Whirlpool WEG515S0LV 5 Cu. Ft. Gas Range Instruction Manual
FOR SERVICE TECHNICIAN’S USE ONLY
ACTIVATING THE SERVICE DIAGNOSTIC MODES
- Enter Diagnostics mode by pressing CANCEL>CANCEL>START within a 5-second period.
- Press the “up” arrow keypad to scroll through the diagnostics settings.
NOTES:
■ Entering Diagnostics mode will cancel any active oven operation.
■ Enter the Diagnostics mode only after the oven is cool.
Electrical Shock Hazard
After performing voltage measurements, disconnect power before servicing.
Failure to follow these instructions can result in death or electrical shock.
WARNING
Electrical Shock Hazard
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
- Verify the controls are in the off position so that the appliance does not start when energized.
- Allow enough space to perform the voltage measurements without obstructions.
- Keep other people a safe distance away from the appliance to prevent potential injury.
- Always use the proper testing equipment.
- After voltage measurements, always disconnect power before servicing.
ERROR CODES
Code |
Description |
F1E0 Fl El F1E2 |
Internal board failure |
F2E1 | Shorted keypad Clavier en courtcircuit |
F3E0 | Oven sensor opened |
F5E0 | Door and switches do not agree (Clean mode) |
F5E1 | Door latch not operating (Clean mode) |
F6E1 | Oven over temperature when heating Depassement temperature four quand four chauffe |
F9E0 | Miswired house |
RESISTANCES
Component | Pinout | Resistance or Voltage |
Door switch Contacteur porte | P3-1 to P3-2 P3-1 a P3-2 |
2 VDC with door open 0 VDC with door closed 2 V CC, porte ouverte 0 V CC, porte fermee |
Oven temperature sensor | P3-4 to P3-5 P3-4 a P3-5 |
1000-1200 0 at room temperature 1000 – 1200 0 a temperature ambiante |
Oven light | P2-1 to WH (neutral) P1-3 P2-1 a BL (neutre) P1-3 |
0-40 0 nominal |
Door latch motor | P2-3 to WH (neutral) P1-3 P2-3 a BL (neutre) P1-3 |
500-3000 0 |
Convection fan motor | P2-2 to WH (neutral) P1-3 P2-2 a BL (neutre) P1-3 |
15-20 0 nominal |
DSI board Carte DSI | J1-4 to J1-6 / J1-4 a J1-6 J1-4 to J1-101 J1-4 a J1-10 J1-1 to J1-2 / J1-1 a J1-2 J1-4 to J1-7 / J1-4 a J1-7 J1-3 to J1-2 / J1-3 a J1-2 | 120 VAC /120 VCA 120 VAC / 120 VCA 216 0 nominal 120 VAC / 120 VCA 216 0 nominal |
Surface ignitors | L – N | 120 VAC 120 VCA |
RF | LF | RR | LR | Bake | Broil | |
5″ WC NAT. BTUs | 15000 | 15000 | 9500 | 5000 | 16500 | 4436 |
10″ WC PROPANE BTUs | 13500 | 13500 | 7500 | 4500 | 15500 | 4436 |
5″ WC NAT. WHs | 4396 | 4396 | 2784 | 1465 | 4836 | 1300 |
10″ WC PROPANE WHs | 3957 | 3957 | 2198 | 1319 | 4543 | 1300 |
W11508880A
IMPORTANT: Electrostatic discharge may cause damage to machine control electronics. Refer to online Tech Manual for additional information.
Check for proper voltage by completing the following steps:
- Disconnect the power or unplug the appliance.
- Connect voltage measurement equipment to proper connectors.
- Plug in appliance or reconnect power and confirm voltage reading.
- Disconnect the power or unplug the appliance.
COOKTOP
WIRE DIAGRAM
OVEN
LEGEND