Technical specifications
The technical and environmental specifications of your system are outlined in this section.
System dimensions
This section describes the physical dimensions of the system.
Figure 1. System dimensions of PowerEdge R740xd system
Table 1. Dimensions
System | Xa | Xb | Y | Za (with bezel) | Za (without bezel) | Zb | Zc |
PowerEdge R740xd | 482.0 mm (18.98 inches) |
434.0 mm (17.09 inches) |
86.8 mm (5.42 inches) | 35.84 mm (1.41 inches) | 22.0 mm (0.87 inches) | 678.8 mm (26.72 inches) | 715.5 mm (28.17inches) |
Chassis weight
Table 2. Chassis weight
System | Maximum weight (with all drives/SSDs) |
2.5 inch drive systems | 28.1 kg (61.95 lb) |
5.5 inch drive systems | 35.1 kg (72.91 lb) |
Processor specifications
The PowerEdge R740xd system supports up to two Intel xeon Processor Scalable Family processors, up to 28 cores per processor.
NOTE: Processor sockets are not hot pluggable
Supported operating systems
The PowerEdge R740xd supports the following operating systems: Canonical Ubuntu LTS
Citrix XenServer
Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux
SUSE Linux Enterprise Server VMware ESXi
NOTE: For more information, go to video/support
PSU specifications
The PowerEdge R740xd system supports up to two AC or DC power supply units (PSUs).
Table 3. PSU specifications
PSU | Class | Heat dissipation (maximum) | Frequenc y | Voltage | High line 2O0v240 V | Low line 100- 140 V | DC | Current |
495 W AC | Platinum | 1908 BTU/hr | /60 H. | 100—240 V AC, autoranging | 495 W | 495 W | NA | 6.5 A—5 A |
750 W AC | Platinum | 2891 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging | 750 W | 750 W | NA | 10 A—5 A |
750 W AC | Titanium | 2843 BTU/hr | 50/60 Hz | 200—240 V AC, atoranging | 750 W | NA | 5 A | |
750 W Mixed Mode uvDc (for China only) |
Platinum | 2891 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging | 750 W | 750 W | NA | 10 A—5 A |
Platinum | 2891 BTU/hr | N/A | 240 V DC, autoranging | NA | NA | 750W | 4.5 A | |
750 W Mixed Mode | Platinum | 2891 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging | 750 W | 750 W | NA | 10 A—5 A |
Platinum(F or China only) | 2891 BTU/hr | N/A | 240 V DC, autoranging | NA | NA | 750 W | 5 A | |
1100 W AC | Platinum | 4100 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging | 1100 W | 1050 W | 12 A—6.5 A | |
1100 W DC | N/A | 4416 BTU/hr | N/A | —(48 V to —60 V) DC, autoranging | NA | NA | 400 W | 32 A |
1100 W Mixed Mode HVDC (for China and Japan only) | Platinum | 4100 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging | 1100 W | 1050 W | 12 A—6.5 A | |
N/A | 4100 BTU/hr | N/A | 200—580 V DC, autoranging | NA | NA | 1100 W | 6.4 A—5.2 A | |
1600 W AC | Platinum | 6000 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging | 1600 W | 800 W | NA | 10 A |
Table 3. PSU specifications (continued)
PSU | Class | Heat dissipation (maximum) | Frequenc y | Voltage | High line 200v240 V | Low line 100— 140 V | DC | Current |
2000 W AC | Platinum | 7500 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging |
2000 W | 1000 W | NA | 11.5 A |
2400 W AC | Platinum | 9000 BTU/hr | 50/60 Hz | 100—240 V AC, autoranging |
2400 W | 1400 W | NA | 16 A |
System battery specifications
The PowerEdge R740xd system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion bus specifications
The PowerEdge R740xd system supports up to eight PCI express (PCIe) generation 3 expansion cards that can be installed on the system board using expansion card risers. The following table provides detailed information about the expansion card riser specifications:
Table 4. Expansion card riser configurations
Expansion
card riser |
PCle slots on the riser | Height | Length | Link |
Riser 1A | Slot 1 | Full Height | Full Length | x16 |
Slot 3 | Full Height | Half Length | x16 | |
Riser 1B | SIot1 | Full Height | Full Length | x8 |
Slot 2 | Full Height | Full Length | x8 | |
Slot 3 | Full Height | Half Length | x8 | |
Riser 1D | Slot 1 | Full Height | Full Length | x16 |
Slot 2 | Full Height | Full Length | x8 | |
Slot 3 | Full Height | Half Length | x8 | |
Riser 2A | Slot4 | Full Height | Full Length | x16 |
Slot S | Full Height | Full Length | x8 | |
Slot 6 | Low Profile | Half Length | x8 | |
Riser 2B | Slot4 | Low Profile | Half Length | x8 |
Riser 2C | Slot4 | Low Profile | Half Length | x16 |
Riser EA | Sot7 | Full Height | Full Length | x8 |
Sot8 | Full Height | Full Length | x16 |
Table 5. Expansion card riser specifications
Riser configuration and supported risers | Slot description | PCle slots on riser 1 (Height and length) | Processor connection | PCIe slots on riser 2 (Height and length) | Processor connection | PCIe slots on riser 3 (Height and length) | Processor connection |
Riser configuration 0 with or without rear storage (No riser) | No PCIe slots (only rear storage) | N/A | N/A | N/A | N/A | N/A | N/A |
Riser configuration 1 with or without rear storage (1B+2B) | Four x8 slots and rear storage | Slot 1: x8 full— height, full length | Processor 1 | Slot 4: x8 low prof ile, half length | Processor 1 | N/A | N/A |
Slot 2: x8 full— height, full length | Processor 1 | ||||||
Slot 5: x8 full— height, half length | Processor 1 | ||||||
Riser configuration 2 with or without rear storage (1B+2C) | Three x8 and one x16 slots and rear storage | Slot 1: x8 full— height, full length | Processor 1 | Slot 4: x16′ profile, half lenpth | Processor 2 | N/A | N/A |
Slot 2: x8 full— height, full lenpth | Processor 1 | ||||||
Slot 3: x8 full— height, half lenpth | Processor 1 | ||||||
Riser configuration 3 (1A+2A) | Two x8 and three x16 slots | Slot 1: x16 full— height, full lenpth | Processor 1 | Slot 4: x16 full— height, full length | Processor 2 | N/A | N/A |
N/A | N/A | Slot 5: x8 full— height, full length | Processor 2 | ||||
Slot 5: x16 full— height, half length | Processor 1 | Slot 6: x8 low prof ile, half length | Processor 1 | ||||
Riser confguration 4 (1A+ 2A+3A) | Three x8 and four x16 slots | Slot 1: x16 full— height, full length | Processor 1 | Slot 4: x16 full— height, full length | Processor 2 | Slot 7: x8 full— height, full length | Processor 2 |
N/A | N/A | Slot 5: x8 full- height, full length | Processor 2 | Slot 8: x16 full- height, full length | Processor 2 | ||
Slot 5: x16 full- height, half length | Processor 1 | Slot 6: x8 low profile, half length | Processor 1 | ||||
Riser configuration 5 (1B+2A+EA) | Six x8 and two x16 slots | Slot 1: x8 full— height, full lenpth | Processor 1 | Slot 4: x16 full— heipht, full length | Processor 2 | Slot 7: x8 full— heipht, full lenpth | Processor 2 |
Slot 2: x8 full— height, full lenpth | Processor 1 | Slot 5: x8 full— heipht, full length | Processor 2 | Slot 8: x16 full— heipht, full lenpth | Processor 2 | ||
Slot 3: x8 full— height, half lenpth | Processor 1 | Slot 6: x8 low profile, half lenpth | Processor 1 |
- Riser slots are not hot pluggable.
- Internal cable connectors are not hot pluggable.
Memory specifications
Table 6. Memory specifications
Memory module sockets |
DIMM type | DIMM rank | DIMM capacity |
Single processor | Dual processors | ||
Minimum RAM | Maximum RAM | Minimum RAM | Maximum RAM | ||||
Twenty four 288-pins | LRDIMM |
Octa rank | 128 GB | 128 GB | 1.5 TB | 256 GB | 3 TB |
Quad rank | 64 GB | 64 GB | 768 GB | 128 GB | 1.5 TB | ||
RDIMM | Single rank | 8 GB | 8 GB | 96 GB | 16 GB | 192 GB | |
Dual rank | 16 GB | 16 GB | 192 GB | 32 GB | 384 GB | ||
Dual rank | 52 GB | 52 GB | 384 GB | 64 GB | 768 GB | ||
Dual rank | 64 GB | 64 GB | 768 GB | 128 GB | 1556 GB | ||
NVDIMM — N | Single rank | 16 GB | Not supported with single processor | Not supported with single processor | RDIMM: 192 GB | RDIMM: 384 GB | |
NVDIMM —N: 16 GB | NVDIMM —N: 192 GB | ||||||
DCPMM | NA | 128 GB | RDIMM: 192GB | RDIMM: 384 GB | RDIMM: 384 GB | LRDIMM: 1536 GB | |
DCPMM: 128 GB | DCPMM: 128 GB | DCPMM: 1556 GB | DCPMM: 1556 GB | ||||
NA | 256 GB | NA | NA | RDIMM: 192 GB | LRDIMM: 1536 GB |
Table 6. Memory specifications (continued)
Memory module sockets |
DIMM type | DIMM rank | DIMM capacity | Single processor |
Dual processors | ||
Minimum RAM | Maximum RAM | Minimum RAM | Maximum RAM | ||||
NA | NA | DCPMM: 2048 GB | DCPMM: 5072 GB | ||||
NA | 512 GB | NA | NA | RDIMM: 584 GB | RDIMM: 1556 GB | ||
NA | NA | DCPMM: 4096 GB | DCPMM: 6144 GB |
Storage controller specifications
The PowerEdge R740xd system supports:
- Internal storage controller cards: PowerEdge RAID Controller (PERC) H330, PERC H730P, PERC H740P, HBA330, S140, and Boot Optimized Server Storage (BOSS-S1).
The BOSS card is a simple RAID solution card designed specifically for booting a server’s operating system. The card supports up to two 6 Gbps M.2 SATA drives. The BOSS adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available only in the low-profile and half-height form factor. - External storage controller cards: PERC H840 and 12Gbps SAS HBA.
NOTE: Mini-PERC socket is not hot pluggable.
Drive specifications
Drives
The PowerEdge R740XD system supports SAS, SATA, Nearline SAS hard drives/SSDs, or NVMe drives.
Table 7. Supported drive options for the PowerEdge R740XD system
Configuration | Description |
12 drives system | Up to 12 5.5 inch (SAS, SATA, or Near line SAS) front accessible drives in slots 0—11 |
Table 7. Supported drive options for the PowerEdge R740XD system (continued)
Configuration | Description |
14 drives system | Up to 12 3.5 inch (SAS, SATA, or Nearline SAS) front accessible drives in slots 0—11 and up to two 5.5 inch (SAS, SATA or Near line SAS) rear accessible drives in slots 12—IN |
16 drives system | Up to 12 5.5 inch (SAS, SATA, or Nearline SAS) front accessible drives in slots 0—11 and up to four 2.5 inch (SAS, SATA or Nearline SAS) rear accessible drives in slots 12—15 |
18 drives system | Up to 12 5.5 inch (SAS, SATA, or Nearline SAS) front accessible drives in slots 0—11, up to four 3.5 inch (SAS, SATA, or Nearline SAS) mid drives in slots 14—17, and up to two 3.5 inch (SAS, SATA or Nearline SAS) rear accessible drives in slots 12—13 |
20 drives system | Up to 12 5.5 inch (SAS, SATA, or Near line SAS) front accessible drives in slots 0—11, up to four 3.5 inch (SAS, SATA, or Near line SAS) mid drives in slots 16—19, and up to four 2.5 inch (SAS, SATA or Near line SAS) rear accessible drives in slots 12—15 |
24 drives system | Up to 24 2.5 inch (SAS, SSD, or NVMe) front accessible drives in slots 0—23 |
24 drives system | Up to 12 2.5 inch (SAS, SSD) front accessible drives in slots 0—11 and up to 12 2.5 inch SATA/SAS/NVMe drives in 12 universal slots 12—23 |
24 drives system | Up to 24 2.5 inch NVMe drives in bay 1 (slots 0—11) and bay 2 (slots 0—11) |
24 drives system | Up to 24 2.5 inch NVME drives or up to eight 2.5 inch (SAS or SATA} drives in bay 1 (slots 0—7) with NVMe drives in other slots |
28 drives system | Up to 24 2.5 inch (SAS, SSD, or NVMe) front accessible drives in slots 0—23 and up to four 2.5 inch (SAS, SSD, or NVMe} rear accessible drives in slots 24—27. |
52 drives system | Up to 24 2.5 inch (SAS, SSD, or NVMe) front accessible drives in slots 0—23, up to four 2.5 inch (SAS, SSD, or NVMe) mid drives in slots 28—51, and up to four 2.5 inch (SAS, SSD, or NVMe) rear accessible drives in slots 24—27 |
Ports and connectors specifications
USB ports
The PowerEdge R740xd system supports:
- Two USB 0-compliant ports on the front of the system
- One internal USB 0-compliant port
- One micro USB 0-compliant port in the front of the system for iDRAC Direct
- Two USB 0-compliant ports on the back of the system
NIC ports
The PowerEdge R740xd system supports up to four Network Interface Controller (NIC) ports that are integrated on the network daughter card (NDC), and are available in the following configurations:
- Four RJ-45 ports that support 10, 100 and 1000 Mbps
- Four RJ-45 ports that support 100 M, 1 G and 10 Gbps
- Four RJ-45 ports, where two ports support maximum of 10 G and the other two ports maximum of 1 G
- Two RJ-45 ports that support up to 1 Gbps and 2 SFP+ ports that support up to 10 Gbps
- Four SFP+ ports that support up to 10 Gbps
- Two SFP28 ports that support up to 25 Gbps
VGA ports
The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The PowerEdge R740xd system supports two 15-pin VGA ports on the front and back panels.
Serial connector
The PowerEdge R740xd system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.
Internal Dual SD Module or vFlash card
The PowerEdge R740xd system supports Internal Dual SD module (IDSDM) and vFlash card. In 14th generation of PowerEdge servers, IDSDM and vFlash card are combined into a single card module, and are available in these configurations:
- vFlash or
- IDSDM or
- vFlash and IDSDM
The IDSDM/vFlash card sits in the back of the system, in a Dell-proprietary slot. IDSDM/vFlash card supports three micro SD cards (two cards for IDSDM and one card for vFlash). Micro SD cards capacity for IDSDM are 16/32/64 GB while for vFlash the microSD card capacity is 16 GB. NOTE: IDSDM and vFlash slot is not hot pluggable.
Video specifications
The PowerEdge R740xd system supports integrated Matrox G200eW3 graphics controller with 16 MB of video frame buffer.
Table 8. Supported video resolution options
Resolution | Refresh rate (Hz) | Color depth (bits) |
1024 x 768 | 60 | 8, 16, 32 |
1280 x 800 | 60 | 8, 16, 32 |
1280 x 1024 | 60 | 8, 16, 32 |
1360 x 768 | 60 | 8, 16, 32 |
1440 x 900 | 60 | 8, 16, 32 |
1600 x 900 | 60 | 8, 16, 32 |
1600 x 1200 | 60 | 8, 16, 32 |
1680 x 1050 | 60 | 8, 16, 52 |
1920 x 1080 | 60 | 8, 16, 52 |
1920 x 1200 | 60 | 8, 16, 52 |
Environmental specifications
located with the Manuals & Documents on www.dell.com/poweredgemanuals.
Table 9. Temperature specifications
Temperature | Specifications |
Storage | —4 0° C to 65 OC (—40 O F to 14 9 F) |
Continuous operation (for altitude less than 950 m or 5117 ft) | 10°C to 55°C (50°F to 95° F) with no direct sunlight on the equipment. |
Maximum temperature gradient (operating and storage) | 20°C/h (68°F/h) |
Table 10. Relative humidity specifications
Relative humidity | Specifications |
Storage | 5% to 95% RH with 55°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
Operating | 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. |
Table 11. M aximum vibration specifications
Maximum vibration | Specifications |
Operating | 0.26 Gig, at 5 Hz to 350 Hz (all three axes). |
Storage | 1.88 Gig, at 10 Hz to 500 Hz for 15 min (all six sides tested). |
Table 12. Maximum shock specifications
Maximum shock | Specifications |
Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. |
Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
Table 13. Maximum altitude specifications
Maximum altitude | Specifications |
Operating | 5048 m (10,000 ft} |
Storage | 12,000 m (59,570 ft) |
Table 14. Operating temperature de-rating specifications
Operating temperature de-rating | Specifications |
Up to 35°C (95 F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (5,117 ft). |
55°C to 40°C (95°F to 104 F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (5,117 ft). |
40°C to 45°C (104 F to 115° F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (5,117 ft). |
Standard operating temperature
Table 15. Standard operating temperature specifications
Standard operating temperature | Specifications |
Continuous operation (for altitude less than 950 m or 5117 ft) | 10°C to 55°C (50°F to 95° F) with no direct sunlight on the equipment. |
Humidity percentage range | 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point. |
Expanded operating temperature
Table 16. Expanded operating ternperature specifications
Expanded operating temperature | Specifications |
Continuous operation | 5°C to 40°C at 5% to 85% RH with 29°C dew point. For temperatures between 55°C to 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). |
1% of annual operating hours | —5°C to 45°C at 5% to 90% RH with 29°C dew point. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). |
Expanded operating temperature restrictions
- 128 GB LRDIMM is not supported for FAC.
- Do not perform a cold startup below 5°C.
- The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
- 150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
- Redundant power supply unit is required.
- Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
- PCIe SSD is not supported.
- NVDIMM-Ns are not supported.
- DCPMMs are not supported.
- Mid drive tray is not supported.
- Rear storage devices or drives are not supported.
- GPU is not supported.
- Tape backup unit is not supported.
Thermal restrictions
Following table lists the configuration required for efficient cooling.
Table 17. Thermal restrictions configuration
Configuratio n | Number of processo rs |
Heatsink | Processor/DI MM blank | DIMM
blanks |
Type of air shroud | Fan |
PowerEdge R740xd | One 1U standard heat sink for CPU s 125 W |
Required |
Not required |
Standard |
Four standard fans and one blank to cover two fan slots | |
One 2U standard heat sink for CPU > 125 W | ||||||
PowerEdge R740xd |
2 |
Two 1U standard heat sink for CPU s 125 W |
Not required |
Not required |
Standard |
Six standard fans |
Two 2U standard heat sink for CPU > 125 W | ||||||
PowerEdge R740xd with mid bay | 1 | One 1U high performance heat sink | Required | Required | Not required | Six hiph performance fans |
PowerEdge R740xd with mid bay | 2 | Two 1U hiph performance heat sink | Not required | Required | Not required | Six hiph performance fans |
PowerEdge R740xd with GPU | 2 | Two 1U high performance heat sink | Not required | Not required | GPU air shroud | Six high performance fans |
PowerEdge R740xd with rear drive only |
1 |
One 1U standard heat sink for CPU s 125 W |
Required |
Not required |
Standard |
Six high performance fans |
One 2U standard heat sink for CPU > 125 W | ||||||
PowerEdge R740xd with rear drive only |
2 |
Two 1U standard heat sink for CPU s 125 W |
Required |
Not required |
Standard |
Six high-performance fans |
Two 2U standard heat sink for CPU > 125 W |
Ambient temperature limitations
The following table lists configurations that require ambient temperature less than 35°C.
Table 18. Configuration based ambient temperature restrictions
System | Backplane | Processor Thermal Design Power (TDP) | Processor heat sink | Fan type | GPU | Ambient restriction |
PowerEdge | 12 x 5.5 inch | N/A | 25’C | |||
R740xd | SAS/SATA + 4 x 5.5 inch + 2 x 5.5 inch |
150 W/8 core, US W/12 core, 200 W, 205 W | 1U high performance |
High performance fan | ||
24 x 2.5 inch | N/A | 25’C | ||||
SAS/SATA + 4 x |
Table 18. Configuration based ambient temperature restrictions (continued)
System | Backplane | Processor Thermal Design Power (TDP) | Processor heat sink | Fan type | GPU | Ambient restriction |
2.5 inch + 4 x 2.5 inch | ||||||
24 x 2.5 inch SAS/SATA | AH | 30OC | ||||
24 x NVMe | All except V100 32 GB | 30°C | ||||
22 x NVMe | V100 32 GB | 25°C |
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 19. Particulate contamination specifications
Particulate contamination | Specifications |
Air filtration | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. |
Conductive dust | Air must be free of conductive dust, zinc whiskers, or other conductive particles. |
Corrosive dust | ● Air must be free of corrosive dust. ● Residual dust present in the air must have a deliquescent point less than 60% relative humidity. |
Table 20. Gaseous contamination specifications
Gaseous contamination | Specifications |
Copper coupon corrosion rate | <300 A/month per Class G1 as defined by ANSI/ISA71.04-2013. |
Silver coupon corrosion rate | <200 A/month as defined by ANSI/ISA71.04-2013. |