SEALEY SCT03.V2 Ultrasonic Parts Cleaning Tanks Instruction Manual
ULTRASONIC PARTS CLEANING TANKS
3L / 9L / 27L.
MODEL NO’S: SCT03.V2, SCT09.V2, SCT27.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT IS CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE
SAFETY
1.1. ELECTRICAL SAFETY
WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before use. Inspect power supply leads, plugs and all electrical connections for wear and damage. Sealey recommends that an RCD (Residual Current Device) is used with all electrical products. You may obtain an RCD by contacting your local Sealey Stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.
For electrical safety information, it is important that the following information is read and understood.
1.1.1. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3. Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating in these instructions
× DO NOT pull or carry the appliance by the power cable.
× DO NOT pull the plug from the socket by the cable.
× DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a qualified electrician.
1.1.4. This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove it from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommends that repairs are carried out by a qualified electrician.
1.2. GENERAL SAFETY
× DO NOT run the cleaner continuously for more than one hour at a time, as doing so can damage the internal components.
× DO NOT operate the unit without fluid in the tank. Always ensure the fluid is no higher than 2/3rd full. Always ensure there is a minimum depth of 7cm.
× DO NOT drop any item into the tank as this may cause damage to the transducer. Always place the items gently into the tank and use the basket whenever possible.
× Never immerse the machine or power cord in water or other liquid.
× DO NOT touch the power plug with wet hands, especially when inserting or removing the plug.
× DO NOT touch the unit if the machine has fallen into the water during operation. Remove the power plug from the socket first.
× DO NOT disassemble the machine, except by professionals.
× DO NOT spray water or liquid over the device and the control panel.
× DO NOT operate the cleaner without proper grounding.
× DO NOT place the device on a soft surface, where the vents could be blocked.
INTRODUCTION
Perfect for cleaning all small hard parts. Widely used by jewellers, watch, bicycle, car and motorcycle repairers, plus precision and model engineers. An ultrasonic cleaner that achieves great results on delicate items such as watch parts, PCB boards and electrical components, as well as mechanical items such as carburettors, spark plugs and injectors. The Degas function purifies the liquid in the tank to speed up the cleaning process. Using ultrasonic wave vibration, the intense cleaning action of the microscopic bubbles can penetrate the most inaccessible parts to remove dirt and grime. Achieve a pristine condition without any damage or wear to the item. Made from durable stainless steel and fitted with a drain tap for easy emptying and a mesh basket to keep smaller components together. Features soft cleaning mode enabling you to clean your more fragile items. Recommended for use with Sealey Ultrasonic Cleaning fluids model no. SCT25D or SCT5D
SPECIFICATION
Model No. Maximum working capacity Minimum working capacity Motor power Overall dimensions (W x D x H) Supply Tank dimensions (W x D x H)
Model No. | SCT03.V2 | SCT09.V2 | SCT27.V2 |
Maximum working capacity | 3L | 9L | 27L |
Minimum working capacity | 2L | 5L | 14L |
Motor power | 120W | 240W | 600W |
Overall dimensions (W x D x H) | 265 x 165 x 225mm | 370 x 265 x 280mm | 580 x 325 x 335mm |
Supply | 240V | 240V | 240V |
Tank dimensions (W x D x H) | 240 x 135 x 100mm | 300 x 240 x 150mm | 500 x 300 x 200mm |
APPLICATION
WARNING! Provided the product is non-porous and can normally be immersed in water almost anything can be thoroughly cleaned. Here are some examples:
4.1. GOLD-SMITHERY AND SILVER-SMITHERY: Non-porous jewellery, Necklaces, bracelets, rings, precious stones, watch casings and straps, precision mechanical movements.
4.2. MANUFACTURING: Aerospace, Defence, Automotive, Marine, Filtration, Moulding, Plating & Surface Finishing, Semi-Conductors.
4.3. OPTICAL: During edging and polishing, debris and abrasives can scratch lenses. Ultrasonic cleaning can effectively protect the lenses.
4.4. REGENERATION: For cleaning dot matrix printers and photocopier ink cartridges.
4.5. MAINTENANCE: Bicycle gears, air purifiers. It cleans out debris in tiny holes and crevices effectively.
PREPARATION
5.1. Carefully unpack the cleaner and remove all traces of packing materials from it. Visually inspect the cleaner for any parts that may have become loose or damaged during transit.
5.2. Place the cleaner on a flat, clean surface where the cooling fans will receive adequate ventilation and ensure all controls are set to off. Also, ensure the drain tap is in the closed position.
5.3. Ensure the power cord is securely plugged into the cleaner and that no part is likely to come into contact with moisture.
5.4. Carefully fill 2/3rds of the tank with a solvent solution. For demanding cleaning we recommend a small amount of washing up liquid, this will help increase the cleaning performance. The cleaner is now ready for use.
DO NOT exceed the filling line. Be aware of the displacement volume of the objects being treated to avoid overspill.
WARNING! Items Not Suitable For Ultrasonic Cleaning:
Soft Jewellery: Pearls, emerald, ivory, coral. Agate, sea turtle shells, etc. Welded, Plated and Glued Items: Welded or plated metal items, glued items. Watches: Except diver’s watches with depth rating over 50m(150ft). Others: Ceramic, camera filters with pre-existing cracks.
OPERATION
6.1. SET UP
6.1.1. Select your cleaning solution and fill 2/3rds of the tank. DO NOT exceed the filling line. Be aware of the displacement volume of the objects being treated to avoid overspill.
▲ DANGER! DO NOT use alcohol, gasoline or flammable solutions. Doing so could cause a fire or explosion. Use only water-based solvents.
6.1.2. Place the items into the basket, Slowly lower the basket into the tank. DO NOT allow items to contact the tank bottom and always use the basket to immerse items. The solution should cover the items – see section 6.1.1.
6.1.3. A: Plug the cleaner into an (earthed) mains supply.
B: Turn the mains supply on and turn on the power switch on the rear side of the machine.
NOTE: After turning the power on, the value you see on the temperature display is the actual temperature. To see the set temperature of the solution, press the temperature button. The current time settings in minutes and seconds are shown in the double-width window.
6.2. TIMER
6.2.1. Press
NOTE: Time is shown in minutes and seconds (fig.1). Maximum timer setting is 30 minutes.
6.3. HEATING
6.3.1.Press
6.3.2. To get the best cleaning result, the solution’s temperature should be 40° to 60°C. Warm water and dishwashing liquid can soften
grease and improve cleaning results. The heating range is from 5oC to 80oC.
6.3.3. When setting the temperature, if you want the temperature of the bath to be higher than the current temperature, press
Heating does shut off automatically if the timer is used when the timer reaches zero.
6.4. DEGAS MODE
6.4.1. To degas a fresh solution, use the degas mode. Press the degas button 3 times within 3 seconds
6.4.2. The unit will cycle through 6-second and 3-second periods until the time reaches zero.
6.5. NORMAL MODE
6.5.1. After the timer and temperature setting, press
6.6. SOFT MODE
6.6.1. Set the timer and temperature, press
6.6.2. NOTE: Degas, Normal and Soft cannot be operated simultaneously.
6.7. In the event of failure/emergency, disconnect the main supply.
MAINTENANCE
7.1. When the cleaning is completed, unplug the power cord, open the lid and retrieve the basket and the items.
7.2. Empty the tank and clean both the outside and inside of the device with a clean, dry cloth before the next use. Keep the drainage valve closed. SCT09 and SCT27 have a 1/2” BSP Female drain tap.
WARNING: Strong acid or alkaline cleaning solution will cause corrosion, rust and even puncture of the tank or machine body. To overcome this problem, dilute to mild PH solution.
Parts support is available for this product. To obtain parts, please log on to www.sealey.co.uk, email or telephone 01284 757500
ENVIRONMENT PROTECTION
WEEE REGULATIONS
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team at or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
© Jack Sealey Limited