Hitachi R410A Window Air Conditioner Inverter Cooling Installation Guide

Window Type Air Conditioner
Inverter Cooling only Series
R410A 
INSTALLATION & OPERATION MANUAL Model
RAW-VJ07SCASK
RAW-VJ10SCASK
RAW-VJ13SCASK
RAW-VJ18SCASK
RAW-VJ24SCASK
HO2022476HA

Thank you for choosing the Hitachi air conditioner. Please read this operating manual carefully before operating the unit and keep it for consultation.
NOTICE :
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
The appliance shall be installed in accordance with national wiring regulations. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
Please read this operating manual carefully before operating the unit. The figures in this manual may be different from the material objects, please refer to the material objects for reference.

Explanation of Symbol 

DANGER Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word WARNING or CAUTION.

Exception Clauses

Manufacturers will bear no responsibilities when personal injury or property loss is caused by the following reasons.

  1. Damage the product due to improper use or misuse of the product;
  2. Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of the manufacturer;
  3. After verification, the defect of the product is directly caused by corrosive gas;
  4. After verification, the defects are due to improper operation during transportation of product;
  5. Operate, repair, and maintain the unit without abiding by an instruction manual or related regulations;
  6. After verification, the problem or dispute is caused by the quality specification or performance of parts and components that are produced by other manufacturers;
  7. The damage is caused by natural calamities, a bad using environment, or force majeure.

If it needs to install, move or maintain the air conditioner, please contact the dealer or local service center to conduct it first. The air conditioner must be installed, moved, or maintained by the appointed unit. Otherwise, it may cause serious damage or personal injury, or death.
When refrigerant leaks or requires discharge during installation, maintenance, or disassembly, it should be handled by certified professionals or otherwise in compliance with local laws and regulations.

Precautions
Warning

Children shall not play with the appliance.
The air conditioner should be installed in accordance with national wiring regulations.
Air Conditioner should be properly grounded. The incorrect grounding may cause electric shock.

This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.

  • Do not connect the air conditioner to the multi-purpose socket. Otherwise, it may cause a fire hazard.
  • To install the switch. If not, it may cause malfunction.
  • Do not spill water on the remote control, otherwise, the remote control may be broken.
  • Do not spray water on the air conditioner. It may cause electric shock or malfunction.
  • Do not extend fingers or objects into the air inlet or air outlet. It may cause personal injury or damage.
  • Do not step on the air conditioner, or put heavy objects. It may cause damage or personal injury.
  • Do not block the air outlet or air inlet. It may cause malfunction.
  • To disconnect the power supply when cleaning the air conditioner. Otherwise, it may cause electric shock.
  • Do not repair the air conditioner by yourself. It may cause electric shock or damage.
  •  Maintenance must be performed by qualified professionals. Otherwise, it may cause injury or damage.
  • Please contact the dealer when you need to repair the air conditioner.

Please install the devices for short-circuit protection and electrical leakage protection when installing the air conditioner.
According to the local safety regulations, use a qualified power supply circuit and circuit break.

  • Operating condition
    Please operate the air conditioner in the correct conditions as follows.
    COOL mode operation  DRY mode operation 
    The outdoor temperature should be in the range of 18˚C to 43˚C.
    Otherwise, it is possible for the air conditioner to break down.
    Room humidity should be lower than 90%. Otherwise, it is possible
    for the air conditioner to dew at the surface and even drop water after
    running for a long period of time, but this is normal.
    Please refer to P.4 for the indoor temperature range.
    The outdoor temperature should be in the range of 18˚C to 43 ˚C.
    Otherwise, it is possible for the air conditioner to break down.
  • Power requirement
    Rated Voltage : 220 V +/- 10%
    The electric components will be damaged when the voltage is too high. If the voltage is too low, the compressor will vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not to work.
    The ground must be connected. A special socket must be used. Furthermore, the socket and wiring must conform to the wiring regulations. And the earthing
    method must be reliable. In the fixed circuit, there must be an electricity leakage protection switch with enough power capacity and an air switch with enough space.
    Earth wire  To ensure reliable earthing, please do not connect the earth wire to the following places:
    Water pipe

    Operation Temperature : 

    Cooling operation  Outdoor temp:  18-43ºC  / 64-109ºF 
    Indoor temp:  17-32ºC / 62-90ºF 

    Note: Performance may be reduced outside of these operating temperatures.

    Power cord

    1. Model: RAW-VJ24SCASK is supplied without a plug. It needs to be installed by a qualified technician for safety purposes.
    2. Powerpoint requirement: CONNECTION / SPUR UNITS, MINIMUM POWER 220V 30A
    3. Power cord conductors are distinguished according to color as follows (see Fig.A)
    4. For your safety and protection, this unit is earthed through the power cord (see Fig.B)
      Please contact the manufacturer or its service agent or a similarly qualified person if you want to replace it.
    5. Be sure that the unit is correctly grounded. The wall outlet (Switch) should be provided with reliable earth wire.
    6. The unit should be provided with an individual circuit and the circuit breaker/ fuse rating should be the same as that of the power cord.

    NOTE :
    As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your connection units – Proceed as follows :
    The wire which is colored BROWN must be connected to the terminal which is marked L.
    The wire which is colored BLUE must be connected to the terminal which is marked N.
    The wire which is colored YELLOW / GREEN must be connected to the terminal which is marked .

    • Installation 
      Installation precaution:
      Please contact a professional technician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage to the unit.
      Location:
      • The condensation water must be drained away easily.
      • Install air conditioner unit far away from a TV set or radio etc. to avoid disturbing video or voice.
      • Avoid a place where is possible for inflammable gas to leak out.
      • Avoid other heat sources or direct sunlight.
      • Avoid a place that is easy for children to touch.
      Location:
      • The condensation water must be drained away easily.
      • Install air conditioner unit far away from a TV set or radio etc. to avoid disturbing video or voice.
      • Avoid a place where is possible for inflammable gas to leak out.
      • Avoid other heat sources or direct sunlight.
      • Avoid a place that is easy for children to touch.
    • Installation
      Installation procedure :
      1. Remove the sticker from the front panel.
      2. Put the unit into the installation hole.
      When installing the unit, it should slant down to the back to make sure the condensation water can be drained away easily. (Slant about 6-10mm) (Shown in right figure.)
      3. The installation place should be strong enough to avoid the enlargement of noise or vibration.
      4. Fill up sews in the cabinet with sealant.
      Installation assistance :
      • Use iron support
      The installation hole should be strong enough to support the air conditioner.
      If it cannot, iron support has to be used outdoors. Iron support should be fixed on the building (Shown in the right figure.)
      ● Use sunshade board
      The air conditioner should avoid anything to be dropped onto it and avoid direct sunlight. If there is no cover on it, you should contact the seller for installing the sunshade board. When installing the sunshade board, don’t let it block the air inlet at the side grille. 
    • Installation 
    • Drain water for another style :

      To get maximum cooling efficiency, the air conditioner is designed to splash the condensate on the condenser coil. Please install the drainage tray when installing the air conditioner if necessary.
      To the cooling-only unit, if the splashing sound annoys you, you can use an outside drain as shown in the following procedure. However, it may reduce the performance.

    1. Slide out the chassis from the cabinet.
    2. Remove the rubber plug from the body base plate.
    3.  Install the drain tray to the corner of the cabinet with 2 screws.
    4. Connect the drain hose to the outlet on the drain pan bottom.
    5. Slide the chassis into its original place in the cabinet.

    * For RAW-VJ18SCASK and RAW-VJ24SCASK, there will be 2 drain trays provided.
    Select the appropriate drain tray according to the actual condition.

    Note:
    Due to different installation environments and humidity, it is recommended that customers consider installing an external large drain pan and connecting to drain the hose.
    All costs and whether the location of the external large drain pan and drain hose are suitable for installation, please consult with qualified installers.

     

    • Notes for installation
      Removal
      Before removing the air conditioner from the other place, you should contact the seller first.
      Then it must be done under the direction of a professional technician.
      Noise
      • Install in a location that is firm enough to avoid the enlargement of noise and vibration.
      • Don’t put anything in front of the outlet of the unit to avoid enlarging noise.
      • Be sure that hot air or noise will not cause inconvenience to neighbors.
      • Please contact the seller as soon as there is strange noise during operation. Please use the safety support.
      Electric Wiring
      • Must connect with ground reliably.
      • The exclusive circuit must be used. A removable socket can’t be used because of poor contact. It
      can cause overheating or fire.
      • Don’t pull the power cord strongly.
      • In the fixed circuit, there must be an electricity leakage protection switch and the leakage current is less than 30 mA.
      • Switch (circuit breaker) should be installed in the circuit and its capacity is 15 A (RAW-VJ07SCASK,
      RAW-VJ10SCASK and RAW-VJ13SCASK), and 30 A (RAW-VJ18SCASK and RAW-VJ24SCASK)
    • Installation Steps
    • Step 1. Remove the front panel and the air filter

    1. Hold the slot under the front panel, then uplift outwards, and remove the front panel  (See Fig. 1).
    2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from under ide to upside (See F fig. 2).
    3. Cut and remove the cable tie (See Fig. 3) fixing between the panel and the temperature sensor behind the air filter. (Only applicable for RAW-VJ18SCASK and RAW-VJ24SCASK.
    Step 2. Remove the frame.
    1. Remove one screw on the chassis fixing bracket, then remove the chassis fixing bracket.
      Remove the two screws located on the back of the cabinet as shown in Fig. 4 if necessary.
    2. Grasp the left corner of the frame’s underside, then loosen the frame. (See Fig. 5).
      After that use a flathead screwdriver to press the clip connecting the control panel and the frame, and finally remove the frame.
    3. Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet (See Fig. 6). Rubber Plug is fixed in the drain hole. Please use the spare rubber plug given into the package if necessary.

    Step 3. Install the frame.

    1. Push the unit chassis into the cabinet (S ee Fig. 7).
    2. Install the frame (See Fig. 8) and fix the screws on the frame (See Fig. 4)

    Step 4. Install the air filter and front panel.

    1. Install the Silver Ion air filter into the frame’s slot from upside to underside. (See Fig. 9).
    2. Hang the front panel on the frame’s buckle, then press the front panel into the frame e’s slot until you hear a click (S ee Fig. 10)

    Operation procedure

    • Part identification 
      The panel outlook picture is just for reference, please take the real unit as a standard outlook.
    • Airflow direction Adjustment
      Horizontal airflow direction vane
      (Airflow direction adjustment up and down)
      The horizontal airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards, or straight out.
    • r Filter
      The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain the optimal performance of the air conditioner.

      How to remove the air filter
      Tum off the unit, tum off the circuit breaker
      1. Hold the tabs under the front panel, then uplift it outwards over the protection tab or remove the front panel.
      2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from the underside to the upside.
      3. Clean the filter with warm soapy water. The water should be below 40°C to prevent distortion of the filter.
      4. Rinse off and gently shake off excess water from the filter. Allow the filter to dry before placing back. To prevent distortion of the filter, do not dry under direct sunlight.

       

       

    • Cabinet Cleaning
      • Be sure to unplug the air conditioner to prevent shock or fire hazards. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
      • Never use harsh cleaners, wax, or polish on the cabinet front.
      • Be sure to wring excess water from the cloth before wiping around the controls.
      • Excessive water in or around the controls may cause damage to the air conditioner.
      • Plug in the air conditioner.
      NOTE:
      Never use water over 40˚ C, alcohol, gasoline, acid, solvent, or brush to clean the front panel as this will damage the surface of the part.
      Winter Storage
      If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or place it in the original carton.
      CAUTION
      NEVER operate the air conditioner without the air filter, as dust/dirt particles can contribute to equipment failure.

    • Remote control operation procedure
      Note:
      This is a general use remote control, it could be used for air conditioners with multifunction. For some functions which the model doesn’t have, the unit will keep the original running status if pressing the corresponding button on the remote control.

       

    1. On/Off button
    2. Mode button
    3. + /- button
    4. Swing button
    5. Fan button
    6. Sleep button
    7. Timer button
    8. Light button
    9. Health button (not applicable)

    1. On / Off button
    Press this button to turn on the unit. Press this button again to turn off the unit.
    2. Mode button
    Press this button to select your required operation mode. The corresponding indicator will be on.

    • Auto:
      Under this model, the unit will operate automatically according to the default setting.
      In this case, the set temperature cannot be adjusted.
    • Cool:
      Under this model, the air conditioner operates under cooling mode. The cooling indicator will be on. Press the “Fan” button to adjust the fan speed.
      • Dry: Under this model, the unit runs at low fan speed for dehumidifying and the corresponding indicator is on; under the dry mode, the fan speed cannot be adjusted.
      • Fan Only: Under this model, the air conditioner will not operate in COOL mode but only blow wind. The fan indicator will be on. Press the “Fan” button to adjust the fan speed.

    3. + / – button

    • Pressing the “+” or “-” button once will increase or decrease the set temperature by 1°F(°C). Hold the “+” or “-” button for 2 seconds, and the set temperature on the remote control will change quickly. Release the button after your required set temperature is reached.
    • Under timer setting status, after each pressing of the “+” or “-” button, time will increase or decrease by 0.5 hours. Hold the “+” or “-” button, 2 seconds later, the time displayed on the dual-8 nixie tube will change quickly. Unpress the button until the time is reached your set time.

    4. Swing button
    Press this button to turn the “ON” & “OFF” swings.
    5. Fan button
    This button is used for setting fan speed in the sequence that goes from AUTO, , , to and then back to Auto.
    NOTE: There are 3 fan speeds in this model.

    6. Sleep button
    Press this button to go into the Sleep operation mode. Press it again to cancel this function. This function is available in COOL mode to maintain the most comfortable temperature for you.
    7. Timer button
    Under ON status, press this button to set the timer OFF; Under OFF status, press this button to set the timer ON.
    Press this button once and the characters of HOUR ON (OFF) will flash to be displayed. Meanwhile, press the “+” button or “-” button to adjust the timer setting (time will change quickly if holding the “+” or “-” button). The time setting range is 0.5~24hours. Press this button again to confirm the timer setting and the characters of HOUR ON (OFF) will stop flashing.
    If the characters are flashing but you haven’t pressed the timer button, the timer setting status will be quitted after 5 seconds. If the timer is confirmed, press this button again to cancel the timer.
    8. Light button
    Press the button to activate or deactivate the LED (Light) on the control panel.
    9. Health button (Not Applicable)
    WiFi Function (Not Applicable)
    WiFi functions are not applicable for models of RAW-VJ07SCASK / RAW-VJ10SCASK / RAW-VJ13SCASK / RAW-VJ18SCASK and RAW-VJ24SCASK.
    Press the “Mode” + “Timer” button together to disappear the “WiFi” symbol onto the display.
    Function introduction for combination buttons
    Temperature display switchover function
    Under OFF status, press the “-” and “Mode” buttons simultaneously to switch temperature display between °C and °F

    Replacement of batteries in remote control

    1. Press the back side of the remote control marked with “ “, as shown in Fig., and then push out the cover of the battery box along the arrow direction.
    2. Replace two (AAA 1.5V) dry batteries, and make sure the position of “+” polar and “-” polar are correctly placed.
    3. Reinstall the cover of the battery box.

    NOTICE :

    • The distance between the signal sender and receiving window should not be more than 8 meters, and there should be no obstacles between them.
    • As the signal will interfere in the room with an electronic fluorescent lamp, conversion fluorescent lamp, or wireless phone, please get closer to the air conditioner when using the remote control.
    • Replace new batteries of the same model when replacement is required.
    • When you don’t use the remote control for a long period of time, please take out the batteries.

    • Remote control panel
    Note: 
    If the wireless remote control is lost, you can use the remote control panel and operate it manually.

    1. ON/OFF BUTTON
    Operation starts when pressing this button. Press this button again to stop the operation.
    2. SWING BUTTON
    Activate the automatic air swing function.
    3. FAN SPEED BUTTON
    Select the fan speed LOW, MID, HIGH, and AUTO in sequence.
    4. TIME/TEMP BUTTON
    Press the keypad to increase the set (operating) temperature of the unit.      
    Press the keypad to decrease the set (operating) temperature of the unit.
    The temperature setting range is from 16~30°C.
    For the time setting range from 0~10 hours, press the keypad to increase the selected time on a 0.5-hour increment, and press the keypad to decrease the selected time in a 0.5-hour decrement.
    For the time setting range from 10~24 hours, press the keypad to increase the selected time on a 1-hour increment, and press the keypad to decrease the selected time in a 1-hour decrement.
    5. SIGNAL RECEIVER
    6. MODE BUTTON
    Select the operation mode COOL, DRY, FAN (for cooling only model).
    7. FILTER BUTTON
    This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED (Light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the “Filter” button and the light will go off. Before the LED (Light) illuminates, press the “Filter” button for 3 seconds to clear the accumulated time of operation.

    • Operation Tips
    Operation for comfort and economy

    Do not overcook the room temperature. This is not
    good for health and causes a wasting of electricity.
    Keep the blinds or curtains closed. Do not let sunshine enter the room directly when the air conditioner is in operation. Keep the room temperature consistent. Adjust the vertical and horizontal airflow direction
    to ensure the consistent temperature in the room. Air can’t be discharged in the direction of air-in.
    Make sure that the doors and windows are tightly closed. Avoid opening doors and windows frequently in order to keep the air conditioning in the room. Clean the air filter regularly. Blockages of the air filter reduce dehumidifying effects. Clean the air filter at
    least once every two weeks.
    Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them
    and ventilate the room. When starting the unit, curtains or windows should be closed to prevent cool air leakage.

    Care and maintenance

    • Caution
    Operations for safety and health

    1. The plug must be accessible after the appliance is positioned.
    2. Do not use this appliance in the laundry.
    3. If the power cord is damaged, it must be replaced by the manufacturer or its service agent to avoid hazards.
    • Do not pull out the power cord.
    • Damage to the cord may result in serious electric shocks.
    • Do not use the air conditioner for other purposes except for cooling the room.
    • Do not use the air conditioner for other purposes such as drying clothes, preserving foods, or cultivating vegetables.
    • Do not block the air intake and outlet vents. This causes reduced performance and irregular operation.
    • Do not insert sticks or other objects into these vents as it is dangerous to touch the electric components and the fan.
    Select the optimal temperature. Pay attention to adjusting the temperature to suit the conditions. Rooms occupied by infants, the elderly, or the sick should be kept under an appropriate temperature. Do not use heating apparatuses in the vicinity.
    The air conditioner’s plastic parts will melt if exposed to excessive heat.
    Avoid exposing the body directly to airflow for long periods.
    This is not recommended for health reasons.
    Always wait at least 3 minutes before switching the air conditioner on again after you have switched it off during cooling.

    • Cleaning and maintenance

    1. Cut the power off before cleaning.
    2. Use a soft cloth when deaning the cabinet. If the cabinet is very dirty, dip doth into warm water below 403C dry the cloth, and then rub off the dirt.
    3. Don’t use gas, benzene, solvent wash, chemical solvent, etc. for cleaning.
    4. Do not splash water directly into the unit, in which there are micro-computer and circuit plates, they must not be drenched with water.

    *Check earth wire

    Air filter
    The air filter behind the intake grille should be washed at least once every two weeks or as often as it needs cleaning.
    How to clean the air filter:

    1. To remove the air intake grille, grasp the tab on the filter and pull to take out
    2. Vacuum the filter on the dusty side to remove light dust.
    3. Wash the filter, cleaner side up under gently flowing water to wash out accumulated dust and lint.
    4. If the filter is very dirty, clean it with mild household detergent in water.

    Let the filter dry thoroughly before reinstalling it. If necessary, please ask the professional personnel to clean it.

    * Check if the air inlet and outlet of the unit are blocked or not.

    • Troubleshooting guide
    Please check the following items before asking for repair, it saves your time and money.

    Fault phenomenon Troubleshooting
    The air conditioner does not operate at all. * Is there a power failure?
    * Is the plug out?
    * Is the power fuse or switch off?
    * Whether the voltage is too high or too low?
    Cooling efficiency is not good. * Is the air inlet or outlet blocked?
    * Is there any other heat source in the room?
    * Are air filters dirty?
    * Is the indoor fan speed set at LOW? * Maybe the room is too hot when the unit starts.
    Foggy air flows out. * At COOL mode operation, sometimes there is foggy air flowing out from the unit, this is because the room’s humid air has been cooling rapidly.
    * The unit is normal while the indoor outlet is sending out some odor, because the inlet air may be mixed with the smell of furniture and smoke.
    The air conditioner operation is noisy. * For a noise that sounds like water flowing:
    This is the sound of freon flowing inside the air conditioner unit.
    * For a noise that sounds like a shower, This is the sound of the dehumidifying water being processed inside the air conditioner unit.
    It seems that condensate is leaking from the air conditioner. Condensate occurs when the airflow from the air conditioner cools the warm room air.
    The air conditioner does not operate for about 3 minutes when restarted. * This is to protect the mechanism.
    * Wait about 3 minutes and operation will begin.

    Care and maintenance

    Immediately stop all operations and plug out or isolate the power supply, please contact your dealer in the following situations.
    * Operation starts or stops abnormally;
    * Power fuse or switch often breaks;
    * Carelessly splash water or something into the air conditioner;
    * Electrical lines are much hot or lines cover breaks;
    * Burning smell or smoke formed.
    *Other strange situations.

    Others
    Model and rated value of fuse shall be subject to screen print on the corresponding controller or protective bushing.

    • After-sales service
    If your air conditioner has questions about quality or malfunction, please contact the service center.

    Arçelik Hitachi Home Appliances Sales Hong Kong Limited
    Office: 18/F, Ever Gain Centre,
    28 On Muk Street Shatin, N.T.
    Hong Kong, China
    Tel No. : +852 2113 8883
    Fax No. : +852 2783 8535

    General Enquiry
    Tel No. : +852 2770 0377
    Email address:

    Hong Kong Repair Service
    Tel No. : +852 2753 5386
    Email address:

    Correct Disposal of this product
    This marking indicates that this product should not be disposed with other household wastes throughout the EU.
    To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.
    Specifications in this document are subject to change without notice, in order that Hitachi-Johnson Controls Air Conditioning, Inc. may bring the latest innovations to their customers

    Hitachi-Johnson Controls Air Conditioning, Inc.
    © 2022 Johnson Controls Hitachi- Air Conditioning, Inc.
    2022.05
    Version. A
    Printed in China