D-Link DIS-200G-12PS Layer 2 Industrial Managed Switch Instruction Manual

DIS-200G-12PS Layer 2 Industrial Managed Switch

According the “Quick Installation Guide Industrial Ethernet Switch.pdf”, page7:

Device Reset:

  1. Press and hold the reset button for 6 to 10 seconds. All the LEDs on the DIS-200G will light amber. When this happens, release the reset button and the DIS-200G will be reset to factory defaults.
    Note: holding the reset button for more than 11 seconds will cause all LEDs on the DIS-200G to light green. Holding the reset button for a further 2 seconds will put the DIS-200G into boot loader mode.

Based on my test there is no problem with F/W 1.00.043, 1.10.023, 1.10.024, and 1.20.006.
This is my test step:
Reboot:

  1. Login console by [admin/admin] and add new account [test/12345678].
    >>> Switch# conf t
    >>> Switch(config)# username test password test
    >>> Switch(config)# exit
    >>> Switch# copy running-config startup-config
  2. Re-login console by “test/test”.
    >>> Switch>
  3. Holding reset button for more than 11 seconds, the LEDs are light green, and the DUT is rebooting.
  4. Re-login console by “test/test”, it is able to login.

Reset Default:

  1. Login console by [admin/admin] and add new account [test/12345678].
    >>> Switch# conf t
    >>> Switch(config)# username test password test
    >>> Switch(config)# exit
    >>> Switch# copy running-config startup-config
  2. Re-login console by “test/test”.
    >>> Switch>
  3. Press and hold the reset button for 6 seconds, and then release the reset button,
    the LEDs are light amber, and it shows “The configuration is resetting to Factory
    Default” on the console message.
    >>> Switch>
    >>> The configuration is resetting to Factory Default
    >>>
    >>> Save configuration
  4. Re-login console by “test/test”, it cannot login. And the DUT is default.