Sharp FP-J80EU Air Purifier With Humidifying Function Instruction Manual

Home Appliances HIGH-DENSITY 25000*
“Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation.

Air Purifier

Air Purifier
With Humidifying Function
FP-J80EU / FP-J60EU

* The number in this technology mark indicates an approximate number of ions supplied into the air of 1 cm  3, which is measured around the center of a room applicable floor area (at 1.2 m height above the floor) when the product is placed close to a wall at the MED mode setting.

A unique combination of Air Treatment Technologies
Triple Filteration System + Plasmacluster

High-Density Plasmacluster 25000
The higher the PCI density is, the more effective PCI has.

Triple Filtration System
TRAP DUST
Pre-filter traps dust larger than approx 240-micron particles.
DECREASES ODOURS
Deodorizing filter absorbs many common household odors.
REDUCES TINY DUST, POLLEN & MOLD
HEPA filter traps 99.97% of particles as small as 0.3 microns.

Unique Airflow
Powerful air suction and unique airflow quickly and efficiently collect dust and other particles.

Faster airflow at a 20º angle collects dust at lower levels in the room for more effective cleaning.
Plasmacluster can remove static electricity and can thus prevent dust from attaching to walls and other surfaces.

Plasmacluster
By emitting a balance of positive and negative ions, Plasmacluster air treatment is a natural process.
PM2.5 Monitor

  • Inform by lighting PM2.5 monitor when Sensitive Dust sensor detects microscopic dust.
  • Display the value of PM2.5 in 3 digits.

Plasmacluster Ion Spot Mode

  • Recommended when odor and germs adhering to sofa and curtains are concerned.
  • Emits high-density Plasmacluster Ions only in the forward directions.

Thank you for purchasing this SHARP Air Purifier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.

Please read before operating your new Air Purifier

The air purifier draws in room air through the air intake, circulates it through a PreFilter, a Deodorizing Filter, and a HEPA
Filter inside the main unit, and then discharges it through the air outlet.
The HEPA filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the filter and also help absorb odors.
The Deodorizing Filter gradually absorbs odors as they pass through the filter.Some odors absorbed by the filters will break down over time, causing additional odors.
Depending on usage conditions, and especially if the main unit is used in environments significantly more severe than a normal household, these odors may become noticeable sooner than expected. If these odors persist, replace the filters. (page 11)

NOTE

• The air purifier is designed to remove air-suspended dust and odors.
The air purifier is not designed to remove harmful gases such as carbon monoxide contained in cigarette smoke.
The air purifier may not completely remove an odor if the source of the odor is still present.

IMPORTANT SAFETY INSTRUCTIONS

Always follow basic safety precautions when using electrical appliances, including the following:

WARNING – Always observe the following to reduce the risk of electrical shock, fire, or injury: • Read all instructions before using the main unit.

  • Use only a 220 – 240 volt outlet.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Centre, or similarly qualified persons in order to avoid a hazard. Contact the nearest Service Centre for any problems, adjustments, or repairs.
  • Do not repair or disassemble the main unit yourself.
  • Be sure to remove the power plug, before performing maintenance, when removing and attaching and replacing the filter, and when not using it for a long time. Failure to do so can cause a short circuit resulting in electrical shock or fire.
  • Do not use the main unit if the power cord or plug is damaged or if the connection to the wall outlet is loose.
  • Periodically remove dust from the plug.
  • Do not insert fingers or foreign objects into the air intake or air outlet.
  • When removing the power plug, always hold the plug and never pull on the cord. Failure to do so can cause a short circuit resulting in electrical shock or fire.
  • Be careful not to damage the power cord, it may cause electric shock, excess heat, or fires.
  • Do not remove the plug when your hands are wet.
  • Do not place the main unit near or on hot objects, such as stoves or heaters, or where it may come into contact with steam.
  • Do not operate the main unit in rooms where aerosol insecticides are present. Do not operate the main unit in rooms where there is oily residue, incense, sparks from lit cigarettes, or chemical fumes in the air. Do not operate the main unit in places where it may get wet, such as a bathroom.
  • Be cautious when cleaning the main unit. Strong corrosive cleansers can damage the exterior.
  • Do not expose the main unit to water. Doing so can cause a short circuit or electrical shock.
    NOTE – What to do if the main unit interferes with radio or TV reception If the air purifier interferes with radio or television reception, try one or more of the following measures:
  • Adjust or reposition the receiving antenna.
  • Increase the distance between the main unit and the radio or TV.
  • Connect the equipment into an outlet on a circuit different from that of the radio orTV receiver.
  • Consult the dealer or a qualified radio or TV technician.

CAUTIONS CONCERNING OPERATION

  • Do not block the air intake or air outlet.
  • Always operate the main unit in an upright position.
  • Do not move the main unit when it is in operation.
  • When moving the main unit, use the handles on both sides.
  • If the main unit is on easily damaged flooring, an uneven surface, or thick piled carpet, lift it up when moving.
  • Do not operate the main unit without the filters properly installed.
  • Do not wash and reuse the HEPA filter and the Deodorizing filter. Doing so will not improve filter performance and can also cause electric shock or operating malfunctions.
  • Clean the exterior with a soft cloth only. Do not use volatile fluids or detergents. The main unit surface may be damaged or cracked with Benzine, paint thinner or polishing powder. In addition, the sensors may malfunction as a result.
  • Keep the main unit away from water.
  • Do not scrub the Back Panel hard during its maintenance.

INSTALLATION GUIDELINES

  • Avoid locations where the sensors are exposed to direct wind. Doing so can cause the main unit to malfunction.
  • Avoid locations where furniture, fabrics, or other objects can come in contact with the main unit and interfere with the intake and outtake of air.
  •  Avoid locations where the main unit is exposed to condensation or drastic changes in temperature. Appropriate room temperature is between 0 – 35 ºC.
  • Place the main unit on a level and stable surface with sufficient air circulation. When placed on heavy carpet, the main unit may vibrate slightly.
  • Avoid locations that generate grease or oily smoke. Doing so can cause the main unit exterior to crack and the sensors to malfunction.
  • The dust collecting ability of the main unit is effective even when the main unit is as close to 3 cm from the wall,the surrounding walls and floor may get dirty. Please place the main unit at a distance from the wall. The wall directly behind the air outlet may become dirty over time. When using the main unit for an extended period of time at the same location, periodically clean the walls adjacent to it.

FILTER GUIDELINES

• Follow the instructions in this manual for proper filter care and maintenance. (page 11)

PART NAMES

MAIN UNIT

1 Operation Panel
2 Air Outlet (Front / Back)
3 Cleanliness Monitor
4 Front Display
5 Main Unit
6 Handle (2 locations: Left and Right)
7 Front Louver
8 Back Panel (Pre-Filter)
9 Air Inlet
10 Deodorizing Filter
11 HEPA Filter
12 Sensor Filter  Sensor (Internal) Odour / Dust (sensitive)/ Temperature’ / Humidity* (‘ FP-J80EU)
13 Unit* (Plasmacluster Ion Generating Unit)
14 Unit* Holder
15 Unit* Cover
16 Unit* Cleaning Brush
17 Power Cord, Plug

* The Unit refers to Plasmacluster Ion Generating Unit.

(BACK)

OPERATION PANEL

Press the button with “ ” to start.

FRONT DISPLAY

1 Power ON/OFF Button
2 AUTO Button, Indicator Light
3 CLEAN ION SHOWER Button, Indicator Light
4 Plasmacluster Ion SPOT Button, Indicator Light
5 MODE Button, Indicator Light
6 Timer Button (Press 3 sec.) FILTER RESET Button
7 DISPLAY Button (Press 3 sec.) CHILD-LOCK Button
8 Child-Lock Indicator Light
9 Light Sensor
10 PM2.5 Monitor
Indicates the Dust (sensitive) Sensor detects microscopic dust.
11 Dust Monitor
Indicates the Dust (sensitive) Sensor detects usual dust.
12 Odour Monitor
Indicates the Odour Sensor detects odors.
13 Unit Replacement Indicator Light
14 Filter Maintenance Indicator Light
15 ON Timer Indicator Light
16 OFF Timer Indicator Light
17 Plasmacluster Ion Light
18 DISPLAY
• PM2.5 Monitor
19 Cleanliness Monitor Indicates the air purity of the room in 5 levels with color changes.

PREPARATION

Always be sure to remove the power plug from the wall outlet.

FILTER INSTALLATION

  1. Remove the Back Panel.
  2. 2Remove the plastic bag from each filter.
  3. Install the Back Panel.

OPERATION

START / STOP

AUTO MODE
The fan speed is automatically controlled depending on the 3 detections. (Dust (sensitive) / Odour / Light) NOTE
• Front Display, Cleanliness Monitor automatically switches ON and Darker based on room brightness.(When light control is set to “Auto”. (page 9))

CLEAN ION SHOWER MODE

The main unit releases Plasmacluster ions with a strong airflow and collects dust while decreasing static electricity for 10 minutes. After that, the DUST sensor sensitivity is automatically increased and quickly detects impurities, and cleans the air powerfully for 50 minutes.

NOTE

  • When the operation finishes after 60 minutes, the main unit will return to the prior operation mode. It is able to change the other mode during this mode.
  • The Plasmacluster Ion can not be turned “OFF”.

PLASMACLUSTER ION SPOT MODE

Use this mode when you want to remove adhering odour, germs, and other substances from clothes, sofas, and curtains.

NOTE

  • Emits high-density Plasmacluster Ions only in the forward direction.
  • Discharges stronger air for 8 hours. When the operation finishes, the main unit will return to its prior operation mode.
  • The Plasmacluster Ion can not be turned “OFF”.

SELECTING MODE

SLEEP:
The main unit will operate quietly, and the fan speeds automatically switch depending on the number of impurities in the air and room brightness.
The Front Display and Cleanliness Monitor automatically switch darker or OFF based on room brightness.
Room is bright: light is darker
Room is dark: light is OFF

POLLEN:
The DUST SENSOR sensitivity is automatically increased and quickly detects impurities such as dust and pollen and cleans the air powerfully.

ON TIMER

Select the length of time you want.
The Main Unit automatically starts once the selected time passes. 

OFF TIMER
Select the length of time you want.
The Main Unit automatically stops once the selected time is reached.

CHILD LOCK
The operation panel will be locked.

ON CANCELLATION

SELECTING DISPLAY

(with the Main Unit ON)

PLASMACLUSTER ION ON/OFF

When the Plasmacluster function is ON, the Plasmacluster Ion light is on. (page 5)

(with the Main Unit ON)

HOW TO CHANGE VARIOUS SETTINGS

You can change the functions listed in the table below

  1. Turn the Main Unit power OFF.
  2. Select “Function number”.
  3. Select “Setting number”.
  4. Press Power ON/OFF Button to finish the setting.

    Function

    Setting

    Light Control
    You can select the brightness of the Front Display and Cleanliness Monitor.
    Light automatically switches based on room brightness.
    Room brightness

    Front Display and Cleanliness Monitor

    ALL MODE
    (Except SLEEP)
    SLEEP MODE
    Bright ON Darker
    Dark Darker Turn off

    Auto Restart

    If the Main Unit is unplugged or if there is a power failure, the Main Unit will resume operation with the previous settings after power is restored.

    Adjusting Sensor Sensitivity (F3-F5)
    Light Sensor
    Dust (sensitive) Sensor
    Odour Sensor

    * When set to “Turn off”, the “Darker” light illuminates for 8 seconds after operation starts and then the light turns off.

    FILTER MAINTENANCE INDICATOR

    The Filter Maintenance Indicator Light will turn on after approximately 720 hours of operating.

    This is a reminder to perform the maintenance of the back panel (pre-filter).
    After maintenance, reset the Filter Maintenance Indicator Light.

    MAIN UNIT / BACK PANEL (Pre-Filter)

    Wipe with a dry, soft cloth.
    Remove the dust gently with a cleaning tool such as a vacuum cleaner.

    NOTE How to clean hard to remove dirt.

    Back Panel

    1. Add a small amount of neutral detergent to the water and soak for about 10 minutes.
      CAUTION
      Do not apply excessive pressure when scrubbing the back panel.
    2. Rinse off the neutral detergent with clean water.
    3. Completely dry the filter in a well-ventilated area.

    Sensor Filter

    1. Remove the back panel.
    2. Remove the sensor filter.
    3. If the sensor filter is very dirty, wash it with water and dry it thoroughly.

    HEPA FILTER / DEODORIZING FILTER

    Remove the dust on the filters.

    Maintain only the tagged surface. Do not clean up the opposite surface. The filter is fragile, so be careful not to apply too much pressure.

    CAUTION Do not wash the filters. Do not expose to sunlight. (Otherwise, these filters may lose efficacy.)Both surfaces can be maintained. The filter may be broken if being too much power is applied to it, so please handle it with care.

    Some odors absorbed by the filters will break down over time, causing additional odors. Depending on usage conditions, and especially if the Main Unit is used in environments significantly more severe than a normal household, these odors may become noticeable sooner than expected.
    Replace the filter in those cases or if dust is unable to be removed after maintenance.

    LIFE OF FILTERS
    Filter life varies depending on the room environment, usage conditions, and location of the Main Unit.
    The lifespan of the HEPA filter and Deodorizing filter and replacement suggestions are based on purifying a room in which 5 cigarettes are smoked per day and the Main Unit’s dust collection and deodorizing performance have declined to half the level of a new filter.
    We recommend replacing the filter more frequently if the Main Unit is used in conditions significantly more severe (PM2.5 etc.,) than a normal household.

    • HEPA Filter:
      About 10 years after opening
    • Deodorizing Filter:
      About 10 years after opening

    REPLACEMENT
    Consult your dealer when purchasing a replacement filter.

    Disposing of filters
    Dispose of used filters according to local laws and regulations.

    HEPA Filter material:

    • Polypropylene
    • Polyethylene

    Deodorizing Filter material:

    • Polypropylene
    • Polyester
    • Activated carbon

    Plasmacluster Ion Generating Unit 1

    1. Remove the unit cover, and pull out the unitholder.
    2. Remove dust from the electrode section.
    3. Insert the unit holder in the Main Unit, and install the unit cover.

    CAUTION

    • Do not clean with anything other than the unit cleaning brush. Doing so could lead to failures in the unit.
    • A bent electrode could be cut off and dropped during the cleaning process, but it will not change the performance.
    • Do not touch the electrode directly. Doing so could lead to pain/itching.
    • Do not transform the electrode section. Doing so can damage it.
    • Do not touch the connection terminals. Doing so can damage them.

    Plasmacluster Ion Generating Unit 2

    UNIT REPLACEMENT INDICATOR
    When the total operation time exceeds 17,500 hours, the Unit Replacement indicator will flash to indicate that the Plasmacluster Ion Generating Unit seeds replacement.

    Operating time

    17,500 hours
    Flash slowly

    Replace the Plasmacluster Ion Generating Unit

    19,000 hoursFlash quickly

    Stop the emission of the Plasmacluster ions.

    * The replacement time is not related to the selected operation mode.

    REPLACEMENT
    Consult your dealer when purchasing a replacement Plasmacluster
    Ion Generating Unit.
    Model: IZ-C90MEU Remove the claw of unitholder (1 ), and remove the Plasmacluster Ion Generating Unit (2).

    Disposing of Plasmacluster Ion Generating Unit
    Dispose of used Plasmacluster Ion Generating Unit according to local laws and regulations. material: • Polybutylene terephthalate • electronic parts

    TROUBLESHOOTING

    Before calling for service, please review the list below, since the problem may not be the product malfunction.

    Odour and smoke persist.
    • Check the filters. If they appear to be extremely dirty, clean or replace them.
    • Check if the plastic bag is removed from the filter. (Page 6)
    The Cleanliness Monitor is blue even when the air is not clean.
    • The air may have been dirty when the main unit was plugged in. Unplug the main unit, wait one minute, and then plug the main unit in again.
    The Cleanliness Monitor light is red even when the air is clean.
    • Dirty or clogged dust (sensitive) sensor openings interfere with sensor operation. Gently clean the sensor filter or the back panel.
    The Main Unit makes a clicking or ticking sound.
    • The main unit may make clicking or ticking sounds when it is generating ions.
    Air discharged from the Main Unit has an odor.
    • Check to see if the filters are extremely dirty.
    • Clean or replace the filters.
    The Main Unit does not operate when cigarette smoke is in the air.
    • Make sure the Main Unit is installed in a location in which the sensors can detect cigarette smoke.
    • Check to see if the dust (sensitive) sensor openings are blocked or clogged. If they are blocked or clogged, clean the sensor filter or the back panel.
    Smell from a new filter.
    • Immediately after removing the plastic bag, a slight odor may occur. This odor is not harmful to filter performance or human exposure.
    The FILTER Maintenance Indicator light is on.
    • Whenever after performing maintenance of the filters, connect the power cord to an outlet and then touch the Filter Reset Button. (page 10)
    The Front Display is turned off.
    • When Light control is set to “Turn off”, the light is always off. If you do not want the light to be off, set Light control to “Auto” or “Darker” setting. (page 9)
    The Cleanliness Monitor changes color frequently.
    • The Cleanliness Monitor automatically changes color when the dust (sensitive) sensor and odor sensor detect impurities. If you are concerned about the change, you can change sensor sensitivity. (page 9)
    The Main Unit’s Display does not match the weather report or another hygrometer or thermometer in the room.
    • Outdoor and indoor as well as the home environment (the volume of traffic nearby, number of stories in-home, etc.) may cause a reading different than those data.
    • There is a difference in the level within the same room.

    ERROR DISPLAY

    The concentration of Plasmacluster ion is descending.
    Maintain the Plasmacluster Ion Generating
    Unit (electrode section).
    Is the Plasmacluster Ion Generating Unit inserted properly?
    Pull out the Plasmacluster Ion Generating Unit and insert it to the end again, and then
    carry out the operation again.
    • Unplug the Main Unit, wait one minute, and then plug the Main Unit in again.

    SPECIFICATIONS

    Model

    FP-J80EU

    FP-J60EU

    Power supply 220 – 240 V 50 – 60 Hz
    Fan Speed Adjustment MAX i       MED LOW MAX MED LOW
    Fan Speed (m3/hour) 480 288 60 396 222 60
    Noise Level (dBA) 47 45 15 43 40 15
    Rated Power (W) 48 28 i           4.0 38            i 18 3.6
    Standby Power (W) 1.3 1.2
    Recommended Room Size (m2) *1 – 62 – 48
    High density Plasmacluster ion
    recommended room size (m2) .2
    – 35 – 26
    Cord Length (m) 2 0
    Dimensions (mm) 416 (W) x 291 (D) x 728 (H)
    Weight (kg) 10.6 10.0

    *1 • The recommended room size is appropriate for operating the main unit of maximum fan speed.
    • The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes. (JEM1467)
    *2 • Room size in which approximately 25000 ions per cubic centimeter can be measured in the center of the room when the main unit is placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the floor.

    Standby Power
    When the main unit’s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical circuits. To conserve energy, unplug the power cord when the main unit is not in use

    Attention: Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products.

    A. Information on Disposal for Users (private households)

    1. In the European Union
      IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE!
      Used electrical and electronic equipment should always be collected and treated separately in accordance with local law.
      The separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing final disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available.
      If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal.
      ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES;
      FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law.
      The symbol shown above appears on electrical and electronic equipment (or the packaging) to remind the users of this.
      Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment. Return is free of charge.
      If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP  dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local
      collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.
    2. In other Countries outside the EU
      If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
      For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch.

    B. Information on Disposal for Business Users.

    1. In the European Union
      If the product is used for business purposes and you want to discard it:
      Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
      For Spain: Please contact the established collection system or your local authority for take-back of your used products.
    2. In other Countries outside the EU
      If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.

    SHARP CORPORATION

    Visit our website:
    www.sharphomeappliances.com
    Or contact us:

    Printed in Thailand TINS-B270KKRZ 19M – 1