Bosch GAS 15 Wet or Dry Extractor Instruction Manual

BOSCH GAS 15 Wet or Dry Extractor

 

 

SAFETY INSTRUCTION

  • This vacuum cleaner is not intended for use by children and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge. Otherwise, there is a danger of operating errors and injuries.
  • Supervise children. This will ensure that children do not play with the vacuum cleaner.
  • Do not vacuum materials that are harmful to one’s health, e. g. dust from beech or oak wood, masonry dust, asbestos. These materials are considered carcinogenic.
  • Inform yourself about the valid regulations/laws for your country concerning the handling of materials that are hazardous to one’s health.
  • Use the vacuum cleaner only after having received sufficient information on its usage. A thorough introduction reduces operating errors and injuries.
  • The vacuum cleaner is suitable for vacuuming dry materials and, by taking suitable measures, also for vacuuming liquids. The penetration of liquids increases the risk of an electric shock.
  •  Do not vacuum inflammable or explosive fluids; for example, benzene, oil, alcohol, solvents. Do not vacuum hot or burning dust. Do not operate the machine in rooms where the danger of an explosion exists. The dusts, vapours or fluids can ignite or explode.
  • Use the socket only for the purposes specified in the operating instructions.
  • Switch the vacuum cleaner off immediately as soon as foam or water comes out, and empty the container. Otherwise, the vacuum cleaner can become damaged.
  • Keep the vacuum cleaner away from rain or moisture. The penetration of water into the vacuum cleaner lid increases the risk of an electric shock.
  • The vacuum cleaner may only be stored indoors.
  • Clean the float at regular intervals, and check it for damage. Otherwise, its function can be impaired.
  •  When operating the vacuum cleaner in damp environments, use a residual current device (RCD). Using a residual current device (RCD) reduces the risk of an electric shock.
  •  Connect the vacuum cleaner to a properly earthed mains supply. The socket outlet and the extension cable must have an operative protective conductor.
  •  Before each use, check the vacuum cleaner, cable and plug. Do not use the vacuum cleaner when defects are detected. Do not open the vacuum cleaner yourself and have it repaired only by qualified personnel using original spare parts. Damaged vacuum cleaner, cables and plugs increase the risk of an electric shock.
  •  Do not drive over, crush or stretch the cable. Do not pull the cable to unplug the plug from the socket outlet or to move the vacuum cleaner. Damaged cables increase the risk of an electric shock.
  •  Before maintaining or cleaning the vacuum cleaner, making any adjustments, changing accessories or placing the vacuum cleaner aside, remove the plug from the socket outlet. This safety measure prevents accidental starting of the vacuum cleaner.
  •  Provide for good ventilation at the working place.
  •  Have the vacuum cleaner repaired only through qualified specialists and only using original spare parts. This ensures that the safety of your vacuum cleaner is maintained.
  •  Before restarting, check the proper condition of the vacuum hose. When doing this, leave the vacuum hose mounted to the vacuum cleaner to prevent dust from coming out. Otherwise, you could possibly inhale dust.
  •  Do not use the vacuum cleaner as a seat. The vacuum cleaner could become damaged.
  •  Use the mains cable and the vacuum hose carefully. Other persons could be harmed.
  •  Do not clean the vacuum cleaner with a water jet pointed directly at it. The penetration of water into the vacuum cleaner lid increases the risk of an electric shock.

Symbols

The following symbols could have a meaning for the use of your vacuum cleaner. Please take note of the symbols and their meaning. The correct interpretation of the symbols will help you to use the vacuum cleaner in a better and safer manner.

Symbols and their meaning

  • Read all safety warnings and all instructions.
  • Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
  • Do not hang the vacuum cleaner, e. g. for transport purposes, to a crane hook. The vacuum cleaner is not suitable for handling by crane. Danger of injury and causing damage.
  •  Do not use the vacuum cleaner as a seat, ladder or stepladder. The vacuum cleaner can tip over and become damaged.
    Danger of injury.

Symbols and their meaning (GAS 15)

Symbols and their meaning (GAS 15 PS)

  • Automatic Start/Stop feature
    • Extraction of dust resulting from running power tools The vacuum cleaner automatically switches on and off with a time delay
  • Switching Off
  • Vacuuming
    • Vacuuming of deposited dust

Product Description and Specifications

Intended Use

The vacuum cleaner is intended for collecting, vacuuming, conveying and separating non-flammable dry dusts, nonflammable liquids and a water-air mixture. It is suitable for the increased demands in professional use, e.g. in trade, industry and workshops. Use the vacuum cleaner only when you fully understand and can perform all functions without limitation, or have received appropriate instructions.

Product Features

The numbering of the product features refers to the illustration of the vacuum cleaner on the graphics page.

  1.  Container
  2.  Hose connection piece (vacuuming function)
  3.  Socket for power tool(GAS 15 PS)
  4.  Mode selector switch(GAS 15 PS)
  5.  On/Off switch(GAS 15)
  6.  Carrying handle
  7.  SFC switch
  8.  Vacuum lid
  9.  Latch of the vacuum cover
  10.  Castor
  11.  Vacuum-hose holder
  12.  Holder for vacuum tubes
  13.  Hose connection piece (blower function)
  14.  Castor brake
  15.  Tool sleeve(GAS 15 PS)
  16.  Retaining strap of the vacuum hose
  17.  Vacuum hose
  18.  Elbow
  19.  Plastic bag/Dust bag*
  20.  Filter
  21.  Wet filter
  22.  Crevice nozzle
  23.  Rubber lip
  24.  Brush insert
  25.  Floor nozzle
  26.  Vacuum tube
  27.  Snap-fastener
  28.  Clips for securing the plastic bag
  29.  Filter holder
  30.  Filter basket
  31.  Air diffuser

Technical Data

Automatic Start/Stop feature

Noise/Vibration Information
Sound emission values determined according to Typically the A-weighted sound pressure level of the vacuum cleaner is 74 dB(A). Uncertainty K=3 dB. The noise level when working can exceed 80 dB(A).
Wear hearing protection!
Vibration total values ah (triax vector sum) and uncertainty K determined according to EN 60335-2-69:

Assembly

Before any work on the vacuum cleaner itself, pull the  mains plug.

Mounting VAC Accessories 

  • The vacuum hose 17 is equipped with a clip system, with which the VAC accessories (tool sleeve 14, elbow 17) can be connected.
  • Mounting the Tool Sleeve (GAS 15 PS)
  •  Mount the tool sleeve 15 onto the vacuum hose 17 until both snap-fasteners 27 of the vacuum hose can be heard to engage.
  •  To disassemble, press both snap-fasteners 27 inward and pull the components apart.

Mounting Nozzles and Tubes

  •  Mount the elbow 18 onto the vacuum hose 17 until both snap-fasteners 27 of the vacuum hose can be heard to engage.
  •  Afterwards, mount the desired VAC accessory (floor nozzle, crevice nozzle, vacuum tube, etc.) firmly onto the elbow 18.
  •  To disassemble, press both snap-fasteners 27 inward and pull the components apart.

Mounting the Vacuum Hose

Vacuuming function 

  •  Insert the vacuum hose 17 into the hose connection piece 2 and turn it all the way in clockwise direction.
  • Note: While vacuuming, an electrostatic charge develops in the vacuum hose and accessories caused by the friction of the dust, which the operator could experience in the form of static discharging (dependent on environmental influences and physical perception). As a general rule, Bosch recommends using an anti-static vacuum hose (accessory) when vacuuming fine dusts and dry materials.

Blower Function

  •  The vacuum cleaner has a blower function. Do not blow the outgoing air randomly in enclosed areas. Use the blower function only with the a clean hose. Dusts can be hazardous to one’s health.
  •  Switch on the vacuum cleaner for at least 5 seconds (GAS 15: On/Off switch 5 to “On”; GAS 15 PS: Mode selector switch 4 to the “Vacuuming” symbol) to clean the vacuum hose 17 of dust deposits.
  •  Turn the vacuum hose 17 all the way in anti-clockwise direction and pull it out of the hose connection piece 2.
  •  Insert the vacuum hose 17 into the hose connection piece 13 and turn it all the way in clockwise direction. Inserting/Removing the Plastic Bag or Dust Bag

(Dry Vacuuming) 

For dry vacuuming, you can insert a plastic bag 19 or a dust bag (accessory) into the vacuum cleaner. This makes the dust easier to dispose of.


Inserting the Plastic Bag

  •  Unlock the latches 9 and remove the vacuum lid 8.
  •  Insert the plastic bag 19 into the container 1 with the intake hole facing forward. Secure the plastic bag under the suction hole using the clips 28.
  •  Ensure that the plastic bag 19 is completely up against the inner walls of the container 1.
  •  Fold the rest of the plastic bag 19 over the rim of the container
  •  Reattach the vacuum lid 8 again and lock the latches 9.

Removing and Sealing the Plastic Bag

  •  Unlock the latches 9 and remove the vacuum lid 8.
  •  Pull the edge of the full plastic bag 19 backwards out of the clips 28.
  •  Carefully take the plastic bag 19 out of the vacuum cleaner without damaging it.
  • When doing so, make sure that the plastic bag does not scrape against the suction hole or other sharp objects.
  • Replacing/Inserting the Dust Bag (Accessory)
  •  Unlock the latches 9 and remove the vacuum lid 8.
  •  Pull off the full dust bag 18 from the connection flange toward the rear. Close the opening of the dust bag by folding down the lid. Remove the closed dust bag from the vacuum cleaner.
  •  Work the new dust bag over the connection flange of the vacuum cleaner. Make sure that the dust bag faces completely against the interior sides of the container 1 over its full length.
  •  Reattach the vacuum lid 8 again and lock the latches 9.

Inserting the Rubber Lip (Wet Vacuuming)

  •  Carefully pry the brush inserts 24 out of the floor nozzle 25 using a suitable tool.
  •  Insert the rubber lips 23 into the floor nozzle 25.
  • Note: The structured side of the rubber lips must face outward.

Inserting the Wet Filter (Wet Vacuuming) 

  •  Unlock the latches 9 and remove the vacuum lid 8.
  •  Turn the filter holder 29 all the way in direction of rotation “ ” and take the filter holder together with the filter 20 out of the container 1.
  •  Put the wet filter 21 over the filter basket 30.
  •  Reattach the vacuum lid 8 again and lock the latches 9.

Operation

Starting Operation

  •  Observe the mains voltage! The voltage of the power source must correspond with the data on the type plate of the vacuum cleaner.
  • Please inform yourself about the valid regulations/ laws for your country concerning the handling of materials that are hazardous to one’s health. The vacuum cleaner may generally not be used in rooms where the danger of an explosion exists.
  • To save energy, only switch the vacuum cleaner on when using it.
  • To ensure optimal vacuuming performance, always completely unwind the vacuum hose 17 from the vacuum cleaner lid 8.

Dry Vacuuming

  • Vacuuming of deposited dust GAS 15:
  •  To switch on the vacuum cleaner, set the On/Off switch 5 to “On”.
  •  To switch off the vacuum cleaner, set the On/Off switch 5 to “Off”.
    GAS 15 PS:
  •  To switch on the vacuum cleaner, set the mode selector switch 4 to the “Vacuuming” symbol.
  •  To switch off the vacuum cleaner, set the mode selector switch 4 to the “Switching Off” symbol.

Extraction of dust resulting from running power tools (only for GAS 15 PS) 

  •  An adequate ventilation rate (L) must be provided for when the outgoing air is circulated. Observe the respective national regulations.
  • A socket outlet with earthing contact 3 is integrated in the vacuum cleaner. An external power tool can be connected there. Observe the maximal allowable load of the connected power tool.
  •  Mount the tool sleeve 15 (see “Mounting the Tool Sleeve”, page 17).
  •  Insert the tool sleeve 14 into the dust extraction outlet for the power tool.
  • Note: When working with power tools that have a low air feed into the vacuum hose (e.g. jigsaws, sanders, etc.), the air diffuser 31 of the tool sleeve 15 must be opened. Only then can the semi-automatic filter cleaning (SFC) work without any problems.
  • To do so, turn the ring above the air diffuser 31 until a maximum opening is produced.
  •  To activate the automatic start/stop of the vacuum cleaner, set the mode selector switch 4 to the “Automatic Start/Stop” symbol.
  •  To start the operation of the vac, switch on the power tool connected to the socket 3. The vacuum cleaner starts automatically.
  •  Switch the power tool off to end the vacuuming. The delayed action shutdown of the Automatic Start/Stop continues to run for up to 6 seconds in order to extract residual dust from the vacuum hose.
  •  To switch off the vacuum cleaner, set the mode selector switch 4 to the “Switching Off” symbol.

Wet Vacuuming

  •  Do not vacuum inflammable or explosive fluids; for example, benzene, oil, alcohol, solvents. Do not vacuum hot or burning dust. Do not operate the machine in rooms where the danger of an explosion exists. The dusts, vapours or fluids can ignite or explode.
  •  The vacuum cleaner may not be used as a water pump. The vacuum cleaner is intended for vacuuming air and water mixtures.
  •  Before any work on the vacuum cleaner itself, pull the mains plug.
  •  Before wet vacuuming, remove the plastic bag 19 or the dust bag and empty the container 1.
  • Note: Use the wet filter 21, which separates the liquid from the solids, to make disposal easier when vacuuming watersolid mixtures.
  •  Insert the wet filter into the container (see “Inserting the Wet Filter”, page 17).
  •  Mount the rubber lips into the floor nozzle (see “Inserting the Rubber Lip”, page 17).
  • The vacuum cleaner is equipped with a float. Vacuuming is stopped when the maximum filling level is reached.
  •  Set the mode selector switch 4 to the “Switching Off” symbol (GAS 15 PS) or set the On/Off switch 5 to “Off” (GAS 15).
  •  Empty the container 1.
  • To prevent the formation of mould after wet vacuuming:
  •  Remove the vacuum lid 8 and leave it to dry thoroughly.
  •  Remove the wet filter 21 and also leave this to dry thoroughly.

Semi-Automatic Filter Cleaning 

  • The filter cleaning system must be actuated at the latest when the vacuuming performance is no longer sufficient.
  • The filter cleaning frequency depends on the type and amount of dust. With regular usage, the maximum vacuuming performance is maintained longer.
  • During semi-automatic filter cleaning (SFC), the air flow is reversed to clean deposited dust from the flaps of the filter.
  • Triggering the SFC Filter Cleaning
  •  Shut or block off the nozzle or vacuum-hose opening with your palm.
  •  Press the SFC switch 7 three times.

Maintenance and Service

Maintenance and Cleaning

  •  Before any work on the vacuum cleaner itself, pull the mains plug.
  •  For safe and proper working, always keep the vacuum cleaner and ventilation slots clean.
  •  Wear a dust protection mask when maintaining and cleaning the vacuum cleaner.
  • If the replacement of the supply cord is necessary, this has to be done by Bosch or an authorized Bosch service agent in order to avoid a safety hazard.

Removing/Changing the Filter 
Replace a damaged pleated filter immediately.

  •  Unlock the latches 9 and remove the vacuum lid 8.
  •  Turn the filter holder 29 all the way in direction of rotation “ ” and take the filter holder together with the filter 20 out of the container 1.
  •  Pull the dirty/damaged filter 20 off the filter holder 29.
  •  Brush down the flaps of the filter with a soft brush. or Replace a damaged filter.
  •  Attach the filter holder 29 to the cleaned/new filter 20.
  •  Put the filter holder 29 together with the filter 20 over the filter basket 30 and turn the filter holder 29 all the way in direction of rotation “ ”.
  •  Reattach the vacuum lid 8 again and lock the latches 9.

Container

Wipe out the container 1 from time to time with a commercially available, non-scouring cleaning agent and allow to dry.

Storage and Transport (see figure I)

  •  Wrap the power cable around the carrying handle 6.
  •  Insert the vacuum tubes 26 into the holders 12.
  •  Put the vacuum hose 17 around the vacuum lid and hang the retaining strap 16 on the holder 11.
  •  Carry the vacuum cleaner only by the carrying handle 6.
  •  Store the vacuum cleaner in a dry room and secure it against unauthorised use.
  •  To lock the castors 10, actuate the castor brakes 14 by pushing down.

Correction of Malfunctions

After-sales Service and Application Service

Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. Exploded views and information on spare parts can also be found under: www.bosch-pt.com Bosch’s application service team will gladly answer questions concerning our products and their accessories. In all correspondence and spare parts orders, please always include the 10-digit article number given on the nameplate of the product.

After-sales Service and Application Service

Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. Exploded views and information on spare parts can also be found under: www.bosch-pt.com Bosch’s application service team will gladly answer questions concerning our products and their accessories. In all correspondence and spare parts orders, please always include the 10-digit article number given on the nameplate of the product.