Honeywell Digital Room Thermostat User Guide

Honeywell Digital Room Thermostat User Guide

User Guide

  • Room temperature
  • Set temperature, inquiry
  • Set temperature, adjustment

  • Switch ON/OFF (frost protection enabled)

Operating indicators

  • Heating demand indicator

  • Frost protection

    Frost protection is not available in cooling operation
  • Fault indicator
  • Low battery indicator



  • Heat/cool changeover

Energy Saving ECO feature

  • Pressing the green ECO button gives a timed period at a different,
    predefined temperature (18°C)
  • To set the ECO energy savings time period
  • Display shows countdown of ECO time remaining
  • Pressing or will now allow the ECO temperature to be changed
  • To exit ECO mode, press ECO button again

Installation



  1. = M3.5

    = No 6

Installer Mode

  • To enter Installer Mode
  • To select a parameter
  • Display
  • Parameter flowchart
  • To change a parameter
  • To exit Installer Mode

Parameters

Description Parameter Range of values Default
Minimum ON/OFF time Ot 1,2,3,4,5 m 1 m
Cycle rate Cr {3,6,9,12} 6
Proportional band width Pb 1.5 … 3.0 K 1.5K
Temperature measurement offset tO 3 … 3 K 0 K
Upper setpoint limit uL 21 … 35 °C 35°C
Lower setpoint limit LL 5 … 21 °C 5°C
ECO temperature / Temperatura ECO ES 5 … 35 °C 18 °C
Heat/cool changeover HC 0, 1

0 = Disable

0

 

1 = Enable
Off setpoint adjust OS — (= Off), 5…16°C 5°C
Electric heat EH 0 (<3A) / 1 (3A – 8A)><3A) / 1 (3A – 8A) 0 (<3A)
Reset parameters FS 0 / 1 1 (factory)