Electrolux ELFE7637BT Front Load Dryer Instruction Manual

Electrolux ELFE7637BT Front Load Dryer

Installation

WARNING – RISK OF FIRE

Read all the following instructions before installing and using this appliance.

  • Ensure the entire dryer exhaust system is clean and free of lint and debris prior to the installation of your new dryer. The entire exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. Failure to comply with cleaning your exhaust system will increase the RISK of FIRE.
  • DO NOT install a clothes dryer with flexible plastic or flexible foil venting material. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
  • DO NOT screen the exhaust ends of the vent system, or use any screws, rivets or other fasteners that extend into the duct to assemble the exhaust system. NO screen or grate of any mesh size is allowed to cover the outdoor exhaust opening.
  • Install the clothes dryer according to the manufacturer’s instructions and local codes.
  • Clothes dryer installation and service must be performed by a qualified installer, service agency or gas supplier.
  • The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian Electrical Code CSA C22.1 part 1.
  • The gas service to the dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, or in Canada, the Natural Gas and Propane Installation Code, CSA B149.1. An individual manual shutoff valve must be installed within 6 ft. (1.83 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
  • DO NOT stack a dryer on top of a washer already installed on a pedestal. DO NOT stack the washer on top of the dryer. DO NOT stack the washer on top of another washer.
  • The dryer is designed under ANSI Z21.5.1/CSA 7.1 or UL 2158 – CAN/CSA C22.2 No. 112 (latest editions) for HOME USE only.
  • This dryer is not recommended for commercial applications such as restaurants, beauty salons, etc.
  • Destroy the carton and plastic bags after the dryer is unpacked. Children might use them to play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation.
  • Place all materials in a garbage container or make materials inaccessible to children.
  • To reduce the risk of severe injury or death, follow all installation instructions in this manual.

The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and maintaining any appliance.

Connect or Construct Vent Exhaust

The exhaust system must be vented outside with an approved vent hood.

  • Use only 4-inch rigid or semi-rigid metal ducting.
  • Clean lint from the duct system.
  • Use only metal foil tape to connect ducts (no screws).
  • Use 4″ (10.2 cm) clamp to connect dryer & exhaust system.
  • Use a 90° quick-turn elbow to vent left or right from the dryer.

NO screen or grate of any mesh size is allowed to cover the exhaust opening.

NOTE

Never exceed more than 4 – 90˚ elbows in the exhaust duct system.

MAX Number of 90° turns MAXIMUM LENGTH*

of 4” (10.2 cm) Rigid Metal Duct

VENT HOOD-TYPE
(Preferred)
 

4” (10.2 cm)

 

louvered

 

2.5” (6.35 cm)

0 125 ft. (38 m) 110 ft. (33.5 m)
1 115 ft. (35 m) 100 ft. (30.5 m)
2 105 ft. (32 m) 90 ft. (27.5 m)
3 95 ft. (29 m) 80 ft. (24.5 m)
4 85 ft. (26 m) 70 ft. (21.5 m)
  • DO NOT exceed 8 ft. (2.4m) total duct length if installing semi-rigid venting.
  • DO NOT install flexible plastic or flexible foil ducting material.
  • DO NOT use screws, rivets or other fasteners that extend into the duct to assemble the exhaust system.

For detailed information, refer to “Exhaust system requirements” and”Clearance requirements” in the Installation sections of the Use & Care Guide provided with this dryer.

Connect Water Line (Steam Dryer Only)

If this is not a steam dryer, skip to section 3

  1. Inspect all hoses for rubber washers prior to use.
  2. Run water from the cold outlet to clear contaminants.
  3. Connect the dryer Assembly Hose Kit hose extensions from the cold supply to the “Y” connector, then from the “Y” connector to the water inlet on the dryer.
  4. Attach the washer cold water supply line to the“Y” connector.
  5. Tighten all connections by hand, then tighten an additional 2/3 turn with pliers.
  6. Turn on the water and check for leaks.

 

  • Assembly Hose Kit P/N 5304495002 is not included with the purchase of the steam model and MUST be purchased separately.

For detailed information, refer to “Water connection (Steam Model only)” in the Installation sections of the Use & Care Guide provided with this dryer.

Connect to Gas or Electric

Gas Dryer

  1. Apply approved thread sealant.
  2. Wrench-tighten gas line.
  3. Open gas valve and check for leaks with soapy water.
  • For detailed information, refer to “Gas supply requirements” and “Gas connection” in the Installation sections of the Use & Care Guide provided with this dryer.

Electric Dryer

  • For detailed information, refer to “Electrical system requirements” and “Electrical installation” in the Installation sections of the Use & Care Guide provided with this dryer.

WARNING

  • Dryer must be properly grounded at all times.

DANGER

  • If using LP (Liquid Propane) STOP and install the LP kit before operating your gas dryer.

Installation Checklist

Exhaust Venting

  • Free-flowing, clear of lint buildup
  • 4 inch (102 mm) rigid metal or semi-rigid metal transition ducting of minimal length and turns
  • NO foil or plastic venting material
  • Approved vent hood exhausted to outdoors

Leveling

  • The dryer is level, side-to-side and front-to-back.
  • The cabinet is sitting solidly on all corners.

Gas Supply (Gas Dryer)

  • Manual shutoff valve present in the supply
  • All connections sealed with the approved sealer and wrench tight
  • Conversion kit for LP GAS system
  • The gas supply turned on
  • No leaks present at all connections – check with soapy water, NEVER check with flame

Water Hookup (Select Models)

  • Inspect hoses for proper placement of rubber washers
  • The water supply is turned on
  • Check for leaks
  • Steam model dryers require the use of assembly HOSE KIT #5304495002(not included) and must be purchased separately

240v Electric Supply (Electric Dryer)

  • Approved NEMA 10-30 or 14-30 service cord with all screws tight on the terminal block
  • Approved strain relief installed
  • Terminal access cover installed before initial operation

Door Reversal

  • Follow detailed instructions in this guide
  • Test hinge and latch for function

Electrical Power

  • House power turned on
  • Dryer plugged in

Final Checks

  • Door latches and drum tumbles when cycle starts
  • Registration card sent in