D-Link DBA-3620P Outdoor Access Point User Manual

D-Link DBA-3620P Outdoor Access Point

About This Guide

This installation guide provides basic instructions for installing the DBA-3620P Nuclias Cloud-Managed Wave 2 Outdoor Access Point on your network. For additional information about how to use the Access Point, please see the User Manual, which is available on the D-Link support website.

Before You Begin

This installation guide provides instructions for installing the DBA-3620P on your network. Additional documentation is also available on the D-Link support website.

  • D-Link Nuclias User Manual: For additional information and instructions on how to configure the device using D-Link Nuclias Cloud.

System Requirements

  • Windows®, Macintosh®, or Linux-based operating system
  • Ethernet port or installed Ethernet adapter
  • Internet Explorer 11, Safari 7, Firefox 28, Google Chrome 33 or higher.

Unpacking the Product

Open the shipping carton and carefully unpack its contents. Please consult the packing list below to make sure all items are present and undamaged. If any item is missing or damaged, please contact your local D-Link reseller for a replacement.

  • DBA-3620P Nuclias Cloud-Managed Wave 2 Outdoor Access Point
  • Shielded Cat 5E Ethernet Cable
  • Mounting Ties (Qty. 2)
  • Wall Mount Base
  • Console Cable
  • Grounding Wire

Note: To power the DBA-3620P, please use any D-Link IEEE 802.3at/af-compliant PoE switch or the D-Link DPE-311GI PoE injector.

Optional Accessories

  • PoE Injector (Model: DPE:311GI)
    Note: These accessories are not included in the package. If any of these items are required, please contact your reseller to order it.
    Hardware Overview

LEDs


Figure 1. DBA-3620P LEDs

LED Status Description
Power/ Cloud Solid
Orange
Device is
performing
startup procedure
Blinking
Orange
Device is resetting to its default settings or it is
upgrading its firmware
Solid Green Device is currently in cloud mode
Blinking Green Device is trying to connect to D-Link Nuclias Cloud
Solid Red Device is not working
properly in cloud mode
LAN

(PoE in)

Solid Green Link Present
Blinking Green Sending or receiving data packets
Light Off Link down or
unplugged
WLAN (2.4GHz/5 GHz) Solid Green Device Ready
Blinking Green Sending or receiving packets
Light Off Radio off/ device is undergoing boot process
Interfaces
  • ANT***
  • LAN (PoE)*
  • CONSOLE
  • Toggle switch for internal or external antennas**
  • Reset Button
  • ANT

Figure 2. DBA-3620P Rear Panel

  • DBA-3620P can be powered via PoE from LAN (PoE)
  • A manual reboot is needed when switching from internal to external antennas, and vice versa.
  • (Optional) RP-SMA connectors for external 2.4/5 GHz dual-band antennas.
  •  For external antennas, the toggle switch must be switched to EXT ANT.

Configuring the Access Point

Using D-Link Nuclias

Note: To use D-Link Nuclias, the DBA-3620P must be connected to the Internet.
The DBA-3620P is designed to be managed through D- Link Nuclias Cloud. Refer to the D-Link Nuclias User Manual for detailed configuration instructions.
D- Link Nuclias

Figure 3: Connecting through D-Link Nuclias

  • DBA-3620P
  • Switch or Router Switch or Router
  • Switch or Router
  • Management
  1. On an Internet-connected PC, open a web browser and go to www.nuclias.com.
  2. Enter your D-Link Nuclias user name and password.
Manual Configuration

Note: D-Link recommends manually configuring the device before mounting it.
If you are unable to connect to D-Link Nuclias Cloud, you may need to manually configure the DBA-3620P using its web user interface (UI). Refer to the D-LinkNucliasUser Manual for detailed configuration instructions. Use one of the following methods to access the web user interface:

Connecting through Ethernet

Note: The management PC must be in the same subnet as the DBA-3620P

  1. Use an Ethernet cable to connect the DBA-3620P to the management PC or to the switch or router the management PC is connected to.
  2. Open a web browser and type in the default host name of the DBA-3620P and press Enter. The default host name is DBA-3620P-XXXX where XXXX represents the last 4 characters of the MAC address listed on the device label located on the bottom of the device.
  3. When prompted, enter the default login credentials:
    User name: admin
    Password: admin
Connecting Wirelessly
  1. Connect the management PC to the default SSID of the DBA-3620P. The SSID will be in the format DBA-3620P-XXX where XXXX represents the last 4 characters of the MAC address listed on the device label located on the bottom of the device.
  2. Open a web browser and type in the default host name of the DBA-3620P and press Enter. The default host name is DBA-3620P-XXXX where XXXX represents the last 4 characters of the MAC address listed on the device label located on the bottom of the device.
  3. When prompted, enter the default login credentials:
    User name: admin
    Password: admin
Installation
  • POWER IN
  • POE
  • LEN

  • Computer
  • Connect the Power Cord to the PoE Adapter and a power outlet with earthing connection
  • LAN(POE) on DBA-3620P to Ethernet Port labeled PoE on PoE Adapt
  • Connect Computer to Ethernet Port labeled LAN on PoE Adapter

Configure the access point
To set up and manage the DBA-3620P, use one of the following methods:

  • LAN on DBA-3620P to Ethernet Port labeled POE on PoE Adapter
  • Connect the Power Cord to the PoE Adapter and a power outlet
  • Connect Computer to Ethernet Port labeled LAN on PoE Adapter

  • Manage the access point from the computer:
    Connect the access point and your computer directly via a straight-through Ethernet cable.

  • Manage the access point from the computer via the Switch or Router:
    Connect the access point and your computer to the same switch or router.
Mounting Options

Pole Mount and Wall Mount are the two mounting options for the DBA-3620P.

Cable Requirement
Use a Cat 5 cable with an even sheath. The Ethernet ports on the DBA-3620P access point cannot accept a Cat 5 cable that has an uneven sheath; the RJ-45 connector on the cable will not fit properly into the receptacle on the access point.

Pole Mounting Installation

Installation

  1. Open the bottom panel with a Phillips screwdriver.
  2. Plug one end of Cat 5 cable into the LAN port on the DBA-3620P, and the other end to the port labeled POE on the PoE Adapter
  3. Choose a gasket (6 mm or 4 mm) to fit the Ethernet cable; if CONSOLE is not in-use, please put on the black gasket.
  4. Close the bottom panel with a Phillips screwdriver.
  5. Attach a grounding wire. Instructions for the installation of that conductor to building earth by a SKILLED PERSON.
  6. Attach access point to a pole
  7. Fasten the mounting ties.
Wall Mounting Installation

Installation

  1. Use the supplied screws to attach the Wall Mount Base to the wall.
  2. Attach DBA-3620P to the Wall Mount Base. Thread and fasten the Mounting Ties

Appendix A – Statements

Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

IMPORTANT NOTE:

Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20.5cm between the radiator & your body.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Country Code selection feature to be disabled for products marketed to the US/CANADA

Professional installation instruction
Please be advised that due to the unique function supplied by this product, the device is intended for use with our interactive entertainment software and licensed third-party only. The product will be distributed through controlled distribution channel and installed by trained professional and will not be sold directly to the general public through retail store.

  1. Installation personal
    This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting.
  2. Installation location
    The product shall be installed at a location where the radiating antenna can be kept 20.5cm from nearby person in normal operation condition to meet regulatory RF exposure requirement.
  3. External antenna
    Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC/IC limit and is prohibited.
  4. Installation procedure
    Please refer to user’s manual for the detail.
  5. Warning
    Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty.

Industry Canada statement
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference; and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Caution:

  • The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit; and
  • The maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non point-to-point operation as appropriate.
  • Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.

Advertisement :

Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25cm between the radiator & your body.

Professional installation instruction

  1. Installation personal
    This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting.
  2. Installation location
    The product shall be installed at a location where the radiating antenna can be kept 25cm from nearby person in normal operation condition to meet regulatory RF exposure requirement.
  3. External antenna
    Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of ISED limit and is prohibited.
  4. Installation procedure
    Please refer to user’s manual for the detail. Warning Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty.

CE Mark Warning:
This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

  1. A safety grounding system is necessary to protect your outdoor installation from lightning strikes and the buildup of static electricity. When mounting the Outdoor Access Point on the pole or solid wall, you have to connect the Outdoor Access Point to the same grounding system* with the AC wall outlet. * The grounding system must comply with the National Electrical Code and safety standards that apply in your country.
  2. Instructions for the installation of that conductor to building earth by a SKILLED PERSON.
  3. Please contact the authorized distributor of D-Link for related accessories (outdoor interconnection cable, cable gland, cable, etc.) for purchase and installation.