PACKING LIST

Standard package includes
  • Honeywell Transmission Risk Air Monitor (HTRAM) device X1
  • User Manual X1
  • USB cable X1

ADDITIONAL ACCESSORIES AVAILABLE

  • AC adapter: HTRAM-AD-USC (USC version), or HTRAM-AD-EU (EU version) or HTRAM-AD-UK (UK version)
  • Wall mount kit (separate instructions provided in kit)

OPERATION

  1. HTRAM is a desktop or wall-mounted device. We recommend to keep it plugged-in so it’s powered by the external USB charger. There is a rechargeable battery inside that will supply power for up to 10 hours, but we recommend keeping the device plugged-in to conserve battery life.
  2. Device On/Off: When the device in OFF status, push and hold button for 3 seconds to turn it on. The device will show information on the screen. After the initial process (approximately 1 minute), the device enters normal status and displays readings. When the device is in ON status, push and hold top button for 3 seconds to turn it OFF.

USER INTERFACE

SYMBOL FUNCTION
Bluetooth™ icon
Battery capacity level
USB power input, icon will show on screen

LOW HVAT RISK

HVAT* risk level: low, medium, high

400 CO₂ PPM

CO2 concentration reading

18 C

Temperature reading, °C or °F

54%RH

Humidity reading

– –

For the first use/power on, the device will initially show “- -” for approximately 1 minute

*HVAT Risk indicates the potential risk level of the room, with Honeywell algorithms using CO2 levels and user settings that ac- count for human activity levels in an indoor area.

QUICK START GUIDE

Step 1. Make sure you have everything, then charge the device.

  • Make sure these components were in the box. If any are missing, please contact the company from which you purchased the device as soon as possible:

    Air Monitor

    USB Cable

    User Manual

  • Connect the microUSB end to the device, and the USB connector to a power adapter or computer. Keep plugged-in until fully charged.
  • Make sure the working environment is supported by Bluetooth™ and wireless with Internet access, and a user-supplied smartphone using Apple iOS or Android™.
  • Step 2. Power up the device, download the app and complete the setup:
    • Remove the protective film from the monitor display.
    • Turn on the Transmission Risk Air Monitor by pressing and holding the “Start” button on the top for five seconds. Use a smartphone to download the Honeywell air monitor app (App name: Transmission Risk Air Monitor). You can download directly from the Apple™ or Google™ stores, or by scanning the appropriate QR code shown below if your phone has a scanning app or embedded capability.
    • Launch the app. Then, complete the connection and setup by following the Bluetooth pairing process in this document.
      HOW TO PAIR YOUR DEVICE
      1. Open the App, and enable mobile Bluetooth® in the device’s Settings/Bluetooth.
      2. Double click on the device button. The Bluetooth icon on the device’s screen will appear and blink, waiting for pairing.
        Note:The button must be pushed to enable the device’s Bluetooth. The Bluetooth icon will blink for one minute, and Bluetooth will be shut down if no connection is found. Double click the button again to enable the device’s Bluetooth option.
      3. On the App, click the +Add New icon to add an air monitor device. (see Figures 1-2)
      4. Confirm the device is ready for pairing: See the icon blinking. Ensure the device’s Bluetooth icon is blinking on the screen. (see Figure 2)
      5. If two or more devices’ Bluetooth are activated, you can use the serial number to identify which device is to be paired. The serial number can be found on the back side of the device.
      6. Click the Connect icon to pair with the device.
      7. The app will pop up a window and request the user to input the PIN CODE shown on the device’s screen.
      8. Input the 6-digit PIN CODE.Then, click Connect.
      9. When the Bluetooth icon on the device’s screen stops blinking, pairing is complete.

      Monitors should be placed in the center of activity areas and should be close to breathing height (approximately 1.5 m, depending on the height or age of the room’s occupants), out of direct sunlight, and not directly located near induction units, floor fans, or heaters.
      In an organizational setting, e.g. schools, restaurants, we recommend physically
      protecting the device by placing a lock on the device enclosure and enabling only authenticated access to the secure devices. Ensure that only authorized personnel have the required keys to physically access the devices.

      DEVICE INDICATION AND RECOMMENDED ACTIONS

      SCENARIO SELECTION
      • The device has three pre-programmed scenario settings based on low/medium/high activity levels.
        – Low activity: Reading, quietly talking, 6-foot social distancing, activity duration less than 30 minutes
        – Medium activity: Eating, talking loudly, 6-foot social distancing, activity duration less than 45 minutes
        – High activity: Running, jumping, exercising, limited social distancing, higher exhalation rate, activity duration over 45 minutes
      • The default setting is the low activity setting with the alarm threshold of 800 ppm for medium and 1100 ppm for high.
      • Please refer to the table below for details and to check thealarm threshold settings for each activity-based setting.

      SCENARIO ALARM THRESHOLD

      HVAT Risk Level Low Activity Medium Activity High Activity
      Low (no Alarm) (CO2-ppm <800 <700 <600
      Medium Alarm (CO2-ppm) 800 700 600
      High Alarm (CO2-ppm) 1100 1000 800
      • Click +Add to create user-defined scenario. Refer to to the below customized scenario example (Figure 4). Note: User- generated settings may not detect CO2 as accurately.

      DATA HISTORY
      1. To review the device’s data history, please click the “Data History” tab on the mobile app. (Figure 5)
      2. Figure 5 shows the tabs for switching among CO2, temperature, and humidity to view the device’s history. It can be viewed by day, week, or month.
      3. The device’s maximum data storage is approximately 90 days. It will only keep the most recent 90 days worth of data.
      DEVICE DEFAULT SETTINGS
      • Temperature unit: Select your regional temperature measurement unit on your mobile phone app and it will be displayed on the device screen as °C or °F.
      • Alarm sound: Users may enable or disable the device’s buzzer function. When the device’s alarm sound is enabled, the buzzer will beep at medium or high alarm. When the alarm is sound disabled,the buzzer will not beep when medium or high alarm is triggered.
      • Turn off display: users can turn off display on the mobile app. When display is off, users can wake up the device by pushing the top button. Then the display will auto off in 2 minutes.
      HTRAM SPECIFICATIONS

      SPECIFICATIONS

      CHARACTERISTIC CHARACTERISTIC
      Dimensions (H × W × D) 80 mm × 80 mm × 22 mm [3.1 in × 3.1 in × 0.87 in]
      Weight 140g
      Housing materials Aluminum alloy
      Display TFT
      Input voltage 5 V
      Input current 1 A
      Battery Lithium-ion rechargeable battery 10-hour battery time
      Battery capacity 2,600 mAh
      Operating temperature and humidity 0°C to 40°C, 0% RH to 90% RH
      USB port Micro USB

      * The Honeywell Transmission Risk Air Monitor (HTRAM) analyzes specific air quality conditions and alerts the user when conditions are present that may increase risk of potential exposure to airborne viral transmission. It does not prevent or reduce virus transmission nor mitigate viruses that may be present, nor does it detect or warn against the presence of any virus, including but not limited to COVID-19. The HTRAM does not repel or destroy any microorganism, viruses, bacteria, or germs.

      • It is buyer’s sole responsibility (1) to determine the suitability of the HTRAM for use in its application, (2) to operate the HTRAM in accordance with the User Manual and any other instructions provided by Honeywell, (3) to determine, based on buyer’s experience, expertise, and other available tools, the suitability of any product or service it may offer or recommend to the end user.
      • Buyer is responsible for determining whether the product is appropriate for use under certain statutory guidelines and is likewise responsible for determining whether the HTRAM qualifies for any government reimbursement programs.
      • Any recommendations or assistance provided by Honeywell regarding
        the use or operation of the HTRAM – through our literature, the Honeywell web site, or otherwise – shall not be construed as representations or warranties of any kind, express or implied, and such information is accepted at buyer’s own risk and without any obligation or liability to Honeywell.
      • The information we supply in this data sheet is believed to be accurate
        and reliable as of this writing. However, specifications may change without notice, and Honeywell assumes no responsibility for its use.
      • The HTRAM does not detect for levels of CO2 that would make for an unsafe or unsuitable breathing environment.
      WARRANTY
      • Under normal use and maintenance that is consistent with Honeywell manuals and instructions, Honeywell warrants that, for a period of one (1) year from the date of purchase, all components of this product, except software and software components, shall be free from faulty workmanship and defective materials. The software and software components, including any documentation designated by Honeywell for use with such software or software components, are provided “AS IS.”
      • These warranties do not apply if the claimed defect or nonconformity is due to accident, misuse, neglect; or improper shipping or handling, installation, or testing; or any failure of electrical power, air conditioning, or humidity control. This warranty is valid only if the product has not been tampered with or serviced by any party not authorized by Honeywell.
      • If during the one-year warranty, the customer notifies Honeywell in writing of any alleged defect within 30 days of discovery, and it is determined by Honeywell that any component of the product, except software components, is defective due to faulty workmanship or defective materials, then Honeywell shall repair or replace such Product at Honeywell’s sole discretion. Repair or replacement of a product (or any part thereof) does not extend the warranty period for such product. Products which have been repaired or replaced during the warranty period are warranted for the remainder of the unexpired portion of the original warranty period
      • In case of non-conforming products, users may return such product to the distributor where they made the original purchase.
      • Honeywell shall not be responsible for any loss or damage of any form, including any accidental or necessary direct or indirect loss as a result of breach of any warranty or any other acts that damage the product.
      • These explicit warranties are the only warranties provided by Honeywell with respect to the product and are in lieu of all  otherwarranties, express or implied. Any implied warranty or guarantee, including merchantability, fitness for a particular purpose, and non-infringement of third party rights, shall not apply.
      • This warranty only applies to the main unit of the product, and does not cover the package, manuals, consumables, or other components susceptible to damage or consumption or which have a normal life inherently shorter than the foregoing warranty period.
      • Customers wanting additional warranty beyond the standard one-year warranty offered by Honeywell have the option to purchase a 2-year extended warranty when purchasing the product. Any such extended warranty shall only extend the timeframe of the warranty terms above from three years from the date of purchase, and shall not provide any additional warranty or guarantee, express or implied.
      DISPOSAL

      This product contains a lithium-ion battery and aluminum alloy materials. Upon receipt of the product, the customer is responsible for proper use, transport, storage and disposal of the product based on the battery and material type, including but not limited to applicable governmental requirements for proper disposal

      CAUTION

      Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

      SIMPLIFIED EU DECLARATION OF CONFORMITY
      Hereby, Honeywell Analytics Inc. declare that the radio equipment type HTRAM-V1-W is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available on request.

      ECHARGEABLE LI-ION BATTERY

      Nominal Voltage: 3.6V
      Rated Capacity: 2480 mAh/8.93Wh
      Typical Capacity: 2600 mAh/9.36Wh
      Limited Charging Voltage: 4.2V
      Manufacturer: SCUD (Fujan) Electronics Co., Ltd.
      Red Wire: (+) Black wire: (-)
      Made in China

      WARNING: TO PREVENT INJURY, DO NOT DISASSEMBLE, PUNCTURE, CRUSH, HEAT, OR BURN.
      Use the authorized charger only. Never disassemble by yourself. Never short-circuit the battery. Dispose of the battery properly. Exposing the battery to an open flame could cause an explosion.
      Strangulation HAZARD:
      Children have STRANGLED in cords. Keep this cord out of reach of children (more than 3 ft (1m) away). Do not use with an extension cord.
      ATTENTION
      • To better reflect the air environment, Honeywell recommends continuously monitoring indoor air using the HTRAM. It is recommended that the device runs for 24 hours for the first time until it is fully charged and initialized.
      • For safety and battery performance, the device can only charge the battery indoors in a 0°C to 40°C [32°F to 104°F] temperature range. The charging time from empty to full battery is approximately 6 hours. During charging, the device surface will have a slight temperature rise.
      INSTRUCTIONS IN OTHER LANGUAGES
      • Please scan the QR code below to download the User Manual in the following languages.

      French

      German

      Italian

      Spanish

      Portuguese