SEALEY PEH9001 9000W Industrial PTC Fan Heater Instruction Manual

INDUSTRIAL PTC FAN HEATER 9000W/415V
MODEL NO: PEH9001

PEH9001 9000W Industrial PTC Fan Heater

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

This product is only suitable for well-insulated areas or occasional use.

SAFETY

1.1. ELECTRICAL SAFETY
WARNING! ELECTRICAL INSTALLATION OF THE FAN HEATER TO A 3-PHASE 415VOLT SUPPLY MUST ONLY BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
1.1.1. Make sure the power supply cable is correctly connected to the earth. It is the user’s responsibility to read, understand and comply with the following:
1.1.2. You must check all electrical equipment and appliances to ensure they are safe before use. You must inspect power supply leads, plugs, and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimized by the installation of appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated into the main distribution board.
1.1.3. You must also read and understand the following instructions concerning electrical safety.
The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance and the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.1.4. Ensure insulation on all cables and the product itself is safe before connecting to the main power supply.
1.1.5. Ensure that cables are always protected against short circuits and overload.
1.1.6. Regularly inspect power supply, leads, plugs, and all electrical connections for wear and damage, especially power connections, to ensure that none are loose.
1.1.7. Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used. A three-phase plug must be fitted to this machine.
× DO NOT pull the powered appliance by the power cable.
× DO NOT pull power plugs from sockets by the power cable.
× DO NOT use worn or damaged leads, plugs, or connections. Immediately replace or have repaired by a qualified electrician.
1.1.8. This product must be fitted with a 3-phase plug according to the diagram and will require a minimum supply of, 16Amps per phase.
1.1.9. You must contact a qualified electrician to ensure an appropriately fused supply is available. Connect GREEN/YELLOW wire to earth (E) terminal.
Connect the live wires to live 1, 2, and 3.

1.1.10. When completed, check that there are no bare wires, that all wires have been connected correctly, that the cable external insulation extends beyond the cable restraint and that the restraint is tight.
1.2. General
WARNING! Disconnect the heater from the main power supply before carrying out any servicing or maintenance.
√ Maintain the heater in good order and clean condition for best and safest performance. Replace or repair damaged parts.
√ Locate the heater in a suitable work area and keep the area clean, tidy, and free from unrelated materials. Ensure there is adequate lighting and keep the immediate area in front of the outlet grille clear.
√ Allow the unit to cool before storage. When not in use, disconnect from the mains power supply and store in a safe, cool, dry, childproof area.
√ Only use the heater standing in the upright position on a level surface.
× DO NOT use the heater where there are flammable liquids, solids, or gases such as petrol, solvents, aerosols, etc, or where heat-sensitive materials may be stored.
× DO NOT place the heater near items that may be damaged by heat, allow at least 2mtr clearance in front of the heater.
× DO NOT allow the heater to get wet as this may cause an electric shock, causing damage to the heater and possible personal
injury.
× DO NOT let power lead hang over an edge (i.e. table), touch a hot surface, lie in the beam of heat, or run under a carpet.
× DO NOT use in bathroom, shower room, or in any wet or damp environments or where there is high condensation.
× DO NOT operate the heater when you are tired or under the influence of alcohol, drugs, or intoxicating medication.
× DO NOT insert or allow objects to enter any openings of the heater as this may cause an electric shock, fire, or damage to the heater.
× DO NOT use the heater if the power cord, plug, or the heater is damaged, or if the heater has become wet.
× DO NOT use the heater for any purpose other than for which it is designed.
× DO NOT use a timer or other remote device to operate the heater.
× DO NOT allow children to touch or operate the heater.
× DO NOT site the heater below an electrical socket outlet.
× DO NOT use the heater without the grille fitted.
× DO NOT use the heater out of doors. These heaters are designed for indoor use only.
× DO NOT cover the heater when in use and do not obstruct the air inlet and outlet grilles.
× DO NOT place the heater too close to yourself or any object, allow the air to circulate freely.
× DO NOT touch the outlet grille of the heater during and immediately after use as it will be hot.

INTRODUCTION

Industrial fan heater with PTC heat conducting ceramic elements to achieve an instant, totally dry heat with no condensation, no gas, no fumes, and no smell. The ambient room thermostat maintains the temperature at a pre-set level, Ideal for industrial applications with two heat settings or fans only. Supplied with power cable.

SPECIFICATIONS

Model No:……………………………….PE9001
Power Settings:………………….6000/9000W
Supply:………………………………………..415V
Dimensions (WxDxH):…..400x310x460mm
Weight:……………………………………….6.3kg

HEATER OPERATION

4.1. Place the heater on a level floor in the area you require heat. Allow a minimum of 2mtr between the heater and adjacent objects.
4.2. Plug the heater into the main supply and select the required output by using the rotary switch on the top of the heater. The setting is
4.3. fan only, half heat, full heat. The thermostat is operated by the second nob.
4.4. To switch the unit off, select “0”. Allow the unit to cool before handling or storage.
WARNING! DO NOT touch the top of the heater when in use as it becomes hot.
WARNING! Always allow elements to cool before moving the units. Use only on a smooth even surface.

MAINTENANCE

Warning! Before attempting any maintenance ensure the unit is unplugged from the mains power supply, it is cool and on level ground.
× DO NOT use the heater without the grills fitted.
5.1. Sealey recommends that repairs are carried out by a qualified electrician.

Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories, and packaging should be sorted, taken to a recycling center, and disposed of in a manner that is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

NOTE: It is our policy to continually improve products and as such, we reserve the right to alter data, specifications, and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

01284 757500
01284 703534
www.sealey.co.uk

Get In Touch
Call: 0845 6880112
Email:
Our Address
Prevent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
© Jack Sealey Limited
Original Language Version
PEH9001 Issue 3(ERP) -21/06/18