First off

Congratulations on your purchase of Acer Air Monitor Pro. It is a first, positive step in helping you improve the air you breathe and your quality of life. This simple device monitors the air quality within its immediate surroundings.

The Air Monitor Pro allows you to monitor critical indicators of indoor air quality.

These are:

  • The Air Monitor allows you to monitor six critical indicators of indoor air quality. These are:
  • Temperature – This metric directly relates to comfort and mood.
  • Humidity – Moisture leads to colds, flus, and risk of toxic mold formations.
  • VOCs – Volatile Organic Compounds are toxic chemicals that can cause skin and respiratory irritation.
  • Particulates – PM2.5/PM10 (fine/coarse particulate matter) travels deep into our respiratory system and can trigger asthma, allergies and other related health problems.
  • CO2 – Carbon dioxide content in the fresh air is typically measured around 400 PPM (Parts Per Million), depending on the location. People in a high CO2 environment will feel drowsy, dizzy, have headaches, and experience hearing and visual dysfunction. It may also cause unresponsiveness and decision delay.
  • Formaldehyde – One of volatile organic matter indoor. From the toxicology research, it has been confirmed as carcinogenic substances. Formaldehyde can stimulate human skin, respiratory tract, central nervous system and cause other unhealthy effects.
  • CO – Carbon monoxide is toxicity to human body. People in a high CO environment will feel dizziness, headache, dyspnea and may cause other poisoning phenomenon.
  • O3 – Oxygen is an irritant gas. It can stimulate the eyes and respiratory tract, and may cause cough, chest discomfort and other symptoms.

Air Monitor Pro AMP220 series are configurable. You can choice sensor and wireless configuration for your environmental applications. To verify your Air Monitor model, please check the label located on the back of the Air Monitor. The user manual is based on the latest Air Monitor firmware and App version; please follow the user manual to operate it.

Through visual indicators on the device, as well as more detailed information on the app, the Acer Air Monitor helps track and gives advice on how to improve the air quality, your health, and the health of the ones you care about.

Package contents

Make sure the following items are in your package. If anything is missing, contact your authorized dealer or distributor.

  • Air Monitor Pro
  • USB Cable
  • USB Power Adapter
  • Desktop Holder
  • Quick Guide
  • Warranty Card

Note: Actual items might differ from illustrations.

A tour of the device

Product Appearance 

  Item Description
1 Breathing LED light Lights up using different colors to show the current air quality.
2 Display Show the air quality index and individual concentrations.
3 Light Sensor Measure the ambient illumination.
4 Function button Tune On/Off the Breathing LED light. When the LED light is off, the display will display indoor air quality index only.
5 Wi-Fi Green LED   Wi-Fi Status Red LED Green LED   /
Booting Flash Off /
Wait for setup On Off /
6 Wi-Fi Red LED /
Connecting to

access point

Off Slow Flash /
Connected to

access point

Off Fast Flash /
Connected to cloud Off On /
Resetting Flash Flash /
7 Wi-Fi Reset Button To reset Wi-Fi configuration, please use an unfolded paperclip to press and hold this button

until the Wi-Fi Red LED lights up.

/
8 Communication Ports Communication and I/O Ports:
  1. NO2: Dry contact 2
  2. NO1: Dry contact 2
  3. A+: RS485 A+
  4. B-: RS485 B-
  5. GND: Ground
  6. VCC +5V: +5V output
/
9 Micro-USB Connect to power adapter /
Air Monitor Pro Display

The display by default show the value detected by each sensor sequentially. When you press the function button, you can fix it on the Indoor Air Quality index (IAQ) screen. When you press it, you can switch back to the carousel mode.

  Item Description
1 Sensor Name (Note: Air Monitor Pro has different configuration of sensors. Please check your

product configuration.)

IAQ: Indoor Air Quality Temp: Celsius

Humi.: Relative Humidity

PM2.5: Particular Matter size < 2.5 µm PM10: Particular Matter size < 10 µm TVOC: Volatile Organic Compound CO2: Carbon Dioxide

CO: Carbon Monoxide HCHO: Formaldehyde Ozone: O3

Illum.: Environment illumination

2 Real-time Measurement The latest measurement of sensor.
3 Version Air Quality and sensor version.
4 Wireless Status Show the exists of Wi-Fi and Bluetooth hardware
5 Unit The unit corresponding sensor
6 Warming Up If it shows a blue point, it means the

corresponding sensor is warming up.

7 Counter Counting timer in second from booting.

Getting started

Install on a desktop holder

  1. Attach the appropriate power adapter plug to the USB power adapter.
  2. Gently insert and secure Air Monitor Pro along the two inner grain of the desktop holder.
Install onto a wall mount holder

Note:Wall mount holder is optional.

  1. There are two outlet holes on the wall mount holder. You may remove the piece of plastic (A) to open the hole accordingly.
  2. The wall mount can be fixed to the wall. You may use attached screws to fix it.
  3. Connect USB cable and Air Monitor Pro
  4. Place Air Monitor Pro into the holder and secure it by Screw (B)
  5. Plug to the USB power adapter

Note

  • The breathing LED light will first cycle through the different colors and begin gathering data.
  • To get the most accurate data, please always place the Air Monitor such as the function key is facing upwards
  • Do not cover the light sensor or place the device in the shade in order to ensure the best experience.
Download the Air Monitor Pro app from either the iOS App Store or the Google Play store.

Note: Mobile system requirements:

Android : Android 5.0 and above
iOS : iOS 10.0 and above

Using Air Monitor Pro APP 

Scan Bluetooth air quality broadcast 

You can directly scan and read the immediate value without logging in to the account.

If you have logged in to your account, you can go through the menu.

Setup Wi-Fi connection 

Please press Add icon in the upper right corner of the main page to set up Wi Fi connection. It will guide you step by step to setup Air Monitor Pro for remote monitoring.

  1. Please use an unfolded paperclip to press and hold the Wi-Fi Reset button until the Wi-Fi Red LED lights up. Your Air Monitor Pro will show an temporary Wi-Fi access point named AcerAMP-XXXX, where XXXX are 4 English alphabet or number.
  2. Go to your phone’s Wi-Fi Settings, and connect it to AcerAMP-XXXX signal.
  3. Switch back to Air Monitor Pro setting page. Select an SSID of Wi-Fi access point that allows your Air Monitor Pro to connect to the Internet.
  4. After completing the Wi-Fi setup process, you can update the name of Air Monitor Pro.
Device List 

This page lists Air Monitor Pro, which has been set up for your account, and displays summary information.

  Item Description
1 Indoor Air Quality (IAQ)

Index

IAQ index is calculated from PM2.5, PM10, TVOC,

and CO2 values.

2 Device Name The Name of Air Monitor Pro that user can define

it.

3 Air Quality Description The description is generated according to the IAQ.
4 Update Time Show the latest update time of sensor

measurements.

5 Connection Status Green: Connected

Grey: Disconnected

6 Menu List all functions supported by this APP.
7 Add Device Add device with current account.
Individual Air Monitor Pro Page 

Display the details of individual Air Monitor Pro.

  Item Description
1 Device Name Name of the Air Monitor Pro
2 Indoor Air Quality (IAQ) Light Green: 0-50

Yellow: 51-100

Orange: 101-150

Red: 151-200

Purple: >200

3 Indoor Air Quality (IAQ)

Index

The Indoor Air Quality Index calculated from

PM2.5, PM10, TVOC, and CO2 values.

4 IAQ description Description of current indoor air quality
5 Sensor

(Note 1: Air Monitor Pro has different sensor configurations.)

(Note 2: Grey color means the sensor is warming up.)

Illumination: Ambient environmental brightness Temp: Temperature

HUMI.: Relative Humidity

TVOC: Total Volatile Organic Compounds PM2.5: Particulate Matter with size less than 2.5 µm

PM10: Particulate Matter with size less than 10 µm CO2: Carbon Dioxide

CO: Carbon Monoxide Ozone: O3

HCHO: Formaldehyde

6 Update Time Latest update time of sensor value
7 Knowledge Center Tutorial of Indoor Air Quality Pollutants
8 Sensor Value User select a sensor item and show the current

value here and chart below.

9 Sensor History Chart The history data of individual sensor selected by

user.

10 Return Back to the device list page
11 Device Settings Press this icon can switch to the setting page of

this Air Monitor Pro

Using Map 

The MAP page can show the location of your Air Monitor Pro. The location of Air Monitor Pro is set by user. Please switch to the device settings page to set up the location.

Press the Menu and select “Map View” to show the map.

Understanding the breathing LED light 

The breathing LED light lights up to show the current air quality using specific defined colors for each air quality level.

Refer to the table below for a quick description of these lights:

Color IAQ Readings Description
Green 0 – 50 Good
Yellow 51 – 100 Moderate
Orange 101 – 150 Unhealthy for sensitive group
Red 151 – 200 Unhealthy
Purple >200 Very Unhealthy

Note: You can press function button to turn on/off the breathing LED light.

General safety information 

  • Never inject gases, pollutants, or blow smoke/fumes directly towards the device. Exposure to an excess of pollutants may permanently damage the sensors.
  • Never use the Air Monitor Pro…
    • Under conditions of extreme temperature or humidity
    • Outdoors
    • Near potted plants
    • In a dusty environment, such as a building with ongoing renovations
    • Close to silicone-based glue or any product releasing silicone fumes
  • Never place the Air Monitor Pro…
    • Near heat or flames
    • In/under/next to liquids
    • With anything on top of it or covering it – Inside a closet or drawer Misuse can cause burns, fire, electrocution, and other hazards.
  • Never clean the Air Monitor Pro with the following:
    • Water or spray
    • A feather duster
    • A vacuum cleaner
  • Do not open the device or make modifications to it as it will void the warranty.
  • Do not use the device if it has any damage or isn’t working properly.
  • Do not plug/unplug the device frequently.
  • Use only accredited accessories.
  • Unplug the device when unused for long periods of time.
  • Do not block any ventilation openings.

Taking care of your device 

Please check the ventilating holes of the device every six months. If there is any dirt, please use a brush to gently remove the dust and keep the vents clear.

Frequently Asked Questions(FAQs) 

For frequently asked questions, please refer to our website (http://home.cloud.acer.com/tw/airmonitor/#qaa)。

Specifications

Power
  • Voltage range/frequency: 100~240V AC, 50/60 Hz
  • DC Output: 5V / 2A
Connectivity
  • Bluetooth 4.2LE
  • Wireless LAN 802.11 b/g/n 2.4GHz
  • This radio equipment operates with the following frequency bands and maximum radio-frequency power:
    • Bluetooth: <20dBm
    • 802.11bgn: <20dBm
  • RS-485
    Baud rate: 9600 bps 8-n-1
    Protocol: MODBUS RTU
Sensors (Note: according to configuration of Air Monitor Pro)
Sensor Specification Detection Method
Temperature Unit: OC; Range: 0 – 80;

Resolution: 0.1; Accuracy: ±1.0

Semiconductor
Relative

Humidity

Unit:%; Range: 0 – 100;

Resolution: 0.1; Accuracy: ±5.0

Semiconductor
TVOC Unit: PPM; Range: 0.02 – 10.00 ;

Resolution: 0.001; Accuracy: Relative Accurate

Semiconductor
CO2 Unit: PPM; Range: 0 – 10,000;

Resolution: 1; Accuracy: ±70

NDIR (Nondispersive infrared sensor)
CO Unit: PPM; Range: 0 – 500;

Resolution: 1; Accuracy: ±20 or ±5%

Electrochemical
Formaldehyde Unit: PPM; Range: 0 – 1.60;

Resolution: 0.01; Accuracy: Relative Accurate

Electrochemical
PM2.5 Unit: μg/m3; Range: 0 – 1,000;

Resolution: 1;

Accuracy: ±15% (>100) or ±15 (<100)

Laser light scattering
PM10 Unit: μg/m3; Range: 0 – 1,000;

Resolution: 1; Accuracy: Relative Accurate

Laser light scattering
Ozone Unit: PPM; Range: 0.2 – 10.00;

Resolution: 0.01; Accuracy: Relative Accurate

Electrochemical
Illumination Unit: Lux; Range: 0 – 10,000;

Resolution: 1; Accuracy: Relative Accurate

Semiconductor
Operating Temperature 
  • 0°C~45°C

FCC Warning Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

The antenna(s) used for this transmitter must not be co-located of operating in conjunction with any other antenna or transmitter.
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. Ln order to avoid the possibility of exceeding the Fcc radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8inches) during normal operation.