Dell EMC PowerEdge R740xd Rack Server Owner’s Manual

Dell EMC PowerEdge R740xd
Technical Specifications

Regulatory Model: E38S Series
Regulatory Type: E38S001
July 2020
Rev. A05

Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

© 2016 – 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

Technical specifications

The technical and environmental specifications of your system are outlined in this section.

System dimensions

This section describes the physical dimensions of the system.

Figure 1. System dimensions of PowerEdge R740xd system

Table 1. Dimensions

System Xa Xb Y Za (with bezel) Za (without bezel) Zb

Zc

PowerEdge R740xd 482.0 mm
(18.98 inches)
434.0 mm
(17.09 inches)
86.8 mm (5.42 inches) 35.84 mm (1.41 inches) 22.0 mm (0.87 inches) 678.8 mm (26.72 inches) 715.5 mm (28.17inches)

Chassis weight

Table 2. Chassis weight

System Maximum weight (with all drives/SSDs)
2.5 inch drive systems 28.1 kg (61.95 lb)
5.5 inch drive systems 35.1 kg (72.91 lb)

Processor specifications

The PowerEdge R740xd system supports up to two Intel xeon Processor Scalable Family processors, up to 28 cores per processor.
NOTE: Processor sockets are not hot pluggable

Supported operating systems

The PowerEdge R740xd supports the following operating systems: Canonical Ubuntu LTS
Citrix XenServer
Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux
SUSE Linux Enterprise Server VMware ESXi

NOTE: For more information, go to video/support

PSU specifications

The PowerEdge R740xd system supports up to two AC or DC power supply units (PSUs).
Table 3. PSU specifications

PSU Class Heat dissipation (maximum) Frequenc y Voltage High line 2O0v240 V Low line 100- 140 V DC Current
495 W AC Platinum 1908 BTU/hr /60 H. 100—240 V AC, autoranging 495 W 495 W NA 6.5 A—5 A
750 W AC Platinum 2891 BTU/hr 50/60 Hz 100—240 V AC, autoranging 750 W 750 W NA 10 A—5 A
750 W AC Titanium 2843 BTU/hr 50/60 Hz 200—240 V AC, atoranging 750 W NA 5 A
750 W
Mixed Mode uvDc (for China only)
Platinum 2891 BTU/hr 50/60 Hz 100—240 V AC, autoranging 750 W 750 W NA 10 A—5 A
Platinum 2891 BTU/hr N/A 240 V DC, autoranging NA NA 750W 4.5 A
750 W Mixed Mode Platinum 2891 BTU/hr 50/60 Hz 100—240 V AC, autoranging 750 W 750 W NA 10 A—5 A
Platinum(F or China only) 2891 BTU/hr N/A 240 V DC, autoranging NA NA 750 W 5 A
1100 W AC Platinum 4100 BTU/hr 50/60 Hz 100—240 V AC, autoranging 1100 W 1050 W 12 A—6.5 A
1100 W DC N/A 4416 BTU/hr N/A —(48 V to —60 V) DC, autoranging NA NA 400 W 32 A
1100 W Mixed Mode HVDC (for China and Japan only) Platinum 4100 BTU/hr 50/60 Hz 100—240 V AC, autoranging 1100 W 1050 W 12 A—6.5 A
N/A 4100 BTU/hr N/A 200—580 V DC, autoranging NA NA 1100 W 6.4 A—5.2 A
1600 W AC Platinum 6000 BTU/hr 50/60 Hz 100—240 V AC, autoranging 1600 W 800 W NA 10 A

Table 3. PSU specifications (continued)

PSU Class Heat dissipation (maximum) Frequenc y Voltage High line 200v240 V Low line 100— 140 V DC Current
2000 W AC Platinum 7500 BTU/hr 50/60 Hz 100—240 V AC,
autoranging
2000 W 1000 W NA 11.5 A
2400 W AC Platinum 9000 BTU/hr 50/60 Hz 100—240 V AC,
autoranging
2400 W 1400 W NA 16 A

NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.
NOTE: PSUs rated for 1100 W Mixed Mode HVDC or 1100 W AC and higher require high-line voltage (200–240 V AC) to supply their rated capacity.

System battery specifications

The PowerEdge R740xd system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion bus specifications

The PowerEdge R740xd system supports up to eight PCI express (PCIe) generation 3 expansion cards that can be installed on the system board using expansion card risers. The following table provides detailed information about the expansion card riser specifications:

Table 4. Expansion card riser configurations

Expansion
card riser
PCle slots on the riser Height Length

Link

Riser 1A Slot 1 Full Height Full Length x16
Slot 3 Full Height Half Length x16
Riser 1B SIot1 Full Height Full Length x8
Slot 2 Full Height Full Length x8
Slot 3 Full Height Half Length x8
Riser 1D Slot 1 Full Height Full Length x16
Slot 2 Full Height Full Length x8
Slot 3 Full Height Half Length x8
Riser 2A Slot4 Full Height Full Length x16
Slot S Full Height Full Length x8
Slot 6 Low Profile Half Length x8
Riser 2B Slot4 Low Profile Half Length x8
Riser 2C Slot4 Low Profile Half Length x16
Riser EA Sot7 Full Height Full Length x8
Sot8 Full Height Full Length x16

Table 5. Expansion card riser specifications

Riser configuration and supported risers Slot description PCle slots on riser 1 (Height and length) Processor connection PCIe slots on riser 2 (Height and length) Processor connection PCIe slots on riser 3 (Height and length) Processor connection
Riser configuration 0 with or without rear storage (No riser) No PCIe slots (only rear storage) N/A N/A N/A N/A N/A N/A
Riser configuration 1 with or without rear storage (1B+2B) Four x8 slots and rear storage Slot 1: x8 full— height, full length Processor 1 Slot 4: x8 low prof ile, half length Processor 1 N/A N/A
Slot 2: x8 full— height, full length Processor 1
Slot 5: x8 full— height, half length Processor 1
Riser configuration 2 with or without rear storage (1B+2C) Three x8 and one x16 slots and rear storage Slot 1: x8 full— height, full length Processor 1 Slot 4: x16′ profile, half lenpth Processor 2 N/A N/A
Slot 2: x8 full— height, full lenpth Processor 1
Slot 3: x8 full— height, half lenpth Processor 1
Riser configuration 3 (1A+2A) Two x8 and three x16 slots Slot 1: x16 full— height, full lenpth Processor 1 Slot 4: x16 full— height, full length Processor 2 N/A N/A
N/A N/A Slot 5: x8 full— height, full length Processor 2
Slot 5: x16 full— height, half length Processor 1 Slot 6: x8 low prof ile, half length Processor 1
Riser confguration 4 (1A+ 2A+3A) Three x8 and four x16 slots Slot 1: x16 full— height, full length Processor 1 Slot 4: x16 full— height, full length Processor 2 Slot 7: x8 full— height, full length Processor 2
N/A N/A Slot 5: x8 full- height, full length Processor 2 Slot 8: x16 full- height, full length Processor 2
Slot 5: x16 full- height, half length Processor 1 Slot 6: x8 low profile, half length Processor 1
Riser configuration 5 (1B+2A+EA) Six x8 and two x16 slots Slot 1: x8 full— height, full lenpth Processor 1 Slot 4: x16 full— heipht, full length Processor 2 Slot 7: x8 full— heipht, full lenpth Processor 2
Slot 2: x8 full— height, full lenpth Processor 1 Slot 5: x8 full— heipht, full length Processor 2 Slot 8: x16 full— heipht, full lenpth Processor 2
Slot 3: x8 full— height, half lenpth Processor 1 Slot 6: x8 low profile, half lenpth Processor 1

NOTE:

  • Riser slots are not hot pluggable.
  • Internal cable connectors are not hot pluggable.

Memory specifications

Table 6. Memory specifications

Memory module sockets

DIMM type DIMM rank

DIMM capacity

Single processor

Dual processors

Minimum RAM Maximum RAM Minimum RAM

Maximum RAM

Twenty four 288-pins  

LRDIMM

Octa rank 128 GB 128 GB 1.5 TB 256 GB 3 TB
Quad rank 64 GB 64 GB 768 GB 128 GB 1.5 TB
RDIMM Single rank 8 GB 8 GB 96 GB 16 GB 192 GB
Dual rank 16 GB 16 GB 192 GB 32 GB 384 GB
Dual rank 52 GB 52 GB 384 GB 64 GB 768 GB
Dual rank 64 GB 64 GB 768 GB 128 GB 1556 GB
NVDIMM — N Single rank 16 GB Not supported with single processor Not supported with single processor RDIMM: 192 GB RDIMM: 384 GB
NVDIMM —N: 16 GB NVDIMM —N: 192 GB
DCPMM NA 128 GB RDIMM: 192GB RDIMM: 384 GB RDIMM: 384 GB LRDIMM: 1536 GB
DCPMM: 128 GB DCPMM: 128 GB DCPMM: 1556 GB DCPMM: 1556 GB
NA 256 GB NA NA RDIMM: 192 GB LRDIMM: 1536 GB

Table 6. Memory specifications (continued)

Memory module sockets

DIMM type DIMM rank DIMM capacity

Single processor

Dual processors

Minimum RAM Maximum RAM Minimum RAM

Maximum RAM

NA NA DCPMM: 2048 GB DCPMM: 5072 GB
NA 512 GB NA NA RDIMM: 584 GB RDIMM: 1556 GB
NA NA DCPMM: 4096 GB DCPMM: 6144 GB

NOTE: 8 GB RDIMMs and NVDIMM-N must not be mixed.
NOTE: 64 GB LRDIMMs, 128 GB LRDIMMs must not be mixed.
NOTE: Minimum of two CPUs are required for any configurations that support NVDIMM-N.
NOTE: DCPMM can be mixed with RDIMMs and LRDIMMs.
NOTE: Mixing of DDR4 DIMM Types (RDIMM, LRDIMM), within channel, integrated memory controller, socket, or across sockets is not supported.
NOTE: x4 and X8 DDR4 DIMM can be mixed within channel.
NOTE: Mix of Intel Data center persistent memory module operating modes (App Direct, Memory Mode) is not supported within socket or across sockets.
NOTE: Memory DIMM slots are not hot pluggable.

Storage controller specifications

The PowerEdge R740xd system supports:

  • Internal storage controller cards: PowerEdge RAID Controller (PERC) H330, PERC H730P, PERC H740P, HBA330, S140, and Boot Optimized Server Storage (BOSS-S1).
    The BOSS card is a simple RAID solution card designed specifically for booting a server’s operating system. The card supports up to two 6 Gbps M.2 SATA drives. The BOSS adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available only in the low-profile and half-height form factor.
  • External storage controller cards: PERC H840 and 12Gbps SAS HBA.
    NOTE: Mini-PERC socket is not hot pluggable.

Drive specifications

Drives

The PowerEdge R740XD system supports SAS, SATA, Nearline SAS hard drives/SSDs, or NVMe drives.
Table 7. Supported drive options for the PowerEdge R740XD system

Configuration Description
12 drives system Up to 12 5.5 inch (SAS, SATA, or Near line SAS) front accessible drives in slots 0—11

Table 7. Supported drive options for the PowerEdge R740XD system (continued)

Configuration Description
14 drives system Up to 12 3.5 inch (SAS, SATA, or Nearline SAS) front accessible drives in slots 0—11 and up to two 5.5 inch (SAS, SATA or Near line SAS) rear accessible drives in slots 12—IN
16 drives system Up to 12 5.5 inch (SAS, SATA, or Nearline SAS) front accessible drives in slots 0—11 and up to four 2.5 inch (SAS, SATA or Nearline SAS) rear accessible drives in slots 12—15
18 drives system Up to 12 5.5 inch (SAS, SATA, or Nearline SAS) front accessible drives in slots 0—11, up to four 3.5 inch (SAS, SATA, or Nearline SAS) mid drives in slots 14—17, and up to two 3.5 inch (SAS, SATA or Nearline SAS) rear accessible drives in slots 12—13
20 drives system Up to 12 5.5 inch (SAS, SATA, or Near line SAS) front accessible drives in slots 0—11, up to four 3.5 inch (SAS, SATA, or Near line SAS) mid drives in slots 16—19, and up to four 2.5 inch (SAS, SATA or Near line SAS) rear accessible drives in slots 12—15
24 drives system Up to 24 2.5 inch (SAS, SSD, or NVMe) front accessible drives in slots 0—23
24 drives system Up to 12 2.5 inch (SAS, SSD) front accessible drives in slots 0—11 and up to 12 2.5 inch SATA/SAS/NVMe drives in 12 universal slots 12—23
24 drives system Up to 24 2.5 inch NVMe drives in bay 1 (slots 0—11) and bay 2 (slots 0—11)
24 drives system Up to 24 2.5 inch NVME drives or up to eight 2.5 inch (SAS or SATA} drives in bay 1 (slots 0—7) with NVMe drives in other slots
28 drives system Up to 24 2.5 inch (SAS, SSD, or NVMe) front accessible drives in slots 0—23 and up to four 2.5 inch (SAS, SSD, or NVMe} rear accessible drives in slots 24—27.
52 drives system Up to 24 2.5 inch (SAS, SSD, or NVMe) front accessible drives in slots 0—23, up to four 2.5 inch (SAS, SSD, or NVMe) mid drives in slots 28—51, and up to four 2.5 inch (SAS, SSD, or NVMe) rear accessible drives in slots 24—27

NOTE: Universal slots are slots that support SAS, SATA hard drives/SSDs, or NVMe drives in the same slot.

Ports and connectors specifications

USB ports

The PowerEdge R740xd system supports:

  • Two USB 0-compliant ports on the front of the system
  • One internal USB 0-compliant port
  • One micro USB 0-compliant port in the front of the system for iDRAC Direct
  • Two USB 0-compliant ports on the back of the system
NIC ports

The PowerEdge R740xd system supports up to four Network Interface Controller (NIC) ports that are integrated on the network daughter card (NDC), and are available in the following configurations:

  • Four RJ-45 ports that support 10, 100 and 1000 Mbps
  • Four RJ-45 ports that support 100 M, 1 G and 10 Gbps
  • Four RJ-45 ports, where two ports support maximum of 10 G and the other two ports maximum of 1 G
  • Two RJ-45 ports that support up to 1 Gbps and 2 SFP+ ports that support up to 10 Gbps
  • Four SFP+ ports that support up to 10 Gbps
  • Two SFP28 ports that support up to 25 Gbps

NOTE: You can install up to eight PCIe add-on NIC cards.
NOTE: NDC slot is not hot pluggable.

VGA ports

The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The PowerEdge R740xd system supports two 15-pin VGA ports on the front and back panels.

NOTE: The VGA ports are not hot pluggable.

Serial connector

The PowerEdge R740xd system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.
NOTE: The Serial port is not hot pluggable.

Internal Dual SD Module or vFlash card

The PowerEdge R740xd system supports Internal Dual SD module (IDSDM) and vFlash card. In 14th generation of PowerEdge servers, IDSDM and vFlash card are combined into a single card module, and are available in these configurations:

  • vFlash or
  • IDSDM or
  • vFlash and IDSDM
    The IDSDM/vFlash card sits in the back of the system, in a Dell-proprietary slot. IDSDM/vFlash card supports three micro SD cards (two cards for IDSDM and one card for vFlash). Micro SD cards capacity for IDSDM are 16/32/64 GB while for vFlash the microSD card capacity is 16 GB.
    NOTE: IDSDM and vFlash slot is not hot pluggable.

Video specifications

The PowerEdge R740xd system supports integrated Matrox G200eW3 graphics controller with 16 MB of video frame buffer.
Table 8. Supported video resolution options

Resolution Refresh rate (Hz)

Color depth (bits)

1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 52
1920 x 1080 60 8, 16, 52
1920 x 1200 60 8, 16, 52

NOTE: 1920 x 1080 and 1920 x 1200 resolutions are only supported in reduced blanking mode.

Environmental specifications

NOTE: For additional information about environmental certifications, please refer to the Product Environmental Datasheet
located with the Manuals & Documents on www.dell.com/poweredgemanuals.
Table 9. Temperature specifications

Temperature Specifications
Storage —4 0° C to 65 OC (—40 O F to 14 9 F)
Continuous operation (for altitude less than 950 m or 5117 ft) 10°C to 55°C (50°F to 95° F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)

Table 10. Relative humidity specifications

Relative humidity Specifications
Storage 5% to 95% RH with 55°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.

Table 11. M aximum vibration specifications

Maximum vibration Specifications
Operating 0.26 Gig, at 5 Hz to 350 Hz (all three axes).
Storage 1.88 Gig, at 10 Hz to 500 Hz for 15 min (all six sides tested).

Table 12. Maximum shock specifications

Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

Table 13. Maximum altitude specifications

Maximum altitude Specifications
Operating 5048 m (10,000 ft}
Storage 12,000 m (59,570 ft)

Table 14. Operating temperature de-rating specifications

Operating temperature de-rating Specifications
Up to 35°C (95 F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (5,117 ft).
55°C to 40°C (95°F to 104 F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (5,117 ft).
40°C to 45°C (104 F to 115° F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (5,117 ft).
Standard operating temperature

Table 15. Standard operating temperature specifications

Standard operating temperature

Specifications

Continuous operation (for altitude less than 950 m or 5117 ft) 10°C to 55°C (50°F to 95° F) with no direct sunlight on the equipment.
Humidity percentage range 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point.
Expanded operating temperature

Table 16. Expanded operating ternperature specifications

Expanded operating temperature Specifications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to US°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C.
For temperatures between 55°C to 40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
1% of annual operating hours —5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to US°C), the system can operate down to —5°C or up to 45°C for a maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).

NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event Log.

Expanded operating temperature restrictions
  • 128 GB LRDIMM is not supported for FAC.
  • Do not perform a cold startup below 5°C.
  • The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
  • 150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
  • Redundant power supply unit is required.
  • Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
  • PCIe SSD is not supported.
  • NVDIMM-Ns are not supported.
  • DCPMMs are not supported.
  • Mid drive tray is not supported.
  • Rear storage devices or drives are not supported.
  • GPU is not supported.
  • Tape backup unit is not supported.

Thermal restrictions

Following table lists the configuration required for efficient cooling.
Table 17. Thermal restrictions configuration

Configuratio n Number of
processo rs
Heatsink Processor/DI MM blank DIMM

blanks

Type of air shroud Fan
PowerEdge R740xd One 1U standard heat sink for CPU s 125 W  

 

Required

 

Not required

 

 

Standard

Four standard fans and one blank to cover two fan slots
One 2U standard heat sink for CPU > 125 W
PowerEdge R740xd  

 

2

Two 1U standard heat sink for CPU s 125 W  

 

Not required

 

Not required

 

 

Standard

 

Six standard fans

Two 2U standard heat sink for CPU > 125 W
PowerEdge R740xd with mid bay 1 One 1U high performance heat sink Required Required Not required Six hiph performance fans
PowerEdge R740xd with mid bay 2 Two 1U hiph performance heat sink Not required Required Not required Six hiph performance fans
PowerEdge R740xd with GPU 2 Two 1U high performance heat sink Not required Not required GPU air shroud Six high performance fans
PowerEdge R740xd with rear drive only  

 

1

One 1U standard heat sink for CPU s 125 W  

 

Required

 

Not required

 

 

Standard

 

Six high performance fans

One 2U standard heat sink for CPU > 125 W
PowerEdge R740xd with rear drive only  

 

2

Two 1U standard heat sink for CPU s 125 W  

 

Required

 

Not required

 

 

Standard

 

Six high-performance fans

Two 2U standard heat sink for CPU > 125 W

Ambient temperature limitations

The following table lists configurations that require ambient temperature less than 35°C.
NOTE: The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess CPU throttling, which may impact system performance.
Table 18. Configuration based ambient temperature restrictions

System Backplane Processor Thermal Design Power (TDP) Processor heat sink Fan type GPU Ambient restriction
PowerEdge 12 x 5.5 inch N/A 25’C
R740xd SAS/SATA + 4 x

5.5 inch + 2 x 5.5 inch

150 W/8 core, US W/12 core, 200 W, 205 W  

1U high performance

High performance fan
24 x 2.5 inch N/A 25’C
SAS/SATA + 4 x

Table 18. Configuration based ambient temperature restrictions (continued)

System Backplane Processor Thermal Design Power (TDP) Processor heat sink Fan type GPU Ambient restriction
2.5 inch + 4 x 2.5 inch
24 x 2.5 inch SAS/SATA AH 30OC
24 x NVMe All except V100 32 GB 30°C
22 x NVMe V100 32 GB 25°C

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 19. Particulate contamination specifications

Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
NOTE: The ISO Class 8 condition applies to data center environments only. This air filtration requirement does not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
NOTE: Air entering the data center must have MERV11 or MERV15
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.
NOTE: This condition applies to data center and non-data center environments.
Corrosive dust ● Air must be free of corrosive dust.
● Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
NOTE: This condition applies to data center and non-data center environments.

Table 20. Gaseous contamination specifications

Gaseous contamination Specifications
Copper coupon corrosion rate <300 A/month per Class G1 as defined by ANSI/ISA71.04-2013.
Silver coupon corrosion rate <200 A/month as defined by ANSI/ISA71.04-2013.

NOTE: Maximum corrosive contaminant levels measured at < 50% relative humidity.