Makita DVC864L Cordless Vacuum Cleaner Instruction Manual

DVC864L Cordless Vacuum Cleaner
Instruction Manual

Read before use.

WARNING

  • This machine is not intended for use by persons including children with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
  • Children should be supervised to ensure that they do not play with the cleaner.
  • See the chapter “SPECIFICATIONS” for the type reference of the battery.
  • See the section “Installing or removing battery cartridge” for how to remove or install the battery.
  • When disposing of the battery cartridge, remove it from the tool and dispose of it in a safe place. Follow your local regulations relating to the disposal of batteries.
  • If the tool is not used for a long period of time, the battery must be removed from the tool.
  • Do not short the battery cartridge.
  • See the chapter “MAINTENANCE” for the appropriate details of precautions during user maintenance.

SPECIFICATIONS

Model: DVC864L
Standard filter type Powder filter (for dry dust)
Volume flow (air) (with BL1850B, e38 mm x 2.5 m hose) 2.1 m3/min
Vacuum (with BL1850B, e38 mm x 2.5 m hose) 98 hPa
Recoverable capacity 8 L
Dimensions (L x W x H) 366 mm x 334 mm x 368 mm
Rated voltage D.C. 36 V
Net weight 7.7 – 8.4 kg
Bluetooth® version 4.1 (Bluetooth low energy)
Frequency band 2,402 – 2,480 MHz
Maximum radio-frequency power 1.0 dBm (EIRP)
Transmission range Approximately 10 m
  • Due to our continuing program of research and development, the specifications herein are subject to change without notice.
  • Specifications and battery cartridges may differ from country to country.
  • The weight does not include accessories but battery cartridge(s). The lightest and heaviest combined weight of the appliance and battery cartridge(s) are shown in the table.

Applicable battery cartridge and charger

Battery cartridge BL1815N / BL1820B / BL1830B / BL1840B / BL1850B / BL1860B
Charger DC18RC / DC18RD / DC18RE / DC18SD / DC18SE / DC18SF / DC18SH
  • Some of the battery cartridges and chargers listed above may not be available depending on your region of residence.

WARNING: Only use the battery cartridges and chargers listed above. Use of any other battery cartridges and chargers may cause injury and/or fire.

The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Makita is under license.  Other trademarks and trade names are those of their respective owners.

Symbols

The followings show the symbols which may be used for the equipment. Be sure that you understand their meaning before use.

Read the instruction manual.
Take particular care and attention.
 Warning! The cleaner may contain hazardous dust.
 Never stand on the cleaner.
Dust class L (light). The cleaners are capable of picking up dust class L. Follow your country’s regulations relating to dust and to occupational health and safety.
Only for EU countries Due to the presence of hazardous components in the equipment, waste electrical and electronic equipment, accumulators and batteries may have a negative impact on the environment and human health. Do not dispose of electrical and electronic appliances or batteries with household waste! In accordance with the European Directive on waste electrical and electronic equipment and on accumulators and batteries and waste accumulators and batteries, as well as their adaptation to national law, waste electrical equipment, batteries, and accumulators should be stored separately and delivered to a separate collection point for municipal waste, operating in accordance with the regulations on environmental protection. This is indicated by the symbol of the crossed-out wheeled bin placed on the equipment.

Intended use

The tool is intended for collecting dry dust. The tool is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops, offices, and rental businesses.

Noise

The typical A-weighted noise level determined according to IEC60335-2-69:
Sound pressure level (LPA): 70 dB(A) or less Uncertainty (K): 2.5 dB(A)

The noise level under working may exceed 80 dB (A).

WARNING: Wear ear protection.

Vibration

The vibration total value (tri-axial vector sum) deter-mined according to IEC60335-2-69:
Vibration emission (ah.m) : 2.5 m/s2 or less Uncertainty (K) : 1.5 m/s’

NOTE: The declared vibration total value(s) has been measured in accordance with a standard test method and may be used for comparing one tool with another.
NOTE: The declared vibration total value(s) may also be used in a preliminary assessment of exposure.

WARNING: The vibration emission during actual use of the power tool can differ from the declared value(s) depending on the ways in which the tool is used especially what kind of workpiece is processed.
WARNING: Be sure to identify safety measures to protect the operator that is based on an estimation of exposure in the actual conditions of use (taking account of all parts of the operating cycle such as the times when the tool is switched off and when it is running idle in addition to the trigger time).

EC Declaration of Conformity

For European countries only
The EC declaration of conformity is included as Annex A to this instruction manual.

SAFETY WARNINGS

Cordless vacuum cleaner safety warnings

WARNING: IMPORTANT! READ CAREFULLY all safety warnings and all instructions BEFORE USE. Failure to follow the warnings and instructions may result in electric shock, fire, and/or serious injury.

  1. Before use, make sure that this cleaner must be used by people who have been adequately Instructed on the use of this cleaner.
  2. Before use, operators shall be provided with information, instruction, and training for the use of the machine and the substances for which it is to be used, including the safe method of removal and disposal of the material collected.
  3. Do not use the cleaner without the filter. Replace a damaged filter immediately.
  4. AVOID UNINTENTIONAL STARTING. Be sure the switch is OFF when installing the battery(ies).
  5. Do not attempt to pick up flammable materials, fireworks, lighted cigarettes, hot ashes, hot metal chips, sharp materials such as razors, needles, broken glass, or the like.
  6. NEVER USE THE CLEANER IN THE VICINITY OF GASOLINE, GAS, PAINT, ADHESIVES, OR OTHER HIGHLY EXPLOSIVE SUBSTANCES. The switch emits sparks when turned ON and OFF. And so does the motor commutator during operation. A dangerous explosion may result.
  7. Never vacuum up toxic, carcinogenic, combustible, or other hazardous materials such as asbestos, arsenic, barium, beryllium, lead, pesticides, or other health-endangering materials.
  8. Always place the cleaner on a horizontal flat surface to prevent it from falling or moving unintentionally.
  9. Never use the cleaner outdoors in the rain.
  10. For Finland, this machine is not to be used outdoors at low temperatures.
  11. Do not use close-to-heat sources (stoves, etc.).
  12. If the exhaust air is returned to the room, it is necessary to provide for an adequate air change rate in the room. Reference to National regulations is necessary.
  13. Do not block suction inlet/outlet/cooling vents. These vents permit the cooling of the motor. The blockage should be carefully avoided otherwise the motor will burn out due to a lack of ventilation.
  14. Keep proper footing and balance at all times.
  15. Do not fold, tug or step on the hose.
  16. Stop the cleaner immediately if you notice poor performance or anything abnormal during operation.
  17. REMOVE THE BATTERY(IES). When not in use, before servicing, and when changing accessories.
  18. Clean and service the cleaner immediately after each use to keep it in tiptop operating condition.
  19. MAINTAIN THE CLEANER WITH CARE. Keep the cleaner clean for better and safer performance. Follow instructions for changing accessories. Keep handles dry, clean, and free from oil and grease.
  20. CHECK DAMAGED PARTS. Before further use of the cleaner, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service center unless otherwise indicated elsewhere in this instruction manual. Have defective switches been replaced by the authorized service center? Don’t use the cleaner if the switch does not turn it on and off.
  21. For user servicing, the machine shall be dismantled, cleaned, and serviced, as far as is reasonably practicable, without causing risk to the maintenance staff and others.
  22. The machine should be technically inspected by the manufacturer, or an instructed person, at least annually, consisting of, for example, an inspection of filters for damage, airtightness of the machine, and proper function of the control mechanism.
  23. When carrying out service or repair operations, all contaminated items which cannot be satisfactorily cleaned are to be disposed of; such items shall be disposed of in impervious bags in accordance with any current regulation for the disposal of such waste.
  24. REPLACEMENT PARTS. When servicing, use only identical replacement parts.
  25. When not in use, always store the cleaner indoors.
  26. Be kind to your cleaner. Rough handling can cause breakage of even the most sturdily built cleaner.
  27. Do not attempt to clean the exterior or interior with benzine, thinner, or cleaning chemicals. Cracks and discoloration may be caused.
  28. Do not use cleaner in an enclosed space where flammable, explosive, or toxic vapors are given off by oil-base paint, paint thinner, gasoline, some moth-proofing substances, etc., or in areas where flammable dust is present.
  29. Do not operate the cleaner or any tool while under the influence of drugs or alcohol.
  30. As a basic rule of safety, use safety goggles or safety glasses with side shields.
  31. Use a dust mask in dusty work conditions.
  32. This machine is not intended for use by persons including children with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
  33. Children should be supervised to ensure that they do not play with the cleaner.
  34. Never handle battery(ies) and cleaner with wet hands.
  35. Use extreme caution when cleaning on stairs.
  36. Do not use the cleaner as a stool or workbench. The machine may fall down and may result in personal injury.

Battery tool use and care

  1. Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack.
  2. Use power tools only with specifically designated battery packs. Use of any other battery packs may create a risk of injury and fire.
  3. When the battery pack is not in use, keep it away from other metal objects, like paper clips, coins, keys, nails, screws, or other small metal objects, that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire.
  4. Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
  5. Do not use a battery pack or tool that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion, or risk of injury.
  6. Do not expose a battery pack or tool to fire or excessive temperature. Exposure to fire or temperatures above 130 °C may cause an explosion.
  7. Follow all charging instructions and do not charge the battery pack or tool outside the temperature range specified in the instructions. Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of fire.

SAVE THESE INSTRUCTIONS.

WARNING: DO NOT let comfort or familiarity with the product (gained from repeated use) replace strict adherence to safety rules for the subject product.  MISUSE or failure to follow the safety rules stated in this instruction manual may cause serious personal injury.

Important safety instructions for battery cartridge

  1. Before using battery cartridge, read all instructions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery
  2. Do not disassemble or tamper with the battery cartridge. It may result in a fire, excessive heat, or explosion.
  3. If the operating time has become excessively shorter, stop operating immediately. It may result in a risk of overheating, possible burns, and even an explosion.
  4. If electrolyte gets into your eyes, rinse them out with clear water and seek medical attention right away. It may result in loss of your eyesight.
  5. Do not short the battery cartridge:
    (1) Do not touch the terminals with any conductive material.
    (2) Avoid storing battery cartridges in a container with other metal objects such as nails, coins, etc.
    (3) Do not expose the battery cartridge to water or rain.
    A battery short can cause a large current flow, overheating, possible burns, and even a breakdown.
  6. Do not store and use the tool and battery cartridge in locations where the temperature may reach or exceed 50 °C (122 °F).
  7. Do not incinerate the battery cartridge even if it is severely damaged or is completely worn out. The battery cartridge can explode in a fire.
  8. Do not nail, cut, crush, throw, drop the battery cartridge, or hit against a hard object to the battery cartridge. Such conduct may result in a fire, excessive heat, or explosion.
  9. Do not use a damaged battery.
  10. The contained lithium-ion batteries are subject to the Dangerous Goods Legislation requirements. For commercial transports e.g. by third parties, forwarding agents, special requirements on packaging and labeling must be observed. For the preparation of the item being shipped, consulting an expert for hazardous material is required. Please also observe possibly more detailed national regulations. Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging.
  11. When disposing of the battery cartridge, remove it from the tool and dispose of it in a safe place. Follow your local regulations relating to the disposal of batteries.
  12. Use the batteries only with the products specified by Makita. Installing the batteries to non-compliant products may result in a fire, excessive heat, explosion, or leak of electrolyte.
  13. If the tool is not used for a long period of time, the battery must be removed from the tool.
  14. During and after use, the battery cartridge may take on heat which can cause burns or low-temperature burns. Pay attention to the handling of hot battery cartridges.
  15. Do not touch the terminal of the tool immediately after use as it may get hot enough to cause burns.
  16. Do not allow chips, dust, or soil stuck into the terminals, holes, and grooves of the battery cartridge. It may result in poor performance or breakdown of the tool or battery cartridge.
  17. Unless the tool supports the use of near high-voltage electrical power lines, do not use the battery cartridge near high-voltage electrical power lines. It may result in a malfunction or breakdown of the tool or battery cartridge. 18. Keep the battery away from children.

SAVE THESE INSTRUCTIONS.

CAUTION: Only use genuine Makita batteries.
Use of non-genuine Makita batteries, or batteries that have been altered, may result in the battery bursting causing fires, personal injury, and damage. It will also, void the Makita warranty for the Makita tool and charger.

Tips for maintaining maximum battery life

  1. Charge the battery cartridge before completely discharged. Always stop tool operation and charge the battery cartridge when you notice less tool power.
  2. Never recharge a fully charged battery cartridge. Overcharging shortens the battery service life.
  3. Charge the battery cartridge with room temperature at 10 °C – 40 °C (50 °F -104 °F). Let a hot battery cartridge cool down before charging it.
  4. When not using the battery cartridge, remove it from the tool or the charger.
  5. Charge the battery cartridge if you do not use it for a long period (more than six months).

Important safety instructions for the wireless unit

  1. Do not disassemble or tamper with the cleaner.
    The wireless unit in the cleaner cannot be removed.
  2. Do not operate the wireless activation function in places where medical instruments, heart pacemakers, or automated devices, such as automatic doors and fire alarms, are nearby.
  3. Do not use the cleaner in places where the temperature exceeds 50°C (122°F).
  4. The wireless unit is an accurate instrument. Be careful not to drop or strike the cleaner.
  5. Do not leave the cleaner in a place where static electricity or electrical noise could be generated.

FUNCTIONAL DESCRIPTION

CAUTION: Always be sure that the tool is switched off and the battery cartridge is removed before adjusting or checking the function on the tool.

Installing or removing battery cartridge

CAUTION: Always switch off the tool before installing or removing the battery cartridge.
CAUTION: Hold the tool and the battery cartridge firmly when installing or removing the battery cartridge. Failure to hold the tool and the battery cartridge firmly may cause them to slip off your hands and result in damage to the tool and battery cartridge and a personal injury.
CAUTION: Be careful not to pinch your fingers when opening or closing the battery cover. Failure to do so may cause personal injury.

To install the battery cartridge, release the lock first, and open the battery cover. And then, insert the battery cartridge.

► 1. Lock 2. Battery cover

Align the tongue on the battery cartridge with the groove in the housing and slip it into place. Insert it all the way until it locks in place with a little click.  Then lock the battery cover.

► 1. Battery cartridge

To remove the battery cartridge, slide it from the tool while sliding the button on the front of the cartridge.

CAUTION: Always install the battery cartridge fully until the red indicator cannot be seen. If not, it may accidentally fall out of the tool, causing injury to you or someone around you.
CAUTION: Do not install the battery cartridge forcibly. If the cartridge does not slide in easily, it is not being inserted correctly.
NOTE: The cleaner does not work with only one battery cartridge.

Indicating the remaining battery capacity

Only for battery cartridges with the indicator

► 1. Indicator lamps 2. Check button

Press the check button on the battery cartridge to indicate the remaining battery capacity. The indicator lamps light up for a few seconds.

Indicator lamps Remaining
capacity

Lighted

Off

Blinking

75% to 100%
50% to 75%
25% to 50%
0% to 25°/0
Charge the battery.
The battery may have
malfunctioned.

NOTE: Depending on the conditions of use and the ambient temperature, the indication may differ slightly from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when the battery protection system works.

Indicating the remaining battery capacity

► 1. Battery indicator 2. Check button 3. Stand-by switch

Press the check button to indicate the remaining battery capacities. The battery indicators correspond to each battery.

NOTE: During the cleaner turned on with the standby switch set to “AUTO”, the battery indicator does not work.

Tool/battery protection system

The tool is equipped with a tool/battery protection system. This system automatically cuts off power to the motor to extend tool and battery life. The tool will automatically stop during operation if the tool or battery is placed under one of the following conditions:

Overload protection

When the tool is operated in a manner that causes it to draw an abnormally high current, the tool automatically stops without any indication. In this situation, turn the tool off and stop the application that caused the tool to become overloaded. Then turn the tool on to restart.

Overheat protection

When the tool is overheated, the tool stops automatically, and the battery indicator blinks for about 60 seconds. In this situation, let the tool cool down before turning the tool on again.

Overdischarge protection

When the battery capacity becomes low, the tool stops automatically. If the product does not operate even when the switches are operated, remove the batteries from the tool and charge the batteries.

Switch action

► 1. Stand-by switch 2. Power button 3. Suction force adjusting knob

To start the cleaner:

  1.  Set the standby switch to the “I” side. The cleaner gets into the standby state.
  2. Press the power button.
    To make the cleaner get into standby mode, press the power button again.
    To turn off the cleaner, set the standby switch to the “O” side.

The suction power can be adjusted according to your work need.
Suction power can be increased by turning the suction force adjusting knob from the symbol to the symbol.

NOTICE: Always set the stand-by switch to the “O” side when not using the cleaner for a long time. The cleaner consumes power during the standby state.

Locking or unlocking the caster

► 1. Caster 2. Stopper lever 3. FREE position 4. LOCK position

Locking the caster is convenient when storing the cleaner, stopping the work on the way, and keeping the cleaner still.
To operate the stopper, move it by hand.
To lock the caster with a stopper, lower the stopper lever and the caster no longer will rotate. To release the caster from the locked position, raise the stopper lever.

NOTE: When moving the cleaner, make sure that the caster is unlocked. Moving the cleaner with the caster in the locked position may cause damage to the caster.

Carriage handle

When carrying the cleaner, carry it by holding the handle on the head. The handle is retractable at the head when not in use.

WIRELESS ACTIVATION FUNCTION

What you can do with the wireless activation function

The wireless activation function enables clean and comfortable operation. By connecting a supported tool to the cleaner, you can run the cleaner automatically along with the switch operation of the tool.

NOTICE: Be sure to refer to the instruction manual of the tool when using the cleaner with a wire-less activation function.
NOTICE: Do not disassemble or tamper with the wireless unit.
NOTICE: Always close the lid of the wireless unit in the tool when operating or storage. NOTICE: Do not remove the wireless unit from the tool while the power is being supplied to the tool. Doing so may cause a malfunction of the wireless unit.
NOTICE: Do not press the wireless activation button too hard and/or press the button with an object with a sharp edge.

NOTE: Wireless activation needs Makita tools equipped with the wireless unit.
NOTE: Prior to the initial use of the wireless activation function with each tool, tool registration is required. Once the registration is finished with the tool, the re-registration is not required unless it is canceled.
NOTE: Before registration, be sure that the wireless unit is properly inserted into the tool.
NOTE: One cleaner can register up to 10 tools. If more than 10 tools are registered to the cleaner, the tool registered earliest will be canceled automatically.
NOTE: The position of the wireless activation button varies depending on the tool.
NOTE: The cleaner also starts by pressing the power button when the standby switch is set to “AUTO”. However, the power button will not actuate when the wireless activation function is used.

Tool registration for the cleaner

NOTE: A Makita tool supporting the wireless activation function is required for the tool registration.
NOTE: Finish installing the wireless unit to the tool before starting the tool registration.
NOTE: During the tool registration, do not pull the switch trigger on the tool or turn on the power switch on the cleaner.
NOTE: Refer to the instruction manual of the tool, too.

If you wish to activate the cleaner along with the switch operation of the tool, finish the tool registration beforehand.

  1. Install the batteries to the cleaner and the tool.
  2. Set the standby switch on the cleaner to “AUTO”.
    ► 1. Stand-by switch
  3. Press the wireless activation button on the cleaner for 3 seconds until the wireless activation lamp blinks in green. And then press the wireless activation button on the tool in the same way.
    ► 1. Wireless activation button 2. Wireless activation lamp
If the cleaner and the tool are linked successfully, the wireless activation lamps will light up in green for 2 seconds and start blinking in blue.

NOTE: The wireless activation lamps finish blinking in green after 20 seconds elapsed. Press the wireless activation button on the tool while the wireless activation lamp on the cleaner is blinking. If the wireless activation lamp does not blink in green, push the wireless activation button briefly and hold it down
again.
NOTE: When performing two or more tool registration for the cleaner, finish the tool registration one by one.

Starting the wireless activation function

NOTE: Finish the tool registration for the cleaner for wireless activation.
NOTE: Always place the cleaner so that you can see the status of the wireless activation lamp.
NOTE: Refer to the instruction manual of the tool, too.

After registering a tool to the cleaner, the cleaner will automatically run along with the switch operation of the tool.

  1. Install the wireless unit to the tool.
  2. Connect the hose of the cleaner with the tool.
  3. Set the standby switch on the cleaner to “AUTO”.
  4. Push the wireless activation button on the tool briefly. The wireless activation lamp will blink in blue.
    ► 1. Wireless activation button 2. Wireless activation lamp
  5. Pull the switch trigger of the tool. Check if the cleaner runs while the switch trigger on the tool is being pulled.

To stop the wireless activation, push the wireless activation button on the tool, or set the standby switch on the cleaner to “I” or “O”.

NOTE: The wireless activation lamp on the tool will stop blinking in blue when there is no operation for 2 hours. In this case, set the standby switch on the cleaner to “AUTO” and press the wireless activation button on the tool again.
NOTE: The cleaner starts/stops with a delay. There is a time lag when the cleaner detects a switch operation of the tool.
NOTE: The transmission distance of the wireless unit may vary depending on the location and surrounding circumstances.
NOTE: When two or more tools are registered to one cleaner, the cleaner may start running even if you don’t pull the switch trigger because another user is using the wireless activation function.

Canceling tool registration for the cleaner

Perform the following procedure when canceling the tool registration for the cleaner.

  1. Install the batteries to the cleaner and the tool.
  2. Set the standby switch on the cleaner to “AUTO”.
    ► 1. Stand-by switch
  3. Press the wireless activation button on the cleaner for 6 seconds. The wireless activation lamp blinks in green and then becomes red. After that, press the wireless activation button on the tool in the same way.
    ► 1. Wireless activation button 2. Wireless activation lamp

If the cancellation is performed successfully, the wireless activation lamps will light up in red for 2 seconds and start blinking in blue.

NOTE: The wireless activation lamps finish blinking in red after 20 seconds elapsed. Press the wireless activation button on the tool while the wireless activation lamp on the cleaner is blinking. If the wireless activation lamp does not blink in red, push the wireless activation button briefly and  hold it down
again.

Erasing all tool registrations

You can erase all tool registrations from the cleaner as follows.
► 1. Stand-by switch 2. Wireless activation button 3. Wireless activation lamp

  1. Install the batteries to the cleaner.
  2. Set the standby switch to “AUTO”.
  3. Hold down the wireless activation button for about 6 seconds until the wireless activation lamp blinks in red (about twice per one second).
  4. When the wireless activation lamp starts blinking in red, release your finger from the wireless activation button. Thereafter, hold down the wireless activation button again for about 6 seconds.
  5. When the wireless activation lamp starts blinking fast (about 5 times per second) in red, release your finger from the wireless activation button.  When the wireless activation lamp lights up in red and later lights off, all tool registrations are erased.

NOTE: If the wireless activation lamp does not blink in red, press the wireless activation button briefly and try again.

Description of the wireless activation lamp status

► 1. Wireless activation button 2. Wireless activation lamp

The wireless activation lamp shows the status of the wireless activation function. Refer to the below table for the meaning of the lamp status.

Status Wireless activation amp Description
Color On

Blinking

Duration
(approximate)
Standby Blue Cleaner: con-
tinuing
Tool: 2 hours
Waiting for the tool registration or the wireless activation function is available.
The lamp on the cleaner blinks when the standby switch is set in AUTO. The lamp on the tool blinks when the wireless activation button is pushed. The lamp on the tool will automatically turn off when no operation is performed for 2 hours.
When the tool is
running.
The wireless activation of the cleaner is available and the tool is running.
Tool
registration
Green 20 seconds Ready for the tool registration. Searching the tool to be registered.
2 seconds The tool registration has been finished. The wireless activation lamp will start blinking in blue.
Cancelling/
erasing
tool
registration
Red

(slow: 2 times/sec.)

20 seconds Ready for the cancellation of the tool registration. Searching for the tool to be canceled.

(fast: 5 times/sec.)

When the
the wireless activation button is pressed down.
Ready to erase all tool registrations.
2 seconds The tool registration has been canceled/erased. The wireless activation lamp will start blinking in blue.
Others Red 3 seconds The power is supplied to the wireless unit and the wireless activation function is starts up.
Off The standby switch is not set to “AUTO”.

Troubleshooting for the wireless activation function

Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual, do not attempt to dismantle the tool.  Instead, ask Makita Authorized Service Centers, always using Makita replacement parts for repairs.

State of abnormality Probable cause (malfunction) Remedy
The wireless activation lamp does not tight/blink. The wireless unit is not installed into the tool. The wireless unit is improperly installed into the tool. Install the wireless unit correctly in the tool.
The terminal of the wireless unit and/or the slot Is duty. Gently wipe off dust and dirt on the terminal of the wireless unit and clean the slot of the tool.
The wireless activation button on the tool has not been pushed. Push the wireless activation button on the tool briefly.
The standby switch on the cleaner is not set to “AUTO’. Set the standby switch on the cleaner to ‘AUTO’.
No power supply Supply the power to the tool and the cleaner.
Cannot finish tool registration/can-
ceiling tool registration successfully.
The wireless unit is not installed into the tool. The wireless unit Is improperly installed into the tool. Install the wireless unit correctly in the tool.
The terminal of the wireless unit and/or the slot Is dirty. Gently wipe off dust and dirt on the terminal of the wireless unit and clean the slot of the tool.
The standby switch on the cleaner is not set to ‘AUTO’. Set the standby switch on the cleaner to “AUTO’.
No power supply Supply the power to the tool and the cleaner.
Incorrect operation Push the wireless activation button briefly and perform the tool registration/cancellation procedures again.
The tool and cleaner is away from each other (out of the transmission range). Get the tool and the cleaner closer to each other. The maximum transmission distance is approximately 10 m however it may vary according to the circumstances.
Before finishing the tool registration/ cancellation:
– the switch trigger on the tool is pulled off – the power button on the cleaner is turned on.
Push the wireless activation button briefly and perform the tool registration/cancellation procedures again.
The tool registration procedures for the tool or the cleaner have not been finished. Perform the tool registration procedures for the tool and the cleaner at the same time.
Radio disturbance by other appliances generates high-Intensity radio waves. Keep the tool and the cleaner away from the appliances such as WI-Fi devices and microwave ovens.
The cleaner does not run along with the switch operation of the tool. The wireless unit is not installed into the tool. The wireless unit Is improperly installed into the tool. Install the wireless unit correctly in the tool.
The terminal of the wireless unit and/or the slot Is dirty. Gently wipe off dust and dirt on the terminal of the wireless unit and clean the slot of the tool.
The wireless activation button on the toot has not been pushed. Push the wireless activation button briefly and make sure that the wireless activation lamp Is blinking in blue.
The standby switch on the cleaner is not set to ‘AUTO’. Set the standby switch on the cleaner to ‘AUTO*.
More than 10 tools are registered to the cleaner. Perform the tool registration again.
If more than 10 tools are registered to the cleaner. the tool registered earliest will be canceled automatically.
The cleaner erased all tool registrations. Perform the tool registration again.
No power supply Supply the power to the tool and the cleaner.
The tool and cleaner is away from each other (out of the transmission range). Get the tool and the cleaner closer to each other. The maximum transmission distance is approximately 10 m however it may vary according to the circumstances.
Radio disturbance by other appliances generates high-Intensity radio waves. Keep the tool and the cleaner away from the appliances such as Wi-Fi devices and microwave ovens.
The cleaner runs while the tool’s switch trigger is not pulled. Other users are using the wireless activation of the cleaner with their tools. Turn off the wireless activation button of the other tools or cancel the tool registration of the other tools.
State of abnormality Probable cause (malfunction) Remedy
Cannot erase all tool registrations in the cleaner. Pressing the wireless button on the tool. Press the wireless button on the cleaner for erasing all tool registrations.
The standby switch on the cleaner is not set to ‘AUTO’. Set the standby switch on the cleaner to-AUTO’.
The wireless activation button is not held down correctly. Hold down the wireless activation button for more than 6 seconds and then release it when the wireless activation lamp blinks in red. Hold down the wireless activation button for more than 6 seconds again until the wireless activation button rapidly blinks in red and then releases the button.

PARTS DESCRIPTION

► 1. Tank cover 2. Powder filter (HEPA) 3. Damper 4. Prefilter 5. Tank

ASSEMBLY

CAUTION: Always be sure that the tool is switched off and the battery cartridge is removed before carrying out any work on the tool.
CAUTION: Always wear a dust mask during assembly or maintenance.

Installing the powder filter (HEPA) and prefilter (for dry dust)

CAUTION: Never pick up water or other liquids or wet dust when using the powder filter. Picking up such things may cause powder filter breakage.
To use powder filter:

  1. Place the prefilter in the tank while aligning the mounting position markings.
  2. Mount the damper on the powder filter and then place them in the prefilter while aligning the mounting position markings.
  3. Mount the tank cover and lock it.

► 1. Tank cover 2. Powder filter (HEPA) 3. Damper 4. Prefilter 5. Tank 6. Mounting position marking
NOTICE: Before using the powder filter, make sure that prefilter and damper are used together. It is not allowed to install powder filters alone.

Installing the paper pack

Optional accessory
WARNING: When using the paper pack, also use the prefilter together that is preinstalled on the tool. Failure to use the prefilter together may cause unusual noise and heat, resulting in a fire.
CAUTION: Before using the paper pack, make sure that powder filter, damper, and prefilter are always used together.

  1. Remove the rubber holder.

  1. Rubber holder
  2. Extend the paper pack.
  3. Align the paper pack opening with the dust suction opening of the cleaner.
  4. Insert the cardboard of the paper pack onto the holder so that it is positioned at the end beyond the detent protrusion.

► 1. Paper pack 2. Holder

Installing the polyethylene bag

The cleaner can also be used without polyethylene bags. However, using a polyethylene bag is easier to empty the tank without letting your hands dirty.
Spread the polyethylene bag in the tank. Insert it between the holder plate and the tank, and pull it to the hose inlet.

► 1. Holder plate 2. Polyethylene bag
Spread the bag around the top of the tank so that the prefilter edge can catch and hold the bag securely.

► 1. Prefilter
NOTE: A polyethylene bag available on the market can be used. 0.04 mm or thicker one is recommended.
NOTE: Too much dust will tear the bag easily, so do not collect the dust more than half of the bag capacity.

Emptying the polyethylene bag

WARNING: Always make sure that the cleaner is switched off and the battery cartridge is removed before emptying the polyethylene bag.
Failure to do so may cause an electric shock and serious personal injury.
CAUTION: Do not apply a great impact on the tank. Applying a great impact may cause deformation and damage to the parts.
CAUTION: Empty the tank at least once a day although this depends on picked-up dust volume in the tank.
Or, the suction force will weaken and the motor may be broken.
CAUTION: Do not grab the hook when emptying the tank. Grabbing the hook may cause the hook to break.
Unhook and lift up the tank cover.
Shake off the dust from the prefilter and then take the polyethylene bag out of the tank.

NOTE: Take the polyethylene bag carefully out of the tank so that the polyethylene bag cannot be caught and torn by the protrusion inside the tank when emptying it.
NOTE: Empty the polyethylene bag before it becomes full. Too much dust in the tank may cause the polyethylene bag to be torn.

Installing the toolbox

  1. Release the lock of the battery cover, and open the battery cover.
  2. Set the rails on the toolbox along the grooves on the housing.
  3. Close the battery cover and apply the lock.

The toolbox is convenient for carrying batteries, pipes, or cuffs.

Connecting the hose

NOTICE: Never force the hose for bending or stamp it. Never move the cleaner by a hose.
Forcing, stamping, and pulling the hose may cause breakage or deformation of the hose.
NOTICE: When picking up large wastes such as planer carvings, concrete dust, or similar other than small wastes, use the 38 mm inner diameter hose (optional accessory). Using the 28 mm inner diameter hose (optional accessory) may cause hose stuffing and damage.
Insert the hose onto the mounting port of the tank and turn it clockwise until it locks.

MAINTENANCE

CAUTION: Always be sure that the tool is switched off and the battery cartridge is removed before attempting to perform inspection or maintenance.
NOTICE: Never use gasoline, benzene, thinner, alcohol, or the like. Discoloration, deformation, or cracks may result.

Storage of accessories

The pipes can be placed into the pipe holder when notusing the cleaner for a short time.

The hose can be stored around the tool by connecting each end.

Cleaning of powder filter (HEPA) and prefilter

Clogged powder filter, prefilter, and damper cause poor suction performance. Clean out the filters and dampers from time to time.
To remove dust or particles adhering to the filters, shake the frame bottom quickly several times.

Occasionally wash the powder filter in water, rinse and dry thoroughly in the shade before use. Never wash filters in a washing machine.
NOTE: Do not rub or scratch the powder filter, the prefilter, or the damper with hard objects such as a brush and a paddle.
NOTE: The filters wear out in course of time. It is recommended to have some spares for them.
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers, always using Makita replacement parts.

OPTIONAL ACCESSORIES

CAUTION: These accessories or attachments are recommended for use with your Makita tool specified in this manual. The use of any other accessories or attachments might present a risk of injury to persons. Only use accessory or attachment for its stated purpose. If you need any assistance for more details regarding these accessories, ask your local Makita Service Center.

  • Hose
  • Front cuff (22, 24, 38)
  • Straight pipe
  • Corner nozzle
  • Round brush
  • Powder filter, HEPA (for dry dust)
  • Damper
  • Prefilter
  • Nozzle assembly
  • Bent pipe
  • Polyethylene bag
  • Paper pack
  • Holder set
  • Makita genuine battery and charger

NOTE: Some items in the list may be included in the tool package as standard accessories. They may differ from country to country.

Makita Europe N.V.
Jan-Baptist Vinkstraat 2,
3070 Kortenberg, Belgium
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi 446-8502 Japan
www.makita.com
885608A225
20201224