74 | 7.11 | 7.49 | 7.74 | 8.12 | 8.37 | 8.62 |
30°C DB | 6.91 | 7.04 | 7.16 | 7.25 | 7.37 | 7.46 | 7.54 |
35°C DB | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 | 7.00 |
40°C DB | 7.09 | 7.00 | 6.91 | 6.85 | 6.76 | 6.70 | 6.65 |
45°C DB | 7.18 | 7.00 | 6.82 | 6.70 | 6.53 | 6.41 | 6.29 |
HM091M U43
Outdoor Temperature | LWT 7°C | LWT 10°C | LWT 13°C | LWT 15°C | LWT 18°C | LWT 20°C | LWT 22°C |
TC | TC | TC | TC | TC | TC | TC | |
10°C DB | 8.44 | 9.24 | 10.05 | 10.59 | 11.40 | 11.93 | 12.47 |
20°C DB | 8.66 | 9.15 | 9.63 | 9.95 | 10.44 | 10.76 | 11.08 |
30°C DB | 8.89 | 9.05 | 9.21 | 9.32 | 9.48 | 9.59 | 9.69 |
35°C DB | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 | 9.00 |
40°C DB | 9.11 | 9.00 | 8.89 | 8.81 | 8.70 | 8.62 | 8.54 |
45°C DB | 9.23 | 9.00 | 8.77 | 8.62 | 8.39 | 8.24 | 8.09 |
Note
- DB: Dry Bulb Temperature (°C), LW T: Leaving Water Temperature (°C), LPM: Liters Per Minute (ℓ/min), TC : Total Capacity (kW)
- Direct interpolation is permissible. Do not extrapolate.
- The measuring procedure follows EN-14511.
• Rated values are based on standard conditions and it can be found on specifications.
• Above table values may not be matched according to installation conditions. Except for the rated value, the performance is not guaranteed.
• In accordance with the test standard (or nations), the rating will vary slightly.
Drawings
Category | Unit | 5.5 | Model Name Capacity (kW) 7.0 |
9.0 |
1 Phase Model 20 ~ 240V, 1Ø, 50Hz |
Monobloc Unit | HM071M U43 | HM071M U43 | HM091M U43 |
HM051M U43
HM071M U43
HM091M U43
1 | Entering Water Pipe | Male PT 1 inch |
2 | Leaving Water Pipe | Male PT 1 inch |
3 | Strainer | Filtering and stacking particles inside circulating water |
4 | Top Cover | – |
5 | Front Panel | – |
6 | Side Panel | – |
7 | Low Voltage | Accessory kit cables |
8 | Unit Power | Outdoor entry power cable |
9 | Water Pump | – |
10 | Plate Heat Exchanger | Heat exchange between refrigerant and water |
11 | Pressure Gauge | Indicates circulating water pressure |
12 | Safety Valve | Open at water pressure 3bar |
13 | Indoor Control Box | Indoor PCB and terminal blocks |
14 | Outdoor Control Box | Outdoor PCB and terminal blocks |
R32 Monobloc
HM121M U33
HM141M U33
HM161M U33
HM123M U33
HM143M U33
HM163M U33
Features
- High energy efficiency (SCOP 4.45 / A+++)
- Excellent performance at low ambient temperature (100% @ -7°C)
- Wide operation range (ambient : -25 ~ 35°C / waterside : 15 ~ 65°C)
- R32 refrigerant with low GWP
- R1 scroll compressor
- Black Fin heat exchanger
- LG ThinQ
- KEYMARK / EHPA
1)certification / MCS / Eurovent certification
1) Approved model by EHPA: HM123M U33, HM143M U33, HM163M U33.
Model Line-up
Category | Unit | 12.0 | Model Name Capacity (kW) 14.0 |
16.0 |
1 Phase Model 220 ~ 240V, 1Ø, 50Hz |
Monobloc Unit | HM121M U33 | HM141M U33 | HM161M U33 |
3 Phase Model 380 ~ 415V, 3Ø, 50Hz |
HM123M U33 | HM143M U33 | HM163M U33 |
Seasonal Energy
Space Heating (according to EN14825) |
Average Climate Water Outlet 35°C | SCOP | W/W | 4.45 | 4.45 | 4.45 |
Seasonal Space Heating Efficiency (ηs) | % | 175 | 175 | 175 | ||
Seasonal Space Heating Eff. Class (A+++ to D scale) | – | A+++ | A+++ | A+++ | ||
Average Climate Water Outlet 55°C | SCOP | – | 3.18 | 3.18 | 3.18 | |
Seasonal Space Heating Efficiency (ηs) | % | 124 | 124 | 124 | ||
Seasonal Space Heating Eff. Class (A+++ to D scale) | – | A+ | A+ | A+ |
Nominal Capacity and Nominal Power Input
Nominal Capacity | Heating | 7°C | 35°C |
kW |
12.00 | 14.00 | 16.00 |
7°C | 55°C | 12.00 | 12.00 | 12.00 | |||
2°C | 35°C | 11.00 | 12.00 | 13.80 | |||
Cooling | 35°C | 18°C | 12.00 | 14.00 | 16.00 | ||
35°C | 7°C | 12.00 | 14.00 | 16.00 | |||
Nominal Power Input | Heating | 7°C | 35°C |
kW |
2.61 | 3.11 | 3.64 |
7°C | 55°C | 4.29 | 4.29 | 4.29 | |||
2°C | 35°C | 3.13 | 3.42 | 3.94 | |||
Cooling | 35°C | 18°C | 2.61 | 3.26 | 4.00 | ||
35°C | 7°C | 4.44 | 5.38 | 6.40 | |||
COP | Heating | 7°C | 35°C | W/W |
4.60 | 4.50 | 4.40 |
7°C | 55°C | 2.80 | 2.80 | 2.80 | |||
2°C | 35°C | 3.52 | 3.51 | 3.50 | |||
EER | Cooling | 35°C | 18°C | W/W |
4.60 | 4.30 | 4.00 |
35°C | 7°C | 2.70 | 2.60 | 2.50 |
Product Specification
Water Side | Operation Range (leaving water temperature) | Heating | Min. ~ Max. |
°CDB |
15 ~ 65 | |||||
Cooling | 5 ~ 27 (16 ~ 27)2) | |||||||||
DHW1) | 15 ~ 80 | |||||||||
Piping Connections | Water Circuit | Inlet | mm (inch) | Male PT 25.4 (1) | ||||||
Outlet | mm (inch) | Male PT 25.4 (1) | ||||||||
Rated Water Flow Rate at LWT 35°C | LPM | 34.50 | 40.25 | 46.00 | 34.50 | 40.25 | 46.00 | |||
Refrigerant Side |
Operation Range (outdoor temp.) | Heating | Min. ~ Max. | °CDB |
-25 ~ 35 | |||||
Cooling | 5 ~ 48 | |||||||||
Compressor | Quantity | EA | 1 | |||||||
Type | – | Hermetic Sealed Scroll | ||||||||
Refrigerant | Type | – | R32 | |||||||
GWP (global warming potential) | – | 675 | ||||||||
Precharged Amount | g | 2,400 | ||||||||
t-CO2 eq | – | 1.620 | ||||||||
Sound Power Level | Heating | Rated | dB(A) | 63 | ||||||
Sound Pressure Level (at 1m) | Heating | Rated | dB(A) | 52 | ||||||
Dimensions | Unit | W x H x D | mm | 1,239 x 1,380 x 330 | ||||||
Weight | Unit | kg | 124.5 | |||||||
Power Supply | Voltage, Phase, Frequency | V, Ø, Hz | 220 ~ 240, 1, 50 | 380 ~ 415, 3, 50 | ||||||
Rated Running Current | Heating | A | 11.6 | 13.8 | 16.1 | 3.8 | 4.6 | 5.4 | ||
Cooling | A | 11.6 | 14.4 | 17.7 | 3.8 | 4.8 | 5.9 | |||
Recommended Circuit Breaker | A | 40 | 16 | |||||||
Wiring Connections | Power Supply Cable (included earth, H07RN-F) |
mm2 x cores | 6.0 x 3C | 4.0 x 5C |
1) DHW 58 ~ 80°C operating is available only when the booster heater is operating.
2) When the fan coil unit not used.
Note
- Due to our policy of innovation, some specifications may be changed without notification.
- Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
- The sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard. Sound power level is measured on the rated condition in the reverberation rooms by ISO 9614 standard. Therefore, these values can be increased owing to ambient conditions during operation.
- Performances are in accordance with EN14511 and reflect ErP testing conditions. Above gives the declared values at rated conditions acc. ErP regulation. For max. capacities, refer to performance data.
• Rated running currently: outdoor temp. 7°CDB / 6°CWB, LW T 35°C - This product contains fluorinated greenhouse gases.
Performance Table for Heating Operation
Maximum Heating Capacity (Including Defrost Effect)
HM121M U33 / HM123M U33
Outdoor Temperature | LWT 30°C | LWT 35°C | LWT 40°C | LWT 45°C | LWT 50°C | LWT 55°C | LWT 60°C | LWT 65°C |
TC | TC | TC | TC | TC | TC | TC | TC | |
-25°C DB | 8.75 | 8.50 | 8.25 | 8.00 | – | – | – | – |
-20°C DB | 10.13 | 10.00 | 9.88 | 9.75 | 9.63 | – | – | – |
-15°C DB | 11.50 | 11.50 | 11.50 | 11.50 | 11.50 | 11.50 | – | – |
-7°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | – |
-4°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
-2°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
2°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
7°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
10°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
15°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
18°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
20°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
35°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
HM141M U33 / HM143 U33
Outdoor Temperature | LWT 30°C TC |
LWT 35°C TC |
LWT 40°C TC |
LWT 45°C TC |
LWT 50°C TC |
LWT 55°C TC |
LWT 60°C TC |
LWT 65°C TC |
-25°C DB | 9.25 | 9.00 | 8.75 | 8.50 | – | – | – | – |
-20°C DB | 10.63 | 10.50 | 10.38 | 10.25 | 10.13 | – | – | – |
-15°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | – | – |
-7°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | – |
-4°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
-2°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
2°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
7°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
10°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
15°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
18°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
20°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
35°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
HM161M U33 / HM163 U33
Outdoor Temperature | LWT 30°C | LWT 35°C | LWT 40°C | LWT 45°C | LWT 50°C | LWT 55°C | LWT 60°C | LWT 65°C |
TC | TC | TC | TC | TC | TC | TC | TC | |
-25°C DB | 10.50 | 10.00 | 9.50 | 9.00 | – | – | – | – |
-20°C DB | 12.30 | 11.75 | 11.44 | 11.13 | 10.75 | – | – | – |
-15°C DB | 14.10 | 13.50 | 13.38 | 13.25 | 13.13 | 13.00 | – | – |
-7°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | – |
-4°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
-2°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
2°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
7°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
10°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
15°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
18°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
20°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
35°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Note
- DB : Dr y Bulb Temperature (°C), LW T : Leaving Water Temperature (°C), LPM : Liters Per Minute (ℓ/min), TC : Total Capacity (kW)
- Direct interpolation is permissible. Do not extrapolate.
- Measuring procedure follows EN-14511.
• Rated values are based on standard conditions and it can be found on specifications.
• Above table values may not be matched according to installation conditions. Except for rated value, the performance is not guaranteed.
• In accordance with the test standard (or nations), the rating will vary slightly. - The shaded areas are not guaranteed continuous operation.
Performance Table for Cooling Operation
Maximum Cooling Capacity
HM121M U33 / HM123M U33
Outdoor Temperature | LWT 7°C | LWT 10°C | LWT 13°C | LWT 15°C | LWT 18°C | LWT 20°C | LWT 22°C |
TC | TC | TC | TC | TC | TC | TC | |
10°C DB | 11.25 | 12.33 | 13.40 | 14.12 | 15.20 | 15.91 | 16.63 |
20°C DB | 11.55 | 12.20 | 12.84 | 13.27 | 13.92 | 14.35 | 14.78 |
30°C DB | 11.85 | 12.07 | 12.28 | 12.42 | 12.64 | 12.78 | 12.93 |
35°C DB | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 | 12.00 |
40°C DB | 12.15 | 12.00 | 11.85 | 11.75 | 11.59 | 11.49 | 11.39 |
45°C DB | 12.30 | 12.00 | 11.69 | 11.49 | 11.19 | 10.99 | 10.78 |
HM141M U33 / HM143 U33
Outdoor Temperature | LWT 7°C | LWT 10°C | LWT 13°C | LWT 15°C | LWT 18°C | LWT 20°C | LWT 22°C |
TC | TC | TC | TC | TC | TC | TC | |
10°C DB | 13.13 | 14.38 | 15.64 | 16.47 | 17.73 | 18.57 | 19.40 |
20°C DB | 13.48 | 14.23 | 14.98 | 15.48 | 16.24 | 16.74 | 17.24 |
30°C DB | 13.83 | 14.08 | 14.33 | 14.49 | 14.75 | 14.91 | 15.08 |
35°C DB | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 | 14.00 |
40°C DB | 14.18 | 14.00 | 13.82 | 13.70 | 13.53 | 13.41 | 13.29 |
45°C DB | 14.35 | 14.00 | 13.64 | 13.41 | 13.05 | 12.82 | 12.58 |
HM161M U33 / HM163 U33
Outdoor Temperature | LWT 7°C | LWT 10°C | LWT 13°C | LWT 15°C | LWT 18°C | LWT 20°C | LWT 22°C |
TC | TC | TC | TC | TC | TC | TC | |
10°C DB | 15.00 | 16.43 | 17.87 | 18.83 | 20.26 | 21.22 | 22.17 |
20°C DB | 15.40 | 16.26 | 17.12 | 17.70 | 18.56 | 19.13 | 19.70 |
30°C DB | 15.80 | 16.09 | 16.37 | 16.57 | 16.85 | 17.04 | 17.23 |
35°C DB | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
40°C DB | 16.20 | 16.00 | 15.80 | 15.66 | 15.46 | 15.32 | 15.19 |
45°C DB | 16.40 | 16.00 | 15.59 | 15.32 | 14.92 | 14.65 | 14.38 |
Note
- DB: Dry Bulb Temperature (°C), LW T: Leaving Water Temperature (°C), LPM: Liters Per Minute (ℓ/min), TC : Total Capacity (kW)
- Direct interpolation is permissible. Do not extrapolate.
- The measuring procedure follows EN-14511.
• Rated values are based on standard conditions and it can be found on specifications.
• Above table values may not be matched according to installation conditions. Except for the rated value, the performance is not guaranteed.
• In accordance with the test standard (or nations), the rating will vary slightly.
Drawings
Category | Unit | 12.0 | Model Name Capacity (kW) 14.0 |
16.0 |
1 Phase Model 220 ~ 240V, 1Ø, 50Hz |
Monobloc Unit | HM121M U33 | HM141M U33 | HM161M U33 |
3 Phase Model 380 ~ 415V, 3Ø, 50Hz |
HM123M U33 | HM143M U33 | HM163M U33 |
HM121M U33 / HM141M U33 / HM161M U33
HM123M U33 / HM143M U33 / HM163M U33
1 | Entering Water Pipe | Male PT 1 inch |
2 | Leaving Water Pipe | Male PT 1 inch |
3 | Strainer | Filtering and stacking particles inside circulating water |
4 | Top Cover | – |
5 | Front Panel | – |
6 | Side Panel | – |
7 | Low Voltage | Accessory kit cables |
8 | UNIT Power | Outdoor entry power cable |
9 | Water Pump | – |
10 | Plate Heat Exchanger | Heat exchange between refrigerant and water |
11 | Pressure Gauge | Indicates circulating water pressure |
12 | Safety Valve | Open at water pressure 3bar |
13 | Indoor Control Box | Indoor PCB and terminal blocks |
14 | Outdoor Control Box | Outdoor PCB and terminal blocks |
Electric Back up Heater
HA031M E1
HA061M E1
HA063M E1
Product Specification
Back up Heater | Type | – | Sheath | ||
Number of Heating Coil | EA | 1 | 2 | 3 | |
Capacity Combination | kW | 3.0 | 3.0 + 3.0 | 2.0 + 2.0 + 2.0 | |
Operation | – | Automatic | |||
Heating Steps | Step | 1 | 2 | 1 | |
Power Supply | V, Ø, Hz | 220 ~ 240, 1, 50 | 380 ~ 415, 3, 50 | ||
Dimensions (W x H x D) | mm | 210 x 607 x 217 | |||
Net Weight (unit) | kg | 13.0 | 13.8 | 14.1 | |
Wiring Connections | Power Supply Cable (included earth, H07RN-F) | mm2 x cores | 1.5 x 3C | 4.0 x 3C | 2.5 x 4C |
Communication Cable (H07RN-F) | mm2 x cores | 0.75 x 2C | 0.75 x 4C | 0.75 x 2C |
Note
- Due to our policy of innovation, some specifications may be changed without notification.
- Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
1 | Leaving Water Pipe | Male PT 1 inch |
2 | Entering Water Pipe | Male PT 1 inch |
3 | Control Box | Circuit breaker, Magnetic switch, Terminal blocks |
4 | Thermal Switch | Cut-off power input to E/heater at 90°C |
5 | Air Vent | Air purging when charging water |
6 | Electric Heater | Refer the related information |
7 | Back up Heater Outlet Sensor (S13) | Connect to unit (heat pump) |
ACCESSORIES
Accessories Provided by LG
Sensors |
Room Temperature Sensor | PQRSTA0 |
All except |
Room Temperature Based Control | To detect room air temperature for room temperature based control |
• Max. wire length: 15m | |
2nd Circuit Thermistor | PRSTAT5K10 | All except for R410A IWT and High temp. |
2nd Circuit (mixing circuit) | To detect 2nd circuit temperature when using 2nd circuit function |
• 5kΩ thermistor, 10m | ||
Domestic Hot Water Sensor | PHRSTA0 | All except for IWT and High temp. models | Domestic Hot Water Heating | To detect DHW tank temperature | • Included in PHLTA kit | ||
Valves | 3 Way Valve | OSHA-3V | All except for IWT models |
Domestic Hot Water Heating | To divert water flow between space heating and DHW heating |
• Size : DN 20 G 1″ connection, male threaded | |
Thermostatic Mixing Valve | OSHA-MV |
Regardless of model |
Domestic Hot Water Supply |
To blend hot water with cold water for ensuring constant, safe shower and bath outlet temp. |
• Size : 3/4” DN20 male threaded | ||
OSHA-MV1 | • Size : 1” DN25 male threaded | ||||||
DHW Tanks | Domestic Hot Water Tank (single coil) | OSHW-200F |
|
All except for IWT models |
Domestic Hot Water Heating | To generate and store domestic hot water | • Storage volume : 200L, 300L, 500L • Type : Internal double coil • Material : Stainless steel • Capacity of booster heater : 2.4kW |
OSHW-300F | |||||||
OSHW-500F | |||||||
Domestic Hot Water Tank (double coil) | OSHW-300FD |
|
All except for IWT and High temp. models | • Storage volume: 300L • Type : Internal double coil • Material : Stainless steel • Capacity of booster heater : 2.4kW | |||
Installation Kits |
Domestic Hot Water Tank Kit |
PHOTO (1Ø, split) |
All except for IWT and High temp. models | Domestic Hot Water Heating | To operate with DHW tank | • Parts included: DHW tank sensor (thermistor), | |
PHLTC (3Ø, split) | |||||||
PHLTB (monobloc) |
• Parts included: DHW tank sensor (thermistor), Circuit breaker, Relay, Multi harness | ||||||
Solar Thermal Kit | PHILA | All except for IWT, Hydrosplit and High temp. models | Solar Thermal Heat Utilization | To operate with a solar thermal system | • Length of thermistor : 12m |
Installation Kits | Electric Back Up Heater | HA031M E1 | R32 Monobloc and R32 Silent Monobloc (HA063M E1 is not applicable for R32 Silent Monobloc) |
Capacity Back Up & Emergency Operation |
To supplement insufficient capacity | • Heater capacity : 3kW • Number of heating coil : 1EA (3.0kW) • Size (W x H x D) : 210 x 607 x 217 • Power : 220 ~ 240V, 1Ø | |
HA061M E1 |
• Heater capacity : 6k • Number of heating coil : 2EA (3.0 + 3.0kW) • Size (W x H x D) : 210 x 607 x 217 • Power : 220 ~ 240V, 1Ø | ||||||
HA063M E1 | • Heater capacity : 6kW • Number of heating coil : 3EA (2.0 + 2.0 + 2.0kW) • Size (W x H x D) : 210 x 607 x 217 • Power : 380 ~ 415V, 3Ø | ||||||
Vessel | Buffer Tank for Space Heating | OSHB-40KT |
R32 IWT |
– |
To provide the buffer volume of water to the heating circuit | • Volume: 40L • Size (W x H x D) : 518 x 560 x 175 | |
Expansion Vessel for DHW | OSHE-12KT | R32 IWT |
– |
To absorb the volume changes by the temperature of water for the DHW circuit | • Volume : 8L • Connection: 3/4” • Max. pressure : 10 bar • Size (W x H x D) : 416 x 238 x 502 | ||
ETC | Extension Wire for Wire Remote Controller | PZCWRC1 | All except for R410A IWT |
– |
To extend wire between wired remote controller and indoor unit | • Length: 10m | |
Extension Cable forWi-Fi Modem | PWYREW000 | All except |
Wi-Fi Control via LG ThinQ | To extend wire between WI-Fi modem and indoor unit | • Length: 10m | ||
2 Remote Control Wire |
PZCWRC2 | All except for R410A IWT |
2 Remote Control | To connect two remote controllers on the one indoor unit | • Length : 0.25m | ||
Drain Pan | PHDPB | R32 Split, R410A Split | Cooling Operation | To collect condensed water in indoor unit when cooling operation |
– | ||
PHDPC | R32 Hydrosplit | ||||||
Cover Plate | PDC-HK10 | R32 Hydrosplit, R32 Split, R32 IWT, R410A Split |
– |
To fill the blank space of the indoor unit front panel when the remote controller is relocated indoors. |
– |
Accessories Provided by LG
Remote Controller | Wired Remote Controller | PREMTW101 |
|
All except for the R410A IWT model | 2 Remote Control | To control AWHP using two remote controller (additional remote controller) | • New modern design 4.3 inch color LCD display • Information displayed with simple graphic, icon & text • Built-in temperature sensor • Size (W x H x D) : 120 x 120 x 16 • Extension cable (PZCWRC1, 10m) and 2 remote cable (PZCWRC2, 0.25m) are included |
Central Controller | AC Ez Touch | PACEZA000 | All except for R410A IWT model | Centralized Control | To control AWHP using LG central controller | • 5 inch color display • User-friendly control with iconographic interface (touch screen) • Max. 32 unit control • Total 200 schedule events (weekly / monthly / yearly / exception day) • Operation history • Remote controller lock (all, temp, mode) • PC access supported (IPv6 supported) • DI 1EA (emergency stop only) • Size (W x H x D) : 137 x 121 x 25 | |