Bosch 2103133 Home and Garden Quigo Green Cross Line Laser Instructions


Quigo green
Original instructions
1 609 92A 4RH | (06.11.2018)

Bosch Power Tools

Safety Instructions

All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool unrecognizable. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

  • Warning! If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.
  • The measuring tool is delivered with a warning label (marked in the illustration of the measuring tool on the graphics page).
  • If the text on the warning label is not in your native language, cover it with the label supplied, which is in your language, before initial commissioning.
    Do not direct the laser beam at persons or animals and do not look directly into the laser beam or at its reflection. Doing so could lead to blindness, or could cause accidents or damage to the eyes.
  • If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.
  • Do not make any modifications to the laser equipment.
  • Do not use the laser goggles as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colors.
  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.
  • Do not let children use the laser measuring tool unsupervised. They could accidentally dazzle someone.
  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids,  gases or dust. Sparks may be produced inside the measuring tool, which can
    ignite dust or fumes.
  • Keep the measuring tool away from cardiac pacemakers. The magnet inside the measuring tool generates a field that can impair the function of cardiac pacemakers.
  • Keep the measuring tool away from magnetic data carriers and magnetically sensitive equipment. The effect of the magnet can lead to irreversible data loss.

Product Description and Specifications

Please observe the illustrations at the beginning of this operating manual.
Intended Use
The measuring tool is intended for determining and checking horizontal and vertical lines.
The measuring tool is suitable for indoor use.

Product features

The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.

(1) 1/4″ mount of the adapter plate (9) Serial number
(2) Fine adjustment screw of the adapter plate (10) Locking mechanism of the battery compartment cover
(3) Adapter plate (11) TripodA
(4) On/off switch (12) Laser viewing glasses A)
(5) Laser beam outlet aperture (13) 1/4″ screw of the holder
(6) 1/4″ tripod mount (14) Locking screw of the holder
(7) Battery compartment cover (15) Fastening screw of the holder
(8) Laser warning label (16) Holder

A) Accessories shown or described are not included with the product as standard. You can find the complete selection of accessories in our accessories range.

Cross-line laser Quigo green
Article number 3 603 F63 C..
Working range at leastA 12 m
Leveling accuracy ±0.8 mm/m
Typical self-leveling range ±4°
Typical leveling time 6 s
Operating temperature +5 °C to +40 °C
Storage temperature −20 °C to +70 °C
Cross line laser Quigo green
Max. altitude 2000 m
Max. relative humidity 90 %
Pollution degree according to IEC 61010-1 B)
Laser class 2
Laser type 2
C6 500−540 nm, <5 mW
Divergence 5
Tripod mount 25 × 5 mrad (full angle)
Batteries 1/4″
Operating time, approx. 2 × 1.5 V LR3 (AAA)
Weight according to EPTA-Procedure 01:2014 >2 h
– Cross line laser 0.27 kg
– Holder 0.20 kg
Dimensions (length × width × height) 65 × 65 × 65 mm

A) The working range may be reduced by unfavorable environmental conditions (e.g. direct sunlight).
B) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number (9) on the type plate is used to clearly identify your measuring tool.

Assembly

Inserting/changing the batteries It is recommended that you use alkaline manganese batteries to operate the measuring tool. Push the locking mechanism (10) in the direction of the arrow to open the battery compartment cover (7) and remove the battery compartment cover. Insert the batteries supplied. When inserting the batteries, ensure that the polarity is correct according to the illustration on the inside of the battery compartment. If the batteries become weak, the laser lines will flash quickly for a few seconds. Always replace all the batteries at the same time. Only use batteries from the same manufacturer and which have the same capacity.

  • Take the batteries out of the measuring tool when you are not using it for a prolonged period of time. The batteries can corrode and self-discharge during prolonged storage.

Operation

Start-up

  • Protect the measuring tool from moisture and direct sunlight.
  • Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
  • Avoid substantial knocks to the measuring tool and avoid dropping it. Damaging the measuring tool can cause accuracy to be compromised. If the laser line is subjected to a substantial knock or is dropped, check it by comparing it to a known horizontal or vertical reference line.
  • Switch the measuring tool off when transporting it. The pendulum unit is locked when the tool is switched off, as it can otherwise be damaged by big movements.

Switching on/off
To switch on the measuring tool, push the on/off switch (4) up. Immediately after switching on, the measuring tool sends two laser lines out of the outlet aperture (5).

  • Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself (even from a distance). To switch off the measuring tool, push the on/off switch (4) downward over the laser beam outlet aperture (5). The pendulum unit is locked when the tool is switched off.
  • Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be blinded by the laser beam.

Automatic leveling
To work with automatic leveling, position the measuring tool on a level, firm surface or attach it to the holder (16) or the tripod (11). After switching on, the automatic leveling function automatically compensates for irregularities within the self-leveling range of ±4°. The leveling is finished as soon as the laser lines stop flashing.
If automatic leveling is not possible, e.g. because the underside of the measuring tool deviates by more than 4° from the horizontal plane or the measuring tool is held freely in the hand, the laser lines will continuously flash slowly and the measuring tool will work without automatic leveling. The laser lines remain switched on, but the two intersecting lines will no longer necessarily be perpendicular to each other. To make sure that the two laser lines are still perpendicular to one another, position the measuring tool at an angle of 90° to the wall. To work with automatic leveling again, position the measuring tool so that the underside is aligned horizontally and wait for the self-leveling to be performed. As soon as the measuring tool is within the self-leveling range of ±4° and is leveled in, the laser lines will light up continuously again. In case of ground vibrations or position changes during operation, the measuring tool is automatically leveled again. Upon re-leveling, check the position of the horizontal or vertical laser line with regard to the reference points to avoid errors by moving the measuring tool.
Practical Advice

  • Only the centre of the laser line must be used for marking. The width of the laser line changes depending on the distance.

Attaching using the holder (see figure A)
Using the holder (16), you can attach the measuring tool to various objects up to 10 to 60 mm thick, e.g. to vertical or horizontal boards or pipes. Loosen the fastening screw (15) of the holder, position the holder in the desired location and retighten the fastening screw. Place the measuring tool with the tripod mount (6) on the 1/4″ screw (13) of the holder and tighten it to secure it on the holder by applying moderate force. Do not tighten the measuring tool firmly as this could cause damage. Roughly align the holder before switching on the measuring tool. To do this, loosen the locking screw (14) of the holder and move the measuring tool into a horizontal position at the desired height. Retighten the locking screw. You can also mount the measuring tool on the holder using the adapter plate (3).
Working with the Tripod (Accessory)
A tripod offers a stable, height-adjustable support surface for measuring. Place the measuring tool with the 1/4″ tripod mount (6) on the thread of the tripod (11) or a conventional camera tripod. Tighten the measuring tool using the locking screw of the tripod. Roughly align the tripod before switching on the measuring tool.
You can also mount the measuring tool on the tripod using the adapter plate (3).
Working with the adapter plate (see figures B–C)
The adapter plate (3) makes it easier to accurately align the measuring tool with a reference point and enables you to quickly attach and detach the measuring tool.
The adapter plate (3)  can be mounted on the holder (16) or tripod (11).
– Holder: Place the adapter plate with the 1/4″ mount (1) on the screw (13) of the holder and tighten it to secure it on the holder by applying moderate force.
Note: Loosen the locking screw (14) of the holder if you want to change the position of the measuring tool. If the adapter plate is turned without loosening the locking
screw, the adapter plate can become loose and the measuring tool can fall off.
– Tripod: Tighten the locking screw of the tripod in the 1/4″ mount (1) of the adapter plate.
Press the measuring tool into the adapter plate (3) so that the locking mechanisms of the adapter plate engage in the holes on two sides of the measuring tool. The adapter plate
can be fastened to the bottom, back and top side of the measuring tool. Check that the measuring tool is firmly secured.
When the adapter plate is mounted on the back, the height of the measuring tool can be aligned. When it is mounted on the top or bottom, the measuring tool can be aligned
sideways. Turn the fine adjustment screw (2) of the adapter plate to align the laser line with a reference point.
Laser Viewing Glasses (Accessory)
The laser viewing glasses filter out ambient light. This makes the light of the laser appear brighter to the eye.

  • Do not use the laser goggles as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colors.

Maintenance and Servicing

Maintenance and Cleaning
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.
The areas around the outlet aperture of the laser, in particular, should be cleaned on a regular basis. Make sure to check for lint when doing this.
After-sales service and advice on using products
Our after-sales service can answer questions concerning product maintenance and repair, as well as spare parts. You can find exploded drawings and information on spare parts at: www.bosch-pt.com The Bosch product use advice team will be happy to help you with any questions about our products and their accessories. In all correspondence and spare parts orders, please always include the 10‑digit article number given on the type plate of the product.

Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail:
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169 Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Republic of South Africa
Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre
Johannesburg
Tel.: (011) 4939375
Fax: (011) 4930126
E-mail:
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169 Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
KZN – BSC Service Centre
Unit E, Almar Centre
143 Crompton Street
Pinetown
Tel.: (031) 7012120
Fax: (031) 7012446
E-mail:

Disposal
Measuring tools, accessories and packaging should be recycled in an environmentally friendly manner.
Do not dispose of measuring tools or batteries with household waste.
Only for EU countries:
According to the Directive 2012/19/EU, measuring tools that are no longer usable, and according to the Directive 2006/66/EC, defective or used battery packs/batteries, must
be collected separately and disposed of in an environmentally correct manner.

Western Cape – BSC Service Centre
Democracy Way, Prosperity Park
Milnerton
Tel.: (021) 5512577
Fax: (021) 5513223
E-mail:
Bosch Headquarters
Midrand, Gauteng
Tel.: (011) 6519600
Fax: (011) 6519880
E-mail:

Robert Bosch Power Tools GmbH
70538 Stuttgart
GERMANY
www.bosch-pt.com
1 609 92A 4RH (2018.11) T / 259