Panasonic ziaino Air Treatment Unit Instruction Manual

ziaino Air Treatment Unit

CONFIRMATION AND SETUP

OPERATING INSTRUCTIONS

ziainoTM Air Treatment Unit
(Space sterilization and deodorization machine)
ziainoTM
( )
‘+16. Model No.
This product is for indoor use only

CONTENTS
SAFETY PRECAUTIONS SETTING REQUIREMENTS OPERATING REQUIREMENTS EACH PARTS IDENTIFICATION
OPERATION WATER SUPPLY/DRAINAGE METHOD ADDING A SALT TABLET

2~6
7
7~8 8~10
11~13 13~15
15

6~2 …………………………………… 7 ………………………………………… 8~7…………………………………….. 10~8…………………………….
13~11 …………………………………………. 15~13 …………………. /

MAINTENANCE WHEN REPLACING THE ELECTRODE UNIT WHEN IDLE FOR A LONG TIME
OPTIONAL ACCESSORIES

16~24 22~23
24
24

24~16 ………………………………………….

24…………………………………….

TROUBLESHOOTING LIST OF ERROR CODES SPECIFICATIONS

25~27 27
BACK COVER

27~25 ………………………

………………………………….

OPERATION

MAINTENANCE OTHER INFORMATION

Thank you for purchasing this Panasonic product. Please read these operating instructions carefully before operation and maintenance. Also, be sure to read the “SAFETY PRECAUTIONS” section (P.2~6) before use. Failure to comply with instructions could result in injury or property damage. Please retain this booklet for future reference.
. . . (6~2 ) ” ” .
.

SAFETY PRECAUTIONS

Please strictly follow

Disconnect power supply before maintenance and filling water.
. For cleaning and descaling see “maintenance” and regarding filling (water supply) see “WATER SUPPLY/DRAINAGE METHOD”.
.” / ” ( ) “” If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
. This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person responsible for the safety. Children should be supervised to ensure that they do not play with the product.
( ) .
.
The safety precautions should be strictly followed in order to prevent injury or damage to properties.
. The following symbols differentiate the levels of danger or injury that may result if the product is not used correctly as instructed.
.

WARNING

CAUTION

Those things shown in this column indicate that there is possibility of causing death or severe injury.

.

Those things shown in this column indicate that there is possibility of causing minor injury or damage to properties.

.

The following symbols are used to indicate the type of instructions that need to be followed. (The symbols given below are examples.)

( ) .

This symbol indicates an action that must not be performed.
.

This symbol indicates an action that must be performed.
.

WARNING

Do not pull the power cord when carrying or storing the product.

.
(Otherwise, the power cord may be

damaged with the possibility

of fire or electric shock.)

)

.(

Do not insert your fingers,

metallic objects or others into

the air inlet, air outlet or gaps.

.
(Otherwise, you may be hurt by the

inner units with the possibility of

electric shock or injury.)

)

2

(.

Insert the power plug into the power socket completely. .
(If the power plug is not fully inserted, electric shock may occur, or a fire may be caused due to overheating of the power cord.) ) (. Do not use damaged power plug or loose power socket.
.
Do not use acidic detergents or citric acid. .
(Otherwise, toxic gas may be produced, which is harmful to your health.)
(. )

SAFETY PRECAUTIONS

Please strictly follow

CONFIRMATION AND SETUP

WARNING

Do not damage the power cord or power plug.
.
Do not cut, modify, excessive distort, twist, squeeze the power cord, and do not place it near heat sources, place heavy weight on it, etc. . (Otherwise, the power cord may be damaged with the possibility of fire or electric shock.) ) .(
Do not let the product get wet.
.
Do not place cups, etc. on the main unit.
.
(Otherwise, the product may short circuit with the possibility of fire or electric shock.)
) .(
For hospitals, rehabilitation centers or the like, please pay attention to the operating places of this product. Make sure that customers with implanted medical pacemakers keep their pacemaker implantation sites away from the opening and closing part of the front panel, water supply tank, drain tank and tray of this product.
.

.
(Otherwise, the magnets on the product may negatively affect the pacemaker.)
) (.

Do not touch the power plug with wet hands.
.
(Otherwise, electric shock may occur.)
.( )

Clean the power plug regularly.

.
(If dust and humidity is found on the power plug, which may cause damage to insulation, causing fire.)
) .(
Disconnect the power plug and wipe it with dry cloth.
. When the product will
not be used for a long period, disconnect the power plug.
.

In case of any abnormality or malfunction, immediately stop using the product and disconnect the power plug.

.

(Otherwise, electric shock, fire or smoke may occur.)

)

(. Examples of abnormality/malfunction>

</ >

Leakage.

.

Operation stops after the power

cord is touched. .
Abnormal noise or severe vibration occurs during operation.

.

The main unit becomes abnormally

hot or emits a smell of burning.

. There is any other abnormalities or
malfunction.

.

Please stop operating immediately and disconnect the power plug, and contact the dealer to check and repair.

. 3

SAFETY PRECAUTIONS

Please strictly follow

WARNING

Be sure to only use an AC power supply of 220 V and 50 Hz, instead of any power supplies, universal outlets or connecting devices exceeding the rated values.
220 50 .
(Otherwise, the power cord may be overheated, thus resulting in a fire.)
)
(.

Do not disassemble or modify the product.
.
(Otherwise, the product may catch fire or malfunction, thus resulting in fire or electric shock.)
) (.
Contact the dealer for repair. .
Do not disassemble or modify the electrode unit.
.
(Injury may be caused due to the electrode plates after disassembly.) .( )

CAUTION

Do not place the product in the incline and unstable place or at heights.
(Otherwise, the product .
may fall over and injury may occur, the water may spill out and fire, electric shock may occur or wet furniture, etc.)
)

.(
Do not use the product in the place where oil or inflammable gas may be leaked.

.
(Otherwise, a fire or smoke may occur due to ignition in the product.)

( )
Do not place the product in the place where oil fume is emitted, such as in kitchens.
.
(Otherwise, the product may crack and injury may occur.)

4

(. )

Do not use the product in the place where the air outlet faces animals or plants directly.
.
(Otherwise, it may cause discomfort to the animals and dry out the plant.)
) .(
Do not place the product in the place where the temperature or humidity is extremely high, or watery area, such as bathroom.
.
(Otherwise, current may leak with the possibility of fire or electric shock.)
) (.
Do not push over or overturn the product.
.
(Otherwise, the water may spill out and fire,electric shock may occur or wet furniture, etc.) )
.(

SAFETY PRECAUTIONS

Please strictly follow

CONFIRMATION AND SETUP

CAUTION

Do not sit on or lean against this product.
.
(Otherwise, the product may fall over and injury may occur, the water may spill out and fire, electric shock may occur or wet furniture, etc.)
)
.( Families with children should pay more attention.
.
Do not operate this product in places where indoor fumigation type insecticides are being used.
.
(Otherwise, chemical residue may build up inside the product and discharge from the air outlet, which is harmful to your health.)
)
.( Ventilate the room with fresh air
thoroughly after using insecticides before operating the product.
.
Do not place the product near combustible materials such as lighted cigarette, incense, etc.
.
(Otherwise, these may be absorbed into the product with possibility of fire.)
.( )
Do not let the wind blow directly onto walls or handrails or any other metal objects.
.
(Otherwise, dirt, mold or rust may be caused.)
(. )

Do not drink the water in the water supply tank, drain tank or tray, or feed animals or water plants with it.

.
(Otherwise, human health may be harmed and adverse effects may be caused.)
) (.
Do not use a punctured or damaged water supply tank, drain tank or tray.
.
(Otherwise, discoloration or deterioration of the floor may be caused.)
(. )
Do not clean the product with gasoline or other volatile mixture solvents, and avoid contacting with spray insecticides.

.
(Otherwise, the product may crack or short circuit with the possibility of injury, fire or electric shock.)
) .(
Do not add chemicals, air fresheners, essential oils, etc. into the water supply tank or tray.
.
(Otherwise, toxic gas may be produced, which is harmful to your health. Or, the water supply tank or tray may be damaged, thus wetting the floor and resulting in discoloration or deformation.)
. )
(. 5

SAFETY PRECAUTIONS

Please strictly follow

CAUTION

When disconnecting the power plug, hold the power plug instead of the power cord.
.
(Otherwise, the power cord may be damaged with the possibility of fire or electric shock.)
) .(
Keep the room well-ventilated when using the product together with a burner.
.
(Otherwise, carbon monoxide poisoning may occur.)
) .(
This product cannot remove carbon monoxide.
.
When carrying the product. .
Turn off the product and disconnect the power plug, take out the tank, and pour water out of the water supply tank, drain tank and tray. . (Otherwise, discoloration or deterioration of the floor may be caused.)
(. ) Hold the left and right handles, but not the louver, operation part cover, and the front panel to carry the product.
.
(Otherwise, the product may slip out injury may occur.)
.( )

Make sure that no water spills out when carrying the water supply tank, drain tank or tray. If any water spills out, wipe it off immediately.
. .
(If water spills out on the floor, etc., discoloration or deterioration may be caused due to the bleaching effect of hypochlorous acid.)
)
(.
When draining the water, turn on the tap to flush the sink clean.
.
(Otherwise, the sink and water pipe may oxidize to form rust.)
(. )
Clean the water supply tank, the drain tank and the interior of the main unit frequently.
.
Replace the water in the tank with new tap water every day.
. (When the product is not operating, a foul odor may occur due to mildew and miscellaneous bacterium breeding caused by dirt or incrustation, which may be harmful to your health.)
) (.
When you feel uncomfortable, stop using the product immediately and consult a doctor at once.
.
(Otherwise, physical discomfort may be caused.)
(. )

6

SETTING REQUIREMENTS

When used beside a wall, etc.

Place the main unit indoors and use it

. Keep a safe distance during use as instructed below.
. (Poor ventilation may cause the internal temperature of the main unit to rise, thus resulting in malfunction.)
)
(.

within the ambient temperature range of 5 °C to 35 °C.
. 35 5
Do not set the product in the following places.
. Where the product will be exposed directly to sunlight, outlet of air conditioner or heat, etc.

150 cm or above 150

Air outlet

. (Otherwise, deformation, deterioration,
degeneration, discoloration or malfunction

may be caused.)

Air inlet
1 cm or above
1

30 cm or above 30

)
.( Near objects such as TV and radio.
. (Otherwise, visual disturbances or noises may be caused.)

30 cm or above 30

100 cm or above 100

(. ) Keep a distance of 1 m or above.
. 1 Do not use the same power socket with

Do not put any obstacles at the inlet and

TV, radio, etc.

outlet of the product.
. (Otherwise, it may affect product

. (Otherwise, visual disturbances or noises may
be caused when inserting the power plug.)

performance.)

)

(. )

(. In this case, insert the power plug into

another power socket.

OPERATING REQUIREMENTS

.

CONFIRMATION AND SETUP

Do not place any object on the product.
. (Otherwise, the product may malfunction.)
(. )
Do not use the product with the air inlet filter removed.
. (Otherwise, dust may build up inside the main unit, thus resulting in malfunction.)
(. )
When there may be freezing, please empty the water supply tank, drain tank and tray.
.
(Operating with frozen water may cause malfunction.)
(. )
Do not block the air outlet. .
(Otherwise, misoperation or malfunction may be caused.)
(. )

Clean the walls regularly. .
Using the product continuously at the same location may result in dirty surrounding walls due to the air inhaled by the product. You are recommended to clean the walls regularly.

.
Do not disconnect the power plug . unless the product will not be in use for a long time.
. (Otherwise, mildew and miscellaneous bacterium breeding may be caused as sterilization is not available.)
)
(. Make sure that there is water in the water supply tank and keep the power plug inserted since the cleaning operation (Page 13) will start automatically once the product stops working.

(13 )
. 7

OPERATING REQUIREMENTS

If the product will not be in use for a

long time, disconnect the power plug,

and empty the water supply tank,

drain tank and tray.

. (Otherwise, it may cause mildew and

miscellaneous bacterium breeding since

the effect of hypochlorous acid is

weakened while the power is off.)

)

.(

There is no problem if the power plug is

disconnected briefly.

.

Do not use the product in a smoking

environment.

.

(Otherwise, performance degradation may

be caused and the replacement cycle of the

electrode unit, sterilization filter and dust

filter may be shortened.)

)

(.

(If the product inhales cigarette smoke, the

interior of the main unit may become dirty

with cigarette tar, and dirty water containing

cigarette tar or other components may be

blown out from the main unit.)

)

(.

About the salt tablet

The salt tablet is applicable to this product

only.

.

Be sure to use the supplied or optional salt

tablet (Page 24).

.(24 ) Be sure to add one salt tablet into the tray

after water is supplied.

. (If no salt tablet is added, the effect of

hypochlorous acid may be weakened or even

completely eliminated.)

)

.( Tighten the cover to keep the salt container

sealed after unpacking.

. Do not swallow any salt tablets.

. If salt tablets are swallowed by accident, drink

enough water immediately. (It is recommended

to drink 500 mL water per salt tablet.)

(. 500 ) . If too many salt tablets are swallowed, or if

a patient with hypertension or heart disease

swallows salt tablets by accident, consult a

doctor at once.

.

EACH PARTS IDENTIFICATION

Main unit
Operation part cover
Front display part
Front panel
Water-level window

Louver

Air outlet
Opening and closing part

Handle (left and right) ( )

Air inlet (left and right) ( )

Power cord

Power plug

8

EACH PARTS IDENTIFICATION

Accessories
Salt tablet (About 1,000 tablets) ( 1000 )

Handle

Control panel

Drain tank

Front display part

Floater (inside) ()
Water supply tank

Sterilization filter assembly Floater (inside) ()
Drain pump

Tray
Anti-fungus assembly (inside) )
(

Dust filter (left and right)

Electrode unit (inside)

( )

()

Pre-filter (left and right)

( )

Control panel

CONFIRMATION AND SETUP

Digital display

Electrolytic strength button/indicator

Air volume

Salt input

button/indicator confirm button

/

/

Electrode reset Cleaning reset

Safety lock

Brightness Off/On Power Off/On

button/indicator button/indicator button/indicator button

button

/

/

/

/ /

9

EACH PARTS IDENTIFICATION

Front display part

Error indicator

Door open indicator

Water refill

Salt input

indicator

confirm indicator

Drain

indicator

Operation indicator

Status indicator

When the electrode reset indicator blinks or lights on

Blinking: The electrode replacement time is approaching. The electrode reset indicator will

become steady on after blinking for about one month.

. . :

Please replace the electrode unit. (Page 22~23) (23~22 ) .
Steady on: The product does not work.
. : When the cleaning reset indicator lights on <About once a month>

Status indicator
Lighting on from the center to both sides: Normal operation is in progress.
. :

< > Please perform maintenance.
. After the maintenance, install the dust filter,
tray, pump assembly, anti-fungus assembly,

Blinking on both ends at the same time: Preparatory operation is in progress.
. :

and sterilization filter assembly (Pages 16~22) back to the main unit. After installation, press

and hold

for about 3 seconds.

Blinking at the center: Cleaning operation is in progress.

. :

(22~16 )

. . 3
If you perform maintenance before the
cleaning reset indicator lights on, press and

Blinking alternately at two positions: Drying operation of the sterilization filter is in progress.
. :

hold

for about 3 seconds as well.

. 3

When the error indicator lights on

Please check the error code displayed

on the digital display. (Page 27)

(27 ) .

When the door open indicator lights on

The front panel is open or not closed properly,

and the product cannot operate at this time.

. When the water refill indicator lights on

There is little or no water in the tray, and the

10

product cannot operate at this time. .

When the drain indicator lights on
The drain tank is full of water. Please empty the drain tank and install it back; otherwise the product cannot operate. . .
When the salt input confirm indicator lights on
One salt tablet should be added. After adding, press the salt input confirm button on the control panel; otherwise the product cannot operate.
. .
When the operation indicator lights on
The product is operating normally.
.

OPERATION

CONFIRMATION AND SETUP

Preparations: Before setup, fill in the date of first use on the “(Check records)” label : on the inner surface of the front panel.
. “( )”

Replacement of anti-fungus assembly
Approx. once every five years (When operating 12 hours a day)
Part No. JDJPL7000023
Date installed:

Replacement of dust filter
Approx. once every two years (When operating 12 hours a day)
Part No. JDJPL7000012
Date installed:

Replacement of sterilization filter
Approx. once every five years (When operating 12 hours a day)
Part No. JDJPL7000020
Date installed:

Insert the power plug into the power outlet.

Replacement of electrode unit
When the electrode unit replacement indicator blinks (Approx. once every five years)
Part No. JDJPL7000016
Date installed:

. Supply/drain water. (“Water supply/drainage method” on Page 13~15)
(15~13 ” / “) . /

1 Start to operate. .
(The operation indicator lights on)
) (
2 Select the operation mode. .
Press this button to switch level by level.
.
(The indicator lights on) ( )

The product enters preparatory operation in about 20 seconds after the button is pressed. (When the brightness switch is turned on, the status indicator starts blinking on both ends at the same time.) ) . 20 (.
The product does not blow out air during preparatory operation. .
After the preparatory operation is completed, the product starts to operate. .
The air volume can be set in 3 levels.
. 3

Low

Med

High

The factory setting is “High” mode. .””
It can be set during preparatory operation. .

11

OPERATION

3 Stop operating. .
(The indicator lights off) ( )

The product continues to blow air for about 10 seconds after the button is pressed. (The purpose is to drain the hypochlorous acid accumulated in the main unit.)
. 10 .( )

Notice

If the front panel is opened during operation, the product will sound “BIBIBIBIBI!” and pause the operation. While the front panel is open, the door open indicator keeps blinking. The product enters preparatory operation in about 20 seconds after the front panel is closed. After the preparatory operation is completed, the product returns to the operation mode before the front panel is opened. . . “!”
. . 20

Adjusting the wind direction
You can change the wind direction by adjusting the louver by hand. .
The louver is adjustable in 3 levels. . 3

About 90°

About 60°

About 45°

90

60

45

Switching the brightness
If you are not satisfied with the brightness, press this button to turn off the status indicator. Then other indicators will dim.
. .
Locking the operation

Selecting the electrolytic strength

You can select the amount

of the hypochlorous acid to

be produced.

Press this button to switch level by

.

level.

The purpose is to prevent

.

misoperation.

.

(Press the button for about 3 seconds)
) ( 3 (The indicator lights on)
( )

With this setting, if you press

any button other than

,

the product will sound “BI-BI-”

and operation is not possible.

“”

.

If you are not satisfied with the smell in the room, or if you want to improve the sterilization effect, select “H”. (You may smell some chlorine during electrolysis.) (The factory setting is “M”.)
) .””
(.”” ) (.

To cancel this mode
Press the button for about 3 seconds again. (The indicator lights off)
( ) . 3
12

OPERATION

Cleaning operation (Auto) ()

In order to keep its inside clean, the product will automatically perform the cleaning operation regularly (for approximately 4 minutes every 4 hours) when it is idle.

. ( 4 4 )

(A gentle breeze may blow out during the cleaning operation.)
.( )

Requirements
Please check that there is water in the water supply tank as the cleaning operation is not possible without water.

(The status indicator is blinking at the center.)
) (.

.
Do not disconnect the power plug since automatic control is active when the product is idle.
.
During the idle period, the product will no longer drain or clean when the drain tank is full.

.

OPERATION

WATER SUPPLY/DRAINAGE METHOD /

When the water supply tank runs out of water, the product will sound “BIBI” 5 times and stop operating. (The water refill indicator and drain indicator are blinking.)
5 “” (. ) .
Notice
If you remove the water supply tank still with water, the drain indicator will blink after about 5 seconds. After the drain indicator blinks, please empty the drain tank; otherwise the product cannot operate. . 5 .

Water refill

Drain

Water-level window Used to check the remaining amount of water in the water supply tank.

.

CAUTION
Make sure that no water spills out when carrying the water supply tank, drain tank or tray. If any water spills out, wipe it off immediately.
. .
(If water spills out on the floor, etc., discoloration or deterioration may be caused due to the bleaching effect of hypochlorous acid.)
(. )
When draining the water, turn on the tap to flush the sink clean. .
(Otherwise, the sink and water pipe may oxidize to form rust.) (. )
13

WATER SUPPLY/DRAINAGE METHOD /

Make sure to use the tap water.

. (Because chlorination has been performed generally for tap water and hence the miscellaneous bacterium is difficult to breed.)

)

(. Do not use the following water.

. Hot water above 40 , or water mixed with
detergents.

. 40

(Otherwise, the tank deformation may be caused.)

(. )

Water mixed with chemicals, air fresheners

and essential oils.

.

(Otherwise, the tank may be damaged and the furniture, appliances, etc. may be wet. Page 6)

. )

(6
Water from a water purifier, alkaline ion water,
mineral water

(Otherwise, mildew and miscellaneous bacterium may multiply fast.)

(. )

Well water

(Otherwise, mildew and miscellaneous bacterium breeding may be caused, discoloration may occur, and the replacement cycle of the electrode unit may be shortened.)

)

(.

With a full tank of water supports continuous operation of up to 9.6 hours.

9.6

. (When the air volume is set to “H”, the indoor temperature is 20 and the relative humidity is 30%)

20 “” )

(30%

Remove the tank
1Remove the water supply tank and drain tank from main unit.
.
Be sure to disconnect the power plug when adding water. .
Open the front panel. .

Remove the water supply tank and drain tank.
.

Water supply

tank

Drain tank

Take it out carefully to avoid water spilling.

.

Open the tank cover of the water supply
tank. .

Tank cover

14

WATER SUPPLY/DRAINAGE METHOD /

Water supply/drainage and reassembly

Adding a salt tablet

/

2 Add water to the water supply tank, empty the drain tank and install it back to the main unit. .
Add water to the water supply tank and screw the tank cover tightly. . Add water with a kettle, etc. if the tank cannot be put into the sink. .
Water fill line
Hold the tank firmly to avoid tilting. .

3 Add one salt tablet in the tray and press the salt input confirm button. .
Take out one salt tablet from the salt container inside the main unit. .
Salt container
Put one salt tablet into the salt inlet of the tray. .

Empty the drain tank. .

OPERATION

Drain outlet
Meanwhile, turn on the tap to flush the sink clean. .
Install the water supply tank and drain tank back to the main unit. . Install them back to the original position with the tank cover facing down and the mark facing you.
.
Front
Front
Notice
Check that the tray and drain tank are already installed back to the innermost of the main unit. Otherwise, the sensor may not function normally or water may leak out of the product. . .

Tray

Drain tank

Be sure to add one salt tablet in the tray each time when you add water.

. If no salt tablet is added, the effect of
hypochlorous acid may be weakened or even completely eliminated.

.
Be sure to use the supplied or optional salt tablet (Page 24).
.(24 )

Close the front panel.

.

Connect the power plug.

.

(Wipe the water off power plug and your

hands before connecting the power plug.)

(. ) Press the salt input confirm button.
.

(The salt input confirm indicator lights off.)
(. )
Notice
Be sure to close the front panel properly. .
Once the power plug is inserted into the power outlet, the product starts to drain water.
. 15

MAINTENANCE

Precautions before maintenance

Cover

When using chemically treated cloth, be sure to follow the instructions carefully.

Drain tank

.
Do not use the detergents

Water supply tank

shown below.

.

Floater (inside)
()

Polish

Alkaline detergent Acid detergents Thinner Alcohol Kerosene Bleach

Anti-fungus assembly (inside)
()

Electrode unit (inside) ()
Floater (inside) ()
Sterilization filter assembly
Partition panel
Drain pump

Dust filter (left and right)
( )

Tray

Pre-filter (left and right)
( )

WARNING

Make sure to disconnect the power plug before cleaning the product.
.
(Otherwise, the product might operate with the possibility of electric shock or injury.)
) .(

Do not use acid detergents or citric acid.
.
(Otherwise, toxic gas may be produced, which is harmful to your health.)
(. )

Notice
Wipe the main unit clean with a well wrung-out soft cloth when you find it dirty. Wiping with a hard cloth may cause scratch the surface. . .
Do wipe the power plug with a dry cloth. .
As the degree of dirtiness varies with the water quality and operating environment, maintenance may be required even before the cleaning reset indicator lights on or before the specified time is reached, as long as there is an unpleasant odor or the water in the tank is reduced at a slower speed. .

16

MAINTENANCE

User routine cleaning

Electrode unit

Replacement cycle About 5 years

5

Dust filter
About once a month

About 2 years 2

Sterilization filter
About once a month

About 5 years 5

Anti-fungus assembly
About once a month

About 5 years 5

Please contact the dealer for purchase or replacement of the above accessories. .
Cleaning frequency varies with water quality and operating environment. .

Tank <Every day> < >

Flush the water supply tank and drain tank clean.

.
Do not remove the floater.

.
(If the floater is not installed correctly, the product cannot operate and water may leak.)

)

If the floater is shifted:

(.

:

Fit both protrusions into the corresponding

holes of appropriate sizes.

.

Holes
Drain tank

Protrusions
Floater

MAINTENANCE

CAUTION

Make sure that no water spills out when carrying the water supply tank, drain tank or tray. If any water spills out, wipe it off immediately.
.
.
(If water spills out on the floor, etc., discoloration or deterioration may be caused due to the bleaching effect of hypochlorous acid.)
)

(.

When draining the water, turn on the tap to flush the sink clean.
.
(Otherwise, the sink and water pipe may oxidize to form rust.)
(. )
Do not clean the product with gasoline or other volatile mixture solvents, and avoid contacting with spray insecticides.

.
(Otherwise, the product may crack or short circuit with the possibility of injury, fire or electric shock.)
)

.(
17

MAINTENANCE

Pre-filter <About once a month> < >

1Remove the pre-filter and the dust filter. .

Remove the pre-filter and the dust filter

in turn.

.

Pull the top of the Remove the dust

pre-filter forward to

filter.

remove the pre-filter.

.

.

Dust filter <About once a month> < >
Do not operate the product with the dust filter or pre-filter removed. (Otherwise, dust may build up inside the main unit, thus resulting in malfunction.) ) . (.
3 Install the pre-filter and dust filter back. . Install the dust filter and pre-filter back in turn. .
Install the dust filter. .

2 Remove the dirt with a vacuum cleaner, etc. .

Dust filter

Pre-filter

Nozzle

Nozzle

Insert the protrusions (two) of the pre-filter into the holes (two) on the main unit.

() ()

Protrusions

.

Do not wash the dust filter with water.
.
As the degree of dirtiness varies with the operating environment, maintenance may be required even before the specified time is reached, as long as there is an unpleasant odor or the water in the tank is reduced at a slower speed.
.

Holes
Push it in until it clicks into place. .

Reference replacement cycle of the dust filter

Replacement

About once

cycle

every 2 years

Conditions

The product runs 12 hours a day.
. 12

(Optional accessories: Page 24)

(24 : )
18

As the degree of dirtiness varies with the operating environment, replacement may be required even within 2 years if there is still an unpleasant odor or the water in the tank is reduced a slower speed upon maintenance.
.
After replacement, fill in the replacement date, etc. on the “(Check records)” label on the inner surface of the front panel.
“( )” .

MAINTENANCE

Tray·Partition panel <About once a month>

< >

1 3 Remove the tray from the main unit. .

Empty the tray and flush thoroughly. .

Slide up the slider latch to the top.1

Remove the tray.

1.

.

Remove the incrustation and any other dirt

with a soft cloth moistened in water.

.

Slider latch (Sliding

Lift the tray up slightly
and pull it out. .

Wipe the dirt with a swab, or use a toothbrush to scrub it.

while pinching.) (. )

.

4 1You cannot take the tray out without lifting the slider latch (electrode unit). Therefore, be sure to check that the electrode unit is

Install the partition panel, sterilization filter assembly and anti-fungus assembly onto the tray.

lifted before taking the tray out. .( )
.
2Remove the partition panel, sterilization filter assembly and anti-fungus assembly from the tray, and clean them one by one.

.
Place the anti-fungus assembly horizontally into the recess. . Gear
Insert the partition

.
Partition panel (pump assembly) ( )
Sterilization filter assembly

panel along the groove.
.
Install the gear of the sterilization filter assembly into

Recess

the recess of the tray.

Anti-fungus assembly

.

Floater

5Install the tray back to the main unit. .

Do not remove the floater (expanded

Set slider latch at the top position.

polystyrene). (The product may not work if they are not installed correctly.)

. Install the tray.

) .( ) (.
If the floater is shifted: Put the protrusions under the buckle.
. : While pressing them in the arrow direction,

. Slide down the slider latch to the bottom.2
2. Slider latch (Sliding while pinching.)
(. )

insert them into the holes.

.

Floater

Buckle (Tray) ()
Hole (Tray)

Hole (Tray)
()

2 You cannot close the front panel without

()

Protrusions

pulling the slider latch to the bottom.
. 19

MAINTENANCE

MAINTENANCE

Pump assembly <About once every 6 months>

< 6 >

1Remove the pump assembly from the partition panel. . Unscrew the hand screw and remove the coupler from the partition plate. .
Coupler

4 Install the pump filter and impeller onto the pump assembly. .
Install the pump filter, impeller and cover. .
(Align the pump filter and the cover with the respective positioning marks, and fasten the buckles (three).) )
(.()

Pump

Hand screw

assembly

Positioning mark

Positioning mark

Lift the drain pump up to pull it out.
.

Drain pump

2 Remove the pump filter and impeller from the pump assembly.

Rotate the cover on the opposite.side to the
pump filter in the arrow direction () and remove the impeller.

(æ)

Impeller Cover

. Pump filter

Buckles (three) ()

Buckles (three) ()

5 Install the pump assembly onto the partition plate. .

Align the buckles (two) of

Install the hand

the coupler with the notches screw onto the

and insert them in.

partition plate.

()

Buckles (two) ()

.

.

Partition plate

20

Inside the cover Sealing ring
(Do not remove it.)
.( )
3 Wash it with water. .
Do not remove the hose or the sealing ring. .
Wipe the dirt off the pump filter with a cotton swab, or use a toothbrush to scrub it. .
Install the removed parts back properly; otherwise:
: The tank cannot supply water to the main
unit anymore. .
Water may leak out or the product may malfunction. .
Make sure that the sealing ring is installed correctly.
.

Notches

Coupler

Hand screw

Align the buckle with

the hole and insert it

vertically downward.

.

Hole

Buckle

Suggested time–Cleaning frequency varies with water quality and operating environment. It is suggested to clean it at least about once every 6 months.

. 6 .

MAINTENANCE

Anti-fungus assembly <About once a month> < >

Wash it with water. .
Do not scrub it with a brush, nor disassemble it. .
Check whether the mesh of the anti-fungus assembly is damaged.
. *GEBNBHFE
SFQMBDFJU
. $IFDLXIFUIFSUIFIPVTJOHPG
UIFBOUJGVOHVTBTTFNCMZJTEJSUZ .
*GEJSUZ
XJQFJUDMFBOXJUI BTPGUDMPUI .

Notice
The anti-fungus assembly

Housing

may have powder sometimes.

This is normal and not a

problem with use.

.

.

The anti-fungus agent will be

small along with the use. This

is not a problem with the

anti-fungus performance.

. .
The anti-fungus agent has its own special

smell, harmless to humans.

.

Anti-fungus agent

Reference replacement cycle of the anti-fungus assembly

Replacement cycle
Conditions

About once every 5 years
5
The product runs 12 hours a day.
. 12

(Optional accessories: Page 24)
(24 : ) After replacement, fill in the replacement date, etc.
on the “(Check records)” label on the inner surface of the front panel.
)” . “(

MAINTENANCE

4UFSJMJ[BUJPOGJMUFSBTTFNCMZ”CPVUPODFBNPOUI < >

1 Disassemble Remove the filter plate and sterilization filter from the filter frame.

.

Filter frame Sterilization filter Filter plate

0QFO

%POPUSFWFSTFJU

2 Wash

Press and wash sterilization filter with clean/warm water. . /
%POPUTDSVCJUXJUIBCSVTIPSXBTIJUXJUIBXBTIJOHNBDIJOF
.

%POPUESZJUXJUIBESJFS %PJOHUIJTNBZDBVTFTISJOLBHF

( ) . 8BTIUIFGJMUFSGSBNFBOEGJMUFSQMBUFXJUIXBUFS

3 Install *OTFSUUIFTUFSJMJ[BUJPOGJMUFSJOUPUIFGJMUFSGSBNF *OTUBMMUIFGJMUFSQMBUFPOUPUIFGJMUFSGSBNF

.

.

%POPUMFBWFBHBQCFUXFFOUIFTUFSJMJ[BUJPOGJMUFSBOEUIFGJMUFSQMBUFBTXFMMBT

UIFGJMUFSGSBNF
OPSQSFTTUIFSPVOEQBSUTPGCPUIFOET

0UIFSXJTF
QFSGPSNBODFEFHSBEBUJPONBZCFDBVTFE

.

(. )

21

MAINTENANCE

Reference replacement cycle of the sterilization filter

Replacement cycle

About once every 5 years ¸ 5

(Optional accessories: Page 24) (24 : )

Conditions

5IFQSPEVDUSVOTIPVSTBEBZ . 12

As the degree of dirtiness varies with the water quality and operating environment, replacement may be required even within 5 years if there is still an unpleasant odor or the water in the tank is reduced at a slower speed upon maintenance. 5 .
Please dispose of the used sterilization filter as non-combustible garbage. However, do not discard the filter frame and filter plate. . .
After replacement, fill in the replacement date, etc. on the “(Check records)” label on the inner surface of the front panel. . “( )”
When replacing the electrode unit
When the electrode reset indicator blinks

When the electrode reset indicator blinks, replace the electrode unit. .
The electrode reset indicator will become steady on after blinking for about one month. (When the electrode reset indicator becomes steady on, the product cannot operate.) ) . (.
About once every 5 years. (In the case that the product runs 12 hours a day.)
(. 12 ) . 5 The replacement cycle may vary with the water quality and operating environment.
. After replacement, fill in the replacement date, etc. on the “(Check records)” label on
the inner surface of the front panel. . “( )”

Requirements
Be sure to use the electrode unit dedicated for this product. (See “Optional accessories” on Page 24.) (.24 ” ” ) .
When lifting up or pressing down the electrode unit, please pinch the slider latch to move it. .

22

MAINTENANCE

Removing/Installing the electrode unit /

Removing
Disconnect the power plug. .
Open the front panel. .
Take the water supply tank and drain tank out. .
Lift the slider latch up and place the electrode unit into the main unit.
. Remove the tray from the main unit.
. Press the slider latch down and take the
electrode unit out from the main unit.
.
Electrode unit

Installing
Install the connector of the new electrode unit onto the main unit. .
Insert the protrusions (two) into the recesses (two). .() ()

Recesses Protrusions

Align with the direction of the line

Install the housing onto the electrode unit.

. Align the buckles with the holes.

Holes (two)

.

()

Buckles (two)
()

Close

MAINTENANCE

Remove the housing of the electrode unit. .

Cover

Open
Press

Remove the connector. .
Press
Press
Connector

Insert the housing completely to the end.
.
(If not installed securely, the housing may fall off when you lift the slider latch.)
(. )
Lift the slider latch up and place the electrode unit into the main unit.
. Install the tray back to the main unit.
. Pull the slider latch down.
. Install the water supply tank and drain tank
back to the main unit. .
Insert the power plug into the power outlet,

and press and hold

for about 3 seconds.

Close the front panel.

. 3

.

Disposing of the electrode unit
The electrode unit is a mixture of plastic and metal. Please dispose of it according to your local
garbage classification rules.
. . 23

MAINTENANCE

When idle for a long time
Disconnect the power plug. .
Empty the water supply tank, drain tank and tray, and clean the product. .
Wipe each part dry and install them back to the main unit. The water refill indicator, drain indicator and salt input confirm indicator will blink. . .
Insert the power plug into the power outlet to enter drying operation of the sterilization filter. (To prevent mildew and miscellaneous bacterium breading) . ( )
Drying operation of the sterilization filter .

Press and hold both

and

for about 2 seconds.

.
The product will start the drying operation of the sterilization filter in the [H] mode.

(The status indicator blinks alternately at two positions.)
(. )

.[]

It will stop automatically after about 2 hours.

.

To cancel it halfway, press and hold these two buttons for about 2 seconds again.

Notice

.

If the drying operation is canceled halfway, the sterilization filter may not be completely dried.

.

After the operation is stopped, disconnect the power plug and cover the main unit with a plastic bag or the like. .
Store the product in a dry, level and stable place in an upright position.
.

OPTIONAL ACCESSORIES

Replacement salt tablets

Replacement electrode unit

Replacement dust filter (2 pieces)
()

Replacement sterilization filter

Replacement anti-fungus assembly

Part No.: : F-ZPL10Z

Part No.:
: JDJPL7000016

Part No.: :
JDJPL7000012

Not include filter plate and filter frame.
.
Part No.: : JDJPL7000020

Please contact the dealer for purchase or replacement of the above accessories. .
24

Part No.: :
JDJPL7000023

TROUBLESHOOTING

If a problem is encountered, please investigate it by going through the following items. If the problem still persists, please disconnect the power plug and contact the dealer for repair.
. .

Possible situation
The air volume is small.
.

Please confirm the following
Is the pre-filter or the dust filter clogged with dust or the like?
Clean the filter. (Page 18)
(18 ) . Is there incrustation or dust accumulated on the sterilization
filter assembly?
Remove the incrustation and dust. (Page 21) (21 ) .

Have 20 seconds elapsed after

is pressed?

MAINTENANCE

20

The product enters preparatory operation in about 20 seconds

after

is pressed. (Page 12)

(12 ) . 20

No air is blown out.
.
Chlorine is smelt.
.

If no air is blown out even after 20 seconds have elapsed, contact the dealer.
. 20 Is the salt input confirm indicator blinking?
Make sure that you have added one tablet of salt into the tray
and then pressed the salt input confirm button. (Page 15) (15 ) . Is the door open indicator blinking?
Make sure that the front panel is closed. (Pages 12 and 15)
(15 12 ) .
That is because hypochlorous acid decomposes dirt and odor.
. If you do not like the smell of chlorine, adjust the electrolysis
strength to “L”. (Page 12) (12 ) .”L”

The air coming out from
the air outlet smells bad.
.

Are the tray and sterilization filter dirty, or are you not using new tap water?
Clean the tray, sterilization filter and water supply tank
(Pages 17, 19 and 21) and refill with new tap water. (Page 15)
(21 19 17 ) (15 ) .

Water in the water supply
tank dose not decrease.
.

Is the pre-filter or the dust filter (air inlet) clogged with dust or the like? ( ) Clean the filter. (Page 18)
(18 ) . Is there incrustation or dust accumulated on the sterilization
filter assembly?

Remove the incrustation and dust. (Page 21)

(21 ) .
25

TROUBLESHOOTING

Possible situation
Water in the water supply
tank dose not decrease. .

There is still water remaining
in the drain tank even after you have emptied the drain tank and installed it back.

.
A “click” sound is heard at
the beginning of operation. . “”
A “puchee” sound is heard.
.””

A rumbling sound is heard.
.

The indicator does not
light on even after is pressed.

.

Please confirm the following
Is the humidity high or the room temperature low?
When the humidity is high or it’s cold, the water in the water supply tank decreases slowly. .
Is the front panel closed?
Be sure to close the front panel properly. (Pages 12 and 15) (15 12 ) .
To keep the water in the tray clean, the drain pump will pump out the remaining water in the tray. . It is not abnormal. Please continue to use the product. . .

This is the sound of pumping water made by the drain pump in the main unit.
. It is not abnormal. Please continue to use the product.

. .

This is the sound of supplying water from the water supply tank.
. It is not abnormal. Please continue to use the product.
. .

This is the sound of pumping water made by the drain tank. You need to wait for a while when the room temperature is low in winter or when the water temperature is low.
. .
It is not abnormal. Please continue to use the product.
. .

Is the power plug disconnected?

Make sure the power plug is inserted into the power outlet

and press

.

.

11 Water has already flowed
into the water supply tank, but the water refill indicator and drain indicator are still blinking.
.
12 Water has already flowed
into the drain tank, but the drain indicator is still blinking.
.

Are the water supply tank and drain tank installed properly?
Install the water supply tank and drain tank correctly. (Page 15) (15 ) .
Is the drain tank emptied?
Empty the drain tank. (Page 15) (15 ) .
The drain indicator keeps blinking until sufficient water has been supplied to the tray. . Add water to the water supply tank and install it onto the main unit. (Page 15) (15 ) .

26

TROUBLESHOOTING

Possible situation
13 The main unit is tilted or
falls over. .

Please confirm the following

Disconnect the power plug.

Right the main unit. (Wipe any water off it.)

.

.( ) . Leave the product idle for more than half a day.
(If water enters the inside, let it dry completely.)

.( ) .

After water supply/drainage has finished (Pages the power plug back to resume the operation.

13~15),

insert

(15~13 ) /

.

List of error codes

The digital display shows error codes. Check the error code, disconnect the power plug and do the following.
. .

Error code

Cause

U11

Foreign matter is adhered to the electrode unit.
.

U12

The slider latch (electrode unit) is at the top position. . ( )

Action Clear any foreign objects around the electrode unit.
. Reinsert the power plug.

.

Lower the electrode unit. (Page 19)

Reinsert the power plug.

(19 ) .

.

The main unit is tilted or falls over.
.

Refer to “TROUBLESHOOTING” (Page 27). .(27 ) ” ”

U13

The drain tank is dirty. .
The tray is not set securely. .

Clean the drain tank. (Page 17)

Reinsert the power plug.

(17 ) .

.

Place the tray securely and be sure to close the front panel properly. (Pages 15 and 19)

(19 15 ) . Reinsert the power plug.

.

U14

The water in the tray is not clean.
.

Empty the tray and keeps the water clean. (Page 19) (19 ) .
Reinsert the power plug. .

If the problem still persists after you have finished the above operations, please contact the dealer. .

Error code

Cause

Action

F01

The main unit is faulty.

Please contact the dealer for repair.

.

.

27

OTHER INFORMATION

SPECIFICATIONS

Model No. Power supply

Air volume mode

Power consumption (W)1 1()

Noise (dB)2 2()

Air volume (m3/min)

( /3)

Continuous operation time with full water (h)3

3()

Tank capacity (L) ()
Power cord length (m) ()
Product dimension (mm) ()
Product weight () ()

High 72
49
7.0

‘+16.
220 V 50 Hz Med 31
37
4.0

Low
20
20
2.0

9.6

14.0

22.6

About 7.8 (Net capacity: About 7.0) (7.0 : ) 7.8
2
730 (H) x 510 (W) x 307 (L) () 307 × () 510 × () 730
About 17 17

1 The power consumption is about 1 W when the power plug is inserted into the power outlet and the operation is “Off”. (17 W for cleaning operation)
( 17) .”” 1
2 The noise is A-weighted sound pressure level, measured in a total silencing laboratory environment. .
3The continuous operation time with full water is obtained in an environment where the room temperature is 20 and the relative humidity is 30%. The continuous operation time may differ depending on the room temperature and humidity. .30% 20 .

Panasonic Corporation
Web site: http://www.panasonic.com
© Panasonic Corporation 2021

Issue date: 09/2021 09/2021 :
1+16.