FOR SERVICE TECHNICIAN’S USE ONLY

ACTIVATING THE SERVICE DIAGNOSTIC MODES

  1. Enter Diagnostics mode by pressing CANCEL>CANCEL>START within a 5-second period.
  2. Press the “up” arrow keypad to scroll through the diagnostics settings.

NOTES:

■ Entering Diagnostics mode will cancel any active oven operation.
■ Enter the Diagnostics mode only after the oven is cool.

warning 2 DANGER
Electrical Shock Hazard

Only authorized technicians should perform diagnostic voltage measurements.
After performing voltage measurements, disconnect power before servicing.
Failure to follow these instructions can result in death or electrical shock.

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:

  • Verify the controls are in the off position so that the appliance does not start when energized.
  • Allow enough space to perform the voltage measurements without obstructions.
  • Keep other people a safe distance away from the appliance to prevent potential injury.
  • Always use the proper testing equipment.
  • After voltage measurements, always disconnect power before servicing.

ERROR CODES

Code
No display

Description
Control not operational

F1E0
Fl El
F1E2
Internal board failure
F2E1 Shorted keypad Clavier en courtcircuit
F3E0 Oven sensor opened
F5E0 Door and switches do not agree (Clean mode)
F5E1 Door latch not operating (Clean mode)
F6E1 Oven over temperature when heating Depassement temperature four quand four chauffe
F9E0 Miswired house

RESISTANCES

Component  Pinout

Resistance or Voltage

Door switch Contacteur porte P3-1 to P3-2
P3-1 a P3-2
2 VDC with door open
0 VDC with door closed
2 V CC, porte ouverte
0 V CC, porte fermee
Oven temperature sensor P3-4 to P3-5
P3-4 a P3-5
1000-1200 0 at room temperature
1000 – 1200 0 a temperature ambiante
Oven light P2-1 to WH (neutral) P1-3
P2-1 a BL (neutre) P1-3
0-40 0 nominal
Door latch motor P2-3 to WH (neutral) P1-3
P2-3 a BL (neutre) P1-3
500-3000 0
Convection fan motor P2-2 to WH (neutral) P1-3
P2-2 a BL (neutre) P1-3
15-20 0 nominal
DSI board Carte DSI J1-4 to J1-6 / J1-4 a J1-6 J1-4 to J1-101 J1-4 a J1-10 J1-1 to J1-2 / J1-1 a J1-2 J1-4 to J1-7 / J1-4 a J1-7 J1-3 to J1-2 / J1-3 a J1-2 120 VAC /120 VCA
120 VAC / 120 VCA
216 0 nominal
120 VAC / 120 VCA
216 0 nominal
Surface ignitors L – N 120 VAC 120 VCA
RF  LF  RR LR Bake

Broil

5″ WC NAT. BTUs 15000 15000 9500 5000 16500 4436
10″ WC PROPANE BTUs 13500 13500 7500 4500 15500 4436
5″ WC NAT. WHs 4396 4396 2784 1465 4836 1300
10″ WC PROPANE WHs 3957 3957 2198 1319 4543 1300

W11508880A

IMPORTANT: Electrostatic discharge may cause damage to machine control electronics. Refer to online Tech Manual for additional information.
Check for proper voltage by completing the following steps:

  1. Disconnect the power or unplug the appliance.
  2. Connect voltage measurement equipment to proper connectors.
  3. Plug in appliance or reconnect power and confirm voltage reading.
  4. Disconnect the power or unplug the appliance.