Honeywell UV100E Ultraviolet Systems Installation Guide

Home
UV100E Ultraviolet Systems

UV100E1043 AND UV100E2009 AIR TREATMENT SYSTEMS
UV100E3007 SURFACE TREATMENT SYSTEM

PRODUCT DATA

APPLICATION

When installed in forced-air heating and cooling systems, the UV100E Ultraviolet Systems kill airborne or surface micro-organism contaminants like mold and bacteria.
The UV systems use patented SmartLamp™ control technology that monitors the HVAC system to operate the lamps only when needed. This technology extends bulb life up to five times and reduces power consumption, lowering operating costs. The UV systems also include local diagnostics with the SmartLamp™ LED and reset capability.

FEATURES

  • SnapLamp™ features a replacement lamp handle with a detachable replacement bulb, UC18W or UC36W, to make the replacement more economical.
  •  SmartLamp™ Control Algorithm determines optimal UV lamp usage.
  • SmartLamp™ LED shows bulb life and replacement.
  • Reduced power consumption and extended bulb life.
  •  Communicates with other home appliances through Enviracom™ three-wire communications bus.
  •  Automatic brownout and high-temperature protection for UV lamps.
  • Return air models supplied with integrated airflow sensor to monitor air flowing through ductwork.
  •  Dual-purpose reset button:
    — Commands lamp on with a single one-second push.
    — Resets internal lamp run-time timer after bulb replacement with extended five-second hold.
  •  UV-C light kills airborne bacteria and surface mold.
  • UV lamp does not produce ozone.
  •  Easy lamp maintenance with quick, easy bulb replacement.
  • Sealed unit prevents accidental installer/homeowner contact with high voltage and ultraviolet rays.
  •  The safe design prevents the lamp from lighting unless the base is correctly mounted on the HVAC duct.
  • Lamplight indicator to safely view lamp operation.
  •  The power cord that plugs into the 120 Vac electrical outlet.
  •  Five-year limited warranty.

UV100E ULTRAVIOLET SYSTEMS

SPECIFICATIONS

IMPORTANT

This product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed. The specifications in this publication do not include normal manufacturing tolerances; therefore, an individual unit may not exactly match the listed specifications. The UV100E Ultraviolet System is available in three models: a single-lamp air treatment system, a dual-lamp air treatment system, and a surface treatment system.
UV100E Air Treatment Systems (single-lamp and dual-lamp) are mounted in the return air duct of an
HVAC system. The single-lamp unit has moderate efficiency and the dual-lamp unit has high-efficiency performance against airborne bacteria in return for air applications.
— Without Enviracom hooked up: monitors air flowing through ductwork using supplied airflow sensor mounted to the backside of the unit. Operates lamp when air is flowing (120 fpm minimum), leaving the lamp on for 40  minutes after airflow stops. If airflow resumes during the 40 minutes, the timer resets to 40 minutes. When no airflow is detected for 40 minutes, the lamp turns off until the next occurrence of airflow.
— With Enviracom hooked up: monitors thermostat load information instead of using airflow sensor to operate on and off.
UV100E Surface Treatment System is mounted in the supply-side air duct or downstream or upstream from air conditioner evaporator coils in the HVAC system. It reduces mold growth and spores on duct surfaces, coils, and drip pans.
— Does not use an airflow sensor.
— Without Enviracom hooked up: operates steadily on/off cycle: lamp operates three hours on, three hours off for a total two-year life cycle.
— With Enviracom hooked up: after initial three hours run time, operates three hours on and three hours off during times when the evaporator A-coil may be exposed to moisture, including when the control sees a  cooling call and for 30 days after the last cooling occurred. This operation extends the bulb life beyond two years.

Efficiencies:

  • UV100E Surface Treatment System: Kills up to 99.9% of mold on system cooling coils.
    — Test performed in a test duct showed a reduction in colony-forming aspergillus niger mold spores when the surface was irradiated at a distance of 18 in. for three hours in still air, using new lamps.
  • UV100E Air Treatment System (dual-lamp): Kills up to 87% of airborne bacteria passing by the system.
    — Test showed a single-pass kill rate of Serratia marcescens bacteria in a clean metal 12 in. x  25 in.  duct at an airflow rate of 2000 cfm using new lamps.
  • UV100E Air Treatment System (single-lamp): Kills up to 70% of airborne bacteria passing by the system.
    —  Test showed a single-pass kill-rate of Serratia marcescens bacteria in a clean metal  12 in. x 25 in. duct at an airflow rate of 2000  cfm using newlamps.

Enviracom™ Communications Capabilities:

  • Communicate with the homeowner through a three-wire communication bus using 24 Vac thermostat connections.
    — Hooked up to single-lamp and dual-lamp Air Treatment System: uses thermostat load information instead of airflow sensor.
    — Hooked up to Surface Treatment System: uses thermostat load information to operate during times evaporator A-coil may be exposed to moisture to extend bulb life beyond two years.
  • Sends messages to communicate reset and receives remote reset, when available.
    — Lamp change indication cannot be reset by cycling power.
    — When Enviracom is transmitting messages, shows a flashing green Enviracom LED on the bottom of the unit. Electrical Ratings:

Voltage Rating: 120 Vac, 60 Hz. 
Current and Power Ratings:

Model

Input Power (A)

Bulb Wattage (W)

UV100E1043 Air Treatment System (single lamp) 0.46 18
UV100E2009 Air Treatment System (dual lamp) 0.8 36 (each bulb)
UV100E3007 Surface Treatment System 0.85 36

Temperature Ratings:
Ambient Temperature Range: 30°F to 104°F (-2°C to40°C).
Bulb Temperature Range (In Moving Air): 30°F to 140°F (-2°C to 60°C).
Relative Humidity:
Up to 95% RH, non-condensing.
Dimensions:
See Fig. 3.
Approvals:
Underwriters Laboratories: File no. E223009
The health aspects associated with the use of this product and its ability to aid in the disinfection of environmental air have not been investigated by UL.

INSTALLATION

Resistance to UV radiation Polymeric cabinet, structural, and current-carrying parts and wiring which are subjected to UV-C irradiance from a UV lamp system shall be shielded from or out of the line-of-sight of the UVC light, or be constructed of a material that is capable of withstanding UVC exposure levels expected in the product without degrading.

When Installing this Product…

  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check the rating given in the instructions and on the product to make sure the product is suitable for your application.
  3. Installer must be a trained, experienced service technician.
  4. After installation is complete, check out product operation as provided in these instructions.


WARNING

UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision. View illumination only through lamp light indicator on lamp handle.
To prevent exposure to ultraviolet light, disconnect power to ultraviolet system before servicing any part of the heating and air conditioning system.
Do not mount a device in a location that allows ultraviolet light to be seen after installation.
Do not attempt to bypass the duct mount switch.

CAUTION
Personal Injury Hazard.
Power supply can cause electrical shock.
Disconnect power supply before beginning installation. Do not an open base unit or lamp handle; there are no user-serviceable components inside.
Selecting Mounting Location


CAUTION
Equipment Damage Hazard.
Ultraviolet light can cause a color shift or structural degradation of plastic HVAC materials.
The select mounting location that prevents exposure to plastic components with unknown resistance to ultraviolet light. Three-feet minimum is recommended between the ultraviolet lamps and plastic-fabricated devices (such as humidifiers and non-fiberglass media filters).
Depending on installation location, the UV System can operate as an Air Treatment System or as a Surface Treatment System.
Not for wet location – cannot be subject to blow-off moisture from evaporation coil.
Air Treatment System
Installed in the return air duct, the Air Treatment System kills a high percentage of airborne germs circulating through the forced air heating and cooling system.
Individual results depend on careful installation and maintenance and on the actual amount of time the system fan operates. See Fig. 1.

M22857

Fig. 1. Typical Air Treatment System installations.

Surface Treatment System

When installed next to the cooling coil, the Surface Treatment System prevents a high percentage of the growth of micro-organisms such as mold that may grow on duct surfaces, coils, and drain pans. Individual results depend on careful installation and maintenance. See. Fig. 2.

Fig. 2. Typical Surface Treatment installations.

IMPORTANT

If mounting options are limited, protect plastic or rubber materials listed in CAUTION with ultraviolet- let-resistant material such as aluminum foil duct tape.
NOTE: When the installer is uncertain about whether the drip pan in the installation can tolerate UV expo-sure, consult the UV exposure white paper. This is found by doing a search under the “technical lit-erasure” category for form no. 50-8788, at the customer.resideo.com website.

  1. Choose a location that is readily accessible for regular inspection and cleaning. Fig. 1 and 2 and show possible mounting locations.
  2. Allow clearance in front of the device for removing the lamp assemblies. Fig. 3 shows lamp assembly lengths.
  3. Be sure depth can accommodate the full length of the UV lamp for your model as shown in Fig. 3.
  4. Be sure duct mounting location is 8 in. wide mini-mum.
  5. Be sure 120 Vac electrical outlet is within range of unit to plug in the power cord.
  6. Select single-lamp and dual-lamp air treatment system location on HVAC to return air duct that is easily accessible with a flat mounting surface. Select sur- face treatment system location on HVAC supply air duct that is easily accessible with a flat mounting surface; locate the unit so the lamp can surround the evaporator coil and drip pan with ultraviolet light.
  7. Mount to allow correct operation:
    a. Do not mount upside down.
    b. Do not mount with lamps facing up

CAUTION
Sharp Edges Hazard.
Can cause personal injury.
Be careful when inserting the ultraviolet devices into sheet metal cutouts.
Wear protective gloves when working near sheet metal.

Duct Mounting
Use the following instructions to mount the UV System on the air duct of an HVAC system:

  1. Disconnect power to the HVAC system before install- ing the UV System.
  2. Select the appropriate template for your model (seeFig. 18-20).
  3. Place the appropriate template for your model on the duct surface, centering the bulb hole(s) on the duct.
  4. Mark the location on the duct for 2 in. diameter bulb hole(s), unit mounting-screw pilot holes, and when installing a return air model, the 1-1/2 in. airflow sensor hole
  5. Cut 2 in. bulb hole(s) and 1-1/2 in. airflow sensor hole in the duct. Remove any burrs. Note that the air-flow sensor protrudes out of the backside of the device. Be careful to avoid scratching or damaging the airflow sensor.
  6. Use a 3/32 in. drill for pilot holes for mounting screws.
  7. Be sure the duct surface is flat after all holes are drilled.
  8. Position the entire base unit on the duct. Be sure bulb and airflow sensor holes in the duct align with unit holes. Be careful to avoid scratching or damaging the airflow sensor.
  9. Install the unit into duct using three (or two, depending on model) no.10, 2 in. Phillips head sheet metal mounting screws provided. (A spare screw is pro- vided for a three-screw model.)
  10. Tighten screws to 12 to 14 in.-lb so space between case and duct is sealed.

Fig. 3. Ultraviolet System dimensions in. (mm).

CAUTION
Breakable Glass Hazard.
Can cause personal injury.
Be careful when inserting bulb(s) into the lamp base.
Wear protective gloves when handling bulb(s).

MERCURY NOTICE
This device contains mercury in the sealed ultraviolet bulb(s). Do not place your used bulb(s) in the trash. Dispose of properly.
Broken Bulb Cleanup.
Do not use a household vacuum. Sweep debris into a plastic bag and dispose of it properly.
Contact your local waste management authority for instructions regarding recycling and the proper disposal of the old bulb(s).

11. Insert the lamp handle into the base unit with the lamp light indicator at the eleven o’clock position (left of the raised button on the unit cover). See Fig. 4. If you touch the lamp glass with your hands, use a cloth to wipe fingerprints from the glass. See Fig. 5.

Fig. 4. Insert lamp handle into the base unit.

Fig. 5. Use a cloth to wipe fingerprints from the glass.

12. Continue lightly pushing in on the lamp handle while rotating it slowly counterclockwise. This should cause the lamp to handle to drop into the bottom of the lamp well.
13. Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 6.

Fig. 6. Snap lamp handle into place.


WARNING
UV Light Hazard.
Harmful to bare skin and eyes.
Can cause temporary or permanent loss of vision.
View illumination only through the lamplight indicator located on the lamp handle.
To prevent exposure to ultraviolet light, disconnect power to the ultraviolet system before servicing any part of the heating and air conditioning system.
NOTE: If you desire to communicate with other appliances using your Enviracom communication bus, go on to step 14; if not, go directly to step 15.
14. Hook up corresponding appliance wires to the Enviracom communication bus located on the bottom of the UV device base. Be sure to loop wire of other Enviracom appliances or Enviracom common node around the UV base Enviracom screw terminals 1, 2, and 3. See Fig. 7.

Fig. 7. Looping Enviracom appliance or common node wire around UV Enviracom base screw terminals.
15. Plug the cord into the nearby 120 Vac electrical outlet.
16. For air treatment systems, wait ten minutes for the airflow sensor to calibrate. During this time, the furnace fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor to calibrate before powering the furnace causes the airflow sensor to incorrectly calibrate and the device to incorrectly function. If this occurs, remove power to the furnace or turn off the system and fan, wait ten minutes, and then resume normal furnace operation.
17. Reconnect the power to the HVAC system.
18. Choose a location on the adjacent HVAC equipment for the HVAC maintenance UV warning label included in the UV system packing box. Choose a location that a future installer can easily see during any future HVAC maintenance or repair.
19. Adhere the HVAC maintenance UV warning label to the HVAC equipment (selected in step 17) such as the furnace, air cleaner, or humidifier. See Fig. 8.

WARNING/AVERTISSEMENT
UV Light Hazard.
Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at the lamps while illuminated. This heating/air conditioning system is equipped with an ultraviolet air treatment system. To prevent exposure to ultraviolet light, disconnect power to the ultraviolet air treatment system before servicing any part of the heating/air conditioning system.

Risque d’exposition aux UV.
Nocifs pour la peau nue et les yeux. Peut causer une perte de la vue temporaire ou permanente. Ce systeme de chauffage-refroidissement est muni d’un systeme de traitement d’air a (‘ultraviolet. Afin d’eviter tout contact avec les rayons ultraviolets, veuillez debrancher le systeme de traitement d’air a (‘ultraviolet avant de proceder a la reparation ou a la maintenance de toute piece du systeme de chauffage-refroidissement.

32004813-001 REV. B

Fig. 8. HVAC maintenance UV safety label.

CHECKOUT
The installer should verify that the ultraviolet bulb(s) are operating only by viewing the lamp light indicator on the lamp handle. Do not attempt to look directly into the duct to see the illuminated ultraviolet bulbs. See Fig. 9.9. Lamplight indicator, LED, and reset button.

The installer should orient the homeowner to the unit by showing them the blue glow of the lamp light indicator and discussing how to determine when the unit is functioning properly without looking directly into the duct to see the illuminated ultraviolet lamp. The installer should also emphasize the hot surface and electrical shock safety warnings.
The installer should show the homeowner the LED on the front of the UV system and explain operation as follows:

LED Status

Indicates

Homeowner Action

Off 100 to 11% bulb life remaining Nothing
Flashing 10 to 1% bulb life remaining Purchases bulb(s)
Solid 0% bulb life remaining Replaces bulb(s)

a
Bulb life means emitting an adequate amount of UV-C energy to maintain an effective kill rate. At 0% bulb life remaining, the lamp continues to operate until catastrophic bulb failure (bulb burns out) but the kill rate becomes rapidly negligible.

Installer should also orient the homeowner to the reset button on the bottom of the UV system that, when pressed briefly for one second, can be used to command the lamp on for the minimum run time of 40 minutes (air treatment system) or three hours (surface treatment system), depending on system type. And that when a new bulb is installed, the homeowner must hold the reset button for five seconds to reset the internal timers. Cycling power does not reset internal timers.

When using the Enviracom communication bus to communicate with other appliances, the installer should orient the home-owner to the Enviracom LED and three screw terminals. The Enviracom LED flashes when transmitting and lights solidly when there is a fault.

The installer should also explain the extended-bulb life for the surface treatment system. For the single-lamp and dual-lamp air treatment systems, the installer should orient the home-owner to the alternate method of using the UV system to monitor the thermostat load information to turn the lamp off and on instead of using the airflow sensor to control lamp operation and that it communicates the percent remaining bulb life.

The installer should leave the Owner’s Guide with the homeowner and review the bulb cleaning and replacement procedures. A Bulb Cleaning Reminder Schedule is included in the Owner’s Guide to help the the homeowner set up and track a regular cleaning schedule.

TROUBLESHOOTING AND SERVICE

The Ultraviolet System has no field-serviceable parts. Bulb cleaning is recommended as routine maintenance quarterly or every three months. Bulb replacement is required when the LED on the front of the UV system is lighted solidly. See the Owner’s Guide for detailed procedural information.

If systems with an airflow sensor (UV100E1043 and UV100E2009 Air Treatment Systems), incorrectly identify airflow, the airflow sensor may be calibrated incorrectly. To recalibrate the sensor, remove power to the furnace or turn off the system and fan, wait ten minutes, and then resume normal furnace operation. Even if the lamp fails to turn off, the sensor was recalibrated during this operation.

If the internal temperature exceeds the ballast high-temperature limit, the control continues to retry every three hours until the temperature is low enough to run correctly. An Enviracom fault message (when connected) is sent after 72 hours. If reset is pushed during this fault, the control tries to restart but cannot start until the temperature returns to normal.

If the bulb(s) burns out, experiences low supply voltage (brownout), or has an internal catastrophic failure, the control continues to retry once every hour until the problem is corrected. An Enviracom fault message (when connected) is sent after 24 hours. If reset is pushed during this fault, the control tries to restart but cannot start until the fault is corrected.

To determine if a bulb is burned out or another problem exists, press the reset button briefly (one second). The bulb(s) should come on (as indicated by the illuminating lamp light indicator). Hold the reset button longer only when replacing the bulb.

MAINTENANCE

How You Can Maintain Your UV System

You should regularly clean your ultraviolet lamp to maintain the peak effectiveness of your air treatment or surface treatment system. Replace the ultraviolet bulb when the LED status light on the front of your UV System is on steadily.

CAUTION
Personal Injury Hazard.
Power supply can cause electrical shock.
Disconnect power supply before cleaning or replacing ultraviolet bulb(s).
Do not open the base unit or lamp handle; there are no user-serviceable components inside.

CAUTION
Breakable Glass Hazard.
Can cause personal injury.
Be careful when inserting bulb(s) into the lamp base.
Wear protective gloves when handling bulb(s).

Quarterly Bulb Cleaning

MERCURY NOTICE
This device contains mercury (less than 5 mg) in the sealed ultraviolet bulb(s). Do not place your used bulb(s) in the trash. Dispose of properly.
Broken Bulb Cleanup.
Do not use a household vacuum.
Sweep debris into a plastic bag and dispose of it properly.
Contact your local waste management authority for instructions regarding recycling and the proper disposal of the old bulb(s).
Bulb cleaning is recommended as routine maintenance quarterly or every three months. Use the UV Bulb Cleaning
Reminder Schedule, Fig. 10, to help you establish and track your regular cleaning schedule.

UV BULB CLEANING REMINDER SCHEDULE

INSTALLATION DATE: (month) , (year)

YEAR J F M A M J J A S O N D

M13516A

Fig. 10. UV bulb cleaning reminder schedule.


CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing ultraviolet bulb(s).

To clean your bulb:

  1. Disconnect the power to your heating and cooling system.
  2. Unplug or turn off power to your UV system and allow the bulb to cool for at least 15 minutes.
  3. Rotate your lamp handle counterclockwise and gently pull the lamp handle to remove the bulb(s).
    See Fig. 11.
    Fig. 11. Remove lamp or bulb.
  4. Holding the lamp handle, wipe the lamp glass using a soft cloth dampened with window cleaner. If you
    touch the lamp glass with your hands, be sure to clean the area of any oils left from bare hands. See Fig. 12.
    Fig. 12. Clean glass with a soft cloth.
  5. Also, wipe away any dust that may have collected between the lamplight indicator on the base and the black lamp base. See Fig. 13.
    Fig. 13. Wipe lamp light indicator base.
  6. Dry bulbs with a clean, dry cloth.
  7. Insert the lamp handle into the base with the lamp light indicator at the eleven o’clock position. Continue pushing and gently rotating counterclockwise until the lamp handles insert fully into the base. See Fig. 14.
    Fig. 14. Position lamp handles for insertion back into the lamp base.
  8. Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 15.
    Fig. 15. Snap lamp handle into place.
    WARNING
    UV Light Hazard.
    Harmful to bare skin and eyes.
    Can cause temporary or permanent loss of vision.
    Never look at bulbs while illuminated.
    View illumination only through the lamplight indicator located on the lamp handle.
    To prevent exposure to ultraviolet light, disconnect power to the ultraviolet system before servicing any part of the heating and air conditioning system.
  9. Reconnect power to your UV System.
  10. For Air Treatment Systems, wait ten minutes for the airflow sensor to calibrate. During this time, the furnace fan must remain off.
    NOTE: Failure to wait ten minutes for the airflow sensor to calibrate before powering the system fan causes the airflow sensor to incorrectly calibrate and the device to incorrectly function. If this occurs, remove power to the furnace or turn off the system fan, wait ten minutes, and then resume normal fan operation.
  11. Verify that the ultraviolet lamp is operating by viewing only through the lamplight indicator on the lamp handle. Never look directly at your bulbs while illuminated.
  12. Reconnect power to your heating and cooling system.

CAUTION
UV Lamp Burn Hazard.
Harmful to bare skin.
Can cause severe burns.
Disconnect power 15 minutes before removing ultraviolet bulb(s).

Bulb Replacement
Replacement of the bulb in your ultraviolet lamp when the LED is solidly lighted is required to maintain effectiveness.

  1. Obtain the correct replacement bulb for your unit. See Table 1.
    Table 1. Select a Replacement Bulb/Handle Assembly or Replacement Bulb.
    Unit Description Replacement Bulb/Handle Assembly SnapLamp™ Replacement Bulb
    UV100E1043
    Air Treatment System
    UC100E1006 UC18W1004
    UV100E2009
    Air Treatment System
    UC100E1030 (two required) UC36W1006 (two required)
    UV100E3007
    Surface Treatment System
    UC100E1030 UC36W1006
  2. Disconnect power to your heating and cooling system.
  3. Unplug or turn off power to your UV System and allow the lamp to cool for at least 15 minutes.
  4. Rotate the lamp handle counterclockwise and gently pull the lamp handle to remove the bulb(s). See Fig. 11.
  5. If you have a SnapLamp™ handle, follow step 5 and otherwise, proceed to step 7. Grasp the SnapLamp™ handle in one hand and the lamp glass in the other and pull straight apart. See Fig. 16.
    Fig. 16. Disconnect lamp glass from SnapLamp™ handle.
  6. Insert the new lamp glass into the SnapLamp™ handle by aligning the notch and pushing straight together. See Fig. 17.
    Fig. 17. Replace lamp glass in SnapLamp™ handle.
  7. Insert the lamp handle into the base with the lamp light indicator at the eleven o’clock position. Continue pushing and gently rotating counterclockwise until the lamp handles insert fully into the base. See Fig.4.
  8. Rotate the lamp clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 6.
  9. Reconnect power to your UV System.
  10. For UV Air Treatment Systems, wait ten minutes for the airflow sensor to calibrate. During this time, the furnace fan must remain off.
    NOTE: Failure to wait ten minutes for the airflow sensor to calibrate before powering the system fan causes the airflow sensor to incorrectly calibrate and the device to incorrectly function. If this occurs, remove power to the furnace or turn off the system fan, wait ten minutes, and then resume normal fan operation.

    WARNING
    UV Light Hazard.
    Harmful to bare skin and eyes.
    Can cause temporary or permanent loss of vision.
    Never look at bulbs while illuminated.
    View illumination only through the lamplight indicator located on the lamp handle.
    To prevent exposure to ultraviolet light, disconnect power to the ultraviolet system before servicing any part of the heating and air conditioning system.
  11. Verify that your ultraviolet lamp is operating by viewing only through the lamplight indicator on the lamp handle. Never look directly at your bulb while it is illuminated.
  12. Reconnect power to your heating and cooling system.
  13. Press and hold the reset button for five seconds to reset the internal timers.
  14. PARTS LIST

    System Description

    Replacement Bulb/Handle Assembly

    Replacement Bulb

    UV100E1043
    Air Treatment System (single-lamp) (left photo)
    UC100E1006 UC18W1004
    UV100E3007 Surface Treatment System (center photo) UC100E1030 UC36W1006
    UV100E2009 Air
    Treatment System (dual lamp) (right photo)
    UC100E1030 (two required) UC36W1006 (two required)

    Choose better indoor air for your family by installing Honeywell Home solutions. You’ll enhance your comfort and peace of mind.

    Ultraviolet Air Treatment Systems
    Zap airborne germs and prevent mold spore growth on air conditioning coils
    Whole-House Air Cleaners Trap a high percentage of airborne particles of the air passing through it
    Whole-House Humidifiers Moisturize air—40% to 60% humidity is ideal for minimizing adverse health effects
    Zoning Systems Control temperature by area in your home, saving energy and improving comfort
    PerfectWindow® Air Exchangers
    Ventilate your home to assure fresh air while minimizing energy loss
    Programmable Thermostats Save up to 30% in annual energy costs with this easy-to-use thermostat*
    * depending on geography and usage M18621C

    UV100E ULTRAVIOLET SYSTEMS

    INSTALLATION TEMPLATE FOR AIR TREATMENT SYSTEM (SINGLE-LAMP).
    Fig. 18. Air Treatment System (single lamp) template.
    (Air Treatment System (dual lamp) template is located on the next page.)
    Fig. 19. Air Treatment System (dual lamp) template.

    Fig. 20. Surface Treatment System template.


    www.resideo.com

    Resideo Technologies, Inc.
    1985 Douglas Drive North, Golden Valley, MN 55422
    1-800-468-1502
    68-0262—09 M.S. Rev. 03-21 | Printed in the United States

    © 2021 Resideo Technologies, Inc. All rights reserved.
    The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.