ABB ATT-VZN Ability Smart Sensor Bluetooth SIM Card Gateway Installation Guide

ABB Ability™ Smart Sensor Bluetooth®
ATT-VZN SIM card ready gateway
INSTALLATION MANUAL

General

The ABB Ability Smart Sensor ATT-VZN SIM card ready gateway is used to upload the Smart Sensor data automatically to the Smart Sensor portal. The gateway needs to be configured for Internet access before it can start reading the Smart Sensors. This gateway uses a 3G/4G Mobile network with the included USB dongle for internet connection.
The sales package includes:

  • X1000 Bluetooth router, wall and pole mounting kits, and a quick guide.
  • MultiTech Modem with antennas.
  • PROCESS PoE Injector power supply, with power cord.
  • 10 Ft. Cat 5 ethernet cable with 90-degree connector.

1. X100 router (1)
2. Pole mounting straps (2)
3. Anchors with screws (2×4)
4. Silicon plugs (4)
5. Mounting bracket (1)
6. Power cord (1)
7. Procet PoE injector (1)
8. Ethernet cable (1)
9. MultiTech modem with antennas (1)
10. Quick start guide (1)

For general information about the Cassia gateway, please refer to the Cassia User Manual on https://www.cassianetworks.com/download/docs/Cassia_User_Manual.pdf

Installation

Prerequisites for installation
Internet connection:
The mobile network needs to have adequate signal strength.
AC – Access Controller

Smart Sensor Platform

Power supply:
110/115 vac grounded outlet to accept P0E injector power cord.
SIM card:
ATT or Verizon Micro-SIM card (see next page for supported SIM cards)
Computer:

  • A computer with a WIFI adapter is needed for gateway configuration. A tablet computer or mobile phone can also be used.
  • Google Chrome web browser is recommended to be used.

Mounting:

  • Flathead screwdriver for pole mounting.
  • Phillips head screwdriver and a drill (if needed) for wall mounting.
  • Mounting is not mandatory, but it is recommended to secure the gateway somehow to its intended place.

Recommended location

Height:
The recommended height for the gateway is 10-98 feet from ground level. Lower levels are also acceptable, but the gateway Bluetooth range might be shorter due to obstacles.
Orientation:
The gateway has the best reception in the direction where the Cassia logo is shown on its side. If the gateway has trouble connecting to a specific Smart Sensor, it is recommended to rotate the gateway to point in that direction.

Obtaining the correct SIM card

The MultiTech Modem uses a Micro-SIM-sized sim card, slightly larger than a nano sim card.

SIM card installation
The sim card is correctly installed when:

  • Inserted, it depresses an internal spring until it clicks into place.
  • The angled cut of the sim card is facing the right side of the modem.
  • It is facing toward the slot into which it is to be inserted.
  • The “logo” side (non-circuit side) of the SIM card is also facing outward toward the operator, the same as the label side of the modem.

Gateway configuration
When the gateway is powered on, the blue LED at the bottom of the gateway turns ON. After bootup, the gateway will turn on the configuration WIFI hotspot. The bootup takes about 30-60 seconds.
Configuration WIFI hotspot has SSID “cassia-XXXXXX”, where XXXXXX is the last 6 digits of the gateway’s MAC address. MAC address can be found at the bottom of the gateway. The password for this WIFI hotspot is the same as the SSID.
Connect to this WIFI hotspot with the device used for configuration (computer, phone, or tablet) and open the web browser. Type 192.168.40.1 to the web browser’s address field and press enter. Cassia configuration page will open. During the first login, the default password needs to be changed. Default
credentials are:

  • Login: admin
  • Password: admin

Cassia login page

It is recommended to replace the default credentials.
Once logged in, the Status Page is shown. This page shows the current operation mode and connection status of the gateway.AC Online Time shows how long the gateway has been connected to the AC (Access Controller) server. If no time is shown, it means that the gateway does not have a connection to the AC server.
Access Controller server connection is needed for the Smart Sensor data transfer.

Status page

The Basic Page is where the configuration is done. Following values are needed:

  • AC Server Address: gw.smartsensor.abb.com
  • Remote Assistance: ON
  • Router Mode: AC Managed Router
  • AC Router Comm. Ports: 5246, 5247

Connection Priority is where a priority connection method is selected.

Basic page

AT&T mobile network configuration

The following items are required for AT&T mobile network configuration:

  • PROCESS PoE injector as the power supply (included in the sales package)
  • MultiTech MTCM-LNA3-B03 USB modem (included in the sales package)
  • AT&T SIM card (purchased) From the Gateway Basic Page:
  • Select as Connection Priority: 3G/4G
  • Select for USB Dongle Type: MultiTech MTCMLNA3-B03 for AT&T
  • Type or confirm APN: 10569.MCS
  • Type or confirm Service: UMTS
  • Type or confirm Dial Number: *99***1#
  • Type or confirm Device: /dev/ttyACM0
  • Select Peer DNS: 1

Press Apply at the bottom of the screen.
From the Gateway another page:

  • Scroll down to the Actions section.
  • Click on the Reboot button.
  • Wait for the reboot to finish.

NOTE! With a USB dongle, the gateway needs to be in a place where there is good network coverage.

AT&T mobile network configuration

Verizon mobile network configuration

The following items are required for Verizon mobile network configuration:

  • PROCESS PoE injector as the power supply (included in the sales package)
  • MultiTech MTCM-LNA3-B03 USB modem (included in the sales package)
  • Verizon SIM card (purchased)

From the Gateway Basic Page:

  • Select as Connection Priority: 3G/4G
  • Select for USB Dongle Type: MultiTech MTCMLNA3-B03 for Verizon
  • Type or confirm APN: VZWINTERNET
  • Type or confirm Service: UMTS
  • Type or confirm Dial Number: *99***1#
  • Type or confirm Device: /dev/ttyACM0
  • Select Peer DNS: 1

Press Apply at the bottom of the screen.
From the Gateway another page:

  • Scroll down to the Actions section.
  • Click on the Reboot button.
  • Wait for the reboot to finish.

NOTE! With a USB dongle, the gateway needs to be in a place where there is good network coverage.

Verizon mobile network configuration

Gateway configuration confirmation
Confirm gateway is connected properly by contacting Smart Sensor support:

  • By email in the US:
  • By phone in the US: +864-284-5700 Ext 6
  • Email outside the US:

You should see data moving automatically from your smart sensors in the range of your gateway to the Smart Sensor portal, within 60 – 90 minutes.

Troubleshooting

For AT&T configuration:
If 10569. MCS APN does not work, please try the APN: m2m.com.attz
For Verizon configuration:
If VZWINTERNET APN does not work, please try the APN: wyleslte.gw7.vzwentp

ABB Motors and Mechanical Inc.
5711 R.S. Boreham, Jr. Street
Fort Smith, AR 72901
Ph: 1.479.646.4711
new.abb.com/motors-generators