Thank you for purchasing a Sealey product. Manufactured to a high standard this product will if used according to these instructions and properly maintained, give you years of trouble-free performance.
SAFETY INSTRUCTIONS
p WARNING! Disconnect from air supply before changing accessories or servicing.
INTRODUCTION & SPECIFICATIONS
Composite lightweight molded housing reduces the effects of chill on the operator’s hands. Fully reversible with thumb control set above motor housing. Air motor with quality bearings for smooth powerful operation. Handle exhaust with a built-in muffler reduces noise level. Fitted with Jacob’s keyless chuck for fast bit changes. Suitable for the professional workshop.
Chuck size …………….. 10mm
Free speed …………… 1800rpm
Air consumption ……………4cfm
Operating pressure…………90psi
Air inlet size ………….. 1/4” BSP
Weight ………………..1.15kg
Noise Power …………….83dB.A
PREPARING DRILL FOR USE
3.1. Air Supply
3.1.1. Ensure the drill air valve (or trigger) is in the “off” position before connecting to the air supply.
3.1.2. You will require air pressure of 90psi, and airflow according to specification.
3.1.3. Drain the air tank daily. Water in the airline will damage the drill.
3.1.4. Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig 1.
3.1.5. Line pressure should be increased to compensate for unusually long air hoses (over 8 meters). The minimum hose diameter should be 1/4” internal diameter and fittings must have compatible dimensions.
3.1.6. Keep the hose away from heat, oil, and sharp edges. Check the hose for wear, and make certain that all connections are secure.
3.2. Couplings.
Vibration may cause failure if a quick change coupling is connected directly to the drill. To overcome this, connect a leader hose to the drill (Sealey ref: AH2R or AH2R/38). A quick change coupling may then be used to connect the leader hose to the airline recoil hose.
See fig 1 & fig 2.
OPERATING INSTRUCTIONS
4.1. Turn front of chuck head to open, insert drill bit and turn chuck head to lock drill bit.
4.2. Connect the drill to the air hose as in Section 3.
4.3. The drill direction is changed by switching the forward-reverse lever above the motor housing. Check that the drill is set to operate in the required direction.
4.4. Depress the trigger to operate then drill accordingly.
DO NOT allow the drill to free run for an extended period of time as this will shorten its life.
MAINTENANCE
Non-authorized parts may be dangerous and will invalidate the warranty.
5.1. Lubricate the air drill daily with a few drops of Sealey air tool oil dripped into the air inlet to prolong its life.
5.2. Clean the drill after use.
5.3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the airline. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy check the air supply and follow instructions in Section 3.
b) Grit or gum deposits in the drill may also reduce performance. If your model has an air strainer (located in the area of the air inlet), remove the strainer and clean it. Flush the drill out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin. Allow drying before use.
5.4. For a full-service contact your local Sealey service agent.
5.5. When not in use, disconnect from the air supply, clean the drill, and store it in a safe, dry, childproof location.
Risk of Hand Arm Vibration Injury.
The SA620.V2 Air Pistol Drill with 10mm Keyless Chuck Composite Premier when operated in accordance with these instructions and tested in accordance with BS EN ISO 28927-5:2009 results in the following vibration emission declared in accordance with BS EN12096: 1996.
Measured vibration emission value: …………………. 3.3m/s²
Uncertainty: ……………………………………. 1.32m/s²
These values are suitable for comparison with emission levels of other tools that have been subject to the same test.
This tool may cause hand-arm vibration syndrome if its use is inadequately managed.
Recommended Measures to reduce the risk of hand-arm vibration syndrome: This item represents a low Hand Arm Vibration risk to users. The calculated maximum usage period exceeds 8 hours. We recommend appropriate safety equipment is utilized and regular breaks for the operator are employed to reduce any residual risk of fatigue or repetitive strain injury.
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email or phone 01284 757500.
NOTE: It is our policy to continually improve products and as such, we reserve the right to alter data, specifications, and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalog and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor, Sealey Group, Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR