Miele Vented Dryer PDR 908 EL Instruction Manual

Miele Vented Dryer PDR 908 EL Instruction Manual

Legend:

Connection required

  • AL:  Exhaust air
  • ASK:  Condensate drain hose
  • B:  Machine anchoring
  • EL:  Electrical connection
  • F: Machine feet, adjustable
  • KG:  Payment system
  • KGA:  Payment system connection
  • KLA:  Cooling air vent

Connection optional or required, depending on model

  • KLZ:  Cooling air intake
  • PA:  Potential equalization
  • SLA:  Peak-load connection
  • UG:  Closed base
  • UO:  Open base
  • APCL:  Washer-dryer stacking kit
  • XKM:  Communication module
  • ZL:  Air intake

Machine dimensions

Installation


Washer-dryer stack

Technical data

Drying system Vented
Drum volume l 130 (4.59 ft3)
Capacity kg 8.0 (17.6 lb)
Door opening diameter mm 370 (17 9/16 in)

Electrical connection ( EL)

Standard voltage for CDN & USA 2 AC 208-240 V
Frequency Hz 60
Total rated load kW 3.2/4.3
Fuse rating A 2 x 30
Supply cable min. cross-section   3 x AWG10
Supply cable with plug type NEMA L6-30P  
Length of supply cable mm 1,830 (6.0 ft)
Non-standard voltage MAR 208-240 (Marine) 2 AC 208-240 V
Frequency Hz 60
Total rated load kW 3.2/4.3
Fuse rating A 2 x 30
Supply cable min. cross-section   3 x AWG10
Supply cable with plug type NEMA L6-30P  
Length of supply cable mm 1,830 (6.0 ft)

Vented ( EL)

Connection (ext. diameter) mm 100 (3 15/16 in)
Max. exhaust air temperature °C 80 (176°F)
     
Electrical connection with 50 Hz/60 Hz    
Max. permissible pressure loss Pa 340 (0.049 psi)
Max. flow rate w/o counterpressure (0 Pa) in vented mode m³/h 285 (10.064 ft3/h)

Potential equalization ( PA)

Appliance connection (with installation kit)  
     
XCI box interface  

Peak load/ energy management ( SLA)

Machine connection (with XCI box)  
Communication module ( XKM)                                         
Communication module XKM 3200 WL PLT  

Installation on machine feet ( F)

No. of machine feet No. 4
Machine foot, height-adjustable with thread mm ± 5 (3/16 in)
Machine foot diameter mm 31.7 (1 1/4 in)

Anchoring ( B)

Anchoring of Miele bases

Miele base installation (fasteners included)   Ο
Required anchor points No. 4
Wood screws according to DIN 571 mm 8 x 65

(5/16 x 2 9/16 in)

Rawl plugs (diameter x length) mm 12 x 60 (1/2 x 2 3/8 in)

Base floor anchoring (to be provided on site)

Machine installation on on-site base(concrete or masonry)   Ο
Min. base installation footprint (W/D) mm 600/650 (23 5/8 x 25 9/16 in)
Wood screws according to DIN 571 mm 6 x 50 (1/4 x 2 in)
Rawl plugs (diameter x length) mm 8 x 40 (5/16 x 1 9/16 in)

Machine data

Overall machine dimensions (H/W/D) mm 850/605/717 (33 7/16 / 23 13/16 / 28 1/4 in)
Casing dimensions (H/W/D) mm 850/596/677

(33 7/16 / 23 7/16 / 26 5/8 in)

Site-access dimensions (H/W)
Min. site-access opening (excl. packaging) mm 900/605 (35 7/16 / 23 13/16 in)

Installation dimensions

Min. side gap mm 20 (13/16 in)
Recommended side gap – washer-dryer stack mm 300 (11 13/16 in)
Min. distance to opposite wall from front of machine mm 950 (37 3/8 in)
Recommended distance to opposite wall from front of machine mm 1,100 (43 5/16 in)

Weights and floor loads

Machine weight (net weight) kg 51.5 (113.6 lb)
Max. floor load in operation N 670

Emissions

Sound pressure level (in accordance with EN ISO 11204/11203) dB(A) < 70
Heat dissipation rate to installation site W 200

Installation and planning notes

Installation requirements

The tumble dryer should only be connected to a power supply provided in accordance with all appropriate local and national legislation and regulations.

In addition, all regulations issued by the appropriate utilities as well as standards relating to occupational safety and all applicable valid regulations and technical standards must be observed.

General operating conditions

Ambient temperature in installation room: +2°C to +35°C (36°F to 95°F).

Electrical connection

This tumble dryer is supplied with a power cord and plug ready for connection.

The machine may only be connected to an electrical system that conforms to the national and local codes and regulations. The  installation must be performed by a qualified electrician.

The data plate indicates the nominal power consumption and the appropriate fuse rating. Compare the specifications on the data plate with those of the electrical power supply

The tumble dryer can either be hard-wired or connected using a plugand-socket connection in accordance with IEC 60309-1. It is always recommended to connect the machine via a plug and socket so that electrical safety checks, e.g. during repair or service work, can be carried out easily.

If the machine is hard-wired, a dual circuit breaker must be provided on site. When switched off, there must be an all-pole contact gap of at least 3 mm in the isolator switch (including circuit breakers, breakers, and relays according to IEC/EN 60947).

The plug connector or isolator switch should be easily accessible at all times. If the tumble dryer is disconnected from the electricity supply, the isolator must be lockable or the point of disconnection must be monitored at all times.

New connections, modifications to the system, or servicing of the ground conductor, including determining the correct fuse amperage, must be carried out by a qualified electrician, as they are familiar with the pertinent regulations and the specific requirements of the electric utility company.

If converting the tumble dryer to an alternative voltage, observe the instructions in the wiring diagram. Conversion must be performed by Miele Service or by an authorized Miele dealer. The heater rating must also be adapted.

The tumble dryer must not be connected to devices such as timers which would switch it off automatically.

References to cable cross-sections in the technical data refer only to the required power cord. Please consult relevant local and national regulations when calculating any other wire gauges.

Vent connection

Hot moist exhaust air should be vented to atmosphere along the shortest possible route or connected to a suitable vent system.

Depending on the duct path, the moist exhaust air can condense on the duct walls to a greater or lesser extent. For this reason it is recommended to lay ducting with a downwards slope to the air exit.
If ducting slopes upwards, a condensate trap either with a drip tray or a connection to a suitable on-site floor drain must be fitted in the system at the lowest point.

Condensate must not flow back into the machine.

It is permissible to vent exhaust air via an external wall. In this case, measures must be taken to minimize the risk and annoyance to neigh bouring buildings.

The end of exhaust air ducting leading into the open should be protected against the elements, e.g. using a suitable hood or grille or with a 90° bend.

The cross-sectional area of the ducting must not be reduced or obstructed by built-in parts. Filters and louvers must not be fitted in the ducting.

Congestion in the line may lead to a drop in machine performance or to machines being switched off to guarantee safety.

Proper functioning of the tumble dryer cannot be guaranteed if the max. permissible pressure loss is exceeded in the on-site vent ducting system.

When connecting several tumble dryers to a common duct, the crosssectional area of the duct must be increased accordingly.

Additionally, in such a case every tumble dryer must have its own non-return valve to prevent dryers affecting others in the system. This requires the provision of on-site additional parts.

In the event that exhaust air ducts from several tumble dryers are merged into a common duct, a non-return device should be installed in each separate line to prevent backflow.

With complex ducting with many bends and additional components, or with the connection of several different machines to a common duct, it is recommended that a detailed calculation is carried out by a suitable specialist.

Air intake

The air supply for the tumble dryer is taken directly from the installation site.

During operation, adequate ventilation of the installation site should be guaranteed. Depending on the machine version, it is necessary to ensure an intake of fresh air to compensate for the volume of exhaust air extracted in order to avoid the creation of a vacuum

It should not be possible to close or otherwise obstruct air intake grilles or alternative measures should be implemented to ensure that an adequate supply of fresh air is available at all times during tumble dryer operation.

Potential equalization

If necessary, potential equalization with good galvanic contact must be guaranteed in compliance with all applicable local and national installation specifications

Connection material for potential equalization must be provided on site or using a kit available from Miele Service.

Peak load/Energy management

The machine can be connected to a peak load or energy management system using an optional kit.

When the peak-load function is activated, the heating is deactivated.
A message appears in the display to inform you of this.

Interface

The tumble dryer can be retrofitted with an XKM 3200 WL PLT communication module.

This module can be used as a WiFi or LAN interface.

The LAN interface provided via the module complies with SELV (Safety Extra Low Voltage) in accordance with EN 60950. Connected appliances must also comply with SELV. The LAN connection uses a RJ45 connector in accordance with EIA/TIA 568-B.

Installation and anchoring

The machine must be installed on a perfectly smooth, level and firm surface which is able to withstand the quoted loads.

The floor load created by themachine is concentrated and transferred to the installation footprint via the machine feet.

The tumble dryer should be levelled in both directions with the aid of the adjustable feet.

Base installation

The tumble dryer can be installed on a machine base (open or box base, available as an optional Miele accessory) or on a concrete base to be provided on site.

The quality of the concrete and its strength must be assessed according to the machine load. Ensure that any raised concrete base is adequately bonded to the floor below.

Washer-dryer stack

The tumble dryer can be installed as a washer-dryer stack together with a Miele Washing Machine. A stacking kit (optional accessory) is required for this.

Installation of the stacking kit must be performed by Miele Service or an authorized Miele service technician.