Honeywell BW Flex Series Portable Multiple Gas Detector User Guide

QUICK
REFERENCE GUIDE

Honeywell BW ™ Flex Series
Portable Multiple Gas Detector
© 2020 October 23
M05-4002-001-Rev A

Introduction
The Honeywell BW™ Flex gas detector warns of hazardous gas at levels above user-defined alarm setpoints.
The detector can monitor up to four gases at a time.
Refer to the Honeywell BW™ Flex Series User Manual for the full list of gases.
What’s in the Box
• Honeywell BW™ Flex gas detector
• Quick Reference Guide
• Battery (factory-installed)
• Tubing
• USB charger
• 1 Klick Fast stud
• 1 Calibration cap

 CAUTION
• The detector is a personal safety device. It is your responsibility to respond properly to the alarm.
• For safety reasons, this equipment must be operated and serviced by qualified personnel only.
• The Li-ion battery in this product presents a risk of fire, explosion, and chemical burn if misused. Do not disassemble, incinerate, or heat above 212°F (100°C). Batteries exposed to heat at 266°F (130°C) for 10  minutes can cause fire and explosion. Batteries must only be charged in a safe area free of hazardous gas.
•  Deactivating the detector by removing the battery pack may cause improper operation and harm the detector.
• Use only Honeywell-approved battery chargers such as the vehicle Charger.
• Do not use the apparatus if it is damaged. Inspect the apparatus before use. Look for cracks and missing parts.

Overview

1 LED Alarm
2 IntelliFlash
3 Display
4 Button,
5 Beeper

6 .Sensor,
7. Clip
8. Battery
9 . Charging Port
Common device’s operations

Power On 4-second hold
Power Off 4-second hold
Enter Menu Double-press
Exit Menu 3-second Hold
Select Next Single-press
Initiate Selected 3-second Hold
Acknowledge latched alarm 1-second hold

Bump Test and Calibration via a Mobile Device
Turn On the BW Flex. Place the cap over the detector, and then press down on both tabs to snap it into place.

3. On your mobile device, open the Device Configurator app

4. In the Device List screen, select the BW Flex Serial Number to start pairing. The upper LED will light green after pairing succeed.
5. On your Mobile device:
• Tap on the Menu button
• Select Remote Calibration
• Follow on-screen instructions.
6 . The process is complete when the results are displayed on your mobile device. You can now remove the cap by pulling on the tabs.

IMPORTANT: Read the User Manual for complete information on the BW Flex operation.

Safety Certifications

IECEx: IECEx SIR 20.0020X
With IR sensor installed: Ex ia op is I Ma Ex ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
With LEL sensor installed: Ex da ia I Ma Ex da ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
With IR and LEL sensor installed: Ex da ia op is I Ma Ex da ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
Without IR and LEL sensor installed: Ex is I Ma Ex is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
ATEX: Sira 20ATEX2012X
With IR sensor installed: I M1 Ex is op is I Ma, -40°C≤ Tamb ≤ 60°C
II 1G Ex ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
With LEL sensor installed: I M1 Ex da is I Ma, -40°C≤ Tamb ≤ 60°C
II 1G Ex da ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
With IR and LEL sensor installed: I M1 Ex da is op is I Ma, -40°C≤ Tamb ≤ 60°C
II 1G Ex da ia op is IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
Without IR and LEL sensor installed: I M1 Ex is I Ma, -40°C≤ Tamb ≤ 60°C
II 1G Ex ia IIC T4 Ga, -40°C≤ Tamb ≤ 60°C
RED: RED Directive 2014/53/EU
EMC: Directive 2014/30/EU
ROHS Directive (EU) 2015/863 amending 2011/65/EU
IP: IP66, IP68 (1.2 meters for 45 minutes)

Contact Us
Europe, Middle East, Africa
Life Safety Distribution GmbH
Toll-Free 00800 333 222 44
Middle East +971 4 450 5800
Middle East +971 4 450 5852
(Portable Gas Detection)

Americas
Honeywell Analytics
Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363

www.honeywellanalytics.com
Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700

Technical Services
EMEA:
US: ha.us.
AP: ha.ap.

https://safety.honeywell.com/en-us/products/by-category/gas-flame-detection