INSTALLATION INSTRUCTIONS 27″ (68.6 CM) AND 30″ (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

INSTRUCTIONS D’INSTALLATION FOUR ÉLECTRIQUE ENCASTRÉ 27″ (68,6 CM) ET 30″ (76,2 CM) – SIMPLE ET DOUBLE

INSTRUCCIONES DE INSTALACIÓN DEL HORNO EMPOTRADO ELÉCTRICO SIMPLE Y DOBLE DE 27″ (68,6 CM) Y 30″ (76,2 CM)

Table of Contents/Table des matières/Índice

BUILT-IN OVEN SAFETY……………………. 2 INSTALLATION REQUIREMENTS………. 2
Tools and Parts……………………………….. 2 Location Requirements ……………………. 3 Electrical Requirements …………………… 6 INSTALLATION INSTRUCTIONS………… 7 Prepare Built-In Oven………………………. 7 Remove Oven Door(s) ……………………… 7 Replace Oven Door(s) ……………………… 8 Positioning Oven Feet for Multiple Cabinet Cutout Heights …………………… 8 Make Electrical Connection ……………. 13 Install Oven…………………………………… 14 Install Warming Drawer Deflector Kit.. 16 Complete Installation …………………….. 16

SÉCURITÉ DU FOUR ENCASTRÉ ……. 17 EXIGENCES D’INSTALLATION ………… 17
Outillage et pièces…………………………. 17 Exigences d’emplacement……………… 18 Spécifications électriques ………………. 21 INSTRUCTIONS D’INSTALLATION…… 22 Préparation du four encastré ………….. 22 Dépose de la/des porte(s) du four …… 22 Réinstallation la porte(s) du four ……… 23 Positionnement des pieds du four pour des ouvertures d’encastrement de hauteur différente ……………………… 24 Raccordement électrique……………….. 28 Installation du four…………………………. 30 Installation de l’ensemble de déflecteur du tiroir-réchaud ……………. 31 Achever l’installation ……………………… 32

SEGURIDAD DEL HORNO INTEGRADO………………………. 33 REQUISITOS DE INSTALACIÓN ………. 33
Herramientas y piezas……………………. 33 Requisitos de ubicación…………………. 34 Requisitos eléctricos……………………… 37 INSTRUCCIONES DE INSTALACIÓN .. 38 Prepare el horno integrado …………….. 38 Retire la puerta del horno……………….. 38 Vuelva a colocar la puerta del horno .. 39 Ubicación de las patas del horno para múltiples alturas de corte del armario ………………………. 39 Haga la conexión del suministro eléctrico ……………………….. 44 Instale el horno……………………………… 45 Instale el kit de deflector para cajón de calentamiento ………….. 47 Finalización de la instalación ………….. 47

IMPORTANT: Save for local electrical inspector’s use.
IMPORTANT : À conserver pour consultation par l’inspecteur local des installations électriques.
IMPORTANTE: Guarde para tener a disposición del inspector de electricidad local. W11129956A

BUILT-IN OVEN SAFETY

Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

DANGER

You can be killed or seriously injured if you don’t immediately follow instructions.

WARNING

You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed

Flush Installation Kit (for Single and Double installed at flush installation):

Color

Size

Type

Flush Installation Kit

Phillips screwdriver Measuring tape Hand or electric drill (for wall cabinet installations) 1″ (2.5 cm) drill bit (for wall cabinet installations) Level Flat-blade screwdriver
Parts Needed UL Listed or CSA Approved conduit connector UL Listed wire connectors Warming Drawer Deflector Kit (for ovens installed above a
warming drawer):

Color

Size

Type

Warming Drawer Deflector Kit

White

27″

White

30″

Black

27″

Black

30″

SS

27″

SS

30″

BSS

27″

BSS

30″

Bronze 30″

Single / Double Single / Double Single / Double Single / Double Single / Double Single / Double Single / Double Single / Double Single / Double

W11173681 W11173683 W11173685 W11173691 W11173693 W11123003 W11173700 W11173703 W11123005

To order, see the “Assistance or Service” section of the Use and Care Guide.

Parts Supplied

White

27″

White

30″

Black

27″

Black

30″

SS

27″

SS

30″

BSS

27″

Single / Double Single / Double Single / Double Single / Double Single / Double Single / Double Single / Double

W10510613 W10510614 W10531009 W10531010 W10536338 W10536339 W10888988

#8-14 x 3/4″ (19 mm) screws: single ovens (2), double ovens (4)
#8-18 x 3/8″ (9.5 mm) screws: bottom vent (2) #8-18 x 1/4″ (6.4 mm) screws: bottom vent trim (4) #8-18 x 3/8″ (9.5 mm) screws: double oven feet (4) Bottom vent Bottom vent trim Rear feet: double oven (2)

BSS

30″

Bronze 30″

Single / Double Single / Double

W10727416 W11123007

Front feet: double oven (2) Check local codes. Check existing electrical supply. See the “Electrical Requirements” section.

To order, see the “Assistance or Service” section of the Use and Care Guide.

It is required that all electrical connections be made by a licensed, qualified electrical installer.

2

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.

Product Dimensions — Single Ovens

Recessed installation area must provide complete enclosure around the recessed portion of the oven.

B

Grounded electrical supply is required. See the “Electrical Requirements” section.

Electrical supply junction box should be located 3″ (7.6 cm)

above the cutout or 3″ (7.6 cm) maximum below the support

surface when the oven is installed in a wall cabinet. A

1″ (2.5 cm) minimum diameter hole should have been drilled

F

in the right rear or left rear corner of the upper or lower

support surface to pass the appliance cable through to the

junction box.

NOTE: For undercounter installation, it is recommended

A

that the junction box be located in the adjacent right or

left cabinet. If you are installing the junction box on rear

wall behind oven, it is recommended that the junction box

be recessed and located in the upper center of the cabinet.

G C

Oven support surface must be solid, level, and flush with bottom of cabinet cutout.

Floor must be able to support a single oven weight of 129 lbs (59 kg) for 27″ (68.6 cm) models or 154 lbs (70 kg) for 30″ (76.2 cm) models.

D E

Floor must be able to support a double oven weight of 251 lbs (114 kg) for 27″ (68.6 cm) models or 288 lbs (131 kg) for 30″ (76.2 cm) models. IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate, or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Undercounter Installation (with Cooktop Installed Above): Refer to the Cutout Dimensions for Ovens Installed Under Cooktop (separate sheet). See product website for list of cooktop models approved for use above select wall-oven models.

27″ (68.6 cm) models
A. 283/4″ (72.8 cm) max. overall height
B. 257/16″ (64.6 cm) max. recessed width
C. 263/4″ (67.9 cm) recessed height
D. 231/4″ (59.1 cm) max. recessed depth
E. 27″ (68.6 cm) overall width
F. 12″ (30.5 cm) from back of control panel to start of strain relief
G. 48″ (121.9 cm) flexible conduit length

30″ (76.2 cm) models
A. 283/4″ (72.8 cm) max. overall height
B. 281/2″ (72.4 cm) max. recessed width
C. 263/4″ (67.9 cm) recessed height
D. 231/4″ (59.1 cm) max. recessed depth
E. 30″ (76.2 cm) overall width
F. 12″ (30.5 cm) from back of control panel to start of strain relief
G. 48″ (121.9 cm) flexible conduit length

3

Cabinet Dimensions — Single Ovens

Single Oven Undercounter (Without Cooktop Installed Above)

A

B

Single Ovens Installed in Cabinet A

E

27″ (68.6 cm) models
A. 27″ (68.6 cm) min. cabinet width
B. 11/2″ (3.8 cm) min. top of cutout to underside of countertop
C. 51/4″ (13.3 cm) bottom of cutout to floor
D. 251/2″ (64.8 cm) cutout width
E. 28″ (71.2 cm) min. cutout height

D C
30″ (76.2 cm) models
A. 30″ (76.2 cm) min. cabinet width
B. 11/2″ (3.8 cm) min. top of cutout to underside of countertop
C. 51/4″ (13.3 cm) bottom of cutout to floor
D. 281/2″ (72.4 cm) cutout width
E. 28″ (71.2 cm) min. cutout height

B D F G E
C

27″ (68.6 cm) models
A. 27″ (68.6 cm) min. cabinet width
B. 1″ (2.5 cm) top of cutout to bottom of upper cabinet door
C. 32″ (81.3 cm) bottom of cutout to floor
D. 251/2″ (64.8 cm) cutout width
E. 11/2″ (3.8 cm) min. bottom of cutout to top of cabinet door
F. 28″ (71.2 cm)* recommended cutout height
G. 24″ (60.7 cm) cutout depth

30″ (76.2 cm) models
A. 30″ (76.2 cm) min. cabinet width
B. 1″ (2.5 cm) top of cutout to bottom of upper cabinet door
C. 32″ (81.3 cm) bottom of cutout to floor
D. 281/2″ (72.4 cm) cutout width
E. 11/2″ (3.8 cm) min. bottom of cutout to top of cabinet door
F. 28″ (71.2 cm)* recommended cutout height
G. 24″ (60.7 cm) cutout depth

*NOTE: The cutout height can be between 2615/16″ and 297/16″ (68.4 cm and 74.8 cm) for single ovens.

4

Product Dimensions — Double Ovens B G
F

A

C

E

D

27″ (68.6 cm) models
A. 513/16″ (130.0 cm) max. overall height
B. 257/16″ (64.6 cm) max. recessed width
C. 4813/16″ (124.0 cm) recessed height
D. 231/4″ (59.1 cm) max. recessed depth
E. 27″ (68.6 cm) overall width
F. 12″ (30.5 cm) from back of control panel to start of strain relief
G. 66″ (167.6 cm) flexible conduit length

30″ (76.2 cm) models
A. 513/16″ (130.0 cm) max. overall height
B. 281/2″ (72.4 cm) max. recessed width
C. 4813/16″ (124.0 cm) recessed height
D. 231/4″ (59.1 cm) max. recessed depth
E. 30″ (76.2 cm) overall width
F. 12″ (30.5 cm) from back of control panel to start of strain relief
G. 66″ (167.6 cm) flexible conduit length

Cabinet Dimensions — Double Ovens Double Ovens Installed in Cabinet
A

B
D F

G E

C

27″ (68.6 cm) models
A. 27″ (68.6 cm) min. cabinet width
B. 1″ (2.5 cm) top of cutout to bottom of upper cabinet door
C. 143/4″ (37.5 cm) bottom of cutout to floor is recommended. 4-143/4″ (10.2-37.5 cm) bottom of cutout to floor is acceptable.
D. 251/2″ (64.8 cm) cutout width
E. 11/2″ (3.8 cm) min. bottom of cutout to top of cabinet door
F. 501/4″ (127.6 cm)* recommended cutout height
G. 24″ (60.7 cm) cutout depth

30″ (76.2 cm) models
A. 30″ (76.2 cm) min. cabinet width
B. 1″ (2.5 cm) top of cutout to bottom of upper cabinet door
C. 143/4″ (37.5 cm) bottom of cutout to floor is recommended. 4-143/4″ (10.2-37.5 cm) bottom of cutout to floor is acceptable.
D. 281/2″ (72.4 cm) cutout width
E. 11/2″ (3.8 cm) min. bottom of cutout to top of cabinet door
F. 501/4″ (127.6 cm)* recommended cutout height
G. 24″ (60.7 cm) cutout depth

*NOTE: The cutout height can be between 487/8″ and 523/16″ (124.1 cm and 132.6 cm) for double ovens.

5

Electrical Requirements

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and the wire gauge are in accordance with local codes. Check with a qualified electrical installer if you are not sure the oven is properly grounded. This oven must be connected to a grounded metal, permanent wiring system. Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 — latest edition or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91 — latest edition, and all local codes and ordinances. A copy of the above code standards can be obtained from:
National Fire Protection Association 1 Batterymarch Park
Quincy, MA 02169-7471

Models rated from 7.3 to 9.6 kW at 240 volts (6.3 to 8.3 kW at 208 volts) require a separate 40-amp circuit. Models rated from 4.9 to 7.2 kW at 240 volts (4.3 to 6.2 kW at 208 volts) require a separate 30-amp circuit. Models rated at 4.8 kW and below at 240 volts (4.2 kW and below at 208 volts) require a separate 20-amp circuit.
A circuit breaker is recommended. Connect directly to the circuit breaker box (or fused
disconnect) through flexible, armored, or nonmetallic sheathed, copper cable (with grounding wire). See the “Make Electrical Connection” section. Flexible conduit from the oven should be connected directly to the junction box. Fuse both sides of the line. Do not cut the conduit. The length of conduit provided is for serviceability of the oven.

CSA International 8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection To properly install your oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The model/serial/rating plate is located under the control panel on single ovens and under the control panel on the upper oven cavity on double ovens. See the following illustrations.

A UL Listed or CSA Approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure below: Connect the aluminum wiring using special connectors and/or tools designed and UL Listed for joining copper to aluminum. Follow the electrical connector manufacturer’s recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Series

Voltage

Frequency Rating

WOD97EC/ 120/240 V AC 60 Hz

8 kW

A

A

WODA7EC/ WOD77EC

120/208 V AC

60 Hz

6 kW

WOS97EC/ WOSA2EC/ WOS72EC

120/240 V AC 120/208 V AC

60 Hz 60 Hz

4 kW 3 kW

WOD51EC

120/240 V AC 60 Hz

7.6 kW

120/208 V AC 60 Hz

5.7 kW

WOS51EC

120/240 V AC 60 Hz

3.9 kW

Single Oven A. Model/serial/rating plate

Double Oven A. Model/serial/rating plate

120/208 V AC 60 Hz

2.9 kW

6

INSTALLATION INSTRUCTIONS

Prepare Built-In Oven
1. Decide on the final location for the oven. Avoid drilling or cutting into house wiring during installation.
WARNING

4. Gently start to close the door. The door will stop at a partially closed position.

Excessive Weight Hazard Use two or more people to move and install oven. Failure to do so can result in back or other injury.

2. To avoid floor damage, set the oven onto cardboard prior to installation. Do not use handle or any portion of the front frame for lifting.
3. Remove the shipping materials and tape from the oven. Remember to keep the corner posts and other materials that may be needed for installation.
4. Remove the hardware package from inside the bag containing literature.
5. Remove and set aside racks and other parts from inside the oven.
6. Move oven and cardboard close to the oven’s final location.
Remove Oven Door(s)
IMPORTANT: Use two hands to remove oven door. For double ovens, repeat the process for each door. 1. Prior to removing the oven door, prepare a surface where
you will place it. This surface should be flat and covered with a soft blanket, or use the corner posts from your packaging material. 2. Fully open the oven door.

5. Using two hands, grasp the edges of the oven door. Close the oven door slightly past the stop position to take the weight off of the door hinges, and then pull the oven door up.
6. Pull the oven door toward you, and then remove. You may need to gently shift the door from side to side as you pull.

Door hinges

3. Locate the oven door hinge locks in both corners of the oven door, and rotate the hinge locks toward the oven door to the unlocked position. If the door hinge lock is not rotated fully (see illustration B), the door will not remove properly.

Locked position

Unlocked position

7. Set the oven door aside on the prepared covered work surface with the oven door resting on its handle.
8. To continue with the oven installation, go to the “Positioning Oven Feet for Multiple Cabinet Cutout Heights” section.

Grip here to rotate.
A. Oven door hinge lock in locked position

Soft close hinge arm on select models
B. Oven door hinge lock in partially unlocked position

7

Replace Oven Door(s)
1. Using two hands, grasp side edges of door at the midpoint. Face the oven cavity.
2. Locate the slots on each side of the oven front frame for the door hinge locks.

5. Lower the oven door to the fully open position. If the oven door does not open to a full 90°, repeat steps 1 through 3.
6. Locate the oven door hinge locks in the corners of the oven door, and rotate the hinge locks toward the oven cavity to the locked position.

Unlocked position

Locked position

A
A. Slot in the oven cavity for door hinge lock 3. Using two hands, grasp the edges of the oven door. At a 45°
angle, insert the hinges at the same time, and push the oven door into the oven cavity slot to replace. You may need to gently shift the door from side to side as you push.
4. Make sure the door hinge notch is engaged on the bottom of the oven cavity slot.

Soft close hinge arm on select models
7. After the door hinges have been locked, gently swing the door upward to close. The door should not be forced closed.
8. When the hinges are properly installed and the door is closed, there should be an even gap between the door and the control panel. If one side of the oven door is lower than the other, the hinge on that side is not properly installed. See the “Remove Oven Door(s)” and “Replace Oven Door(s)” sections.
Positioning Oven Feet for Multiple Cabinet Cutout Heights
Single Ovens
The positioning of the oven feet allow a single oven to be installed in a cutout height between 2615/16″ and 297/16″ (68.4 cm and 74.8 cm). Refer to the following instructions to position the feet for the size of your cabinet cutout.
Cutout Height Is Between 275/8″ and 285/8″ (70.2 cm and 72.7 cm) The oven feet do not need to be changed. They are positioned correctly as received. Go to the “Make Electrical Connection” section.

IMPORTANT: Do not close the door at this step or damage may occur to the door hinge.

8

Cutout Height Is Between 2615/16″ and 2711/16″ (68.4 cm and 70.3 cm) 1. Using two or more people, place the oven on its back
on a covered surface.

Cutout Height Is Between 2811/16″ and 297/16″ (72.8 cm and 74.8 cm) 1. Using two or more people, place the oven on its back
on a covered surface.

2. Remove the foot from the right front spacer by removing the #8-18 x 3/8″ (9.5 mm) screw. NOTE: Do not remove the spacer.

2. Remove the foot from the right front spacer by removing the #8-18 x 3/8″ (9.5 mm) screw. NOTE: Do not remove the spacer.

A B
C
A. Spacer B. Foot C. #8-18 x 3/8″ (9.5 mm) screw
3. In the same manner, remove the feet on the right rear, left front, and left rear of the oven.
4. Using two or more people, place the oven in its upright position.

A B
C
A. Spacer B. Foot C. #8-18 x 3/8″ (9.5 mm) screw
3. Rotate the foot 90°, so the short side of the foot is positioned toward the top of the oven.

5. Go to the “Make Electrical Connection” section. 9

4. Reinstall the foot to the spacer using the #8-18 x 3/8″ (9.5 mm) screw previously removed.
5. In the same manner, remove, rotate, and reinstall the feet on the right rear, left front, and left rear of the oven.
6. Using two or more people, place the oven in its upright position.

Double Ovens
The positioning of the oven feet allow a double oven to be installed in a cutout height between 487/8″ and 523/16″ (124.1 cm and 132.6 cm). Refer to the following instructions to position the feet for the size of your cabinet cutout.
Cutout Height Is Between 487/8″ and 507/16″ (124.1 cm and 128.1 cm) The oven feet do not need to be installed. The oven is configured correctly as received. NOTE: Do not remove the spacers. Go to the “Make Electrical Connection” section.

7. Go to the “Make Electrical Connection” section.

A. Spacers

A A

10

Cutout Height Is Between 501/2″ and 511/8″ (128.2 cm and 129.9 cm) 1. Using two or more people, place the oven on its back
on a covered surface.

4. Install a front foot on the left front spacer using a #8-18 x 3/8″ (9.5 mm) screw. NOTE: Position the foot so the long side of the foot is facing toward the inside of the oven.

A

B

2. Install a foot on the left rear spacer using a #8-18 x 3/8″ (9.5 mm) screw. NOTE: Position the foot so the long side of the foot is facing toward the top of the oven.
A B

C
A. Front foot B. #8-18 x 3/8″ (9.5 mm) screw C. Spacer 5. In the same manner, install a front foot on the right front of the oven. 6. Using two or more people, place the oven in its upright position.

C
A. Spacer B. Foot C. #8-18 x 3/8″ (9.5 mm) screw
3. In the same manner, install a foot on the right rear of the oven.

7. Go to the “Make Electrical Connection” section. 11

Cutout Height Is Between 513/16″ and 523/16″ (130 cm and 132.6 cm) 1. Using two or more people, place the oven on its back
on a covered surface.

4. Install a front foot on the left front using a #8-18 x 3/8″ (9.5 mm) screw. NOTE: Position the foot so the long side of the foot is facing toward the top of the oven.

A

B

2. Install a foot on the left rear spacer using a #8-18 x 3/8″ (9.5 mm) screw.

NOTE: Position the foot so the short side of the foot is facing

C

toward the top of the oven.

A
B
C
A. Spacer B. Foot C. #8-18 x 3/8″ (9.5 mm) screw 3. In the same manner, install a foot on the right rear of the oven.

A. Front foot B. #8-18 x 3/8″ (9.5 mm) screw C. Spacer
5. In the same manner, install a front foot on the right front of the oven.
6. Using two or more people, place the oven in its upright position.

7. Go to the “Make Electrical Connection” section. 12

For Double Ovens

Make Electrical Connection
For Single Ovens

WARNING

WARNING

Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper wire. Electrically ground oven. Failure to follow these instructions can result in death, fire, or electrical shock.
This oven is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare) ground wire twisted together. 1. Disconnect power. 2. Feed the flexible conduit from the oven through
the opening in the cabinet. 3. Remove junction box cover if it is present. 4. Install a UL Listed or CSA Approved conduit connector
to the junction box.
A

Electrical Shock Hazard Disconnect power before servicing. Use 12 gauge copper wire. Electrically ground oven. Failure to follow these instructions can result in death, fire, or electrical shock.

4-Wire Cable from Home Power Supply

IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction, and in Canada.

A

B

E

F G

A. UL Listed or CSA Approved conduit connector

5. Route the flexible conduit from the oven to the junction box through a UL Listed or CSA Approved conduit connector.
6. Tighten screws on conduit connector. 7. See the “Electrical Connection Options Chart” to complete
installation for your type of electrical connection.
Electrical Connection Options Chart

If your home has: 4-wire

Go to section: 4-Wire Cable from Home Power Supply

3-wire

½” (1.3 cm)

3-Wire Cable from Home Power Supply

½” (1.3 cm)

H
C I
D

A. Cable from home power supply B. Black wires C. Red wires D. 4-wire flexible conduit
from oven E. Junction box

F. White wires
G. UL Listed wire connectors
H. Green (or bare) ground wires
I. UL Listed or CSA Approved conduit connector

1. Connect the two black wires (B) together using a UL Listed wire connector.
2. Connect the two red wires (C) together using a UL Listed wire connector.
3. Untwist white wire from green (or bare) ground wire coming from the oven.
4. Connect the two white wires (F) together using a UL Listed wire connector.
5. Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL Listed wire connector.
6. Install junction box cover.

13

3-Wire Cable from Home Power Supply: U.S. Only

IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a 3-wire connection.

A

B

C

G

H

D

E
I F

A. Cable from home power supply B. Junction box C. Black wires D. White wires E. Green (or bare) ground
wire (from oven)

F. 4-wire flexible conduit from oven
G. Red wires
H. UL Listed wire connectors
I. UL Listed or CSA Approved conduit connector

1. Connect the two black wires (C) together using a UL Listed wire connector.
2. Connect the two white wires (D) and the green (or bare) ground wire (of the oven cable) using a UL Listed wire connector.
3. Connect the two red wires (G) together using a UL Listed wire connector.
4. Install junction box cover.

Install Oven
1. Using two or more people, lift the oven partially into the cabinet cutout. Use the oven opening as an area to grip. NOTE: Push against seal area of the oven front frame when pushing the oven into the cabinet. Do not push against the outside edges.

2. Push against the seal area of the front frame to push the oven into the cabinet until the back surface of the front frame touches the front wall of the cabinet.
3. Push oven completely into the cabinet and center the oven into the cabinet cutout.
4. Remove the tape from the black front trim, and remove the zip tie from the mounting spacer. Securely fasten the oven to the cabinet using the #8-14 x 1″ (2.5 cm) screws provided. Insert the screws through holes in black trim, aligning with the holes in oven frame and mounting spacers already in place. Do not overtighten screws.
A B
B
C D
A. Oven frame B. Mounting spacer C. Oven frame hole D. Black trim piece

14

5. The bottom vent and bottom vent trim (required when the oven is installed with the feet in the tall position) are shipped in the foam packing at the top of the oven. To install only the bottom vent, see the following instructions. To install both the bottom vent and the bottom vent trim for installations with the feet in the tall position, see the instructions in Step 6. Align vent tab (B) with oven frame (A) as shown. Using one #8-18 x 3/8″ (9.5 mm) screw (D) on each side of the vent tab (B), fasten the vent securely to the oven.

Align vent tab (B) with oven frame (A) as shown. Using one #8-18 x 3/8″ (9.5 mm) screw (E) on each side
of the vent tab (B), fasten the vent securely to the oven.
A

A

B

D
A. Oven frame B. Vent tab

C
C. Oven vent D. #8-18 x 3/8″
(9.5 mm) screws

6. On models with the feet installed in the tall position, the bottom vent trim must also be installed. See the following instructions to install. Flex the upper vent piece (C) away from the lower vent piece (D) to slide the bottom vent trim (B) between them. Some force may be required to flex the upper vent trim (C) away from the lower vent trim (D). Some force may also be required to flex the bottom vent trim (B) and slide it into position. Make sure screw holes are properly aligned between the two pieces. See the following illustration. Install the bottom vent trim (B) to the lower vent piece (D) using two #8-18 x 1/4″ (6.4 mm) screws on each side. A
B

C

B

E D
A. Oven frame B. Vent tab C. Oven vent

C
D. Bottom vent trim E. #8-18 x 3/8″
(9.5 mm) screw

7. Replace the oven racks. 8. Replace the oven door. See the “Replace Oven
Door(s)” section. 9. Check that the door is free to open and close. If it is not,
repeat the removal and installation procedures. See the “Prepare Built-In Oven” section. 10. Repeat for lower oven door. 11. Reconnect power. 12. The display panel will light briefly, and “PF” should appear in the display. 13. If the display panel does not light, reference the “Warranty” section of the Use and Care Guide.

B

D

C D

A. #8-18 x 1/4″ (6.4 mm) screw
B. Bottom vent trim

C. Upper vent piece D. Lower vent piece

15

Install Warming Drawer Deflector Kit
(Only for Ovens Installed Above Warming Drawers)
On single and double oven models installed above a warming drawer, a warming drawer deflector kit must be installed. See the “Tools and Parts” section for information on ordering.
Parts Supplied in Deflector Kit A

4. Using one #8-18 x 3/8″ (9.5 mm) screw (E) on each side of the vent tab (B), fasten the vent securely to the oven. A

B
A. Phillips-head screws (4) only 2 screws for 27″ (68.6 cm) size
B. Warming drawer deflector (1)
Install Deflector Kit 1. Flex the upper vent piece (C) away from the lower vent piece
(D) to slide the warming drawer deflector (B) between them. Some force may be required to flex the upper vent trim (C) away from the lower vent trim (D). Some force may also be required to flex the warming drawer deflector (B) and slide it into position. Make sure screw holes are properly aligned between the two pieces. See the following illustration. 2. Install the warming drawer deflector (B) to the lower vent piece (D) using two #8-18 x 1/4″ (6.4 mm) screws on each side. NOTE: On 27″ (68.6 cm) models, only one #8-18 x 1/4″ (6.4 mm) screw is used on each side.
A
B
C

B

D

C D

A. #8-18 x 1/4″ (6.4 mm) screws C. Upper vent piece

B. Warming drawer deflector

D. Lower vent piece

3. Align vent tab (B) with oven frame (A) as shown in the following illustration.

B

E D
A. Oven frame B. Vent tab C. Oven vent

C
D. Warming drawer deflector E. #8-18 x 3/8″ (9.5 mm)
screw

Complete Installation
1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2. Check that you have all of your tools. 3. Dispose of/recycle all packaging materials. 4. For oven use and cleaning, read the Use and Care Guide.
Check Operation of Single and Double Ovens 1. At first use, set up the language, clock, and any other
preferences if available. For more information, read the Use and Care Guide. 2. Press OVEN on single oven models. NOTE: Press UPPER or LOWER on double oven models. 3. Select Cooking Methods. 4. Select Broil. 5. Set the temperature. 6. Select Start. If Oven(s) Does Not Operate, Check the Following:
Household fuse is intact and tight, or circuit breaker has not tripped.
Electrical supply is connected.
See the “Troubleshooting” section in the Use and Care Guide.
7. When oven has been on for 5 minutes, feel for heat. If you do not feel heat or if an error message appears in the display, turn off the oven and contact a qualified technician.
8. Press UPPER or LOWER on double ovens, or press OVEN on single ovens, to cancel.
If You Need Assistance or Service: Please reference the “Warranty” section of the Use and Care Guide.

16

SÉCURITÉ DU FOUR ENCASTRÉ

Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer.
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou “AVERTISSEMENT”. Ces mots signifient :

DANGER

Risque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions.

AVERTISSEMENT

Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions.

Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et ce qui peut se produire en cas de non-respect des instructions.

EXIGENCES D’INSTALLATION

Outillage et pièces

Rassembler les outils et composants nécessaires avant d’entreprendre l’installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous. Outils nécessaires
Tournevis Phillips Mètre ruban Perceuse manuelle ou électrique (pour installation dans un
placard mural)

Ensemble d’installation en affleurement (pour four simple et double installé en affleurement)

Couleur

Taille Type

Blanc Blanc

27″

Simple/Double

30″

Simple/Double

Trousse pour installation en affleurement W11173681 W11173683

Foret de 1″ (2,5 cm) (pour installation dans un placard mural) Niveau Tournevis à lame plate
Pièces nécessaires
Connecteur de conduit (homologation UL ou CSA) Connecteurs de fils (homologation UL) Ensemble de déflecteur pour tiroir-réchaud (pour les fours
installés par-dessus un tiroir-réchaud)

Couleur Taille Type

Blanc

27″

Blanc

30″

Noir

27″

Noir

30″

Acier inox. 27″

Acier inox. 30″

Bronze/

27″

acier inox.

Bronze/

30″

acier inox.

Bronze

30″

Simple/Double Simple/Double Simple/Double Simple/Double Simple/Double Simple/Double Simple/Double
Simple/Double
Simple/Double

Trousse de déflecteur pour tiroir-réchaud W10510613 W10510614 W10531009 W10531010 W10536338 W10536339 W10888988
W10727416
W11123007

Noir

27″

Noir

30″

Acier inox. 27″

Acier inox. 30″

Bronze/

27″

acier inox.

Bronze/

30″

acier inox.

Bronze

30″

Simple/Double Simple/Double Simple/Double Simple/Double Simple/Double
Simple/Double
Simple/Double

W11173685 W11173691 W11173693 W11123003 W11173700
W11173703
W11123005

Pour commander, voir la section “Assistance ou service” du Guide d’utilisation et d’entretien. Pièces fournies Vis n° 8-14 x 3/4″ (19 mm) : four simple (2), four double (4) Vis n° 8-18 x 3/8″ (9,5 mm) : évent inférieur (2) Vis n° 8-18 x 1/4″ (6,4 mm) : garniture de l’évent inférieur (4) Vis n° 8-18 x 3/8″ (9,5 mm) : pieds du four double (4) Évent inférieur Garniture de l’évent Pieds arrière : four double (2) Pieds avant : four double (2) Consulter les codes locaux. Vérifier l’alimentation électrique existante. Voir la section “Spécifications électriques”.

Pour commander, voir la section “Assistance ou service” du Guide d’utilisation et d’entretien.

Tous les raccordements électriques doivent être effectués par un électricien qualifié agréé.

17

Exigences d’emplacement

IMPORTANT : Observer les dispositions de tous les codes et règlements en vigueur.

Dimensions du produit — Fours simples

Respecter les dimensions indiquées pour les ouvertures

à découper dans les placards. Ces dimensions prennent

en compte les dégagements de séparation nécessaires.

B

L’espace d’installation doit permettre la formation d’une enceinte complète autour de la partie encastrée du four.

Une source d’électricité avec liaison à la terre est nécessaire. Voir la section “Spécifications électriques”.

G

Le boîtier de raccordement doit être situé 3″ (7,6 cm) audessus de l’ouverture d’encastrement ou à un maximum 3″ (7,6 cm) au-dessous de la surface de support lorsque le four est installé dans un placard mural. Un trou de diamètre 1″ (2,5 cm) ou plus doit avoir été percé dans la partie supérieure de l’angle arrière gauche ou droit de la surface de la paroi latérale pour le passage du câble d’alimentation de l’appareil jusqu’au boîtier de connexion. REMARQUE : Pour l’installation sous un plan de travail, on recommande que le boîtier de connexion soit situé dans le placard adjacent, à droite ou à gauche. Dans le cas de l’installation du boîtier de connexion sur le mur arrière, derrière le four, le boîtier de connexion doit être encastré et placé au centre de la partie supérieure du placard.
La surface de support du four doit être robuste, horizontale et en affleurement avec le bas de l’ouverture découpée dans le placard.
Le plancher doit pouvoir supporter le poids d’un four simple de 129 lb (59 kg) pour les modèles de 27″ (68,6 cm) ou 154 lb (70 kg) pour les modèles de 30″ (76,2 cm).
Le plancher doit pouvoir supporter le poids d’un four double de 251 lb (114 kg) pour les modèles de 27″ (68,6 cm) ou 288 lb (131 kg) pour les modèles de 30″ (76,2 cm). IMPORTANT : Afin d’éviter d’endommager les placards, consulter le constructeur de la maison ou le fabricant des placards pour déterminer si les matériaux utilisés peuvent subir un changement de couleur, une déstratification ou d’autres dommages. Ce four a été conçu conformément aux exigences des normes UL et CSA International et respecte les températures maximales permises de 194 °F (90 °C) pour les placards en bois.

F
C A

D E

Modèles de 27″ (68,6 cm)
A. Hauteur hors-tout 283/4″ (72,8 cm) max.
B. Largeur d’encastrement 257/16″ (64,6 cm) max.
C. Hauteur d’encastrement 263/4″ (67,9 cm)
D. Profondeur d’encastrement 231/4″ (59,1 cm) max.
E. Largeur hors-tout 27″ (68,6 cm)
F. 12″ (30,5 cm) de l’arrière du tableau de commande jusqu’à l’extrémité avant du serre-câble
G. 48″ (121,9 cm) de longueur du conduit flexible

Modèles de 30″ (76,2 cm)
A. Hauteur hors-tout 283/4″ (72,8 cm) max.
B. Largeur d’encastrement 281/2″ (72,4 cm) max.
C. Hauteur d’encastrement 263/4″ (67,9 cm)
D. Profondeur d’encastrement 231/4″ (59,1 cm)
E. Largeur hors-tout 30″ (76,2 cm)
F. 12″ (30,5 cm) de l’arrière du tableau de commande jusqu’à l’extrémité avant du serre-câble
G. 48″ (121,9 cm) de longueur du conduit flexible

Installation sous un plan de travail (avec table de cuisson installée au-dessus) :

Consulter “Four installé sous la table de cuisson — Dimensions pour l’ouverture à découper” (document distinct) Voir le site Web du produit pour la liste des modèles de table de cuisson approuvés pour une utilisation au-dessus des modèles de four mural de sélection.

18

Dimensions du placard — Fours simples

Four simple sous le plan de travail (sans table de cuisson au-dessus)

A

B

Fours simples installés dans un placard A

E

D C

Modèles de 27″ (68,6 cm)
A. Largeur du placard 27″ (68,6 cm) min.
B. 11/2″ (3,8 cm) min. entre le sommet de l’ouverture découpée et la face inférieure du plan de travail
C. 51/4″ (13,3 cm) entre le bas de l’ouverture découpée et le sol
D. Largeur de l’ouverture découpée 251/2″ (64,8 cm)
E. Hauteur de l’ouverture découpée 28″ (71,2 cm) min.

Modèles de 30″ (76,2 cm)
A. Largeur du placard 30″ (76,2 cm) min.
B. 11/2″ (3,8 cm) min. entre le sommet de l’ouverture découpée et la face inférieure du plan de travail
C. 51/4″ (13,3 cm) entre le bas de l’ouverture découpée et le sol
D. Largeur de l’ouverture découpée 281/2″ (72,4 cm)
E. Hauteur de l’ouverture découpée 28″ (71,2 cm) min.

B D F G E
C

Modèles de 27″ (68,6 cm)
A. Largeur du placard 27″ (68,6 cm) min.
B. 1″ (2,5 cm) entre le sommet de l’ouverture découpée et le bas de la porte du placard supérieur
C. 32″ (81,3 cm) entre le bas de l’ouverture découpée et le sol
D. Largeur de l’ouverture découpée 251/2″ (64,8 cm)
E. 11/2″ (3,8 cm) min. entre le bas de l’ouverture découpée et le sommet de la porte du placard
F. Hauteur de l’ouverture découpée recommandée 28″ (71,2 cm)*
G. Profondeur de l’ouverture 24″ (60,7 cm)

Modèles de 30″ (76,2 cm)
A. Largeur du placard 30″ (76,2 cm) min.
B. 1″ (2,5 cm) entre le sommet de l’ouverture découpée et le bas de la porte du placard supérieur
C. 32″ (81,3 cm) entre le bas de l’ouverture découpée et le sol
D. Largeur de l’ouverture découpée 281/2″ (72,4 cm)
E. 11/2″ (3,8 cm) min. entre le bas de l’ouverture découpée et le sommet de la porte du placard
F. Hauteur de l’ouverture découpée recommandée 28″ (71,2 cm)*
G. Profondeur de l’ouverture 24″ (60,7 cm)

*REMARQUE : Pour les fours simples, la hauteur de l’ouverture découpée peut être comprise entre 2615/16″ et 297/16″ (68,4 cm et 74,8 cm).

19

Dimensions du produit — Fours doubles B G
F

A

C

E

D

Modèles de 27″ (68,6 cm)
A. Hauteur hors-tout 513/16″ (130,0 cm) max.
B. Largeur d’encastrement 257/16″ (64,6 cm) max.
C. Hauteur d’encastrement 4813/16″ (124,0 cm)
D. Profondeur d’encastrement 231/4″ (59,1 cm) max.
E. Largeur hors-tout 27″ (68,6 cm)
F. 12″ (30,5 cm) de l’arrière du tableau de commande jusqu’à l’extrémité avant du serre-câble
G. 66″ (167,6 cm) de longueur du conduit flexible

Modèles de 30″ (76,2 cm)
A. Hauteur hors-tout 513/16″ (130,0 cm) max.
B. Largeur d’encastrement 281/2″ (72,4 cm) max.
C. Hauteur d’encastrement 4813/16″ (124,0 cm)
D. Profondeur d’encastrement 231/4″ (59,1 cm) max.
E. Largeur hors-tout 30″ (76,2 cm)
F. 12″ (30,5 cm) de l’arrière du tableau de commande jusqu’à l’extrémité avant du serre-câble
G. 66″ (167,6 cm) de longueur du conduit flexible

Dimensions du placard — Fours doubles Fours doubles installés dans un placard
A

B
D F

G E

C

Modèles de 27″ (68,6 cm)
A. Largeur du placard 27″ (68,6 cm) min.
B. 1″ (2,5 cm) entre le sommet de l’ouverture découpée et la porte du placard supérieur
C. 143/4″ (37,5 cm) entre le bas de l’ouverture découpée et le sol est la distance recommandée. 4-143/4″ (10,2-37,5 cm) entre le bas de l’ouverture découpée et le sol est une distance acceptable.
D. Largeur de l’ouverture découpée 251/2″ (64,8 cm)
E. 11/2″ (3,8 cm) min. entre le bas de l’ouverture découpée et le sommet de la porte du placard
F. Hauteur de l’ouverture découpée recommandée 501/4″ (127,6 cm) min.*
G. Profondeur de l’ouverture 24″ (60,7 cm)

Modèles de 30″ (76,2 cm)
A. Largeur du placard 30″ (76,2 cm) min.
B. 1″ (2,5 cm) entre le sommet de l’ouverture découpée et la porte du placard supérieur
C. 143/4″ (37,5 cm) entre le bas de l’ouverture découpée et le sol est la distance recommandée. 4-143/4″ (10,2-37,5 cm) entre le bas de l’ouverture découpée et le sol est une distance acceptable.
D. Largeur de l’ouverture découpée 281/2″ (72,4 cm)
E. 11/2″ (3,8 cm) min. entre le bas de l’ouverture découpée et le sommet de la porte du placard
F. Hauteur de l’ouverture découpée recommandée 501/4″ (127,6 cm) min.*
G. Profondeur de l’ouverture 24″ (60,7 cm)

*REMARQUE : Pour les fours doubles, la hauteur de l’ouverture découpée peut être comprise entre 487/8″ et 523/16″ (124,1 cm et 132,6 cm).

20

Spécifications électriques

Si on utilise un conducteur distinct de liaison à la terre lorsque les codes le permettent, il est recommandé qu’un électricien qualifié vérifie que la liaison à la terre et le calibre pour fils sont conformes aux codes locaux. En cas de doute quant à la qualité de la liaison à la terre du four, consulter un électricien qualifié. Ce four doit être raccordé à un système permanent, métallique de câblage relié à la terre. S’assurer que la connexion électrique et le calibre des fils sont appropriés et conformes au National Electrical Code, aux normes ANSI/NFPA 70 — dernière édition, ou aux normes CSA C22.1-94, au Code canadien de l’électricité, Partie 1 et C22.2 N° O-M91 — dernière édition, et à tous les codes et règlements locaux. Pour obtenir un exemplaire de la norme des codes ci-dessus, contacter :
National Fire Protection Association 1 Batterymarch Park
Quincy, MA 02169-7471 CSA International
8501 East Pleasant Valley Road Cleveland, OH 44131-5575
Raccordement électrique Pour installer le four correctement, il faut établir le type de raccords électriques que l’on utilisera et suivre les instructions indiquées ici.
Le four doit être alimenté par une source d’électricité appropriée (caractéristiques de tension et fréquence spécifiées sur la plaque signalétique). La plaque signalétique est située sous le tableau de commande pour les fours simples et sous le tableau de commande de la cavité supérieure du four pour les fours doubles. Voir l’illustration ci-dessous.

A

A

Les modèles à 240 volts de 7,3 à 9,6 kW (208 volts de 6,3 à 8,3 kW) doivent être alimentés par un circuit indépendant de 40 A. Les modèles à 240 volts de 4,9 à 7,2 kW (208 volts de 4,3 à 6,2 kW) doivent être alimentés par un circuit indépendant de 30 A. Un modèle à 240 volts de 4,8 kW ou moins (208 volts de 4,2 kW ou moins) doit être alimenté par un circuit indépendant de 20 A.
On recommande d’utiliser un disjoncteur. Raccorder l’appareil directement au coupe-circuit avec
fusible ou au disjoncteur par un câble à conducteur de cuivre et gaine métallique flexible ou gaine non métallique (avec conducteur de liaison à la terre). Voir la section “Raccordement électrique”. Le câble blindé flexible du four doit être connecté directement dans le boîtier de connexion. Protéger par fusible les deux extrémités de la ligne. Ne pas couper le conduit. La longueur du conduit fournie est destinée à faciliter l’entretien du four. L’installateur doit fournir un connecteur de conduit (homologation UL ou CSA). Si le domicile est équipé d’un câblage en aluminium, suivre les instructions suivantes : Connecter le câblage en aluminium en utilisant des connecteurs et/ou des outils spécialement conçus et homologués UL pour fixer le cuivre à l’aluminium. Appliquer la procédure recommandée par le fabricant des connecteurs. La connexion aluminium/cuivre doit être conforme aux codes locaux et aux pratiques de câblage acceptées par l’industrie.

Séries WOD97EC/ WODA7EC/ WOD77EC WOS97EC/ WOSA2EC/ WOS72EC

Tension 120/240 V CA 120/208 V CA
120/240 V CA 120/208 V CA

Fréquence 60 Hz 60 Hz
60 Hz 60 Hz

Évaluation 8 kW 6 kW
4 kW 3 kW

WOD51EC

120/240 V CA 60 Hz

7.6 kW

120/208 V CA 60 Hz

5.7 kW

WOS51EC

120/240 V CA 60 Hz

3.9 kW

Four simple
A. Plaque signalétique

Four double
A. Plaque signalétique

120/208 V CA 60 Hz

2.9 kW

21

INSTRUCTIONS D’INSTALLATION

Préparation du four encastré
1. Choisir l’emplacement final pour l’installation du four. Éviter de percer ou d’endommager le câblage lors de l’installation.
AVERTISSEMENT
Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer le four. Le non-respect de cette instruction peut causer une blessure au dos ou d’autre blessure.
2. Pour éviter d’endommager le plancher, placer le four sur une feuille de carton avant l’installation. Lors des opérations de levage, ne pas prendre prise sur la poignée ou sur une autre partie du châssis avant.
3. Enlever les matériaux d’emballage et les rubans adhésifs du four. S’assurer de bien conserver les cornières de protection et autres matériaux pouvant être requis pour l’installation.
4. Enlever le sachet de matériel à l’intérieur du sachet de documentation.
5. Enlever et conserver à part les grilles et autres composants qu’on trouve à l’intérieur du four.
6. Approcher le four et la feuille de carton de l’emplacement final du four.

3. Identifier les loquets de charnière de la porte du four dans les 2 angles de la porte; faire pivoter les loquets de charnière vers la porte du four jusqu’à la position de déverrouillage. Si le loquet de charnière de porte n’est pas complètement tourné (voir illustration B), la porte ne seretirera pas correctement.

Position verrouillée

Position déverrouillée

Tenir ici pour faire pivoter
A. Loquet de charnière de la porte du four en position de verrouillage

Bras de charnière pour fermeture douce sur
certains modèles
B. Loquet de charnière de la porte du four en position de déverrouillage partiel

4. Commencer à fermer doucement la porte. La porte s’arrêtera en position partiellement fermée.

Dépose de la/des porte(s) du four
IMPORTANT : Retirer la porte du four avec les deux mains. Pour les fours doubles, répéter le procédé pour chaque porte. 1. Avant de retirer la porte du four, préparer une surface sur
laquelle on pourra la poser. Cette surface doit être plate et recouverte d’une couverture douce. On peut aussi utiliser les cornières de l’emballage. 2. Ouvrir complètement la porte du four.

Charnières de porte

5. Saisir les bords de la porte du four avec les deux mains. Fermer la porte du four légèrement dépassé la position d’arrêt pour réduire la charge supportée par les loquets, puis tirer la porte de four vers le haut.

22

6. Tirer la porte du four vers soi et enlever la porte. Si nécessaire, basculer doucement la port d’un côté et de l’autre en la tirant.

4. S’assurer que les encoches de charnière de la porte sont engagées au fond des fentes de la cavité du four.

7. Conserver la/les porte(s) du four à part sur la surface de travail couverte en faisant reposer la porte sur sa poignée.
8. Pour continuer l’installation du four, aller à la section “Positionnement des pieds du four”.
Réinstallation de la porte(s) du four
1. Saisir les bords latéraux de la porte par le milieu avec les 2 mains. Se placer face à la cavité du four.
2. Repérer les encoches situées de chaque côté de la cavité du four pour les loquets de charnière de la porte.

IMPORTANT : Ne par fermer la porte à cette étape pour ne pas endommager les loquets de la porte. 5. Abaisser la porte du four jusqu’à ce qu’elle soit complètement ouverte. Si la porte du four ne s’ouvre pas complètement à un angle de 90 degrés, répéter les étapes 1 à 3. 6. Identifier les loquets de charnière de la porte du four dans les angles de la porte; faire pivoter les loquets de charnière vers la cavité du four jusqu’à la position de verrouillage.

Position déverrouillée

Position verrouillée

A
A. Encoche située dans la cavité du four pour le loquet de charnière de la porte
3. Saisir les bords de la porte du four avec les deux mains. Avec un angle de 45°, insérer les charnières en même temps et pousser la porte du four dans les fentes de la cavité du four pour la réinstaller. Si nécessaire, basculer doucement la porte d’un côté et de l’autre en la poussant.

Bras de charnière pour fermeture douce sur
certains modèles
7. Après que les charnières de la porte ont été verrouillées, fermer doucement la porte. La fermeture de la porte ne doit pas être forcée.
8. Une fois les charnières correctement installées et la porte fermée, il doit y avoir un espace égal entre la porte et le tableau de commande. Si l’un des côtés de la porte du four est plus bas que l’autre, la charnière de ce côté-ci n’est pas correctement installée. Voir les sections “Dépose la porte(s) du four” et “Réinstallation de la porte(s) du four.”

23

Positionnement des pieds du four pour des ouvertures d’encastrement de hauteur différente

Four simple En modifiant le positionnement des pieds du four, on peut installer un four simple dans une cavité d’encastrement d’une hauteur comprise entre 2615/16″ et 297/16″ (68,4 cm et 74,8 cm). Consulter les instructions suivantes pour adapter la position des pieds à la taille de la cavité d’encastrement.

2. Retirer le pied de la cale d’espacement avant droite en ôtant la vis n° 8-18 x 3/8″ (9,5 mm). REMARQUE : Ne pas retirer la cale d’espacement.

La hauteur d’encastrement est comprise entre 275/8″ et 285/8″ (70,2 cm et 72,7 cm) Les pieds du four n’ont pas besoin d’être remplacés. Ils sont correctement positionnés à leur sortie d’usine. Passer à la section “Raccordement électrique”.

A B
C

A. Cale d’espacement B. Pied C. Vis n° 8-18 x 3/8″ (9,5 mm)

3. Enlever les pieds installés au niveau avant gauche, arrière droit et arrière gauche du four en suivant la même méthode.
4. À l’aide d’au moins deux personnes, placer le four en position verticale.

La hauteur de la cavité d’encastrement est comprise entre 2615/16″ et 2711/16″ (68,4 cm et 70,3 cm) 1. À l’aide d’au moins deux personnes, placer le four sur
sa partie arrière, sur une surface couverte.
5. Passer à la section “Raccordement électrique”. La hauteur de la cavité d’encastrement est comprise entre 2811/16″ et 297/16″ (72,8 cm et 74,8 cm) 1. À l’aide d’au moins deux personnes, placer le four sur
sa partie arrière, sur une surface couverte.

24

2. Retirer le pied de la cale d’espacement avant droite en ôtant la vis n° 8-18 x 3/8″ (9,5 mm). REMARQUE : Ne pas retirer la cale d’espacement.
A B C
A. Cale d’espacement B. Pied C. Vis n° 8-18 x 3/8″ (9,5 mm) 3. Faire pivoter le pied à 90° de façon à ce que le côté court du pied soit orienté vers le sommet du four.

Fours doubles
En modifiant le positionnement des pieds du four, on peut installer un four double dans une cavité d’encastrement d’une hauteur comprise entre 487/8″ et 523/16″ (124,1 cm et 132,6 cm). Consulter les instructions suivantes pour adapter la position des pieds à la taille de la cavité d’encastrement.
La hauteur de la cavité d’encastrement est comprise entre 487/8″ et 507/16″ (124,1 cm et 128,1 cm) Il n’est pas nécessaire d’installer les pieds du four. Le four a été correctement configuré à sa sortie d’usine. REMARQUE : Ne pas retirer les cales d’espacement. Passer à la section “Raccordement électrique”.

4. Réinstaller le pied de la cale d’espacement à l’aide de la vis n° 8-18 x 3/8″ (9,5 mm) précédemment retirée.
5. Enlever, faire pivoter et réinstaller les pieds installés au niveau avant gauche, arrière droit et arrière gauche du four en suivant la même méthode.
6. À l’aide d’au moins deux personnes, placer le four en position verticale.

A
A
A. Cales d’espacement
La hauteur de la cavité d’encastrement est comprise entre 501/2″ et 511/8