SEALEY LP14 Infrared Gas Heater Instructions
LP14 Infrared Gas Heater
INFRARED GAS HEATER
Model No: LP14
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will if used according to these instructions and properly maintained, give you years of trouble-free performance.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
SAFETY INSTRUCTIONS
1.1. GENERAL SAFETY
preferably outdoors, and away from any heat sources (including strong sunlight). Rectify the cause of leakage.
INTRODUCTION & SPECIFICATION
Ceramic plaque type heater. Steel tube stands with a built-in handle. Heat output from 9,200 to 17,000Btu/hr. Supplied with 1.5mtr hose and regulator. DVGW Approved. Gas bottle not included.
Model No. . . . . . . . . . . . . . . . . . . . . . . . . . . . .LP14
Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Propane
Output. . . . . . . . . . . . . . . . . . . . .9,200-17,000Btu/hr
Fuel Consumption. . . . . . . . . . . . . .0.216-0.400kg/hr
CONTENTS
3.1. Content
3.1.1. Check content against the list below and, in the event of shortages or damage, contact your supplier.
Contents:
- Heater stand and mounting bolts
- Heater assembly
- Hose and gas bottle regulator
ASSEMBLY
4.1. Assembly (See fig.2)
4.1.1 Attach the stand to the heater assembly using the two bolts supplied.
4.1.2. Fit the regulator to the bottle by screwing the POL nut anticlockwise into the port of the gas bottle valve. Tighten the nut with a spanner.
4.1.3. Attach one end of the gas hose to the threaded outlet on the regulator (note that the fitting has a reverse thread). Attach the other end of the gas hose to the threaded heater valve inlet (note that the fitting has a reverse thread). Ensure the hose is routed so that it does not touch any part of the heater, which will become hot during operation.
4.1.4. Open the bottle valve and, using soapy water, check all joints for leaks.
OPERATION
5.1. Siting the heater.
5.1.1 DO NOT use the heater where there are flammable liquids, solids, or gases such as paint solvents, etc. Ensure there are no flammable
or combustible materials within 2 meters of the heater and that nothing, including walls, is less than 500mm from any surface of the
heater. Always ensure that the heater is facing away from the gas bottle.
5.2. Lighting heater
5.2.1 Open the gas bottle valve.
5.2.2. Push the heater control knob down and turn it anticlockwise to the center (full on) position and keep it held down.
5.2.3. After a few seconds bring a flame up to the bottom edge of the burner.
5.2.4. After the gas ignites keep the knob held down for a further 20 seconds then turn the control knob anticlockwise again to reduce the heat output to the required level.
5.3. Turning off the heater
5.3.1 Turn the heater control knob clockwise to the full-on position then push the knob down and continue to turn it clockwise to the off
position.
5.3.2. Close the gas bottle valve.
5.4. Changing the propane bottle
5.4.1. Ensure the bottle valve is closed and then unscrew the POL nut and remove the regulator.
5.4.2. Fit regulator to new propane bottle. Check for gas leaks as in 4.1.4.
INFRARED GAS HEATER
Model: LP14
90/396/EEC Gas Appliance Directive
93/68/EEC CE Marking Directive
Declaration of Conformity We, the sole importer into the UK, declare that the product listed here is in conformity with the following standards and directives.
The construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to Jack Sealey Ltd.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
NOTE: It is our policy to continually improve products and as such, we reserve the right to alter data, specifications, and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalog and latest promotions call us on 01284 757525 and leave your full name, address and postcode.