Honeywell T6R-HW Smart Thermostat Installation Guide

T6R-HW SMART THERMOSTAT

Compatible with Sundial Y- and S-plan stored hot water systems with zone valves. Also compatible with 24-230V on/off appliances such as gas boilers, combi-boilers, and heat pumps.

Need help? For assistance please visit: getconnected.honeywellhome.com Resideo, 200 Berkshire Place, Winnersh Triangle, Berkshire RG41 5R Phone: 0300 130 1299

Approvals

Hereby, Pittway Sarl declares that the radio equipment type T6R-HW is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC

RF (868MHz): Receiver Category 2, Max RF Power 25mW, 868­868.6MHz (868.3MHz)
Wi-Fi (2.4GHz): Max Power 100mW, 2.4­2.458GHz
ErP: Class V (+3%), (EU) 811/2013

Must be installed by a competent person!
Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Turn OFF the power and remove the old thermostat

To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
In case of removing the old thermostat be aware that the existing wiring will no longer be used

The T6R-HW thermostat should not be placed near draughts, in direct sunlight or near heat sources.

WEEE Directive 2012/19/EC
Waste Electrical and Electronic Equipment directive
At the end of the product, life disposes of the packaging and product in a corresponding recycling center. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.

Prepare Receiver Box for installation

Before installation of the
Receiver Box
Find a suitable location near the boiler. Leave at least 30cm distance from any metal objects including wall boxes and boiler
housing.

Loosen the front screw to remove the cover or tighten it when the cover is back in place.

Needed during installation:

  • Cable with 2 wires from the boiler to Receiver Box.
  • The Receiver Box requires 230V power

Install the Receiver Box

Please refer to the wiring diagrams over the page

A) Wall box or Rear Wiring
Hinge open the terminal block flap to access the cables and wall box screw holes.
B) Surface wiring
Use the cable clamps to secure the surface wiring.
C) Replace the cover
Locate the hinges at the top
of the cover and wall plate, close
the cover and secure with the
screw.

Install the T6 thermostat

Choose the appropriate plug.
Place the thermostat on an even, horizontal surface and plug it in.

Complete installation

Turn ON mains power to the Heating Appliance and Receiver Box. No binding is needed, the Receiver Box and Thermostat are pre-bound.

To rebind the units, reset the Receiver box, then press the button for 3 seconds.
The LED on the receiver box will blink yellow to indicate the box is in binding mode. On the thermostat press for 5 seconds to enter the advanced menu. Navigate to Binding, clear the current binding then bind the device again.

Set Up and configuration

1) Touch to begin
setting up the thermostat.
2) Select your language. 3) Set the clock format,
time and date.
4) Touch to finalise setup. ( to setup using the App is currently unsupported)

Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu
press for 5 seconds.
In the advanced menu the following settings can be adjusted:

Menu Item Default Options
LANGUAGE English 0 = English, 1 = Français, 2 = Español
3 = Deutsch, 4 = Nederlands, 5 = Italiano
SYSTEM TYPE Heat+HW Heating only, Heating + Hot Water, Heating + Cooling
OPENTHERM OpenTherm boiler data when available
CYCLE RATE 6 3, 6, 9 or 12
MINIMUM ON TIME 1 minute 1, 2, 3, 4 or 5 minutes
HEAT RANGE Min = 5.0ºC
Max = 35.0ºC
1 = Daily schedule, 2 = 5+2 days schedule
SCHEDULE OPTIONS Daily Min: 5ºC to 21ºC, Max: 21ºC to 35ºC
OPTIMISE Opt. start OFF
Opt. stop OFF
Opt. start: 0 = off, 1 = on, 2 = Delayed start
Opt. stop: 0 = off, 1 = on
CLOCK Format: 24h
Time: –:-Date:
01/09/16
Clock format: 1 = 12h, 2 = 24h
Setup time and date 
LOW LOAD CONTROL ON 0 = off, 1 = on
TEMPERATURE OFFSET 0.0ºC 1.5 ºC to 1.5ºC
BINDING Bind, check RF, and clear bind.
RESET Factory, schedule, WiFi, and HomeKit reset
FAILSAFE OFF 0 = off, 1 = on

Wiring Diagrams

A) Sundial S-plan

B) Sundial Y-plan

C) Combi boiler

D) OpenTherm boiler

For security reasons: Route this wiring through conduit or in the wall so it is not accessible.

For other wiring diagrams visit:

http://www.honeywelluk.com/professional-zone/resource-centre/Wiring-Diagrams/
https://hwllhome.co/uk-wiring

* See boiler specifications for correct terminals