SEALEY HVF16 Industrial High Velocity Fans Instructions
INSTRUCTIONS FOR:
INDUSTRIAL HIGH-VELOCITY FANS
MODELS: HVF16 & HVF18.V3
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble-free performance.
SAFETY INSTRUCTIONS
1.1. ELECTRICAL SAFETY
” WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimized by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply that is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible Yellow & Green for the safe condition of those appliances and the safety of the appliance operators. If in Earth Wire any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuits and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 3-pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal `E’.
b) Connect the BROWN live wire to the live terminal `L’.
c) Connect the BLUE neutral wire to the neutral terminal `N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends beyond the cable restraint, and that the restraint is tight. Double insulated products, which are always marked with this symbol, are fitted with live (brown) and neutral (blue) wires only. To rewire, connect the wires as indicated above – DO NOT connect either wire to the earth terminal.
1.1.10. Products that require more than 13 amps are supplied without a plug. In this case, you must contact a qualified electrician to ensure that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm2, but to be absolutely sure that the capacity of the reel is suitable for this product and for others that may be used in the other output sockets, we recommend the use of a 2.5mm2 section cable. If the extension reel is to be used outdoors, ensure it is marked for outdoor use.
1.2. GENERAL SAFETY !
WARNING! If a fan falls into water or other liquid, immediately switch off and disconnect from the mains power supply.
X DO NOT operate the fan where there are explosive or flammable gases, fumes or other hazardous substances.
X DO NOT stand the fan on the power cable.
X DO NOT insert any objects through the fan guard.
X DO NOT cover the fan when in use.
X DO NOT immerse the fan in water or any other liquid.
X DO NOT allow children to operate the fan.
X DO NOT stand the fan where it may be knocked over or off a surface, or where the lead may cause a person to trip.
X DO NOT use the fan outdoors.
X DO NOT modify speed control or attempt to fit any additional external speed control device to the fan.
INTRODUCTION & SPECIFICATION
High-velocity fans are suitable for the movement of huge volumes of air. Carefully balanced and fully guarded blades provide quiet and safe operation. Three-speed power selection and cradle stand allow precise control of airflow to exactly where it is needed. Fitted with BS-approved plug. Suitable for use in industrial, commercial, agricultural, and automotive workshop and showroom applications.
Fan Diameter: . . . . . . .400mm(16″) . . . . . . . . . . . 450mm(18″)
Speeds: . . . . . . . . . . . . . . . . . . . .3 . . . . . . . . . . . . . . . . . . . . 3 Motor
Power: . . . . . . . . . . . . .80W . . . . . . . . . . . . . . . . . 90W
Supply: . . . . . . . . . . . . . . . . .230V . . . . . . . . . . . . . . . . . 230V
Current: . . . . . . . . . . . . . . . . .0.3A . . . . . . . . . . . . . . . . . 0.5A
OPERATION
WARNING! Ensure that you read, understand, and apply safety instructions in Section 1 before using a fan.
3.1. Check that the speed control is set to “0” (off) and then plug into the mains power supply and switch the power on.
3.2. The fan features 3 speeds that are selectable using the control buttons located at the back of the fan above the motor. See Fig.4. LOW (1) or MED (2) settings will suit most needs, HIGH (3) is used for maximum air movement.
3.3. Adjust the direction of the airflow by moving the base from side to side and tilting the fan up or down.
3.4. When you have finished using the fan ensure you turn the speed control switch to “0” (off) and disconnect the fan from the mains power.
CARE OF FAN
WARNING! Ensure that the fan is disconnected from the mains power supply before attempting any of the following:
4.1 Use a soft, damp cloth to clean the fan. DO NOT immerse the fan in water and never allow water to drip onto the motor housing. DO NOT use solvents, petroleum, paint thinner, or other chemicals to clean the fan.
4.2 To clean the fan blade, undo screw B and remove ring A which holds the front and rear grilles together. Remove the front grille and clean the blade and inside the grilles. Replace the front grille and refit the ring securing with screw B.
4.3 Should the motor, speed control box or the power lead require service or maintenance contact your local service agent.
4.4 When not in use place the fan in its original box or otherwise cover to protect it from dust, and store in a safe, dry, childproof location.
DECLARATION OF CONFORMITY
Declaration of Conformity We, the sole importer into the UK, declare that the products listed below are in conformity with the following standards and directives.
IND. HIGH-VELOCITY PEDESTAL FAN Models HVF16 & HVF18.V3
89/336/EEC EMC Directive
/23/EEC Low Voltage Directive
93/68/EEC CE Marking Directive
Signed by Mark Sweetman
20th November 2006
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
NOTE: It is our policy to continually improve products and as such, we reserve the right to alter data, specifications, and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalog and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
Sealey Group,
Bury St. Edmunds, Suffolk.
HVF16 & HVF18.V3 – 1 – 20/11/06
Our Address
Prevent, Adremit Limited, Unit 5a, Commercial Yard
Settle, North Yorkshire, BD24 9RH