Honeywell Sundial RF2 Pack 3 User Guide

Sundial RF2 Pack 3
Wireless Enabled Programmer and Thermostats (Y9420S2005)

In a stored hot water heating system that has no room thermostat or cylinder thermostat, the existing wiring can be used to provide a Boiler Interlock by fitting Sundial RF2 Pack 3.
The pack contains:

  • A wireless-enabled programmer (ST9420C)
  • A wireless room thermostat (DT92E)
  •  A wireless cylinder thermostat (CS92A).

Communication between the programmer and thermostat, as well as features such as Optimum Start*, Delayed Start** and Optimum Stop***, enable users to save money and energy.

FEATURES

  • Energy-saving Time Proportional and Integral (TPI) control
  • Wireless-enabled upgrade
  • Two-way wireless communication
  • Wireless signal strength indicator
  • Built-in Economy or Comfort programs on ST9420C
  • Line of Text (LoT) display for easy programming on ST9420C
  • ST9420C fits on industry standard backplate
  • ST9420C is a direct replacement for ST9400 and ST6400 models
  • ECO setback function on DT92E
  • Frost protection on DT92E
  • Table-top stand supplied for DT92E
  • CS92A set and controlled by the programmer
  • DT92E and CS92A are both battery-powered – no wiring
  • Boiler Plus compliant for system boilers

OPTIONS

  • Remote Boiler control with wireless relay box (BDR91 supplied separately)
  • Remote Valve control with wireless relay box (BDR91 supplied separately)

* Optimum Start: To save energy, let the controls work out when to come on to suit when you want to be warm. Every day, the boiler will start at the latest possible moment depending on the weather.
** Delayed Start: Once you have programmed your earliest start time, the controls will delay the boiler firing time on warmer days, when it is possible to save energy.
*** Optimum Stop: Saves energy and money by switching off before the normal program time whenever possible.

Installation

Simply remove the old programmer and replace with ST9420C. This enables the wireless thermostat (DT92E) and wireless cylinder thermostat (CS92A) to be added to the system.
The ST9420C, DT92E and CS92A are radio frequency devices and for best performance should be installed in a clear space. Where possible, leave the ST9420C at least 30 cm from any metal objects, including wall boxes, and at least 1 m from any other electrical equipment.
The DT92E is free to be installed in a suitable location where the signal strength is high.
The CS92A wireless transceiver should be located next to the cylinder with its sensor in contact with the metal surface.

Wiring
For full wiring instructions, please refer to the Wiring Guide or download the Honeywell Home Wiring Guide App from the Apple App Store or Google Play Store.

https://itunes.apple.com/gb/app/wiring-guide/id1445695073?mt=8
https://play.google.com/store/apps/details?id=com.phonegap.wiringguide&hl=en_GB

SPECIFICATION

Pack 3
RF Operation Band ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range Typically 30 m in residential building
RF Communication Technology Two way short, high rate transmissions to minimize air time / avoid interference
RF Blocking Immunity Receiver class 2
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C

10 to 90% RH, non-condensing

Standards CE marked
IP Rating IP30
ST9420C
Switch Rating 3(3)A max at 230 VAC
Switch Type 2x Single pole, double-throw (SPDT) relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve Built-in battery maintains factory-set date and time. The backup supercapacitor retains real-time for  more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals with captive cage clamps, accepting two wires each up to 2.5 mm 2
Time Setting Resolution Time of day – 1 minute

Program time changes – 10 minutes

Time Display 24 hour or 12 hour AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
DT92E
Power Supply Two AA-size, 1.5 V alkaline batteries
Temperature Setting Range 5 to 35°C in 0.5°C steps can be limited between 5 and 35°C
OFF Setpoint Temperature 5°C (default) Can be set between 5 and 16°C or turned off
ECO Setpoint Temperature 18°C (default) Can be set between 5 and 35°C (in 1°C steps), for 1 to 24 hours
Temperature Control Accuracy ±0.5 K at 20°C (50% load, 3 K/hr)
CS92A
Power Supply Two AA-size, 1.5 V alkaline batteries
Temperature Setting Range 40 to 85°C
Cable Length 1.5 m between cylinder thermostat and transceiver

For more information heatingcontrols.honeywellhome.com

ErP energy efficiency ratings
The ErP energy efficiency ratings shown in this brochure will provide installers and end-users with the information required to both complete the ErP energy label and assess the benefits of the heating controls to the overall heating system in the property. These ratings apply to room thermostats (including programmable thermostats).
ENR3 0055 UK01 D0419
© 2019 Ademco 1. All rights reserved.
This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws.
Reproduction or improper use without the specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell  International Inc.

Resideo Technologies, Inc.
200 Berkshire Place
Winnersh
Berkshire
RG41 5RD