Frigidaire FHWE182WA2 Room Air Conditioner User Guide

FHWE182WA2 Room Air Conditioner
User Guide

Important Safety Instructions

NOTE:
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.

NOTE:
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire.
Please refer to the section ‘Operation of Current Device’ for details. In the event that the power supply cord is damaged, it cannot be repaired.
It must be replaced with a cord from the product manufacturer.

WARNING
Avoid fire hazards or electric shocks. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.

Grounding type wall receptacle

Power supply cord with 3-prong grounding plug and current detection device

SAFETY PRECAUTIONS

DANGER! Avoid Serious Injury or Death

  • This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
  • Do not insert or place fingers or objects into the air discharge area in the front of the unit.
  • Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
  • Do not cut or damage the power cord.
  • If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
  • In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized
  • Electrolux servicer.
  • Do not operate the air conditioner with wet hands.
  • Do not pull on the power cord.
  • Do not drink any water that is drained from the air conditioner.

WARNING

For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.

WARNING

Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:

  • Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
  • If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, remove the screen completely before installation.
  • Be sure the air conditioner has been securely and correctly installed according to the separate installation instructions provided with this manual. Save this manual and the installation instructions for possible future use in removing or reinstalling this unit. When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.

WARNING

Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.

  • Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
  • Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time-delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
  • Do not run the air conditioner without an outside protective cover in place. This could result in mechanical damage to the air conditioner.
  • Do not use an extension cord or an adapter plug.

SAFETY PRECAUTIONS

CAUTION! Avoid injury or damage to the unit or other property

  • Provide ventilation per installation instructions.
  • Do not direct airflow at fireplaces or other heat-related sources as this could cause flare-ups or make units run excessively.
  • Do not climb on or place objects on the outdoor part of the unit.
  • Do not hang objects off the unit.
  • Do not place containers with liquids on the unit.
  • Turn off the air conditioner at the power source when it will not be used for an extended period of time.
  • Periodically check the condition of the unit’s installation accessories for any damage.
  • Do not apply heavy pressure to the radiator fins of the unit.
  • Operate the unit with an air filter in place.
  • Do not block or cover the intake grille, discharge area, and outlet ports.
  • Ensure that any electrical/electronic equipment is one yard away from the unit.
  • Do not use or store flammable gases near the unit.
  • Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
  • Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
  • When cleaning the unit, first make sure that the power and circuit breaker are turned off.

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE THE AIR CONDITIONER.
The unit must be upright for one hour prior to operating.

Operation of Current Device

Plugin & press RESET

The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:

  1. Plugin the Air Conditioner.
  2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
  3. Press the RESET button. Again you will notice a click as the button engages.
  4. The power supply cord is now supplying electricity to the unit. (This is also indicated by a light on the plug head).

NOTE:

  • Do not use this device to turn the unit on or off.
  • Always make sure the RESET button is pushed in for a correct operation.
  • The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
  • If the power supply cord is damaged, it CAN NOT be repaired. It MUST be replaced by one obtained from the product manufacturer.

Explanation of symbols displayed on the unit

WARNING This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION This symbol shows that service personnel should be handling this equipment with reference to the installation manual.
CAUTION This symbol shows that information is available such as the operating manual or installation manual.

Important Safety Instructions

WARNING FOR FLAMMABLE REFRIGERANT

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example open flames, an operating gas appliance) and ignition sources or (for example an operating electric heater) close to the appliance. The appliance shall be stored in a room without continuously operating ignition sources (for example open flames,  an operating gas appliance, or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that the refrigerants may not contain an odor.
  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority,  which authorizes their competence to handle refrigerants safely in accordance with industry-recognized assessment specifications.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of a person competent in the use of flammable refrigerants.
  • DO NOT modify the length of the power cord or use an extension cord to power the unit.
  • DO NOT share a single outlet with other electrical appliances. An improper power supply can cause fire or electrical shock.
  • Please follow the instruction carefully to handle, install, clear, and service the air conditioner to avoid any damage or hazard.
    Flammable Refrigerant R32 is used within the air conditioner. When maintaining or disposing of the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, and shall not discharge into the air directly.
  • No open fire or device-like switch which may generate spark/arcing shall be around the air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
  • Flammable refrigerant – R32 is used in air conditioners. Please follow the instruction carefully to avoid any hazards.

CAUTION

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be installed in accordance with national wiring regulations.

Product Registration

Record Your Model and Serial Numbers

Record in the space provided below the model and serial numbers. On all models, the serial plate is located on the outside of the cabinet.

Model No. _________________________________________________
Serial No.__________________________________________________

Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed, and returned to the Frigidaire Company.

Packaging

Remove all packaging from inside the carton, along with any inserts placed into the side louvers.

Normal Sounds

Air Conditioner Features

ELECTRONIC CONTROL
Before you begin, thoroughly familiarize yourself with the control panel and remote as shown below and all its functions, then follow the symbol for the functions you desire.  The unit can be controlled by the touchpad alone or with the remote.

Light Feature: 
The display and all LED indicators on the control panel of the unit can be turned off by pressing the “Light” button on the remote control. If any other button of the control panel and remote control is pressed after that, the unit will beep to indicate it works as the corresponding direction of pressing a specific button, and the display and LED indicators will illuminate accordingly, but they will turn off again in 5 seconds if no further operation.
Pressing the “Light” button again will wake up the display and LED indicators.

Battery Size: AAA
Warning: Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
Caution for ingestion, Keep out of the reach of children.

Operating Instructions

NOTE
The following instructions represent the TouchPad, the same instructions can be used for the Remote Control.

TO TURN THE UNIT ON:

YOU WILL SEE:

NOTE: The unit will run in Cool mode with Eco feature and Auto fan speed setting when used for the first time.
With the Eco feature, when the room temperature is below the set temperature, the fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10-minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on. The Eco feature can be activated or deactivated by pressing the Eco button, but it is invalid in fan-only mode.

AUTO FEATURE:

YOU WILL SEE:

Note: This mode is a fixed combination of Cool mode and Auto fan speed setting. In this mode, the fan speed can not be selected manually.

COOL FEATURE:

YOU WILL SEE:

Note: In this mode, the fan remains on all the time with the compressor cycling on and off when the room temperature is reached.

TO CHANGE TEMPERATURE SETTlNG:

YOU WILL SEE:

Note: Tap or hold either the up () or down () button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between  62 °F (17 °C) and 86 °F (30 °C). If you want the display to read the actual room temperature. See the “To Operate on Fan Only” section on Page 8.

TO ADJUST FAN SPEEDS:

YOU WILL SEE:

Note: The fan speed can be selected among four settings:
Auto, Lo(Low), Med(Medium), and Hi(High), unless the unit runs in “Auto” or “Dry” mode, or the Sleep feature is activated.

TO OPERATE ON FAN ONLY:

YOU WILL SEE:

Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air on some models. (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.
During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.

DRY MODE:

YOU WILL SEE:

Note: In this mode, the air conditioner will work like a dehumidifier, but it will cool the room down meanwhile. The temperature can be adjusted between 62 °F (17 °C) and 86  °F (30 °C) and the fan speed will be held at “Lo”.

SLEEP FEATURE:

YOU WILL SEE:

Note: In this mode, the unit will select Auto fan speed automatically, and the selected temperature will increase by 2 °F 30 minutes after the mode is selected. The temperature will then increase by another 2 °F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature.  This ends the “Sleep” mode and the unit will continue to operate as originally programmed. The “Sleep” mode program can be cancelled at any time during operation by again pressing the “Sleep”, “Fan speed” or “Mode” button.

CHECK THE FILTER FEATURE, YOU WILL SEE:

Note: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “Filter Reset” button and the light will go off.

TIMER: DELAY STOP/START FEATURE

YOU WILL SEE HOW MUCH TIME IS CHOSEN:

To delay stop(or start), press the Timer button when the unit is power-on(or power-off), then the “timer off” indicator(or “timer on” indicator) will illuminate. Then adjust the timer setting, tap or hold the UP arrow () or the DOWN arrow () to change the delay timer at 0.5-hour increments, up to 10 hours, then at 1-hour increments up to 24 hours. The setting will be confirmed automatically in 5 seconds, then the control will count down the time(8, 7.5, 7, etc.) left, and all other settings will remain the same as they were before the timer setting is confirmed, until the stop(or start). Setting a combination of “delay stop delay start” or “delay start delay stop” is workable. Both the “timer off” indicator and “timer on” indicator will illuminate then. The timer setting can be canceled by either pressing and holding the timer button for 2 seconds, or pressing the power on/off button at any time to turn off the unit directly. turn off turn on

REMOTE SENSING FEATURE
(on some models):

NOTE: Unit display shows the set temperature

NOTE: Remote display is actual temperature at remote control only

Note: This feature can be activated from the remote control ONLY, the unit must be in a cooling mode.
To activate the remote sensing feature, point the remote control towards the unit and press the Remote Sensing button. Next, use the “” buttons to set the desired temperature on the remote. (Note that the set temperature will only be displayed on the unit itself ). The LIGHT on the unit control will illuminate to indicate it receives the signal. The  LIGHT on the remote control will pulse each time it sends a signal. lt will periodically send this signal until the feature is deactivated by pressing the remote sensing button gain. lf the unit does not receive the remote sensing signal during any 7-minute interval, the Remote Sensing feature will halt until the unit receives a signal from the remote control again. The display on the remote control indicates the temperature at the remote
ONLY. NOTE: The Remote Sensing function can be terminated either by pressing the  Remote Sensing button again or the main ON/OFF button on the unit.

FAULT CODES:

If the display reads “AS” , a sensor has failed. Contact your Authorized Frigidaire Service Center.

TO CHANGE THE TEMPERATURE DISPLAY:

YOU WILL SEE:

Note: The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.

TO TURN THE UNIT OFF:

YOU WILL SEE:

ADDITIONAL THINGS YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.

  • The “Cool” circuit has an automatic 3-minute time delayed start if the unit is turned off and on quickly.
    This prevents overheating of the compressor and possible circuit breaker tripping.
    The fan will continue to run during this time.
  • There is a 2-Second delay for the compressor shutting down when selecting FAN ONLY. This is to cover the possibility of having to roll through to select another model.
  • The control will maintain the set temperature within 2 degrees Fahrenheit, between 62F and 86F degrees.
  • After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.

Fresh Air Vent Control (on some models)
The Fresh Air Vent allows the air conditioner to:

  1. Recirculate inside air – Vent Closed (see Fig. 1)
  2. Draw fresh air into the room – Fresh Air (see Fig. 2)
  3. Exchange air from the room – Vent Open (see Fig. 3)

Air Directional Louvers
Air directional louvers control the air flow direction. Your air conditioner has the louver type described below.

Slider Type
The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed. Drag the adjuster tablet until the desired Left/Right direction is obtained. Pivot horizontal louvers until the desired Up/Down direction is obtained.

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning
The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.

  • Push the vent handle to the Vent Closed position(where applicable).
  • Open the front panel.
  • Grasp the filter by the center and pull it up and out.
    Wash the filter using liquid dishwashing detergent and warm water. Rinse the filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before  replacing
  • Or instead of washing, you may vacuum the filter clean.

NOTE: When replacing the air filter after cleaning, make sure the tabs on the air filter are on the upper part of the filter and placed outward as shown in the drawing on the left side.

Cabinet Cleaning

  • Be sure to unplug the air conditioner to prevent shock or fire hazards. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent.
    Rinse thoroughly and wipe dry.
  • Never use harsh cleaners, wax, or polish on the cabinet front.
  • Be sure to wring excess water from the cloth before wiping around the controls.
    Excess water in or around the controls may cause damage to the air conditioner.
  • Plug-in air conditioner.

Winter Storage
If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.

Energy Saving Ideas

  • Do not block airflow inside with blinds, curtains, or furniture; or outside with shrubs, enclosures, or other buildings.
  • The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation.
  • Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day.
  • Close the fireplace damper, floor, and wall register so cool air does not escape up the chimney and into the ductwork.
  • Keep blinds and drapes in other windows closed during the sunniest part of the day.
  • Clean the air filter as recommended in the section “Care and Cleaning”.
  • Proper insulation and weather stripping in your home will help keep warm air out and cool air in.
  • External house shading with trees, plants, or awnings will help reduce the air conditioner’s workload.
  • Operate heat-producing appliances such as ranges, washers, dryers, and dishwashers during the coolest part of the day.

Before You Call

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

OCCURRENCE SOLUTION
The air conditioner will not operate. The Wall plug disconnected. Push plug firmly into a wall outlet.
Plug Current Device Tripped. Press the RESET button.
The House fuse has blown or the circuit breaker tripped. Replace the fuse with time delay type or reset circuit breaker.
Control is OFF. Turn Control ON and set it to the desired setting.
The air from the unit does not feel cold enough. Room temperature below 62°F (17°C). Cooling may not occur until room temperature rises above 62°F (17°C).
Temperature sensing element touching cold coil, located behind the air filter. Straighten away from the coil.
Reset to a lower temperature.
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for the compressor to restart when set in the COOL mode.
Air conditioner cooling, but the room is too warm – ice forming
on cooling coil behind decorative front
Outdoor temperature below 62°F (17°C). To defrost the coil, set FAN ONLY mode.
An air filter may be dirty. Clean filter. Refer to the Care and Cleaning section. To defrost, set to FAN ONLY mode.
The temperature is set too low for night-time cooling. To defrost the coil, set it to FAN ONLY mode. Then, set the temperature to a higher setting.
Air conditioner cooling, but the room is too warm – NO ice forming on cooling coil behind decorative front Dirty air filter – air restricted. Clean air filter. Refer to the Care and Cleaning section.
The temperature is set too high. Set temperature to a lower setting.
Air directional louvers are positioned improperly. Position louvers for better air distribution.
The front of the unit is blocked by drapes, blinds, furniture, etc. – which restricts air distribution. Clear blockage in the front of the unit.
Doors, windows, registers, etc. open – cool air escapes. Close doors, windows, registers, etc.
The unit recently turned on in the hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor, and furniture.
The air conditioner turns on and off rapidly. Dirty air filter – air restricted. Clean air filter.
The outside temperature is extremely hot. Set FAN speed to a faster setting to bring air through cooling coils more frequently.
Noise when the unit is cooling. Air movement sound. This is normal. If too loud, set to lower FAN setting.
Window vibration – poor installation. Refer to installation instructions or check with the installer.
Water dripping INSIDE when the unit is cooling. Improper installation. Tilt the air conditioner slightly to the outside to allow water drainage. Refer to installation instructions or check with the installer.
Water dripping OUTSIDE when the unit is cooling. Unit removing a large quantity of moisture from the humid room. This is normal during excessively humid days.
Remote Sensing Deactivating Prematurely (some models). The remote control is not located within range. Place remote control within 20 feet & 120° radius of the front of the unit.
Remote control signal obstructed. Remove obstruction.
The room is too cold. Set temperature too low. Increase set temperature.
Remote Sensing activated (on some models) and remote control located in Hot Spot – Relocate remote control or deactivate remote sensing.

If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada)
For Frigidaire Service.

Major Appliance Limited Warranty

Your appliance is covered by a limited one-year warranty and a limited 2-5 year warranty on the sealed system (the compressor, condenser, evaporator, and tubing). For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions. From the second to the fifth year from your original purchase date,  Electrolux will repair or replace any parts in the Sealed Refrigeration System (compressor, condenser, evaporator, and tubing) that prove to be defective in materials or workmanship. In years 2-5, the consumer will be responsible for diagnostic, labor, and parts costs as well as any removal, transportation, and reinstallation expenses that are incurred during service on components other than those covered under the Sealed Refrigeration System 5-year warranty.

Exclusions

  1. Products with original serial numbers that have been removed, altered or cannot be readily determined.
    This warranty does not cover the following:
  2. The product that has been transferred from its original owner to another party or removed outside the USA or Canada.
  3. Rust on the interior or exterior of the unit.
  4. Products purchased “as-is” are not covered by this warranty.
  5. Food loss due to any refrigerator or freezer failures.
  6. Products used in a commercial setting.
  7. Service calls that do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than in accordance with the provided instructions.
  8. Service calls to correct the installation of your appliance or to instruct you how to use your appliance.
  9. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it is shipped from the factory.
  10. Service calls to repair or replace appliance light bulbs, air filters, water filters, other consumables, knobs, handles, or other cosmetic parts.
  11. Surcharges include but are not limited to, any after-hour, weekend, or holiday service calls, tolls, ferry trip charges, or mileage expenses for service calls to remote areas,  including the state of Alaska.
  12. Damages to the finish of appliance or home incurred during installation, including but not limited to floors, cabinets, walls, etc.
  13. Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such as abuse, misuse, inadequate power supply, accidents, fires, or acts of God.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED  HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,  ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE  LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY  BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION  OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

If You Need Service
Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.

This limited warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux  Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.

USA
1.800.944.9044
Electrolux Major Appliances
10200 David Taylor Drive
Charlotte, NC 28262
Canada
1.800.265.8352
Electrolux Canada Corp.
5855 Terry Fox Way
Mississauga, Ontario, Canada
L5V 3E4