Panasonic FV-0510VSL1 Ventilating Fan with LED Light Instruction Manual

Panasonic FV-0510VSL1 Ventilating Fan with LED Light

READ AND SAVE THESE INSTRUCTIONS

Thank you for purchasing this Panasonic product.
Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION” (P.2~4) of this manual before use. Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference.

GENERAL SAFETY INFORMATION

For Your Safety
To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions.
Explanation of symbol word panels
The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.
 WARN I N G: I injury Denotes or a death. the potential hazard that could result in serious _
Denotes a hazard that could result in minor injury.
This symbol is used to alert users not to disassemble the equipment. e This equipment symbol is used to alert grounding users to the terminal. make sure of grounding when using the
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any .. questions, contact the manufacturer.
Before servicing or cleaning the unit, switch power off at the service panel and lock the .. service disconnecting means to prevent power from being switched on accidentally.

  • Installation work and electrical wiring must be done by a qualified person(s) in
  •  accordance with all applicable codes and standards, including fire-rated construction.
  •  Sufficient air is needed for proper combustion and exhausting of gases through the .. flue (chimney) of fuel-burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
  • Conditioning Engineers (ASHRAE) and the local code authorities.
  •  When cutting or drilling into a wall or ceiling, do not damage metal objects, electrical .. wiring or other hidden utilities.
  • Ducted fans must always be vented to the outdoors.

WARNING 

  • These models are UL listed for tub and shower enclosures.
  •  A statement to the effect that when the product is to no longer be used, it must .. not be left in place but removed, to prevent it from possibly falling.
  •  The ceiling joist or wall stud must be subjected to static load more than five times the .. weight of the product.
  • Install the fan at least 1.5 m (5 feet) above the floor, and the fan must be installed .. above a counter or major appliances that serve as a barrier.
  • If this unit is to be installed over a tub or shower, it must be marked as appropriate .. for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) –
  •  The product must be properly grounded.
  •  Do not install with a method that is not approved in the instructions.
  •  Do not use this fan with any solid-state speed control device. Solid-state controls \:::I may cause harmonic distortion which can cause motor humming noise.
  •  Not to be installed in a ceiling thermally insulated to a value greater than R60.
  •  Do not disassemble the unit for reconstruction. It may cause fire or electric shock.
  • Follow all local electrical and safety codes, as well as the National Electrical .. Code (NEC) and the Occupation Safety and Health Act (OSHA).
  • Make sure that the electric service supply voltage is AC 120 V, 60 Hz.
  • Always disconnect the power source before working on or near the fan, motor, .. light fixture, or junction box.
  • Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals
  • or other objects.
  • The special-purpose or dedicated parts, such as mounting .. fixtures, must be used if such parts are provided.
  • Please wear gloves to protect your hands during installation.
  •  Do not install this ventilating fan where interior room \::: I temperature may exceed 104 °F (40 °C).
  • For general ventilating use only. Do not use to
  •  exhaust hazardous or explosive materials and vapors.
  • Do not kink the supply wiring.
  • Not for use in the cooking area. (Fig. A)

NOTICE 

  • Provide make up air for proper ventilation.
  • When one switch is connected with two or more products in parallel, the unit may not function. Therefore, parallel connection must not be allowed.
  •  Do not install the product where ducts are configured as shown in below.

DESCRIPTION

These products are listed by UL under UL file No. E78414. These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The lighting unit is an energy-saving LED lighting device that uses one 10 W LED lamps and produces almost the same illumination as a standard 40 W incandescent lamp.
FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15B of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning this product on and off, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and receiver.
  •  Connect equipment into an outlet on a circuit different from that to which the receiver is connected.
  •  Consult the dealer or an experienced radio/TV technician for help.
    Warning: This equipment must be installed by a qualified person in accordance with the provided installation instructions; and all applicable codes and standards. Also, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • SDoC Responsible Party: Panasonic Corporation of North America
  • Two Riverfront Plaza, Newark, NJ 07102 Customer Call Support: 1-866-292-7299
  • This device complies with Part 15B of the FCC Rules. Operation is subject to the following two conditions:
  •  This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Risk of Fire: Type IC-Inherently Protected.

UNPACKING
Unpack and carefully remove the product from the carton.
Refer to the supplied accessories list to verify that all parts are present.

SUPPLIED ACCESSORIES

DIMENSIONS

WIRING DIAGRAM

FEATURE

These products employ innovative, state-of-the-art technologies that provide a number of customizable unique features that lead to improved indoor air quality. Please read this manual first in order to realize the benefits of this customizable, modular fan.
Optimum ventilation performance:
Duct length, elbows, and other factors increase static pressure which can hinder the performance of most ventilation fans. These products utilize SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within the ducts. This feature allows the fan to perform as rated and avoid potential installation issues.
Outstanding energy savings:
These products are built using DC motor technology. The DC motor is 30 %-70 % more energy efficient than the minimum ENERGY STAR requirements.
[For model : FV-051 0VSL 1]

* 2 The product will continue to run for about 20 minutes when detects the environment humidity is about 5 %RH lower than the humidity setting, then stop running.
Note:

  1. The product will also run when the environment humidity rises rapidly but does not reach the humidity setting, and stop after the delayed operation.
  2. induction humidity setting switch is stepless change between 30 o/oRH-80 %RH.
  3. The humidity detected by the sensor may differ from the value on your hygrometer.
  4. The product may be on and off caused by the unstable environment humidity, you can improve it by

PLEASE READ PRIOR TO INSTALLATION

[For model : FV-081 OVSSL 1]

Spot and continuous ventilation
This product is designed to run continuously ensuring a healthy environment at low airflow levels 24 hours a day. By utilizing the CustomVent Multi-speed module the product is built to run continuously at a pre-set lower level (0, 30, 40, 50, 60, 70 CFM). The setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and the switch indication on page 6.

This product is also built to take care of the homeowner’s spot ventilation needs when the room is occupied and kicks up to a maximum level of 100 CFM when the control switch is turned on.

INSTALLATION I {JOIST MOUNTING)
  1. Before installation, please remove the tape which protects the damper during shipping and accessory screws from the adaptor and the tape which fixes the condensation sensor
    (FV-051 0VSCL 1 only), then check that the damper can open and close smoothly. (Fig.1) Note: Please remove the tape on the damper according to the direction of the arrow in Fig.1, otherwise, the damper may be pulled out.
  2. Open one knock-out hole on the junction box.
    NOTE: There are two knock-out holes, please open one which is convenient for wiring.INSTALLATION I (JOIST MOUNTING)
    screws (ST4.2X30), and fix the suspension bracket to joist with 2 long screws (ST4.2X30). (Fig.3)The screws for fixing suspension .. bracket should not be replaced by Nother screws, otherwise, the cord in PCB box may be damaged and cause fire.
  3. A 4-inch circular duct is needed to connect to the relevant part of the adaptor. Squeeze a circular exhaust duct to fit the adaptor, then slip it onto the adaptor and secure it with clamps, or ties and seal it with mastic or approved foil tape. (Fig.4)Note:
    If using 3 inch round duct, please purchase the 26 gauge steel Panasonic 4″ Oval – 3″ Round reducer from our representative.
  4. Remove junction box cover and secure conduit or stress relief to the opened knock-out hole. (Fig.4)
  5. Refer to wiring diagram (P.5), follow all the local electrical safety codes as well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires. (Fig.5)
  6. Finish ceiling work. Ceiling hole should be aligned with the inside edge of the flange. (Fig.6)
  7. Take out the mounting springs from clips.
  8. Connect the LED lamp wire to the fan body as shown in Fig.8 G).
  9. lnsert one mounting spring into the slot as shown in Fig.8 Cl). (If not, the grille may not be installed.)
  10. Fix the condensation sensor (FV-051 OVSCL 1 only) into the grille as shown in Fig.8 CJ). Note: Make sure the condensation sensor is fixed completely.
  11. Adjust Pick-A-Flow switch, Multi-speed switch (FV-081 OVSSL 1 only), Induction humidity setting switch (FV-051 OVSCL 1 only) as you want. (Refer to indication on P.6)
  12. insert the other mounting spring into the slot as shown and mount the grille to the fan body. (Fig.

Installation Wall mounting
  1. Before installation, please refer to step 1 to 2 of INSTALLATION I. (P.7)
  2. Fix the flange of the frame to stud by 2 long screws (ST4.2X30), and fix the suspension bracket to stud by 2 long screws (ST4.2X30). (Fig.10)
    • The adaptor of the product must be installed upward. (Fig.10)
    • The screws for fixing suspension bracket should not be replaced by other screws, otherwise, the cord in PCB box may be damaged and cause fire.

MAINTENANCE (CLEANING)

WARNING: Disconnect power source before working on the unit.
caution Routine maintenance must be done every year. Please wear gloves during the cleaning work. t<::’\. Do not immerse motor, LED lamp, \:)I condensation sensor in water when t<::’\. Do not soak resin parts in water over \:)1140 °F (60 °C). Never use gasoline, benzene, thinner or \:)I any other such chemicals for cleaning

  1. Clean grille. (Don’t put into water. Use non-abrasive kitchen detergent. Wipe dry with a clean cloth.) (Fig.12)
  2. Remove one mounting spring from the grille on the condensation sensor side. (Fig.13)
  3. Remove the other mounting spring. (Fig.14 Q))
  4. Take the LED lamp wire out to remove the grille. (Fig.14 ®)
  5. Reinstall grille, please refer to Fig.8~Fig.9 in P.9.

TROUBLESHOOTING GUIDE

Check according to the following table and correct the problem. If the fan still does not work correctly, please disconnect the power source and contact the dealer.

SPECIFICATION