Honeywell 50005625-001 Cover Plate Instruction Manual

Home
50005625-001
Cover Plate Assembly

INSTALLATION INSTRUCTIONS

APPLICATION

Use the 50005625-001 Cover Plate Assembly with T812 and TS812 Thermostats.
Use the 50005625-001Cover Plate Assembly to cover marks on the wall or to mount the thermostat to a 2 in. x 4 in. electrical box.
The 50005625-001 Cover Plate Assembly contains a cover plate, bracket, two #6-32 x 5/8 flat head screws, and two pan head screws. See Fig. 1.

Fig. 1. 50005625-001 Cover Plate Assembly.

INSTALLATION

When Installing this Product…

  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check ratings given in the instructions and on the product to make sure the product is suitable for your application.
  3. Installer must be a trained, experienced service technician.
  4. After installation is complete, check out product operation as provided in these instructions.

CAUTION

Electrical Hazard.

Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.

Mount Cover Plate

Mount Cover Plate Directly to Wall (See Fig. 2)

  1. Pull the wires through the wire hole on the cover plate and subbase.
  2. Position the cover plate and subbase on the wall with the arrows pointing up. Level subbase for appearance only.
  3. Use a pencil to mark the mounting holes for your thermostat.
  4. Remove the cover plate and subbase from the wall and drill two 3/16-in. holes in the wall (if drywall) as marked. For firmer material such as plaster,  drill two 7/32-in. holes. Tap the wall anchors (provided with the thermostat) into the drilled holes until flush with the wall.
  5. Pull the wires through the wire hole on the cover plate and subbase. Position the cover plate and subbase on the wall anchors.
  6. Insert the mounting screws (provided with the thermostat) into the wall anchors. Check to level, if desired, and tighten the mounting screws.

Fig. 2. Mount cover plate, subbase, and thermostat directly to the wall.

Mount Cover Plate to a Vertical 2 in. X 4 in. Electrical Box (See Fig. 3)

  1. Position the bracket on the electrical box. Insert two #6-32 X 5/8 flat head screws. Check to level, if desired, and tighten the flat head screws.
  2. Pull the wires through the wire hole on the cover plate and subbase. Position the cover plate and subbase on the bracket with the arrows pointing up.
  3. Insert two pan head screws and tighten.

Fig. 3. Mount bracket, cover plate, subbase, and thermostat to a vertical 2 in. X 4 in. electrical box.

www.resideo.com
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422 1-800-468-1502
69-1742EFS—01 M.S. Rev. 03-20 | Printed in the United States
50005625-001 COVER PLATE ASSEMBLY

© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.