Maytag MVW6200KW Top Load Washer with Deep Fill option – 4.8 cu ft User Guide

Dimension Guide
Maytag® Top Load Washer with Deep Fill option – 4.8 cu ft
White Available
MVW6200KW W11495336A

DETAILED PLANNING DIMENSIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS and INSTALLATION INSTRUCTIONS, located in your appliance’s Owner’s Manual, before installing and operating this appliance.

Electrical Requirements

MVW6200KW – 4.8 cu ft DOE (US) / 5.5 cu ft IEC (CAN)

Minimum Circuit 15 A
Amperage Rating 120 V AC only
Operating Voltage 60 Hz

Product Dimensions

MVW6200KW – 4.8 cu ft DOE (US) / 5.5 cu ft IEC (CAN)

in (minimum)

mm (minimum) in (maximum)

mm (maximum)

A Height (with feet) 42 1065 4211/16 1084
B Width 271/2 702

C Top of Lid Height (with feet) 38 968 383/4 984
D Depth 271/2 702

E Width of Lid 271/2 702

Product Dimensions

MVW6200KW – 4.8 cu ft DOE (US) / 5.5 cu ft IEC (CAN)

in (minimum) mm (minimum) in (maximum)

mm (maximum)

F Height of Lid 191/2 487

G Height with Lid Open 571/2 1455 583/4 1470
H Water Inlet Valves Height 381/4 972 40 1016
I Water Inlet Valves from Side 53/4 147

J Power Cord from Side 91/2 242

K Power Cord Height 371/2 953 381/4 972
Power Cord Length 62 1575

L Drain Hose Outlet Height 7 179 73/4 196
M Drain Hose Outlet from Side 4% 111

Drain Hose Length 42 1067

Diameter of Drain Hose 1 25

Recessed area or closet installation

NOTE: All 27″ wide washers should have 19″ clearance, while all 29″ wide washers should have 22″ clearance.
All Dimensions show recommended spacing allowed, except for closet door ventilation openings, which are minimum required.
This washer has been tested for installation with a spacing of 0″ (0 mm) clearance on the sides. Consider allowing more space for ease of installation and servicing, spacing for companion appliances, and clearances for walls, doors, and floor moldings. Add spacing of 1″ (25 mm) on all sides of the washer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in the door are required.