Samsung AJ020RBNDEG Air conditioner User Manual
User manual
AJ***RBNDEG
- Thank you for purchasing this Samsung air conditioner.
- Before operating this unit, please read this user manual carefully and retain it for future reference.
Safety Information
- Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and may also void the warranty on the installed product.
Install a switch and circuit breaker dedicated to the air conditioner. - Failing to do so may result in electric shock or fire.
Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed. - Failing to do so may result in electric shock or fire, explosion, or problems with the product.
- This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high external wall where it could fall. - If the outdoor unit falls, it may result in injury, death, or property damage.
• Failure to do so may result in electric shock, fire, an explosion, or other problems with the product.
• Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes.
- Failing to do so may result in abnormal vibrations, noise, or problems with the product.
Install the drain hose properly so that water is drained correctly. - Failing to do so may result in water overflowing and property damage.
Avoid adding drains to waste pipes as odors may arise in the future.
The product shall be stored in a room with no ignition sources (e.g. open flames, gas appliance, electric heater, etc.) - Note that the refrigerant has no odor.
When installing the outdoor unit, make sure to connect the drain hose so that draining is performed correctly. - The water generated during the heating operation in the outdoor unit may overflow and result in property damage.
In particular, in winter, if a block of ice falls, it may result in injury, death, or property damage.
Do not install the product in a place where thermo-hygrostat is needed (such as server room, machinery room, computer room, etc.) - Those places do not provide guaranteed operation conditions for the product therefore performance can be poor in these places.
FOR POWER SUPPLY
WARNING
- This may result in electric shock or fire.
- Failing to do so may result in electric shock or fire.
FOR USING
- Failing to do so may result in electric shock or fire.
If the appliance generates a strange noise, a burning smell, or smoke,
Safety Information
unplugs the power plug immediately and contacts your nearest service center.
- Failing to do so may result in electric shock or fire. In case of a malfunction, immediately stop the operation of the air conditioner and disconnect the entire power system. Then consult the authorized service personnel. In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line
- Do not use a ventilating fan
- A spark may result in an explosion or fire. To reinstall the air conditioner, please contact your nearest service center
- Failing to do so may result in problems with the product, water leakage, electric shock, or fire.
- A delivery service for the product is not provided. If you reinstall the product in another location, additional construction expenses and an installation fee will be charged.
- Especially, when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to salt in the air, please contact your nearest service center.
- This may result in electric shock. Do not turn the air conditioner off with the circuit breaker while it is operating.
- Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire. After unpacking the air conditioner, keep all packaging materials well out of the reach of children, as packaging materials can be dangerous to children.
- If a child places a bag over its head, it may result in suffocation. Do not touch the front panel with your hands or fingers during the heating operation.
- This may result in electric shock or burns. Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating or the front panel is closing.
- Take special care that children do not injure themselves by inserting their fingers into the product.
Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner. - Take special care that children do not injure themselves by inserting their fingers into the product.
Do not strike or pull the air conditioner with excessive force. - This may result in fire, injury, or problems with the product.
Do not place an object near the outdoor unit that allows children to climb onto the machine. - This may result in children seriously injuring themselves.
Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people. - Since this may be dangerous due to a lack of oxygen, open a window at least once an hour.
- Failing to do so may result in electric shock or fire.
- Do not use any fuse (such as copper, steel wire, etc.)other than the standard fuse.
- Failing to do so may result in electric shock, fire, problems with the product, or injury.
- Water dripping from the indoor unit may result in fire or property damage.
Check that the installation frame of the outdoor unit is not broken at least once a year. - Failing to do so may result in injury, death or property damage.
Max current is measured according to IEC standards for safety and current is measured according to ISO standards for energy efficiency. When the air conditioner does not operate properly for cooling or heating, there is a possibility of refrigerant leakage. If any leakage, stop operation, ventilate the room, and consult your dealer immediately for recharging refrigerant.
The refrigerant is not harmful. However, if it comes in contact with fire, it may generate harmful gases and there is a risk of fire.
During the transportation of the indoor unit, the pipelines shall be covered with brackets for protection. Do not move the product withholding the pipelines. - It may cause gas leakage.
Do not install the product in a ship or a vehicle (such as a campervan). - Salt, vibration or another environmental factor may cause the product malfunction, electric shock or fire.
Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.)
on the appliance.
• This may result in electric shock, fire, problems with the product, or injury.
Do not operate the appliance with wet hands. - This may result in electric shock.
Do not spray volatile material such as insecticide onto the surface of the appliance. - As well as being harmful to humans, it may also result in electric shock, fire or problems with the product.
Do not drink the water from the air conditioner. - The water may be harmful to humans.
Do not apply a strong impact to the remote controller and do not disassemble the remote controller. Do not touch the pipes connected with the product. - This may result in burns or injury.
Do not cut or burn the refrigerant container or pipings.
Do not point the air directly to the fireplace or heater.
Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes. - This may result in property damage.
Avoid directly exposing humans, animals or plants to the airflow from the air conditioner for long periods of time. - This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNING
Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner, alcohol or acetone to clean the appliance.
- This may result in discoloration, deformation, damage, electric shock or fire.
Before cleaning or performing maintenance, unplug the air conditioner from the wall socket and wait until the fan stops. - Failing to do so may result in electric shock or fire.
- To avoid cutting your fingers, wear thick cotton gloves when cleaning it.
- This should be done by a qualified technician please contact your installer or service center.
- For cleaning inside the appliance, contact your nearest service centre.
- When cleaning the internal filter, refer to the descriptions in the ‘Cleaning and Maintaining’ section.
- Failure to do may result in damage, electric shock or fire.
- Make sure to prevent any injury from sharp edges of the surface when handling the heat exchanger.
Indoor Unit Overview
The indoor unit and its display may look slightly different from the illustration shown below, depending on the model and the panel type.
01 Display
02 Air flow blade/Air outlet (inside) / Wind-Free panel
(You can use the Wind-Free Cooling function when the Cool, Dry, or Fan mode is running.)
(Refer to the remote control manual for product operation.)
03 Air intake
04 Air filter (under the grille)
Operation Features
Operating temperature and humidity
When using the air conditioner follow the operating temperature and humidity ranges.
Mode | Outdoor
temperature |
Indoor
temperature |
Indoor
humidity |
If out of conditions |
Cool mode |
Depending on the outdoor unit specifications |
16˚C to 32˚C | 80% or less | Condensation may occur on the indoor unit with the risk to have other water blow off or drop on the floor. |
Heat mode |
27˚C or less | – | Internal protection triggers and the air conditioner will stop. | |
Dry mode |
18˚C to 32˚C | – | Condensation may occur on the indoor unit with the risk to have ither water blow off or drop on the floor. |
CAUTION
- If you use the air conditioner at a relative humidity above 80%, it may cause a formation of condensation and a leakage of water on the floor.
- The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature conditions. If the cooling operation is used at over 32˚C (indoor temperature), it does not cool at its full capacity.
- If the indoor unit is out of the operating temperature and humidity range, the safety device may operate and the air conditioner may stop.
Cleaning and Maintaining
Before cleaning the indoor unit, be sure to turn off the auxiliary power switch.
Cleaning the indoor unit exterior
Wipe the surface of the unit with a slightly wet or dry cloth when needed. Wipe off the dirt of odd-shaped areas by using a soft brush.
CAUTION
- Do not use alkaline detergent, sulphuric acid, hydrochloric acid, or organic solvents (such as thinner, kerosene, and acetone) to clean the surfaces.
- Do not attach any stickers on the surfaces because this may cause damage.
- When you clean the heat exchanger on the indoor unit, you need to disassemble the indoor unit. Therefore, you must contact the local service center for help.
Cleaning the outdoor unit heat exchanger
CAUTION
- The heat exchanger of the outdoor unit has sharp edges. Take care when cleaning its surface.
NOTE
- If it is difficult to clean the heat exchanger of the outdoor unit, contact the local service center.
Cleaning the air filter
CAUTION
- Be sure to hold the grille with a hand to prevent dropping from the opening of the front grille.
- Detaching the air filter Push down the hooks at each side of the front grille to open the grille.
NOTE
• The hooks are located on both sides of the front grill with the Samsung logo.
Pull out the air filter from the indoor unit - Cleaning the air filter
Clean the air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with running water and dry it in a ventilated area. CAUTION
Do not scrub the air filter with a brush or other cleaning utensils. This may damage the filter. NOTE
• If the air filter dries in a humid area, it may produce offensive odors. Clean it again and dry it in a well-ventilated area.
• The cleaning period may differ depending on the usage and environmental conditions, so clean the air filter every week if the indoor unit is in a dusty area. - Reassembling the air filter
CAUTION
• If the indoor unit is used without the air filter, the indoor unit may be damaged due to dust. - Resetting the air filter (Wired remote control is an optional item)
After cleaning and reassembling the air filter, be sure to reset the filter-cleaning reminder as follows:
• Indoor unit with the wired remote control: Press the Filter Reset button.
• Indoor unit with the wireless remote control: Press the Options button → < or > → (Filter Reset) Blinking → press the SET button.
NOTE
• The filter reset indicator blinks when the air filter should be cleaned.
• If the angle of the airflow blade is changed by opening the front grille for installation or maintenance of the indoor unit, be sure to turn it off and then on the auxiliary switch before operating the indoor unit again. If not, the angle of the airflow blade may be changed and the blades may not be closed after turning off the indoor unit.
Periodical maintenance
Unit | Maintenance item | Interval | Requires qualified
technicians |
Indoor unit |
Clean the air filter. | At least once a month | |
Clean the condensate drain pan. | Once a year | Reg u i red | |
Clean up the heat exchange. | Once a year | Required | |
Clean the condensate drain pipe. | Once every 4 months | Required | |
Replace the remote control batteries. | At least once a year | ||
Outdoor unit |
Clean the heat exchanger on the outside of the unit. | Once every 4 months | Required |
Clean the heat exchanger on the inside of the unit. | Once a year | Required | |
Clean the electric components with jets of air. | Once a year | Required | |
Verify that all the electric components are firmly tightened. | Once a year | Required | |
Clean the fan. | Once a year | Required | |
Verify that the fan assemblies are firmly tightened. | Once a year | Required | |
Clean the condensate drain pan. | Once a year | Required |
Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expense.
Problem | Solution |
The air conditioner makes a bubbling sound. | • A bubbling sound may be heard when the refrigerant is circulating through the compressor. Let the air conditioner operate in a selected mode.• When you press the Power button on the remote control, noise may be heard from the drain pump inside the air conditioner. |
Water is dripping from the air flow blades. | • Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards. Condensation may generate due to the difference in temperature. |
Remote control is not working. | • Check if your batteries are depleted. • Make sure batteries are correctly installed. • Make sure nothing is blocking your remote control sensor. • Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves. |
The air conditioner does not turn on or off with the wired remote control. | • Check if you set the wired remote control for group control. |
The wired remote control does not operate. | • Check if the TEST indicator is displayed on the wired remote control. If so, turn off the unit and switch off the circuit breaker. Call your nearest contact center. |
The indicators of | • Press the Power button on the remote control to turn the unit off and |
the digital display flashes. | switch the circuit breaker off. Then, switch it on again |
Information about refrigerant
Important information: regulation regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
If the system contains 5 tCO2 e or more of fluorinated greenhouse gases, it must be checked for leakage at least once every 12 months, according to regulation No. 517/2014. his activity must be covered by qualified personnel only. In the case of the situation above, the installer (or authorized erson with responsibility for final check) must provide a maintenance book, with all the information recorded, according to REGULATION (EU) No. 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on fluorinated greenhouse gases.
This indoor unit can be connected to an R-32 or R-410A outdoor unit.
Refrigenat type | GWP value |
R-32 | 675 |
R-410A | 2088 |
• GWP: Global Warming Potential
• Calculating tCO2e: kg x GWP/1000
QUESTIONS OR COMMENTS?
COUNTRY |
CALL |
OR VISIT US ONLINE AT |
UK | 0330 SAMSUNG (7267864) | www.samsung.com/uk/support |
IRELAND (EIRE) | 0818 717100 | www.samsung.com/ie/support |
GERMANY | 06196 77 555 77 *OTH | www.samsung.com/de/support |
FRANCE | 01 48 63 00 00 | www.samsung.com/fr/support |
ITALIA | 800-SAMSUNG (800.7267864) | www.samsung.com/it/support |
SPAIN | 0034902172678 | www.samsung.com/es/support |
PORTUGAL | 808 207 267 | www.samsung.com/pt/support |
LUXEMBURG | 261 03 710 | www.samsung.com/be_fr/support |
NETHERLANDS | 088 90 90 100 | www.samsung.com/nl/support |
BELGIUM | 02-201-24-18 | www.samsung.com/be/support(Dutch) www.samsung.com/be_fr/support(French) |
NORWAY | 21629099 | www.samsung.com/no/support |
DENMARK | 707 019 70 | www.samsung.com/dk/support |
FINLAND | 030-6227 515 | www.samsung.com/fi/support |
SWEDEN | 0771 726 786 | www.samsung.com/se/support |
POLAND | 801-172-678* lub +48 22 607-93-33* Dedykowana infolinia do bsługi zapytań dotyczących elefonów komórkowych: 801-672-678* lub +48 22 607-93-33* * (opłata według taryfy operator) | http://www.samsung.com/pl/support/ |
HUNGARY | 0680SAMSUNG (0680-726-7864) | www.samsung.com/hu/support |
AUSTRIA | 0800-SAMSUNG (0800-7267864) [Only for KNOX customers] 0800 400848 [Only for remium HA] 0800-366661 [Only for Dealers] 0810-112233 [Only for E-Store] 0800 100 232 | www.samsung.com/at/support |
COUNTRY |
CALL |
OR VISIT US ONLINE AT |
SWITZERLAND |
0800 726 78 64 (0800-SAMSUNG) |
www.samsung.com/ch/support (German) www.samsung.com/ch_fr/support (French) |
CZECH | 800 – SAMSUNG (800-726786) | www.samsung.com/cz/support |
SLOVAKIA | 0800 – SAMSUNG (0800-726 786) | www.samsung.com/sk/support |
CROATIA | 072 726 786 | www.samsung.com/hr/support |
BOSNIA | 055 233 999 | www.samsung.com/support |
MONTENEGRO | 020 405 888 | www.samsung.com/support |
SLOVENIA | 080 697 267 (brezplačna številka) | www.samsung.com/si/support |
SERBIA | 011 321 6899 | www.samsung.com/rs/support |
ALBANIA | 045 620 202 | www.samsung.com/al/support |
BULGARIA | *3000 Цена в мрежата 0800 111 31 , Безплатна телефонна линия | www.samsung.com/bg/support |
ROMANIA | *8000 (apel in retea) 08008-726-78-64 (08008-SAMSUNG) Apel RATUIT | www.samsung.com/ro/support |
CYPRUS | 8009 4000 only from landline, toll free | www.samsung.com/gr/support |
GREECE | 80111-SAMSUNG (80111 726 7864) only from land line (+30) 210 897691 from mobile and land line | |
LITHUANIA | 8-800-77777 | www.samsung.com/lt/support |
LATVIA | 8000-7267 | www.samsung.com/lv/support |
ESTONIA | 800-7267 | www.samsung.com/ee/support |
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
For information on Samsung’s environmental commitments and product-specific regulatory obligations, e.g. REACH,
WEEE, Batteries, visit: samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
Suzhou SAMSUNG ELECTRONICS CO., LTD.
501, Suhong East Road Suzhou City, Jiangsu, China
Suzhou SAMSUNG ELECTRONICS CO., LTD. Export.
218, Jiepu Road, Industry Park, Suzhou, Jiangsu ,China
Samsung Electronics
Service Department
PO Box 12987, Blackrock, Co Dublin Ireland or
Blackbushe Business Park, Yateley, GU46 6GG UK