Panasonic F-YAU25H 25L 2-In-1 Air Purifying Dehumidifier Instruction Manual

Operating Instructions
Air Purifying Dehumidifier
Model No. F-YAU25H

This product is for indoor use only
Correct use will help you save electricity

Warranty card included Separately

Thank you for purchasing this Panasonic product.

  • Please read these operating instructions carefully, in order to use the product correctly and in a safe manner.
  • Please read the “Safety precautions” section (page2 ~4)caerfully before use.
  • Make sure that the correct information is written on the warranty card, including the date of purchase and the name of the distributor. Send the warranty card back within ten days of purchase. Keep the warranty documentation ina safe place along with the operating instructions for future reference.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard. Please disconnect the power plug and empty the tank before doing any maintenance work.

Safety precautions

Always pay attention to these precautions

To prevent users and others bodily harm or property losses, we are explaining the precautions must be observed.

  • Ignoring the symbols incorrect operation, can result in harm or level of damage, described in the following two categories.
    WARNING This symbol indicates the “Possibility of death or serious injury’.
    CAUTION This symbol indicates the “Possibility of injury or damage to property”.
  • Meanings of symbols that always observed are as shown below.
    This symbol indicates an action that *requires caution’.
    This symbol indicates a “never do this” action.
    This symbol indicates an “always do this” action.

    WARNING

    • Do not do anything that may damage the power cord or power plug.Do not damage, modify, bend strongly, pull, place heavy objects on top, or binding with nylon yam or wire on power plug. If using damaged power cord may result in electric shock, short circuit, causing fire.
    • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
    • Do not unplug the power plug with wet hands.
      Electric shocks may occur.
    • Avoid the power cord if it is damaged or modified
      Damage from heavy objects placed on top, heating, or pulling could cause fire or electric shock.
    • Do not use overloaded the rated current of the power outlet and wiring equipment.
      Use too many branch lines will exceed the rated current, it may cause a fire by overheating.
    • Do not use a damaged power cord  Using damaged power cord, electric shocks or fire may occur. Please consult with the dealership or service Station.
    • Do not start or stop the unit by plugging or unplugging the power plug.
      It may cause fire or electric shocks by overheating.
    • Insert the power plug completely
      If the power plug is not inserted securely, fire due to overheating may occur.
    • Do not use damaged power plugs or loose wall sockets.
    • Do not use the voltage other than as specified for unit.
      It may cause fire or electric shocks by overheating.
    • Do not insert fingers or other objects into the air inlet or outlet.
      The rotating fan inside the unit could cause injury.
    • Do not unplug roughly.
      Unplug roughly may damage the power cord, cause electric shock, short circuit fire.
    • Do not place the unit near a heater.
      Plastic parts may melt and cause fire.
    • Periodically clean the dust and dirt on the power plug.
      If dust accumulates on the power plug, humidity may cause damage to insulation and may result in fire.
    • Unplug the power plug and wipe it with dry cloth.
      If not using the unit, unplug the power plug.
    • Never try to repair the unit by yourself.
      Fire or electric shock may occur.
    • Please consult the purchasing dealership or service station for repairs.
    • Do not stretch the power cord.
      It may cause short circuit or broken wires (which may cause fire or electric shock.)
    • Switch off and then unplug out the power plug when error occurs (smoke etc.)
      • Incorrect On/Off operations.
      • Switch electric leakage or fuse burned frequently.
      • Power cord or power plug heats up abnormally.
      • Burning smell or abnormal noise during operation.
      • Water leakage from the unit.
    • Other abnormal faulty condition.
      It may cause fire or electric shock by overheating.
    • Please consult the purchasing dealership or service station.
    • Do not pull on the power cord when carrying or storing the unit.
      It may damage the wires inside the cord, and fire or electric shock may occur.

    CAUTION

    • Monitor indoor temperature during prolonged operation.
      During operation, heat from the unit may cause indoor temperature to rise, operating in closed room may cause discomfort.
    • Pay particular attention if infants or the elderly are present.
    • Do not operate in areas where water may be easily splashed onto the unit.
      Fire or electric shock may occur
    • Place the unit on level and sturdy floor.
      If the unit tilts, water will overflow, and wet the property potentially causing fire or electric shock.
    • Do not use unit near flammable gas.
      If flammable gases permeate the surrounding space, it may cause fire.
    • Do not use in confined spaces such as closets.
      If there is insufficient ventilation, overheating and fire may occur.
    • Do not use in places exposed to direct sunlight, wind or rain.
      Resulting heat may cause fire or electric shock.

    Safety precautions

    CAUTION

    • Do not use in place where there are artworks or academic documents.
      Deterioration of stored articles may occur.
    • Do not place any heat or flame-producing instrument in air outlet of the unit.
      Incomplete combustion may cause carbon monoxide poisoning.
    • When moving the Dehumidifier, turn off the unit and empty the water in the water tank.
      Leaking water may damage the household items and property damage even cause accidents. (People may injured and caused fire or electric shock.)
    • Do not place flower vases or other water containers on top of the unit.
      Water may spill into the unit and fire or electric shock may occur.
    • Do not cover the air inlet or air outlet with cloths or towels.
      Air circulation will decrease and overheating or fire may occur.
    • When the unit is to be cleaned, switch off and unplug.
      The high-speed rotation of the fan inside may Cause injury.
    • Do not wash the Dehumidifier directly with water.
      Water leakage may cause electric shock.
    • Do not sit or climb on the unit.
      You may fall over, and injury may occur.
    • If unit will remain unused for a long period, unplug the power plug, for safety.
      Accumulation of dust and foreign objects may lead to heat and fire may occur.
    • Do not clean your product by spraying insecticides to it or wiping it with benzene or thinner.
      Fire, Electric shock, damage to household items caused by water leakage may occur.
    • Do not move or transport the unit by holding the louvers.
      The unit may fall down and injury may occur.
    • After prolonged use, perform periodic inspection.
      Particularly the air filter and drains should be checked routinely to avoid overheating and leakage, resulting in house fires and items wetted.

    Filter installation

    1. Remove the air filter
    2. Take (2 types of) filters out from the plastic bags.
      * The HEPA filter is pre-installed in the unit at the factory, while the deodorant filter is placed with the Operating Instructions.
    3. Installation procedures: attach the deodorant filter first, and then attach the HEPA filter.
    4. Install the air filter

    Parts name

    The water tank may contain water residue at time of purchase. This is from final product testing at the factory and is not due to a defeat.

    Control panel

    LCD idnicator

    Unpowered
    Press any button when the power is on, selected function will be displayed.

    The LCD backlight lights up, and the backlight will automatically go off after 15 seconds.

    The LCD indicator turns orange for 15 seconds then goes off. The water display and indicator keeps on flashing. If the water full alert is ON, the buzzer beeps for 6 seconds together with the orange indicator.

    Note

    Display of humidity
    * It displays “Hi” if the humidity is higher than 85 % and display “Lo” if the humidity is less than 24 %.

    Repair

    • When the [Rep] indicator flashes and error code “11” prompts, check the following:
    • When unit is tipped over.
      1. Unplug the power plug.
      2. Set the unit back upright (wipe away any spilled water).
      3. Let the unit stand for half a day or more without using it. (To dry the unit inside completely in case any water has spilled inside)
      4. Insert the power plug again and restart the unit.
    • Does the unit tilt?
      → Unplug the power plug and then reconnect it.
    • It indicates unit failure when the [Rep] indicator do not flashing (For example)
    • Please unplug the power plug immediately, and consult service station to repair the unit.

    Full

    • When the [] display and the Full Tank indicator flash, it indicates that the tank is full of water. All functions won’t be able to work if the tank remains full.

    Defrost

    • When the [Def] indicator is flashing, the unit is defrosting.
      → Only the Power Off/On button works. Other buttons will be disabled.

    Mildew prevention

    • Power Off mildew prevention:
    • The product may run 3 minutes in fan mode after operation stopped (by manual or timer settings) to dry its internal side for mildew prevention. Press Power Off/On key when in this mode to cancel this function.
    • This function may not get enabled due to compressor operation time.

    Protection

    • To prevent you from forgetting to swtich off the unit, operation will stop automatically if no button is pressed for 24 hours.
    • If room temperature is higher than 32 °C, the air volume will increase automatically in order to protect the unit.
    • The unit should be operated within an indoor temperature range of 7 ~ 40 °C. Operation out of this range may cause some undesired problem.
    • The unit will stop operation when power failure occurs, and return to standby mode after power recovery. To ensure compressor life, do not operate within 3 minutes after switching offthe unit,

    Safety protection

    • In case there is foreign matter, water, or dust entered your product or you press and hold on or more of its keys for 17 seconds the safety protection mode begins. Its original use status retains. No other key, except the “Power Off/On” key, functions in this mode.
    • The safety protection mode may run up to 10 hours and then auto power off (or by pressing “Power Off/On” key).
    • Once” “and “Rep” indicator light up, remove any foreign matter, water, and dirt or your hand from the product to exit this mode.

    Filter cleaning

    • The filter cleaning indicator will light up when the unit has run for over 500 hours, indicating that the filter needs to be cleaned. (See P.19)
      By pressing Purifying+Sound keys for 3 seconds simultaneously, you can reset the timer and the filter cleaning indicator.
    • The filter cleaning indicator can be reset only with the power turned on. If the sound settings’ on, you will hear a beep.

    Comfort

    • The dehumidifier is used for daily life, such as the removal of unplesant humidity and laundry drying. However, if ambient humidity is under 50 %, unit cannot help maintain a comfortable humidity environment.

    Factory default

    • Standby
      Press Humidity and Laundry simultaneously for about 7 seconds to activate. If “00” is displayed in Humidity part, the unit is reset to the factory default.
    • After resetting to the factory default, all operating modes will be restored to their default settings.

    Memory function

    • When you stop and start the unit, it will return to the previous mode.
    • If you disconnect and connect the plug again, the unit will return to the previous mode. (Except timed settings)

    Attention

    • Avoid leaving any operating dehumidifier unattended.
    • Recommend to have a regular inspection on the dehumidifier by a Qualified Person.

    Air detector indicator

    • The unit has to warm up at initial startup, the PM2.5 sensor and the smell detection will not be accurate in the first 3 minutes.
      PM2.5 detection
    • The PM2.5 table is provided in accordance with the PM2.5 index and health messages of the UK Daily Air Quality Index (DAQI).
    • The index and health messages of the UK Daily Air Quality Index (DAQI) are for outdoor activities, while the unit is designed for indoor uses only.

    Fine particulate matters (PM2.5) index and health messages

    Index 1 2 3 4 5 6 7 8 9 10
    Air Pollution Banding Low Low Low Moderate Moderate Moderate High High High Very High
    PM2.5
    Concentration (pgfm3)
    0-11 12-23 24-35 36-41 42-47 48-53 54-58 59-64 65-70 ≥71
    Accompanying
    health messages for the general population
    Enjoy your usual outdoor activities. Enjoy your usual outdoor activities. Anyone who experiences eye pain, cough or sore throat should reduce outdoor activities. Anyone who experiences eye pain, cough or sore throat should reduce strenuous
    physical activities, particularly outdoors.
    Accompanying
    health messages for at-risk individuals
    Enjoy your usual outdoor activities. Adults and children with lung problems, cardiovascular disease and heart problems, who experience symptoms, should reduce strenuous physical activities, particularly outdoors. 1.Adults and children with lung problems, cardiovascular disease and heart problems should reduce strenuous physical activities, particularly outdoors.
    2.Older people should reduce physical exertion.
    3.People with asthma may find the need to use their reliever inhaler more often.
    1.Adults and children with lung problems, cardiovascular disease and heart problems, as well as older people, should avoid strenuous physical activities, particularly outdoors.
    2.People with asthma may find the need to use their reliever inhaler more often.

    Introduction of particulate matters (PM2.5) index

    1. Particulate matters are the main factors that contribute to poor air quality in autumn and winter, i.e. the prevailing Northeast Monsoon seasons. In particular, fine particles whose diameter is less than 2.5 um can be a health hazard. For more information about the fine particulate matters (PM2.5) air quality index, please refer to the UK Daily Air Quality Index (DAQI).
    2. The index is divided into 10 levels and demonstrated with different colors as per the fine particulate matters (PM2.5) indicator of the UK Daily Air Quality Index (DAQI). For example, at-risk individuals should be careful with their outdoor activities and physical conditions when the PM2.5 concentration is up to 36 ug/m3 (level 4), while the general population should reduce their outdoor activities when the concentration is up to 54 ug/m3 (level 7).
    • The PM2.5 indicator will display 0 ug/m? ~ 600 ug/ms
    • Ifthe air quality detected by the PM2.5 <35 (ug/m3), the indicator lights in green.
    • Ifthe air quality detected by the PM2.5 36-53 (ug/m3), the indicator lights in orange.
    • lf the air quality detected by the PM2.5 54-70 (ug/m3), the indicator lights in red.
    • Ifthe air quality detected by the PM2.5 =71 (ug/m3), the indicator lights in purple.
    • Ifthe air quality detected by the PM2.5 =600 (ug/m3), the indicator just indicate 600.
    • The result may differ with other equipment.
    • The function will be activated automatically when the PM2.5 sensor indicator lights in purple, red and orange.
    Smell detection
    • The smell detection is an automatic inspection function. The smell detection indicator will change the display colors when the detector determines a poor air quality. (The colors of the smell detection indicator will change with the air volume only with the air volume selection is in the Auto mode.)
    • The indicator lights in red when the smell level is high.
    • The indicator lights in orange when the smell level is normal.
    • The indicator lights in green when the smell level is low.
    • The nanoe® function will be activated automatically when the smell detection indicator lights in red and orange.
    • The smell detection range: cigarette smoke, burning incense, cooking smell, pet smells, cosmetics, alcohol and mist sprays.

    Operation mode/Air volume selection

    • To use timed power on in the standby mode (P.15)
    • To use timed power off during operation (P.15)
    • When the Full Tank indicator is flashing (P.16)
    • Operation will stop—Please empty the tank. (Select the operation mode according to P.10 – P.11 before setting)
    • To change air volume
    • The air volume can only be selected in the “Operation mode” and “Humidity settings” modes.
    • The airflow can adjust when in Fan mode. Only Airflow in Auto mode, the air flow will be changed by the volume of PM2.5 and malodor.
    • Your product may enter protection mode with air volume and direction in case room temperature goes above 32 °C. (System  sounds three beeps if you try to press air volume and direction key)

    To set humidity

    • To stop operation
    • The product may run 3 minutes in fan mode after operation stopped to dry its internal side. (Power off mildew prevention P.8)
    • Please unplug the power plug at least 3 minutes after stopping the operation.
    • To use timed power on in the standby mode (P.15)
    • To use timed power off during operation (P.15)

    Laundry mode

    • The product may run 3 minutes in fan mode after operation stopped to dry its internal side. (Power off mildew prevention P.8)
    • Please unplug the power plug at least 3 minutes after stopping the operation.
    • To use timed power on in the standby mode (P.15)
    • To use timed power off during operation (P.15)
    • The ECONAVI Indicator, Auto stop Indicator, Intelligent dryness monitoring system will turn off in this mode.
    • When the Full Tank indicator is flashing (P.16)
    • Operation will stop—Please empty the tank.

    Intelligent dryness monitoring system ()

    • This function is valid for cloth drying.
    • It tells drying status of cloths.

    • After laundry completed, in order to prevent humidity returns to the laundry, please maintain laundry condition.
    • Based on type of laundry, quantity, and method of hanging, and room condition, etc, there may be variation of dry conditions.
    • If user is not satisfied with the dry condition, [Keep Dry] Function may be chosen for further drying.

    indicator

    • To refresh clothes with deodorization and sterilization function will be enabled automatically by system in laundry mode. The LED indicator lights up and cannot be cleared manually. The system beeps two times if you try to press the “Purifying” button.

    bacteriostasis and deodorization

    (Laundry/Mode/Humidity)

    • To clan and deodorize during operation
    • During “Laundry”
      To refresh cloths, with deodorization and sterilization function will be enabled automatically, The LED indicator lights up and cannot be cleared manually. The system beeps if you try to operate the “Purifying” button.If sound set OFF, there is no beep.
    • In “Mode” and “Humidity”
      The function may be switched on/off as desired.
    • When PM2.5 or gas sensor detected that air quality or pollution increased, will turn on and light up.
      (It cannot turn off manually. When operating Purifying, it will beep.)

    About
    The product equipped with , which generates 10 times more hydroxyl (OH) radicals than the .

    Enviroment conditions for generation

    • The is generated from indoor air which may fail to run successfully due to various temperature and humidity conditions.
    • Generation conditions
      Indoor temperature: 5 °C ~ 35 °C with dew temperature above 2 °C.
      Relative humidity: 30 % ~ 85 %
      Little amount of ozone
    • The generation of ion may be accompanied with little amount of ozone. It’s far less than ozone level existing in natural forest and bears virtually no impact on human body.
    • Incase of odor of ozone, disable the “cleaning and deodorization” function.
    •  nanoe™
      nanoe™ nano water ion (nanoe™ ion hereafter) is a charged clean water ion by separating water molecules with high voltage. The nanoe™ ion technology features sterilization, allergens inhibition, fungi elimination and deodorization for skin healthy space.
    • Floating fungi: Results after 4 hours test in 25 cubic meter closed space instead of practical outcome in daily life environment.
    • Adhering fungi: Results after 8 hours test in 23 cubic meter closed space instead of practical outcome in daily life environment.
      Deodorization effects vary with ambient environment (temperature, humidity), operation hours, deodorization, type of fabrics.
    • Standalone test and practical use effectiveness may differ from each other due to conditions and use method.
    • This device is not a medical equipment.
    • About effect of (Anti-bacterial •Anti-allergy )
      Effcet Testing organisation Test method • result
      Inhibit the growth of bacteria floating in the air and attached to furniture such as curtains. Foundation Kitasato Environmental Science Center The test space of 25 m3, inhibit the growth of airbonre bacterial ( one type ) more than 99 % after 4 hours.
      The Japan Food Research Laboratories The test space of 23 m3, inhibit the growth of adhered bacterial ( one type ) more than 99 % after 8 hours.
      Inhibit the growth of mold bacteria attached to furniture such as curtains. The Japan Food Research Laboratories The test space of 23 m3, effectively inhibit the growth of mold bacterial ( one type ) after 8 hours.
      Inhibit the activity of pollen and other allergens. Panasonic Corporation Analysis Center The test space of 23 m3 with ELISA method, 99 % pollen ( one type ) can be inhibited in the space after 24 hours.
      Verified pollen ( 12 type ) by using the electrophoresis method in an approximately 24 m3-sized test chamber.Inhibitory effect was confirmed in 24 hours.

      Note: namoe™ and the nanoe™ mark are trademarks of Panasonic Corporation

      Air Direction selection

      Operations of the air direction selection (Laundry/Mode/Humidity)
      The swing can be set to match the height of the place where you would like the air to reach.

      • To swing louver
      • To fix the louver
        Select Auto to enable louver swing.
        When it reaches the desired location, press the button again.
      • The louver direction indicator lights off and the louver stops swinging and starts blowing in one direction.
        Note
      • Do not move the louver while swinging operation is in progress. (The swing range will change.)
      • In this case, reset the air direction in accordance with the operations of the air direction selection or restart the unit. The angle will become normal.

      Air direction setting example
      Tips for drying effectively

      1. Place the dehumidifier at a place that all clothes can be reached evenly.
      2. Leave space between each item of clothing so that air can circulate freely.
      3. Leave a distance of 40 cm or more between the dehumidifier and the clothes, depending on the amount of clothes.

      * 1: Choose either “Up” or “Down” depending on how high the clothes are hanging and how high the closet is.

      • Based on type of laundry, quantity, and method of hanging, and room condition, etc, there may be variation of dry conditions.

      CAUTION

      • Leather items such as shoes can not be dried with a dehumidifier. (They will become warped or damaged.)

      Timer / Sound / Key lock settings

      To use timed power on in the standby mode

      • When the button is pressed in the standby mode, the LCD display will go on note’. After settings is completed, press the button to finish the “timed power on” settings. If you want to cancel the timed settings, press  the button again.
      • If you do not set any settings in the “timed power on settings” mode, the settings on the display and the LCD backlight will turn off after 15 seconds and return to the previous state.
      • When’ timed power on’is setting, all the keys will be disabled.(Except and key lock.)
      • The timer displays the remaining time once it is set. For  example, if the timer is set to “9 hours” and with 8 hours to go, it displays “8 hours”.

      Note 1: Enter the “timed power on settings” mode. The settings will either be the factory default or the previous settings.

      To use timed power off during operation

      • Press the button when the power is on.
      • The timer displays the remaining time once it is set. For example, if the timer is set to “9 hours” and with 8 hours to go, it displays “8 hours”.
      • The time will keep counting down once the timed power off is set, even if the unit stops due to the full water tank.
      • If you set the timed power off in the laundry mode, the ECONAVI Indicator, Auto stop Indicator and Intelligent dryness monitoring system will not display.

      Sound settings

      Key lock setting

      1. Key lock on
        During standby or operation, please press button for 3 seconds to activate the Key lock.
        When the LCD lights up, all functions are not available.
        (The backlight will light up by pressing any button when locked)
      2. Key lock off
        During standby or operation, please press button for 3 seconds to unlock.
        When the LCD goes off. All functions are available.
        * Key lock will be automatically released when power failure occurs. The Key lock must be re-set.
        * When the tank is full, Key lock cannot be cancelled by pressing the button if the tank is not emptied.

      Handling of louver falling off /Handling of full water tank

      Handling of louver falling off

      Louver fall off

      • Installation of louver
        1. Point and insert holes to the left to thud at left side of your product.
        2. The louver is flat and slightly bent at its center part.
        3. Insert right hand side of it to machine body.

      Handling of full water tank

      • The product stops operation automatically when water in tanks reaches the full level (about 5.2 liter), The LCD indicator turns orange for 10 seconds then goes off. The water display and the Full Tank indicator keeps on flashing. (If the Full Tank Alarm is ON (P.15), the buzzer beeps for 6 seconds together with the orange indicator.)
      • Please empty water tank as described below
      1. Hold the machine body steady with one hand and gently remove water tank out of it with another hand
        • Without hitting each other (cause to failure)
      2. Carry the center part of water tank handle to drainage position.(To avoid water spilled lead to accident, please hold it gently while moving.)
      3. Pull up the water tank cover to open the drainage opening.
      4. Carry the center part of water tank handle and hold the bottom part to drainage position.
      • Water tank installation
        Close the drainage opening, insert water tank into place
      • Close both water tank cover and drainage opening for installation. (or the water tank may fail to install in place and may lead to water leak)
      • Push water tank in place. In case of damaged or poorly installed water tank, the Full Tank indicator may fail to flash and system operation may fail to start. Please remove the water tank and install again.

      How to drain continuously

      • You may connect a hose to this product for continuous drainage if applicable.
        (Call your service center or dealer for continuous drainage installation or removal).
        CAUTION
      • Secure drainage hose firmly.

        Keep drainage hose from bending and elevation difference for good drainage.
        Poor drainage may lead to water leak and wet floor.
      • Keep temperature around the drainage hoses above zero Celsius.

        Or water in drainage hose may get frozen. This may block the hose from drainage and lead to water leak and wet floor.

      Required accessories

      • Commercially available plastic water hose
        Length: 30 cm longer than distance from dehumidifier to drainage opening
        Inner diameter: 15 mm
        Note
        Temperature difference in between water in drainage hose and environment may lead to water condensed on surface of drainage hose. Take insulation measures if necessary.
      1. Remove power plug and water tank
      2. Open up drainage hose holder (turn it 90 degree outward instead of removing it)
      3. Remove water blocker
      4. Install drainage hose
      5. Install water tank
        • Invalid installation may lead to operation failure

      Note: please call your service center or dealer to un-install it as invalid installation may lead to water leak out of water tank.

      Maintenance

      Empty the water tank before doing any maintenance work!

      • Please disconnect the power plug and empty the tank. (see P.16 for how to empty the tank)
      • Cleaning agents such as those shown on the left should not be used.
      • If using a chemically-treated cloth, be sure to read the instructions of the cloth.

      Water tank: once per month

      • Wash the water tank and tank cover with clean water 2 – 3 times.
      • You don’t need to remove the float, just clean it with water.
      • To remove the tank cover1) Turn water tank handle up
        2) Open the water outlet
        3) Pull water tank cover upward
      • Do not strongly pull on the water outlet.
      • Remove sticky dirt with thinned neutral detergent.
      • Inner wall of tank may get black (due to dirt in air which dissolved in water)
      • Float
      • Clean dirt around shaft with water (to prevent float from malfunctions)
      • Do not remove float (invalid installation of it  may lead to operation failure and water leak)
        Insert both axis in hole as illustrated in figure to the left when float falls off.
      • Please disconnect the power plug before servicing.
      • Wipe machine body with a wrung cloth and wipe with a dry cloth again.
        • Do not leave the body widthwise (this may lead to water leak)
        • Remove sticky dirt with thinned neutral detergent. Place it in the shade and dry it completely.

      • You can reset the timer and the filter cleaning indicator after cleaning or filter replacement by pressing buttons for 3 seconds simultaneously while the unit is operating.

      Recommended Frequency of Filter Replacement

      Model No. Recommended replacement frequency Requirements
      HEPA filter Approx. once/3 years When 5 cigarettes are smoked daily (the indication for exchange of filter) (Japan Electrical Manufacturers’ Association standards JEM1467)
      Deodorant filter Approx. once/5 years

      Filter replacement frequency may be shorter than normal, depending on the environment and usage. (Optional parts: P.23)
      (For example, in household where smoking is frequent.) Please replace it when the performance is decreased.

      • Write down the beginning date of service before installing the deodorant filter. Write down the beginning date of service on the sticker and attach it to the unit when replacing the HEPA filter.
      • The used deodorant filter should be disposed as a non-flammable waste.

      Maintenance/About Laundry mode

      For machine not to use for long time

      1. Select function Fan and set it to run for 4 hours and power off automatically afterwards.
      2. Remove power plug, leave it for one day, empty the water tank afterwards (P.16).
      3. Clean body, water tank, and filter.
      4. Cover body with plastic bag.
      5. Store dehumidifier in place of low humidity, good ventilation, and flat surface. (leave it tilted may lead to failure and water leak)

      About Laundry mode

      • About ECONAVI
        Select Normal along with Air to start the laundry operation. The ECONAVI indicator, auto stop indicator, and
        Intelligent dryness monitoring system are on during drying and off afterwards.
        Detect changes in temperature, humidity; run and auto stop operation according to amount of clothes and estimated drying status.
      • Reference operation hours before auto stop (Unit: Hour).
      Model No. F-YAU25H
      Volume of clothes Laundry operation hours
      2 kg – 4 kg roughly 4.0-5.0
      4 kg – 6 kg roughly 5.0-7.0

      Test conditions: temperature at 20 °C; humidity at 80 %, room size at 20 square meters. (results as tested by this company)

      • Actual operation time, power consumption, and dehumidification level may vary with conditions of environment, type, amount, hanging pattern of cloths, room size.
      • To dry clothes with dehumidifier it’s better to do it in small (smaller than 20 square meters) and well-closed space for less energy waste. Operation stops after about 10 hours.
      • Friendly reminder: You can remove HEPA filter when in “Laundry mode” (using ECONAVI) so as to shorten laundry time.
        Please reinstall the HEPA filter after laundry.

      Troubleshooting

      Please check the following first.
      If the problem persists after taken all these steps, disconnect power plug and call your dealer or service center.

      Error Please ensure its contents
      1. Buttons do not operate. • Is the Full tank indicator is flashing (P16), or is Repair indicator flashing? (P.8), Key lock Set? (P.15)
      2. The Full Tank indicator is flashing even though the tank is not full. • Are the tank and float correctly installed inside the unit? (P.16, P.17, P.18)
      • Was the tank banged against the unit during insertion? (P.16) —0 Remove the tank and then reinstall it gently.
      3. Water is leaking. • Has the unit been tilted or knocked over?
      • Was the unit moved while there was still water in the tank? (PA)
      • Has the float come off? (P.18)
      4. The tank does not fill up with water.
      (The unit is not dehumidifying very well.)
      • Is the filter clogged (R19), or is something blocking the air inlet or air outlet? (PA)
      • Are the room temperature and humidity low? (The unit dehumidifies less as the room temperature and humidity become lower.)
      • Is the unit set to operate in “Auto” or “Mild” mode? (P.10)
      • If the temperature is outside the range of 7 °C – 40 °C, dehumidifier operation will stop and become blower operation. (P.8)
      5. No water remains inside the unit. • Is the Fan mode set? (P.10) —. No dehumidifying function in fan mode.
      6. It takes a long time to dry clothes. • Is wet, cold air entering the room? —0 Keep doors and windows closed as much as possible while drying clothes.
      7. Clothes do not dry completely. • Did prior clothes drying cycle complete?
      • Is wet, cold air entering the room?
      → Avoid open doors and windows as much as possible while drying clothes.
      • Is there a heater in use near the unit?
      (If the surrounding temperature is too high, the sensor will be unable to accurately judge the drying time.)
      • Is the air blowing onto the all clothes?
      • Are the clothes hung too closely together or in layers?
      8. The humidity does not go down. • Is wet, cold air entering the room?
      → Avoid opening doors and windows while lanundry.
      • Is there other steam release equipment exists indoor?
      9. Condensation forms all the time, even during dehumidifying. • It may not be possible for dehumidifying to be fully effective if you place the dehumidifier in some places such as near windows, or behind furniture where air circulation is poor.
      10. The Repair indicator flashes with error code [11] displays. • Is machine body tilting?
      1. → Disconnect the plug, lift machine body up straight and wipe waters leaked
      2. leave the machine idle for more than half a day (to dry the unit inside completely in case any water has spilled inside)
      3. connect the plug, run dehumidification again
      • Is machine body tilted too much?
      → Unplug the power plug and then reconnect it.
      11. There is hiss, squeak, or water flow sound heard • This is the sound of the refrigerant flowing within dehumidifier or nanoeTm ion generation. It’s not a failure.
      12.  The smell detection indicator stays on in “red” even if the unit operates continuously • The indicator may light in red under the influence of hot steam from a bathroom or gases generated when using sprays.
      13. The PM2.5 detection indicator stays on in “purple” even if the unit operates continuously • Is the PM2.5 sensor dirty? (P.19)
      14. The air is dirty but the PM2.5 detection indicator still lights in “green” • Please confirm whether it’s in a place that dirt is hard to collect.
      • Is the PM2.5 sensor dirty? (P.19)
      • When the operation mode and air volume change, the PM2.5 sensor may take a longer time to detect.
      15. Air pollutants are hard to remove • Is the HEPA filter dirty? (P.19)
      → If the problem still exist after the maintenance work, replace the filter with a new one.
      16. Low air volume • Is the HEPA filter dirty? (P.19)
      → If the problem still exist after the maintenance work, replace the filter with a new one.
      17. Unpleasant odor makes people feeling ill • Is the HEPA filter dirty? (P.19) Is the deodorant filter ineffective? (P.19)
      → If the problem still exist after the maintenance work, replace the filter with a new one. (The unit is not intended to remove carbon monoxide and hazardous substances generated from cigarettes.)
      • Do you use the dehumidifier in rooms with strong odor?
      If the dehumidifier is used in an environment full of cigarette or barbecue smoke, the filters should be replaced at a shorter interval.
      → If the unit is used in such environments, we recommended that you turn on the air exchange system of the room at the same time.
      18. The air outlet temperature is higher than the indoor temperature • When the compressor starts operating, there is air heat exchange, and thus temperature of the air outlet will increase. It is normal.

      In case of the following, disconnect the power plug and call service center or dealer.

      Error Please ensure its contents
      19. The Repair indicator lights (without flashing) and prompts error code (P.8 Repair) • Machine failure, please note down the error code and call service center or dealer.

      Emergency measures

      In case of the following situations, remove power cord and call your dealer or service center immediately.

      • Poor switch operation.
      • Leak switch or fuse cutout frequently.
      • Power cord and plug over heated.
      • Odor or noise during operation.
      • Water leaks from host.
      • Other error or failure.

      Please observe the rule

      Please have your power cord replaced by equipment manufacturer, service center, or qualified technician for your own safety.

      Optional parts

      Parts name Replacement HEPA filter
      Model No. F-ZPJX32EH
      Parts name Replacement deodorant filter
      Model No. F-ZPKX32EH

      Specifications

      Model No. F-YAU25H
      Power supply 220 V— 50 Hz
      Power plug shape
      Operating condition Temperature 26.7 °C 30 °C
      Relative humidity 60% 80%
      Dehumidification capacity (L/Day) 14.7 25
      Power consumption (W) 245 295
      Water tank capacity (L) The unit automatically stops at around 5.2 litres
      Weight (kg) 17.0
      Dimensions (W X H X D) (mm) 370X614 X298
      • Power consumption by dehumidifier at standby mode: 1.15 W. (with power plug connected)

      Customer’s record

      For model name and production number of this product, please refer to the back side of machine.
      Please record them in the space provided and keep for future reference.

      Model No. SERIAL NO.
      DATE OF PURCHASE DEALER’S NAME
      DEALER’S ADDRESS
      TELEPHONE NUMBER
      • The “Purify PM2.5” logo is the trademark of Panasonic Corporation. This does not mean to remove PM2.5 particle with this machine.
      • This item is made for Hong Kong area only. Therefore, it does not meet China GB,GB/T standards in terms of the safety and feature conditions.

      Panasonic Corporation
      Web Site : http://(www.panasonic.com/
      © Panasonic Ecology Systems Co., Ltd. 2021

      C8041-3770
      2021.10