Important
Safety
Read this user manual carefully before you use the appliance, and save it for future reference.
Danger
- Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and/or a fire hazard.
- Do not clean the appliance with water, any other liquid, or a (flammable) detergent to avoid electric shock and/or a fire hazard.
- Do not spray any flammable materials such as insecticides or fragrance around the appliance.
- The water in the water tank is not suitable for drinking. Do not drink this water and do not use it to feed animals or to water plants. When you empty the water tank, pour the water down the drain.
Warning
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage. Clean the humidifier before next use.
- Check if the voltage indicated on the side of the appliance corresponds to the local power voltage before you connect the appliance.
- If the power cord is damaged, you must have it replaced by Philips, a service center authorized by Philips, or similarly qualified persons in order to avoid a hazard.
- Do not use the appliance if the plug, the power cord, or the appliance itself is damaged.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Cleaning and user maintenance shall not be made by children without supervision.
- Children should be supervised to ensure that they do not play with the appliance.
- Do not block the air inlet and outlet, e.g. by placing items on the air outlet or in front of the air inlet.
- Standard WiFi interface based on 802.11b/g/n at 2.4 GHz with a maximum output power of 31.62 mW EIRP.
Caution
- This appliance is not a substitute for proper ventilation, regular vacuum cleaning, or use of an extractor hood or fan while cooking.
- If the power socket used to power the appliance has poor connections, the plug of the appliance becomes hot. Make sure that you plug the appliance into a properly connected power socket.
- Always place and use the appliance on a dry, stable, level, and horizontal surface.
- Leave at least 20cm free space behind and on both sides of the appliance and leave at least 30cm free space above the appliance.
- Do not place anything on top of the appliance.
- Do not place the appliance directly below an air conditioner to prevent condensation from dripping onto the appliance.
- Make sure all filters are properly installed before you switch on the appliance.
- Only use the original Philips filters specially intended for this appliance. Do not use any other filters.
- Avoid knocking against the appliance (the air inlet and outlet in particular) with hard objects.
- Do not insert your fingers or objects into the air outlet or the air inlet to prevent physical injury or malfunctioning of the appliance.
- Do not use this appliance when you have used indoor smoke-type insect repellents or in places with oily residues, burning incense, or chemical fumes.
- Do not use the appliance near gas appliances, heating devices or fireplaces.
- Always unplug the appliance after use and before filling water, cleaning, or carrying out other maintenance.
- Do not use the appliance in a room with major temperature changes.
- To prevent interference, place the appliance at least 2m away from electrical appliances that use airborne radio waves such as TVs, radios, and radio-controlled clocks.
- When the appliance is not used for a long time, bacteria may grow on the filters.
Check the filters after a long period of disuse. If the filters are very dirty, replace them (see the chapter “Replace the filter and wick”). - The appliance is only intended for household use under normal operating conditions.
- Do not use the appliance in wet surroundings or in surroundings with high ambient temperatures, such as the bathroom, toilet, or kitchen.
- The appliance does not remove carbon monoxide (CO) or radon (Rn). It cannot be used a safety device in case of accidents with combustion processes and hazardous chemicals.
- Only fill the water tank with cold tap water.
Do not use ground water or hot water. - Do not put any substance other than water in the water tank. Do not put fragrance in the water tank.
- If you do not use the humidification function for a long time, clean the water tank and NanoCloud rotary humidification wick tray, and air dry the NanoCloud rotary humidification wick.
- If you need to move the appliance, disconnect the appliance from the power supply first. Then empty or remove the water tank and water tray. Carry the appliance horizontally by the handles on both sides of the appliance.
- Unplug the appliance during filling and cleaning.
Your air purifier
Congratulations on your purchase, and welcome to Philips!
To fully benefit from the support that Philips offers, register your product at
www.philips.com/welcome.
The Philips air purifier brings fresh, humidified air to your house for the health of your family. It offers you advanced evaporation system with NanoCloud technology, using a special humidification filter which adds H2O molecules to the dry air, and produces healthy humid air without formation of water mist. Its humidification filter retains bacteria, calcium and other particles from the water. It delivers only pure humidified air in your home. No more dry air in the winter season or from the air conditioning.
Read this user manual carefully before you use the appliance, and save it for future reference.
Product overview (fig. a)
- A Control panel
- B Water tank
- C Wick support
- D Water tray
- E Unilateral wheels
- F Wick wheel
- G NanoCloud rotary humidification wick (FY2425)
- H Back side cover
- I Pre-filter
- J NanoProtect filter Active Carbon (FY1413)
- K NanoProtect filter Series 2 (FY1410)
- L Air quality sensor
- M Air outlet
Controls overview (fig. b)
Control buttons
Power on/off button
Child lock button
Auto mode button
Fan speed button
Humidity setting button
Light dimming button
2-in-1 mode on/off button
Timer/Reset button
Display panel
Sleep mode
Auto mode
Allergen mode
Purification ONLY mode
2-in-1 mode
Filter replacement alert
Water refill alert
Pre-filter and wick cleaning alert- PM2.5
PM2.5 display
Indoor Allergen Index display
Wi-Fi indicator
Get started
Installing the NanoProtect filter
Before using the appliance, remove all packaging materials of the filter and place it into the appliance described as follows:
Make sure that the side with the tag is pointing towards you.
- Pull the top part of the back panel towards you to release it from the appliance (fig. 3).
- Press the clip down and pull the pre-filter towards you (fig. 4).
- Remove all filters (fig. 5).
- Remove all packaging materials of the NanoProtect filter (fig. 6).
- Place the NanoProtect filter back into the appliance (fig. 7).
- Put the pre-filter back into the appliance, mount the pre-filter onto the bottom of the appliance first, and then push the clips on the top of pre-filter against the appliance (fig. 8).
- To reattach the back cover, mount the panel onto the bottom of the appliance first, and then push the top of the panel against the appliance (fig. 9).
Preparing for humidification
- Pull out the water tank (fig. 10).
- Lift the water tray upwards and pull it out horizontally (fig. 11).
- Remove all packaging material of the NanoCloud rotary humidification wick (fig. 12).
Note
The humidification wick has been assembled on the wick wheel upon purchase. - Place the wick wheel on the wick support (fig. 13).
Note
When placing the wick wheel on the wick support, make sure that the projections on the wick wheel falls into the corresponding grooves. - Place the water tray back into the appliance (fig. 14).
- Turn the top cap of the water tank anticlockwise to unscrew it (fig. 15).
- Fill the water tank with cold tap water (fig. 16).
- Turn the top cap clockwise to tightly lock it onto the water tank (fig. 17).
- Place the water tank back into the appliance (fig. 18).
Wi-Fi connection
Setting up the Wi-Fi connection for the first time
- Download and install the Philips “Clean Home+” app from the App Store or Google Play.
- Put the plug of the air purifier in the power socket and touch
to turn on the air purifier.- The Wi-Fi indicator
blinks orange for the first time.
- The Wi-Fi indicator
- Make sure that your smartphone or tablet is successfully connected to your Wi-Fi network.
- Launch the “Clean Home+” app and click on “Connect a New Device” or press the “+” button on the top of the screen. Follow the onscreen instructions to connect the air purifier to your network.
- After the successful pairing and connection, the Wi-Fi indicator
will light up white. If pairing is not successful, consult the troubleshooting section, or the help section in the “Clean Home+” App for extensive and up-to-date troubleshooting tips.
- This instruction is only valid when the air purifier is being set up for the first time.
If the network has changed or the setup needs to be performed again, consult section “Reset the Wi-Fi connection” on page 5. - If you want to connect more than one air purifier to your smartphone or tablet, you have to do this one by one. Complete the set up of one air purifier before you turn on the other air purifier.
- Make sure that the distance between your smartphone or tablet and the air purifier is less than 10 m without any obstructions.
- This App supports the latest versions of Android and iOS. Please check www.philips.com/cleanhome for the latest update of supported operating systems and devices.
Reset the Wi-Fi connection
- This applies when the default network to which your purifier is connected has changed.
- Reset the Wi-Fi connection when your default network has changed.
- Put the plug of the air purifier in the power socket and touch
to turn on the air purifier. - Touch
and simultaneously for 3 seconds until you hear a beep.- The air purifier goes to pairing mode.
- The Wi-Fi indicator
blinks orange.
- Follow the steps 4-5 in “Setting up the Wi-Fi connection for the first time” section.
Use the appliance
Understanding the air quality light
PM2.5 level | Air quality light color | Air quality level |
≤12 | Blue | Good |
13-35 | Blue-Purple | Fair |
36-55 | Purple-Red | Poor |
>55 | Red | Very poor |
The air quality light automatically goes on when the appliance is switched on, and lights up all colors in sequence. In a short time the air quality sensors select the color that corresponds to the ambient air quality.
PM2.5
AeraSense sensing technology accurately detects and quickly responds to even the slightest particle change in the air. It provides you with reassurance with real-time PM2.5 feedback.
Most of the indoor air pollutants fall under PM2.5 – which refers to airborne particle pollutants smaller than 2.5 micrometers.
Common indoor sources of fine particles are tobacco smoke, cooking, burning candles.
Some airborne bacteria and the smallest mold spores, pet allergen and dust mite allergen particles also fall under PM2.5.
IAI
The professional-grade AeraSense sensor detects the level of indoor air allergen and with numerical feedback from 1 to 12 the potential risk level of indoor air allergens can be displayed. 1 indicates best air quality
Switching on and off
- Put the plug in the power socket.
- The appliance beeps.
- Touch
to switch on the appliance.- The appliance operates under the 2-in-1 mode by default with
displayed on the screen. - When the appliance is warming up, “
” displays on the screen. After measuring the particulate matter only in the air, the appliance shows the PM2.5 level and operates in the auto mode by default. - After measuring the air quality for approximately 30 seconds, the air quality sensor automatically selects the appropriate air quality light color.
- The appliance operates under the 2-in-1 mode by default with
- Touch and hold
for 3 seconds to switch off the appliance.
After the appliance is switched off by the on/off button
Setting the humidity level
- Touch the humidity button
repeatedly to set the desired air humidity to 40%, 50%, 60% or “ ” (fig. 19). Note
When the humidity level “ ” is chosen, the appliance will keep humidifying the room until the ambient humidity level reaches 70%RH. Note- When the target humidity level is reached, the wick wheel will stop rotating. It will start rotating again when the humidity drops below the target level.
- If you want to increase the humidity level quickly, you can select a higher fan speed.
Switching the operation mode
The appliance has two operation modes, the purification ONLY mode and the 2-in-1 mode.
- Touch the mode selection button
to switch to the purification ONLY mode (fig. 20). displays on the screen when the appliance operates in the purification ONLY mode.
- Touch the mode selection button
again to switch to the 2-in-1 mode (fig. 21). displays on the screen when the appliance operates in the 2-in-1 mode.- The current humidity level displays on the screen by default.
The screen will display humidity level for 3 seconds and change to display the highest level of IAI or PM2.5 if one of which is not good.
Using the light dimming function
With the light dimming button, you can switch on or off the air quality light, the display screen and the function indicator if desired.
- Touch the light dimming button
once, the air quality light will be dimmed. - Touch the light dimming button
again, the air quality light and the display panel will be turned off. - Touch the light dimming button
for the third time, all lights will be on again.
Switching the display mode
The appliance has three display modes, PM2.5 display, IAI display and humidity level display.
The appliance operates in PM2.5 display mode by default.
- Touch and hold
for 3 seconds to switch to IAI display (fig. 22).
IAI indicator and the actual IAI level display on the screen. - Touch and hold
for 3 seconds twice to switch to actual humidity level display (fig. 23). - Touch and hold
for 3 seconds to switch to PM2.5 display (fig. 24).
PM2.5 indicator and the actual
PM2.5 level display on the screen.
The screen will display humidity level for 3 seconds and change to display the highest level of IAI or PM2.5 if one of which is not good.
Changing the Auto mode setting
You can choose the Auto mode (
Auto mode
In auto mode, the appliance selects the fan speed in accordance with the ambient air humidity and air quality.
- Touch the fan speed button
to select Auto mode (fig. 25).- Auto (A) and
display on the screen. - The appliance operates in Auto mode by default.
- Auto (A) and
Allergen mode
The extra-sensitive allergen mode is designed to react to even a small change in allergen levels in the surrounding air.
- Touch the Auto mode button
to select the Allergen mode (fig. 26).- Auto (A) and
display on the screen.
- Auto (A) and
Sleep (SL)
In Sleep mode, the air purifier operates quietly on a very low speed.
- Touch the Auto mode button
select the Sleep mode (SL) (fig. 27).- Sleep (SL) and
display on the screen.
- Sleep (SL) and
- All lights will go off except if no buttons are touched after one minute.
- You can turn on the lights manually by touching any buttons.
Changing the fan speed
There are several fan speeds available.
Manual
- Touch the fan speed button
repeatedly to select the desired fan speed (1, 2 or 3) (fig. 28).
Turbo (t)
In Turbo mode, the air purifier operates on the highest speed.
- Touch the fan speed button to select the Turbo mode (
) (fig. 29).
Setting the timer
With the timer, you can let the appliance operate for a set number of hours. When the set time has elapsed, the appliance will automatically switch off.
- Touch the Timer/Reset button
repeatedly to choose the number of hours you want the appliance to operate (fig. 30).- The timer is available from 1 to 12 hours.
- To deactivate the timer function, touch the Timer/Reset button
repeatedly until
“—” displays on the screen.
Setting the child lock
- Touch and hold the child lock button
for 3 seconds to activate child lock (fig. 31).- L displays on the screen for 3 seconds.
- When the child lock is on, all the other buttons are not responsive.
- Touch and hold the child lock button
for 3 seconds again to deactivate child lock (fig. 32).- UL displays on the screen for 3 seconds.
Water level
The water level in the water tank is visible through the water level window on the water tank.
When there is not enough water in the water tank, the water refill light
When there is no water in the water tank, the wick wheel will stop rotating. When the water tank is refilled with water, the wick wheel will start rotating again.
Cleaning
- Always unplug the appliance before cleaning.
- Never immerse the appliance in water or any other liquid.
- Never use abrasive, aggressive, or flammable cleaning agents such as bleach or alcohol to clean any part of the appliance.
- Only the pre-filter and NanoCloud rotary humidification wick are washable. The NanoProtect filter is not washable nor vacuum cleanable.
Cleaning schedule
Frequency | Cleaning method |
When necessary | Wipe the surface of the appliance with a soft dry cloth. |
Every week |
Rinse the water tank, the water tray and the NanoCloud rotary humidification wick. |
When the cleaning icon |
Clean the pre-filter. |
Descale the NanoCloud rotary humidification wick with the water and white vinegar (5% acetic acid) or water and citric acid. |
Cleaning the body of the appliance
Regularly clean the inside and outside of the appliance to prevent dust from collecting.
- Wipe away dust with a soft dry cloth from the body of the appliance.
- Clean the air outlet with a soft dry cloth.
Cleaning the air quality sensor
Clean the air quality sensor every 2 months for optimal functioning of the purifier. Clean them more frequently if you use the purifier in a dusty environment.
When the humidity level in the room is very high, it is possible that condensation develops on the air quality sensor. As a result, the air quality light may indicate that the air quality is bad even though it is good. In this case you have to clean the air quality sensor or use one of the manual speed settings.
- Clean the air quality sensor inlet and outlet with a soft brush (fig. 34).
- Open the air quality sensor cover (fig. 35).
- Clean the air quality sensor, the dust inlet and the dust outlet with a lightly moistened cotton swab (fig. 36).
- Dry them with a dry cotton swab.
- Reattach the air quality sensor cover (fig. 37).
Cleaning the water tank, water tray and NanoCloud rotary humidification wick
Cleaning the water tank, water tray and NanoCloud rotary humidification wick every week to keep them hygienic.
- Pull out the water tank (fig. 10).
- Lift the water tray upwards and pull it out horizontally (fig. 11).
- Take the wick wheel off the wick support (fig. 38).
- Rinse the water tank, water tray and NanoCloud rotary humidification wick under a running tap.
Note- Do not take the NanoCloud rotary humidification wick off the wheel during cleaning.
- Do not scrub the NanoCloud rotary humidification wick or place it under direct sunlight.
- If necessary, use a mild detergent to clean the water tank and water tray. In this case, rinse the water tank and water tray thoroughly.
- Wipe the outside of the water tank and water tray dry.
- Place the wick wheel on the wick support (fig. 13).
Note
When placing the wick wheel on the wick support, make sure that the projections on the wick wheel falls into the corresponding grooves. - Place the water tray back into the appliance (fig. 14).
- Place the water tank back into the appliance (fig. 18).
Cleaning the pre-filter
If the pre-filter is damaged, worn or broken, do not use. Visit www.philips.com/support or contact the Consumer Care Center in your country
Filter alert light status | Follow this |
F0 displays on the screen and wick& pre- filter cleaning alert |
Clean the pre-filter |
- Pull the top part of the back panel towards you to release it from the appliance (fig. 3).
- To remove the pre-filter, press the clip down and pull the filter towards you (fig. 4).
- Wash the pre-filter under a running tap. If the pre-filter is very dirty, use a soft brush to brush away the dust (fig. 39).
- Air dry the pre-filter.
Note
Make sure that the pre-filter is completely dry. If it is still wet, bacteria may multiply in it and shorten the lifetime of the pre-filter. - After the pre-filter is completely dry, place it back into the back panel (fig. 8).
- Touch and hold
for 3 seconds to reset the pre-filter cleaning time.
Descaling the NanoCloud rotary humidification wick
Filter alert light status | Follow this |
F0 displays on the screen and wick& pre- filter cleaning alert |
Descale the NanoCloud rotary humidification wick (FY2425) |
- Pull out the water tank (fig. 10).
- Lift the water tray upwards and pull it out horizontally (fig. 11).
- Take the wick wheel off the wick support (fig. 38).
- Soak the NanoCloud rotary humidification wick in cleansing agent (e.g diluted white vinegar, Citric acid solution) for two hours (fig. 40).
Note- Please use mid or acid cleanser
- White vinegar (5% acetic acid) mix with equal amount of water
- 24g citric acid mix with 4L water
- If there are white deposits (limescale) on the filter, make sure that the side with the white deposits is immersed in the water.
- Do not take the NanoCloud rotary humidification wick off the wheel during descaling.
- Rinse the NanoCloud rotary humidificationwick under the tap to rinse away vinegar or citric acid residues.
During rinsing, turn the wick so that both front and back are rinsed (fig. 41). - Air dry the NanoCloud rotary humidification wick (fig. 42).
Note
Do not put the NanoCloud rotary humidification wick under direct sunlight. - Touch and hold
for 3 seconds to reset the NanoCloud rotary humidification wick cleaning time.
Replace the filter and wick
Understanding the healthy air protect lock
This appliance is equipped with the healthy air protect lock to make sure that the Nano protect filter and the humidification wick are in optimal condition when the appliance is operating. When the Nano protect filter and the humidification wick are almost expired, the replacement light
If you do not replace the filter and wick in time, the appliance will stop operating and get locked.
Replacing the NanoProtect filter (fig. 43)
- The filter is not washable or reusable.
- Always turn off the air purifier and unplug from the electrical outlet before replacing the filters.
Filter alert light status | Follow this |
A3 is displayed and the filter replacement light |
Replace the NanoProtect filter Series 3 (FY1410) |
C7 is displayed and the filter replacement light |
Replace the NanoProtect filter Active Carbon (FY1413) |
- Remove the used filters from the appliance (fig. 44).
Note- Do not touch the pleated filter surface, or smell the filters as they have collected pollutants from the air.
- Wash your hands after disposing of the used filters.
- Remove all packaging material of the new filters (fig. 6).
- Place the new filters into the appliance (fig. 7).
- Touch and hold
for 3 seconds to reset the NanoProtect filter lifetime counter.
Replacing the NanoCloud rotary humidification wick
Filter alert light status | Follow this |
F1 is displayed and the filter replacement light flashes on the screen (fig. 45). |
Replace the NanoCloud rotary humidification wick |
- Take the wick wheel off the wick support (fig. 38).
- Grip the shaft screw on the other side of the wheel, rotate it anticlockwise to release the wick from the wheel (fig. 46).
- Unfasten the locks on the edge of the wheel successively to disassemble the wick wheel (fig. 47).
- Take the used NanoCloud rotary humidification wick out (fig. 48).
- Remove all packaging material of the new NanoCloud rotary humidification wick (fig. 12).
- Place the new NanoCloud rotary humidification wick in the wick wheel, and then fasten the locks on the wick wheel (fig. 49).
- Place the wick wheel on the wick support (fig. 13).
Note
When placing the wick wheel on the wick support, make sure that the projections on the wick wheel falls into the corresponding grooves. - Place the water tray and water tank back into the appliance (fig. 14).
- Touch and hold
for 3 seconds to reset the NanoCloud rotary humidification wick lifetime counter.
Troubleshooting
This chapter summarizes the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, contact the Consumer Care Center in your country
Problem | Possible solution |
The appliance does not work even though it is plugged in. |
|
The appliance does not work even though it is switched on. | The appliance is working but the buttons are not responsive. Check if the child lock is on. |
There are some white deposits on the NanoCloud rotary humidification wick. | The white deposits are called scale and they consist of minerals from the water. Scale on the NanoCloud rotary humidification wick affects the humidifying performance, however it does not harm your health. Follow the cleaning instructions in the user manual. |
No air comes out of the air outlet. | Plug the appliance into the power supply and switch on. |
The airflow that comes out of the air outlet is significantly weaker than before. |
|
The air quality does not improve, even though the air purifier has been operating for a long time. |
|
It takes a long time to reach the target humidity level. | NanoCloud technology evenly distributes invisible water vapour into your room. In dry conditions moisture from the humidifier will be absorbed by walls, furniture, and other items in your room. Ventilation of dry outside air will also increase the time it takes to reach the target humidity. To optimize humidification and purification performance, it’s recommended to close doors and windows during use. |
I do not see water vapor coming out of the appliance. Is it working? | When mist is very fine, it is invisible. The appliance has a NanoCloud humidification technology, which produces healthy humid air from the outlet area without formation of water mist. Therefore, you cannot see the mist. |
The appliance produces a strange smell. |
|
The appliance is extra loud. |
|
The appliance still indicates that I need to replace a filter, but I already did. | Perhaps you did not touch and hold the Timer/Reset button correctly. Plug in the appliance, touch to switch on the appliance, and touch and hold the Timer/Reset button for 3 seconds. |
Error codes “E1”, “E2”, “E3”, “E4” or “E5” displays on the screen. | The appliance has malfunctions. Contact the Consumer Care Center in your country. |
The Wi-Fi setup is not successful. |
|
Guarantee and service
If you need information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Center in your country (you find its phone number in the worldwide guarantee leaflet). If there is no Consumer Care Centre in your country, go to your local Philips dealer.
Order parts or accessories
If you have to replace a part or want to purchase an additional part, go to your Philips dealer or visit www.philips.com/support.
If you have problems obtaining the parts, please contact the Philips Consumer Care Center in your country (you can find its phone number in the worldwide guarantee leaflet).
Notices
Electromagnetic fields (EMF)
This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.
Recycling
Follow your country’s rules for the separate collection of electrical and electronic products.
Correct disposal helps prevent negative consequences for the environment and human health..
Notice
App Store is a service mark of Apple Inc.
Google Play is a trademark of Google Inc.
This Philips appliance and Clean Home+ app applied multiple open source softwares, Copies of open source software license text used in this product can be derived from website www.philips.com/cleanhome.
Simplified EU declaration of conformity
Hereby, DAP B.V. declares that the radio equipment type AC2729 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.philips.com.