Honeywell HZ322 TrueZONE Panel User Guide

Honeywell logo

HZ322 TrueZONE® Panel

SUBMITTAL SHEET

Job Name
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Notes
Model(s)
HZ322 Qty. Notes

HZ322K (Kit
Qty. Notes
Approval
Service
Tag No.

Honeywell HZ322 TrueZONE Panel

APPLICATION

The HZ322 TrueZONE panel controls:

  • Conventional gas, oil, or electric forced-air systems up to 2 stages heat and 2 stages cool;
  • Heat pump systems with single-stage compressor and auxiliary heat;
  • 2 or 3 forced-air zones with wired thermostats, or wireless thermostats using an optional wireless adaptor.

FEATURES

  • Intuitive installer setup with easy-to-follow, digital the display uses real language to guide the installer through configuration
  • Universal application for any HVAC system using conventional thermostat wiring (R W Y G C etc.)
  • Standard checkout procedure ensures correct operation before leaving the job
  • Robust push terminals for up to two wires per terminal
  • Common-sense LEDs indicate the stage of heat and damper state
  • Control of two or three-wire dampers with open or closed logic
  • Variable-speed fan control lowers fan speed when one zone is calling for cooling
  • Discharge air temperature down-stages equipment when near high or low limit

SPECIFICATIONS

Input Ratings:
Voltage: 18-30 VAC 50/60 Hz powered by a transformer of 40 VA or more
Current Draw:
Zone Panel: 7.5 VA max. All VA specifications at 24 VAC.
Wiring: 18- or 20-gauge solid (not stranded) wire
Humidity Ratings: 5 % to 90 % RH non-condensing
Temperature Ratings:
Shipping: -20° to 150 °F (-29° to 66 °C)
Operating: -40° to 165 °F (-40° to 74 °C)
Dimensions: See Fig. 1.
Mounting:
Mounts with either 2 screws at the centerline to mount onto 2x 4, or with 4 screws at corners for a wall mount.
Recommended Thermostats: See Table 1.
Recommended Dampers: See Tables 2 and 3.
For a maximum number of dampers per zone see Table 4.
Accessories:
See Table 5.
Emissions:
Complies with FCC Class B, part 15 requirements.

Fig. 1. HZ322 TrueZONE panel dimensions in in. (mm).

Table 1. Recommended thermostats.

RedLINK thermostats:
TH8110R1008 (wired or wireless*) Single-stage heat and cooling. No IAQ.
TH8320R1003 (wired or wireless*) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. No IAQ.
TH8321R1001 (wired or wireless*) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. Hum, Dehum, or Vent control when used as wired thermostat, or wireless to a THM5421R1021 EIM. EIM wired to one of the zones.
THX9421R5021 Prestige (2-wire R and C. Wireless to THM4000R/HZ322 or THM5421R1021 EIM.*) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. Hum, Dehum, and Vent control when used with THM5421R1021 EIM. EIM wired to one of the zones.
TH6320R1004 programmable FocusPRO (wireless*) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. No IAQ.
TH5320R1002 non-programmable FocusPRO (wireless*) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. No IAQ.
Wired thermostat
Battery-powered, hard-wired, or mechanical The HZ322 is compatible with most standard thermostats. The HZ322 allows you to choose stage 2 (and stage 3) control to be by thermostat, timer, or % of zones. If you want the thermostats to control staging, multi-stage thermostats are required.
Power stealing or phantom voltage (Lyric round, etc.) We do not recommend using thermostats that operate on phantom voltage or power-stealing mode with the HZ322. Some of these models have an optional C wire. Models tested with a C wire worked correctly with the HZ322.
* RedLINK models without IAQ control need a THM4000R1000 wireless adaptor. One adaptor can be used for up to 3 RedLINK thermostats on HZ322. If IAQ control is required from the TH8321R1001 or THX9421R5021 model, a THM5421R1021 is required for the thermostat controlling IAQ equipment. That EIM wires to one of the zones on the HZ322.

Table 2. Recommended residential dampers.

Type Actuation Round Rectangular
Zone Spring-open/power-closed ARD ZD
Power-open/power-closed RRD
Bypass Barometric CPRD None

Table 3. Recommended commercial dampers.

Type Actuation Round Rectangular
Zone Power-open/power-closed MARD D2 with ML6161A2009*
Bypass Power-open/power-closed MARD with SPC D2 with ML6161A2009* and SPC
*Or equivalent damper and actuator.

Table 4. Maximum dampers*

Ambient Temp. Maximum Damper VA per Zone
100°F (38°C) 28.8
160°F (71°C) 16.8
* Use an SDCR (Secondary Damper Control Relay) for additional dampers.
•Maximum dampers per panel is limited by transformer size.
•Ensure the transformer is large enough to power the panel (7.5 VA) and dampers.

Table 5. Accessories.

Description Part Number
40 VA transformer AT140A1042*
75 VA transformer AT175A1008
Discharge air temperature sensor (DATS) C7735A1000*
Outdoor Air Sensor (wired) C7089U1006
Outdoor Air Sensor (wired) C7089R1013 (THM4000R1000 wireless adaptor required)
Wireless adaptor THM4000R1000
Secondary damper control relay SDCR
*Included in HZ322K kit.