Philips 36W UVC Disinfection Chamber UVCC090 User Manual

UVCC090 36W UVC Disinfection Chamber Instructions

Standard: IEC60335-1

Technical Parameters

Model UVCC090  UVCCO 90 36W XX(0 1-20)
Dimensions 470440*400mm
Volume 48L
Weight 9.4kg
Power 36W
I nput  Voltage 220-240W-
Frequency 50-601-Iz
Fuse Protection 5A, 250V-
Disinfection Method 253.7 nm, UVC
Operating Temperature Range 10-40°C
Storage Temperature Range -20-60°C
Ambient H umidity  Range 10%-90%
UV Risk Group The risk group of ultraviolet radiation in the disinfection chamber is RG3, and the outside of the chamber is RGO

Structure

Product Installation

Preparation and inspection before installation:

  1.  The installation position must be more than 30cm away from gas appliances, electric heating appliances, or other heat sources, or separated by the board.
  2. Before installation, the strength and surface flatness of the installation place must be checked, and the skew and dislocation of the chamber door shall not appear.
  3. It shall be installed in a place that can bear the weight of the chamber.
  4. When installing, carefully check other factors that may cause the chamber to have malfunctions or accidents.
  5. The impulse current is about 5 amperes, please check electrical capacity.

WARNING:

  1. Please ground reliably so as not to cause electrical shock accidents caused by poor grounding.
  2. Make sure to disconnect the power supply before you move the disinfection chamber.

Instructions for use

  • Scope of application:

Non-medical use. The hard surface of non-medical products, such as mobile phones, mouse of the laptop, keyboard…, etc.

  • Precautions for Use
  1. Take off all packaging material inside the chamber before use;
  2.  In the process of disinfection, If you need to open the door, please press the “stop” button before opening;
  3. The UV light cannot reach the contact part between the item’s lower surface and the tray. If the bottom of the item needs to be completely disinfected, please flip the item up and down once.
  • Requirements for object placement and disinfection plan
  1. Keep a distance of at least 50 mm between the object and the lamp tube, and make sure every surface of the object is exposed to ultraviolet light;
  2. Objects shall not be stacked, and a gap of more than 60 mm shall be maintained between the objects;
  3. Do not put wet objects or objects with spilled liquids into the disinfection chamber;
  4. The disinfection scheme of objects shall be based on the quantity and size of the objects and choose the corresponding placing plan and disinfection time. See the below table for details.
Scenario Min UV irradiance 4LOG disinfection
time
Precaution Illustration
One small box (100mm*I0Omm*I0Omm) 0.96w/m2 (96uw/cm2) 300sec The object is at least 100mm to left/right sides, 50mm to the front/back side.
One big box (200mm*200mm*I50mm) 0.5w/m2 (50uw/cm2) 600sec
3 small box ( 70mm*10Omm*70mm ) 0.4w/m2 (40uw/cm2) 600sec Object to object side keep distance 50mm.
  • Normal disinfection procedures are as follows
  1. Make sure the power plug is plugged properly;
  2. Open the chamber door, put the objects into the disinfection chamber, and place the objects according to the user manual;
  3. Press the “Power” button
  4. Press the Timer to set the disinfection time according to the above disinfection table;
  5. Press the Start button for disinfection. Time for disinfection counts down as seconds;
  6.  During the disinfection process, the remaining time of the disinfection process can be seen through the timer. At the same time, the specific situation in the disinfection chamber can be seen through the perspective window on the door to confirm that all the lamps are working functionally (the perspective window can completely isolate ultraviolet radiation, and there is no need to worry that ultraviolet radiation will penetrate the perspective window);
  7. When the timer returns to zero, the whole disinfection process is finished;
  8.  Take out the objects and close the chamber door, and prepare for the next disinfection.
  • The solution to the lamp tube breakage
    In case of accidental breakage of the lamp tube, it shall be ventilated for 30 minutes first. Please remove the debris with gloves, put it in a sealed plastic bag, and take it to a local waste disposal site for safe disposal.

Precautions

WARNING:

  • Do not operate the UV-C lamp when it is removed from the appliance enclosure.
  • This appliance contains a UV-C lamp.
  • Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin.
  • Appliances that are obviously damaged must not be operated.
  • Read the maintenance instructions before opening the appliance.
  • If UVC products do not work, please contact the dealer for maintenance or replacement rather than the customer.
UV-C RISK GROUP 3

WARNING UV-C
emitted from this product. Avoid eye and skin exposure to unshielded products. Follow installation instructions and user manual.

Switch off the power immediately if the glass is broken accidentally.

  1.  Products are not intended and shall not be used in applications or activities which may cause death, personal injury, and/or damage to the environment
  2. Products not designed and/or intended to be used to disinfect medical devices or for medical purposes; Signify excludes any and all liability for any such improper use.
  3. The UV-C of this product is much stronger than normal sunlight. If you’re exposed to UV-C light, it will cause a severe sunburn on your skin, which can also damage your retina.
  4. Plants and/or materials that are exposed to UV-C and/or ozone for a long time may become damaged and/or discolored.
  5.  Do not put valuables, such as calligraphy and painting, antiques, etc. into the disinfection chamber for disinfection. Signify is not responsible for any related damages.
  6. Children shall be supervised to ensure that they do not play with the appliance. And do not put people, animals, or plants in the chamber.
  7. To avoid the accidental start of UVC lamps, do not carry magnetics close to the control panel when power is on.
  8. Please make sure the glass door is fully closed before starting the disinfection.
  9. Hard objects are prohibited to collide with the UV lamp tube and its shade.
  10. If the UV lamp is damaged, it must be replaced with the Philips lamp tube.(TUV PL-L 18W/4P).
  11. Please use the socket with a rated current above 5A and with a reliable grounding wire.
  12. The power cord is a Y-type connection. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  13. If it is found that the light emitted by the ultraviolet light tube can be seen directly through without any object (such as glass Brocken, etc.), the operation shall be stopped immediately and inform professional maintenance service.
  14. If it is found that abnormal smell, the high temperature on the housing, noise, and smoke), the plug must be disconnected and inform professional maintenance service.
  15. Do not disassemble and repair without permission. It must be repaired by the manufacturer or its maintenance department and other similar professionals.
  16. Do not immerse the disinfection chamber in water or spray water on it.
  17. Objects shall be placed on the tray when doing disinfection.
  18. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

Maintenance

  • Do not spray water on the chamber.
  • Do not let water in the vicinity of the lamp holder.
  • Power off during maintenance or cleaning.
  • When maintenance or cleaning, open the door completely, then take out the shelf.
  • External: the chamber can be cleaned with a wet towel. Strong solvents or detergents are not recommended. But neutral mild cleaners are recommended, no residual cleaners after cleaning.
  • Interior: clean the interior walls with ethanol (reagent grade) and a soft towel to avoid scratching the surface. Be careful not to spray or apply chemicals directly on the UV lamp tube. This may damage the product.
  • Please maintain in strict accordance with the above requirements.

Troubleshooting

 

Fault Phenomenon Possible Causes Processing Method
UVC chamber does not work Bad contact between plug and socket Plugin again
Fuse blow Change the fuse
The power cord was broken Change the power cord
No electricity in the socket Check the power supply line
The door is not closed Close the door
The internal components of the UVC chamber are damaged Contact dealer
UVC lamp does not work The lamp tube is damaged Contact dealer
The PCB board is damaged Contact dealer
Internal wiring problem Contact dealer
The ballast is damaged Contact dealer
The peculiar smell in the disinfection chamber May have protective oil smell for the first use Clean the cavity
The Chamber is not clean Clean the chamber
The disinfection chamber emits smoke or a burning smell The internal components of the chamber are damaged Contact dealer
Failed to pass UV dose verification UVC lamp tube aged Change the lamp tube correctly according to the manual
Incorrect operation Follow the instructions correctly

Note: UV lamp and ballast shall be handled according to local laws and regulations. For more information, please visit Signif y website https://www.lighting.philips.com/main/products/uv-disinfection/object