Honeywell MIWI350 REMOTE PULSAR User Guide
Product Overview
The Model 206 Pulse Transmitter from Mercury Instruments is an adaptable solution for transmitting uncorrected volume pulses to a remote EVC. Refer to the below pulse input wiring for the interface drawing connections from 206 Pulsar to MIWI350.
Electrical Wiring – Remote Pulsar to MIWI350 device
40-6189 Wiring Diagram
Pulsar to MIWI cable connections
Follow the below steps carefully to interface the Pulsar and MIWI350.
- Insert the interfacing cable (40-6189) from the Pulsar through the Pulse Input Gland on MIWI350 device.
- Plug the interfacing cable (40-6189) to the 4-pin connector of the IO Board (TB2).
Refer to Detail L & 40-6189 Wiring Diagram from page 2. - The other end of the interfacing cable (40-6189) runs to the Pulsar Output gland.
- The connector must be inserted into the Pulsar Board as per the Electrical Wiring diagram. Refer to Detail H & 40-6189 Wiring Diagram from page 2.
- The final wiring arrangement will be as below. Cross check each connection with the Remote Pulsar Electrical wiring explained in page 2 in detail.
List of associated cable assemblies pre-installed in the device
Part Number | Description |
22-3194-KIT | KIT, ASSY, MECHANICAL UNCORR SW INPUT BOARD |
40-1583-KIT | WIRE-3 COND.24 AWG BELD 9533 |
40-6189-KIT | KIT, PULSE OUTPUT CABLE 206 PULSER TO MIWI350 |
NOTES
For more information:
To learn more about
Honeywell’s Smart Gas Metering Solutions, visit:
www.honeywellprocess.com or contact your
Honeywell Process Solutions representative.
Honeywell Process Solutions
1280 Kemper Meadow Drive Cincinnati, OH 45240
855-2511-7065 – United States & Canada
302-669-4253 – Outside the United States
©2020 Honeywell International Inc