Honeywell Y6H910RW4013 T6R Smart Thermostat Installation Guide
Honeywell Y6H910RW4013 T6R Smart Thermostat Installation Guide
Turn OFF the power and remove the old thermostat
To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
In case of removing the old thermostat be aware that the existing wiring will no longer be used.
The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources.
Prepare Receiver Box 2 for installation
Before installation of the Receiver Box
Find a suitable location near to the boiler. Leave at least 30cm distance from any metal objects including wallboxes and boiler housing.
Loosen the front screw to remove cover or tighten it when the cover is back in place.
Needed during installation:
- Cable with 2 wires from the boiler to Receiver Box.
- The Receiver Box requires 230V power
Install the Receiver Box
- Wall box or Rear Wiring
Hinge open the terminal block flap to access the cables and wall box screw holes. - Surface wiring
Use the cable clamps to secure the surface wiring. - Replace the cover
Locate the hinges at the top of the cover and wall plate, close the cover and secure with the screw.
Install the T6 thermostat
Choose the appropriate plug.
Place the thermostat on an even, horizontal surface and plug it in.
Complete installation
Turn ON mains power to the Heating Appliance and Receiver Box.
- After power up, SETUP is displayed on the thermostat’s screen.
The LED on the receiver box will blink yellow to indicate the box is in binding mode. On the thermostat press
Set Up and configuration
- Touch
to begin setting up the thermostat. - Select your language.
- Set the clock format, time and date.
- Touch
to finalise setup. ( to setup using the App is currently unsupported)
Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press
In the advanced menu the following settings can be adjusted:
Menu Item | Default | Options |
LANGUAGE | English | 0 = English, 1 = Français, 2 = Español 3 = Deutsch, 4 = Nederlands, 5 = Italiano |
OPENTHERM | – | OpenTherm boiler data when available |
CYCLE RATE | 6 | 3, 6, 9 or 12 |
MINIMUM ON TIME | 1 minute | 1, 2, 3, 4 or 5 minutes |
HEAT RANGE | Min = 5.0ºC Max = 35.0ºC |
Min: 5ºC to 21ºC, Max: 21ºC to 35ºC |
SCHEDULE OPTIONS | Daily | 1 = Daily schedule, 2 = 5+2 days schedule |
OPTIMISE | Opt. start OFF Opt. stop OFF |
Opt. start: 0 = off, 1 = on, 2 = Delayed start Opt. stop: 0 = off, 1 = on |
CLOCK | Format: 24h Time: –:– Date: 01/09/16 | Clock format: 1 = 12h, 2 = 24h Setup time and date |
LOW LOAD CONTROL | ON | 0 = off, 1 = on |
TEMPERATURE OFFSET | 0.0ºC | -1.5 ºC to 1.5ºC |
BINDING | – | Bind , check RF and clear bind. |
RESET | – | Factory, schedule, WiFi and HomeKit reset |
FAILSAFE | OFF | 0 = off, 1 = on |
Wiring Diagrams
- Basic 230V boiler
- Combi boiler
- OpenTherm boiler
* See boiler specifications for correct terminals
For other wiring diagrams visit:
https://hwllhome.co/uk-wiring - Two-port zone valve or S-plan
Customer Support
Need help? For assistance please visit: getconnected.honeywellhome.com
Resideo, 200 Berkshire Place, Winnersh Triangle, Berkshire RG41 5R
Phone: 0300 130 1299
Approvals
Hereby, Pittway Sarl declares that the radio equipment type T6R is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC
RF (868MHz): Receiver Category 2, Max RF Power 25mW, 868–868.6MHz (868.3MHz)
Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHz
ErP: Class V (+3%), (EU) 811/2013
Must be installed by a competent person!
Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive