Panasonic CW-HZ70ZA Room Air Conditioner Instruction Manual

 

OPERATING INSTRUCTIONS
ROOM AIR CONDITIONER
ACXF55-30110
CW-HZ70ZA/CW-HZ90ZA
CW-HU70ZA/CW-HU90ZA

WARNING
This symbol shows that this equipment uses a flammable refrigerant.
If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.
CAUTION
This symbol shows that the Operating Instructions should be read carefully.
CAUTION
This symbol shows that service personnel should be handling this equipment with reference to the Technical Manual.
CAUTION
This symbol shows that there is information included in the Operating Instructions and/or Installation Instructions.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

SAFETY PRECAUTIONS

Please observe the following safety precautions when using your air conditioner.
Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.

WARNING: This sign warns of the risk of death or serious injury.
CAUTION: This sign warns of the risk of injury or damage to property.
This symbol (with a white background) denotes an action that is PROHIBITED.
These symbols (with a green background) denote actions that are COMPULSORY.

INSTALLATION PRECAUTION

WARNING
Do not install, remove and reinstall the unit yourself.
Improper installation may cause leakage, electric shock, or fire. Please engage an authorized dealer or specialist for the installation work.
Do not add or replace refrigerants other than the specified type.
It may cause product damage, burst, and injury. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
The appliance shall be stored in a room without continuously operating ignition sources (for example open flames, an operating gas appliance or an operating electric heater)
In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
Ventilate any enclosed areas when installing or testing the refrigeration system.
Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning
stove, gas water heater, electric room heater, or another heat source, it can cause the generation of toxic gas.

CAUTION
The room air conditioner must be earthed.
Improper grounding could cause electric shock.
Do not install the unit in a place where there are explosive gas leaks.
Gas leaks near the unit could cause a fire.
Ensure that the drainage piping is connected properly.
Otherwise, water will leak out.

Risk of fire / Flammable materials
R32

OPERATION PRECAUTION

WARNING
This sign warns of the risk of death or serious injury.

  • Do not modify the length of the power cord or use an extension cord.
  • Do not touch or operate with wet hands.
  • Do not modify or damage the cord.
  • Do not turn on the unit by inserting the power plug.
  • Do not switch off the unit by pulling out the power plug.
  • Avoid any extended period of direct airflow.
  • Do not insert your fingers or other objects into the unit, rotating parts may cause injury.
  • Do not try to repair the unit yourself.

  • Plugin properly before operating and use a specified power cord.
  • If abnormal conditions (burnt smell, etc.) occur, switch off and remove the power plug.
  • Confirm to authorized dealer or specialist on the usage of specified refrigerant type. Using refrigerants other than the specified may cause product damage, burst, and injury, etc.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

CAUTION

This sign warns of the risk of injury or damage to property.

  • Do not use the unit for other purposes, than its intended use.
  • Do not remove the power plug by pulling the cord.
  • Do not block the air intake and outlet vanes.
  • Do not splash or direct water at the unit.
  • Do not expose the unit to direct sunlight during operation.
  • Do not operate the unit without the air filter installed or when the front intake grille has been removed.
  • Do not place any objects on the unit.
  • Do not operate any combustion equipment near the unit’s airflow area.
  • Do not sit or step on the unit, you may fall down accidentally.
  • Do not touch the sharp aluminum fin, sharp parts may cause injury.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

  • Switch off the breaker and unplug the unit from the socket if the unit will not be operated for a long period.
  • Pay attention to any damages on the unit caused by extensive usage.
  • Ventilate the room occasionally where the unit is installed.
  • Unplug the power cord when cleaning the unit.

PARTS IDENTIFICATION

MAIN UNIT

Touch Control Panel

TYPES OF SIGNAL SOUND – One long “BEEP” and one short “BEEP(Sound from the main unit.)

  • When the filter cleaning light flashes or brighten,it is recommended to clean the filter after dismantle. Filter cleaning light will flashes about 20 seconds,if didn’t press the “MAIN UNIT RESET“, it will keep brightening after flashes about 20 seconds.
  • After the filter is cleaned, please lightly press the”Reset” button on the remote control or touch theFILTER CLEAN button on the control panel, and the unit will beep once (the model filter cleaning light goes out).
  • When the machine has been running for 500 hours, the filter cleaning light will flash for about 20 seconds and then go out after the machine is turned on and off. If it is not reset, restart the timer. After the machine is turned on for 800 hours, the filter cleaning light will flash for about 20 seconds and then stay on.
ACCESSORIES

Remote control
Be sure to observe the following:

  • Aim the remote control at the control panel on-air conditioner when operating.
  • Do not drop or throw the remote control.
  • Do not place the remote control in a location that is exposed to direct sunlight or next to a heating unit or other heat souces.

PREPARATION BEFORE OPERATING

WARNING

Ensure that the power plug is securely inserted.
A loose plug may cause a fire or an electric shock.

NOTES:
If the unit is not going to be used for an extended period of time, remove the power plug. Otherwise, approximately 2.5W of electricity will be used even if the unit has been
turned off using the remote control.
If the operation is stopped, and to be restarted immediately, the unit will resume operation only after 3 minutes.

HOW TO INSERT BATTERIES

CAUTION
Do not use rechargeable (Ni-Cd) batteries because such batteries differ from the standard dry cell batteries in shape, dimensions and performance.

ABOUT THE BATTERIES

The batteries can be used for approximately one year.
Be sure to replace the batteries with two new identical batteries.
Remove the batteries if the air conditioner will not be used for an extended period of time.

OPERATION CONDITIONS
Use the air conditioner under the following conditions:

  • Operating temperature range.
    Continuous operation at over 90% high humidity may create condensation and result in water drops on the intake and outlet vanes.
  • Avoid installation in the following locations.
  • Mechanical processing plants and other places with a lot of mechanical oil.
  • High humidity areas such as laundry room and bathroom.
  • Air conditioner COOLING/HEATING normal operating temperature.
  • In side maximum temperature 30(30) ℃, lowest temperature 16(16) ℃
  • Out side maximum temperature 43(24) ℃, lowest temperature 16(0) ℃
  • NOTICE:
    When the air conditioner is used at a room temperature of 21 degrees or less, the temperature may be too low, and the air conditioner may be easily frosted. After frosting, it may be difficult to drain and may flow into the room.

AIR CONDITIONER INSTALLATION

CHOOSING THE INSTALLATION LOCATION

  • When installing, use the nearest power outlet. Make sure the power outlet is easy to reach so you can quickly disconnect your air conditioner in case of an emergency.
  • Ensure that the air conditioner is well supported, securely fastened, easily reachable, and not obstructed.
  • Avoid location with: salty or sulfurous air, draughts, dampness, and flammable gas.
  • If you install the drainage system, be sure to channel the condensed water to a suitable location.
  • Covers, obstructions, and unsteady support may cause excessive operating noise and vibration.
  • The rear end of the air conditioner is splash-proof.
  • You don’t need to shield or cover it.
  • Installation and maintenance should be done by a competent person.
PREPARATIONS BEFORE INSTALLATION

Dimension

  • There should not be any obstacles surrounding the unit.
  • Prepare and install hole slightly bigger than the cabinet size.
  • The Left and right sides of the unit should be at least 15 cm away from the wall.
  • The minimum installation height is 75cm.
    (Based on IEC 60335-2-40, there is no restriction for the minimum installation floor area since the refrigerant charges is less than 1.224kg.
CAUTION POINT DURING INSTALLATION

When installing air conditioner at a glass window or thin partition, fix the vertical and side supporting bar to the concrete wall in order to support the weight of the air- conditioner and reduce the vibration that is being transferred to the glass window or thin partition.

This can minimize the noise problem caused by improper installation.
Proposed to use 1/8” x 1-11/4” “angle aluminum for installation frame and side supporting bar.

INSTALLATION PROCEDURES
  1. Remove the rear cabinet screws and chassis locking bracket from the cabinet. Save for later use.
  2. Slide the chassis out from the cabinet
  3. Place the cabinet into the installation hole.
  4. Slide the chassis into the cabinet.
  5. Lock the chassis to the cabinet reusing the chassis locking bracket.
  6. Depending upon the location of the AC outlet, route the AC cord to either left or right side before installing the front grille.
  7. Attach the front grille to the cabinet and fasten it with a screw.
  8. Attach air filter to the front grille. (see anti-bacterial filter installation instructions included in this package)
  9. The control panel keeps it horizontal, the panel arm both sides inwardly adapted to match the panel pivot point with the body support portion at the same time.
  10. Press down the control panel and close the cover

REMOVAL OF FRONT GRILLE

  1. Open the Intake Grille until over 90°
    front grille fulcrum can remove from Grille force arm.
  2. Remove the air filter.
    Tilt-up and pull out the air filter by the holder.
  3. Remove the front grille.
    a. Remove the screw on the front grille.
    b. At the bottom right side of the front grille, press inward on the cabinet near the power cord, and pull the grille outward to the right until right tab releases.
    c. At the bottom left side, push inward on the cabinet and pull the grille outward to the left to release the left tab. Do not pull the bottom edge towards to you for more than 3 inches to prevent the two top tabs from damage.
    d. Slide the front grille upwards to loosen the two top tabs from slots at the top of the cabinet.
ELECTRIC WORK
  • Always use at the rated voltage and with a specific air conditioning circuit.
  • This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electric shock or fire in case of malfunction.
  • A 16 Ampere time-delay fuse or circuit breaker is required.
  • The nominal cross-sectional area of the power supply wire must be 3 core x 1.5 mm or above.
  • The power supply must be from an independent circuit.
  • All electrical installations must be made in accordance with local wiring and safety regulations wherever applicable.
  • There must be a double pole switch with a minimum of 3.5 mm contact gap in the fixed installation circuit.
  • Please engage an authorized dealer or specialist for the installation work.
CONDENSED WATER DRAINAGE

HZ series
This air conditioner is an “INVERTER” model, in order to prevent water overflows from the machine, please make sure to provide outside drainage by using the following procedure.
HU series
This air conditioner is an “INVERTER COOLING” model, The design of spraying condensate water on the condenser to achieve the best cooling effect. This method is called the “throwing system”. If the sound of spraying makes you annoying, you can use the following methods for outdoor drainage, but the performance will be slightly reduced.

  1. Remove the rubber plug and chassis locking bracket from the cabinet. Then slides the chassis out from the cabinet.
  2. Install the drain pan
  3. Connect a drain hose. Fit the drain hose to the drain pan. Underside view with drain pan and hole in place.
    NOTE: Drain hose or tubing can be purchased locally to satisfy your particular needs.
  4. Slide the chassis back into the cabinet. Lock the chassis to the cabinet reusing the chassis locking bracket. Then reinstall the cabinet to the chassis.
NOISE CONSIDERATION
  • Select an installation location that can support the weight of the air conditioner and one that will not cause increased operating noise and vibration.
  • Ensure that when installed, airflow and noise from the rear side of the unit (outdoor) do not disturb neighboring elements.
  • Obstacles placed in front of the air outlet on the rear side of the unit (outdoor), or covers placed over it will cause excessive noise and deterioration in performance.

TRANSFERRING

  • Repositioning or transfer of the air conditioner due to renovation or moving requires an additional service charge. Please consult your dealer before moving.

AIR CONDITIONER OPERATION

OPERATING THE UNIT

/ Start operation by pressing OPERATION.
The operation will turn on and the display panel will light up.
To stop the operation, press the OPERATION again.
The unit will stop operating and the display panel light will turn off.

SETTING DISPLAY TEMPERATURE

/ / Press TEMP/TIMER▲or▼to set the display temperature.
The temperature can be set between 16°C and 30°C.
Recommended temperature: 26°C~28°C
NOTES:
●The temperature displayed by the room temperature of this unit is the temperature near the air-conditioner suction window, not the room temperature of every corner of the room, and is for reference only.

SELECTING OPERATION MODE

HZ series

Press MODE to select the desired operation.
(The indicator will light up and a “beep” sound will indicate changing the setting)
AUTO mode
Air conditioners are automatically selected according to indoor and outdoor temperatures.
COOL mode
To set room temperature to your preference of cooling comfort.
HEAT mode
To set room temperature to your preference of heating comfort.
DRY mode
DRY mode unit operates at low fan speed to give a gentle cooling operation.

HU series

Press MODE to select the desired operation.
(The indicator will light up and a “beep” sound will indicate changing the setting)
AUTO mode
Air conditioners are automatically selected according to indoor and outdoor temperatures.
COOL mode
To set the room temperature to your preference of cooling comfort.
DRY mode
DRY mode unit operates at low fan speed to give a gentle cooling operation.
SELECTING FAN SPEED
Press the FAN SPEED selection button to choose fan speed level of the fan.
(The indicator will light up and a “beep” sound will indicate changing the setting)
If the air conditioner automatically selects COOL or DEHUMIDIFYING mode and the fan speed is at AUTO speed, it will operate the “Self-cleaning” function to clear the dust on the Heat exchanger,(Defer air flow for 40 seconds or intermittently operate)
ADJUSTING HORIZONTAL AIRFLOW DIRECTION

 

Press the AIR SWING button to select the air swing direction angle.
(The indicator will light up and a “beep” sound will indicate changing the setting)
Press the upper button to adjust the left and right airflow direction.
Press the lower button to stop AIR SWING.
POWERFUL OPERATION
To reduce/increase temperature quickly :
Press the POWERFUL button, after powerful is selected, the operation will go on
for 4 hours, after that, it will shift back to the previous operation mode.
If you want to cancel this operation, press the powerful button once more.
SETTING THE OFF TIMER
When the air conditioner is OFF:
Press the ON TIMER button to set the timer.
Press the same button until the preferred hour of operation is reached.
(The TIMER indicator light will blink to await for setting)
Press the TIMER SET button to complete the setting. At this time, the TIMER indicator light is steady instead of blinking.
NOTE:
it is unavailable to set ON TIMER and OFF TIMER simultaneously.
The timer figure will change according to the time remaining.
QUIET OPERATION
To reduce/increase temperature quickly :
Press the QUIET button.
If you want to cancel this operation, press the QUIET button once more.
SETTING THE ON TIMER
When the air conditioner is ON:
Press the OFF TIMER button to set the timer.
Press the same button until the preferred hour of operation is reached.
(The TIMER indicator light will blink to await for setting)
Press TIMER SET button to complete the setting. At this time, the TIMER indicator light is steady instead of blinking.
NOTE:
it is unavailable to set ON TIMER and OFF TIMER simultaneously.
The timer figure will change according to the time remaining.
CANCEL OFF TIMER SETTING
Press the CANCEL button to cancel the timer setting. The CANCEL indicator light will turn off.
However the temperature remains displayed.
CANCEL OFF TIMER SETTING
●When the OFF/ON button is pressed, the nanoe™X function automatically starts operation.
●To manually ON (start) or OFF (close) this operation, press. (nanoeX indicator is on or off)
●Even when the machine is turned off, this operation can still be activated. In this case, the blades and air volume will be operated according to the remote control settings.
●If a power interruption occurs during operation, the operation will resume immediately after the power is restored.
Note: When nanoe ™X is in action, it will produce nano-ions, so sometimes it will make a little sound.
If you really care about this sound, please turn off this function.
Note: NanoeX can also be started in HEAT mode, and nanoeX can be started independently when COOL/HEAT/DRY is not running.
Note: When nanoeX is started alone, the remote control display screen is shown on the right The air volume and direction can be adjusted automatically (ON or OFF)
  • nanoeX can keep skin moisturized and hair soft.
    (The effect on skin and hair will vary according to the season, surrounding environment (temperature, humidity), usage time and personal conditions.)
  • nanoeX can alleviate the peculiar smell in the room and inhibit the growth of bacteria and mold.
    (It can also effectively reduce the odor (smoke and oily smoke) or bacteria attached to the curtain.
    The inhibitory effects of bacteria and molds are the results of demonstration in confined spaces, not actual use of space.
    In addition, the deodorizing effect will vary depending on the environment (temperature, humidity), operating time, ozone, and fiber type. )
  • As nanoeX is produced by using the air in the room, it may not be produced due to temperature and humidity conditions.
  • Production conditions:
    Indoor temperature: about 5 ℃~35 ℃
    (Dew point temperature: above 2 ℃)
    Relative humidity: about 30%~85%
SLEEP(Cooling mode)
●This setting enables the human body to enter sleep and automatically adjust the
temperature to achieve sleep comfort and energy-efficient operation.
●When the sleep button is pressed (or touch control panel sleep light on),
the air conditioner enters the sleep stroke. Press it again to cancel the sleep schedule.
●After sleep is activated, the SLEEP LED is on, and pressing it again will cancel
the sleep mode (SLEEP LED is dim).
●SLEEP mode is released when the machine is turned off.
Note: During sleep operation, in order to avoid over-cooling and over-heating, the temperature, air volume and wind direction have nothing to do with the remote control settings and will be adjusted automatically.
If the user needs cannot be met, the temperature or air volume can be reset.
◆After the body enters the sleep state, the temperature will be lost due to heat, so in the sleep mode, the air conditioner will keep running for one hour or increase by 1°C after reaching the set temperature, so that people have a comfortable sleeping environment.

HELPFUL INFORMATION & ENERGY SAVING HINTS

HELPFUL INFORMATION

Auto Restart Control

  • The operation will automatically resume under the previous operation mode.
  • If the unit was set to TIMER mode or SLEEP mode, the operation will not resume automatically.
    Timer Setting
  • When a power failure occurs, the timer setting is canceled. Once power returns, reset the timer.

ENERGY-SAVING HINTS

  • Clean the air filter every 2 weeks. Regular cleaning of the air filter preserves efficiency.
  • Keeping ventilation set to close keeps cool air in and hor air out.
  • Avoid direct sunlight and heat.
  • For health, reasons do not overcook your room.
  • Your air conditioner’s cooling capacity should match your room size.

CARE AND MAINTENANCE

WARNING
Always turn off the air conditioner and the main power supply before cleaning the unit.
Switch off the power supply if the unit is not going to be used for a long period of time.

  • Clean the cabinet, front grille with mild soap or detergent and lukewarm water.
  • The front intake grille can be easily removed for cleaning purposes (refer to Remove the front intake grille procedures). Gently wash it with water and a sponge.
  • The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the rear with water. If it is badly spoiled, wash with a mild household detergent.
  • Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.
  • If the unit is extremely dirty, heat transfer is less efficient and the unit may not cool effectively. Contact Shun Hing Electric Service Center Ltd. for an annual check. (Annual check is not covered by the warranty.)
  • If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted.

NOTE: Do not dry the front panel or the air filter in direct sunlight.
(Exposure to direct sunlight may discolor deform the panel.)

PRE-SEASON INSPECTION

Is the discharged air cold?
After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air
to be more than 8°C for cooling.
Are the air intake and outlet vanes of the indoor and outdoor side obstructed?
Are the remote control batteries weak?

RECOMMENDED INSPECTION

Usage over several seasons will reduce performance as the unit becomes dirty. A dirty unit may produce foul odors and dust may clog the dehumidifying drainage. Seasonal inspection is recommended in addition to regular cleaning. Consult Shun Hing Electric Service Centre Ltd.,

BEFORE CALLING FOR SERVICE

Before
Check the following points before calling for repairs or service.
If the malfunction persists, please contact Shun Hing Electric Service Centre Ltd.,

Condition 
If the unit is too noisy during operation.
The following sounds are normal during operation:

  • A low humming sound indicating that the unit is operating.
  • A soft clicking sound when the compressor turns on and off.
  • A flowing sound due to the circulation of the refrigerant when the compressor is turned on.
  • A splashing sound indicating condensation in the condenser coil.If you hear other noises, please consult Shun Hing Electric Service Centre Ltd.,

Condition
If the unit does not operate.

  • The main power cord is not plugged in.
  • The main circuit breaker has tripped.
  • Remote control batteries are weak.

Condition 

  • If the unit does not cool properly.
  • The room is too big for the unit’s capacity.
  • The ventilation lever is set to OPEN
  • The air circulation is impeded by curtains or furniture.
  • After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air to be more than 8°C for cooling.

Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]  These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
NOTE:

  1. The enclosure opposing the room side is splash-proof (IPX4).
  2. Do not install this appliance in a laundry room or other locations where water may drip from the ceiling, etc.
  3. If the supply cord is damaged or needs to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

Condition
If water drips off the rear of the unit.

  • Humidity is high.
  • The condensed water is overflowing.
  • To rectify the problem, mount an optional drain pan to the unit.

Condition 
If water drips inside the room.

  • The unit is tilted inward. To rectify this, tilt the unit slightly outward.
  • Mount the optional drain pan if you prefer.

Condition 
The drain pan may be blocked.

  • Squeaking noise during operation,
  • Squeaking noise after shutting down
    (This is due to the expansion or contraction of the host due to temperature changes)

To call Shun Hing Electric Service Centre Ltd.
IMMEDIATELY Turn off the power and contact Shun Hing Electric Service Centre Ltd.
as soon as any of the following events occur.

  • The circuit breaker frequently trips or the fuse blows regularly.
  • If water or foreign objects have accidentally entered the air conditioner.
  • If there is an abnormal sound during operation.

Panasonic Corporation
Website: http://www.panasonic.com

ACXF55-30110
Printed in the Philippines
OFTH0810-00