Safety Instructions

All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool unrecognizable. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

  • Warning! If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.
  • The measuring tool is delivered with a laser warning sign (marked in the illustration of the measuring tool on the graphics page).
  • If the text of the laser warning label is not in your national language, stick the provided warning label in your national language over it before operating for the first time.
  • Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes.
  • Do not make any modifications to the laser equipment.
  • Do not use the laser goggles (accessory) as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles (accessory) as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colors.
  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts? This will ensure that the safety of the measuring tool is maintained.
  • Do not let children use the laser measuring tool unsupervised. They could unintentionally blind themselves or other persons.
  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.
  • The measuring tool is equipped with a wireless interface. Local operating restrictions, e.g. in airplanes or hospitals, must be observed.
    The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Robert Bosch Power Tools GmbH is under li-cense.
  • Caution! When using the measuring tool with Bluetooth®, a fault may occur in other devices and systems, airplanes and medical devices (e.g. pacemakers, hearing aids). Also, damage to people and animals in the immediate vicinity can-not be completely excluded. Do not use the measuring tool with Bluetooth® in the vicinity of medical devices, petrol stations, chemical plants, areas with a potentially explosive atmosphere and in blasting areas. Do not use the measuring tool with Bluetooth® on airplanes. Avoid using the product near your body for extended periods.

Product Description and Specifications

Intended Use
The measuring tool is intended for measuring distances, lengths, heights and clearances, and for calculating areas, volumes and heights.
The measuring tool is suitable for indoor use.
The measuring results can be transferred to other devices via Bluetooth®.

Product Features
The numbering of the product features refers to the representation of the measuring tool in the images.

  1. Plus button
  2. Function button
  3.  Bluetooth® button
  4. Measuring button
  5. Display
  6. Reference level selection button
  7. Minus button
  8. On/off button
  9. Battery compartment cover
  10. Battery compartment cover locking mechanism
  11. Serial number
  12. Reception lens
  13. Laser beam output
  14. Laser warning label
  15. Protective bag

Display elements

  • (a) Bluetooth® status
    Bluetooth® activated, connection not established
    Bluetooth® activated, connection established
  • (b) Battery indicator
  • (c) Measured value lines
  • (d) Result line
  • (e) Laser switched on
  • (f) Reference level of measurement
  • (g) Measuring function display
  • (h) Error display “Error”

Technical data

Article number 3 603 F72 1.. 3 603 F72 3..
Measuring rangeA) 0.05−30 m 0.05−40 m
Measuring accuracyB) ±2.0 mm ±2.0 mm
Operating temperature –10 °C to +40 °C –10 °C to +40 °C
Storage temperature –20 °C to +70 °C –20 °C to +70 °C
Relative air humidity max. 90 % 90 %
Max. altitude 2000 m 2000 m
Pollution degree according to IEC 61010-1 2C) 2C)
Laser class 2 2
Laser type 635 nm, < 1 mW 635 nm, < 1 mW
Divergence of the laser beam < 1.5 mrad (full

angle)

< 1.5 mrad (full

angle)

Automatic switch-off after approx.    
– Laser 20 s 20 s
– Measuring tool (without measurement)D) 5 min 5 min
Bluetooth® (when inactive) 3 min 3 min
Batteries 2 × 1.5 V LR03

(AAA)

2 × 1.5 V LR03

(AAA)

Digital laser measure

Bluetooth® Bluetooth® 4.2 (Low Energy)E) Bluetooth® 4.2 (Low Energy)E)
Operating frequency range 2402–2480 MHz 2402–2480 MHz
Max. transmission power 2.5 mW 2.5 mW
  • A) When measuring from the front edge. In unfavorable conditions such as very strong lighting, a temperature greatly deviating from 25 °C or a poorly reflecting surface, the measuring range can be restricted.
  • B) In unfavorable conditions such as strong lighting, high altitudes, or a poorly reflecting surface, the maximum deviation can be ±4 mm with a deviation of ±0.15 mm/m. In favorable conditions, a deviation of ±0.05 mm/m needs to be taken into account.
  • C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
  • D) Bluetooth® deactivated
  • E) When using Bluetooth® Low Energy devices, it may not be possible to establish a connection depending on the model and operating system. Bluetooth® tools must support the GATT profile.

The serial number (11) on the type plate is used to clearly identify your measuring tool.

Inserting/Changing the Battery

Always replace all the non-rechargeable batteries at the same time. Only use non-rechargeable batteries from the same manufacturer and which have the same capacity.

When inserting the batteries, ensure that the polarity is correct according to the illustration on the inside of the battery compartment.

Take the non-rechargeable batteries out of the measuring tool if you are not using it for a long time. The non-rechargeable batteries can corrode and self-discharge during prolonged storage.

Operation

Start-Up

  • Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be dazzled by the laser beam.
  • Protect the measuring tool from moisture and direct sunlight.
  • Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case English | 19
    of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
  • Avoid substantial knocks to the measuring tool and avoid dropping it. After strong external influences on the measuring tool, you should always carry out an accuracy check (see “Accuracy Check”, page 21) before further work.

Switching On and Off

Press the button to switch on the measuring tool.
You can also switch on the measuring tool by pressing the button. Upon switching on the measuring tool, the laser beam is not yet switched on. Press and hold the button to switch off the measuring tool.

If no button on the measuring tool is pressed for approx. 5 min, the measuring tool will switch off automatically to preserve the non-rechargeable batteries.

Measuring Process

Once switched on, the measuring tool is in the length measurement function.
Once the measuring tool has been switched on, the rear edge of the measuring tool is selected as the reference level for measurement. You can change the reference level. (see “Selecting the Reference Level”, page 20)

  • Apply the measuring tool to the point at which you want to start the measurement (e.g. wall).
  • Press the button to start the measurement.

Then the laser beam is switched off. For further measurement, repeat this process. Measured values or end results can be added or subtracted.
In the continuous measurement function, the measurement begins immediately after the first press of the button.

For more information, you can access the online operating instructions at www.bosch-pt.com/manuals

The measuring tool must not be moved during a measurement (with the exception of the continuous measurement function). The measuring tool should, therefore, ideally be placed by or on the measurement points.

The reception lens (12) and the laser beam output (13) must not be covered during the measuring process.

Selecting the Reference Level

For the measurement, you can select from various reference levels:

  • The rear edge of the measuring tool (e.g. when placing against walls)
  • The front edge of the measuring tool (e.g. when measuring from a table edge)
  • For more information, you can access the online operating instructions at www.bosch-pt.com/manuals

Measuring functions
Selecting/Changing Measuring Function
You will find the following functions in the Functions menu:

Bluetooth® interface

Activating the Bluetooth® interface for transmitting data to a mobile device

The connection status and the (a) active connection are shown in the display (5).
Bosch apps are available to expand the range of functions. These can be downloaded in the respective app stores, depending on the device.
The connection between the mobile devices and measuring tools is established after the Bosch application has started. If multiple active measuring tools are found, select the appropriate measuring tool using the serial number. You can find the serial number (11) on your measuring tool’s type plate.
If no connection can be established within 3 minutes after pressing the button, Bluetooth® switches off automatically to preserve the non-re-chargeable batteries/rechargeable batteries.

Deactivating the Bluetooth® interface
Press the button to deactivate Bluetooth®, or switch the measuring tool off.

Accuracy Check
Regularly check the accuracy of the measuring tool.

For more information, you can access the online operating instructions at www.bosch-pt.com/manuals

Error Message
The measuring tool monitors correct operation in every measurement. If a defect is detected, the display will indicate only the symbol shown opposite and the measuring tool switches itself off. In this case, have the measuring tool checked by an after-sales service agent for Bosch power tools?

Maintenance and Service

Maintenance and Cleaning
Only store and transport the measuring tool in the protective bag provided.
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.
Take particular care of the reception lens (12), which must be handled with the same level of care you would give to a pair of glasses or a camera lens.
If the measuring tool needs to be repaired, send it off in the protective bag (15).

After-Sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. You can find explosion drawings and information on spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you with any questions about our products and their accessories.
In all correspondence and spare parts orders, please always include the 10‑digit article number given on the nameplate of the product.

Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: [email protected]

You can find further service addresses at:
www.bosch-pt.com/serviceaddresses

Disposal
Measuring tools, battery packs/batteries, accessories and packaging should be sorted for environmentally friendly recycling.

Do not dispose of the measuring tools or rechargeable/non-rechargeable batteries with household waste.

Only for EU countries:
According to the Directive 2012/19/EU, measuring tools that are no longer usable, and according to the Directive 2006/66/EC, defective or used battery packs/batteries, must be collected separately and disposed of in an environmentally correct manner.

Further information for South Africa
PLR 40 C
You can have the ICASA certification logo shown in the display of the measuring tool.